• 제목/요약/키워드: Diaphragm system

검색결과 214건 처리시간 0.025초

Settlement Reduction Effect of Advanced Back-to-Back Reinforced Retaining Wall

  • Koh, Taehoon;Hwang, Seonkeun;Jung, Hunchul;Jung, Hyuksang
    • International Journal of Railway
    • /
    • 제6권3호
    • /
    • pp.107-111
    • /
    • 2013
  • In order to constrain the railway roadbed settlement which causes track irregularity, and thus threats running stability and ride quality, advanced Back-to-Back (BTB) reinforced retaining wall was numerically analyzed as railway roadbed structure. This study is intended to improve conventional Back-to-Back reinforced retaining wall as the technology which would reduce the roadbed settlement in a way of constraining the lateral displacement of its prestressed vertical facing and inducing arching effects in roadbed (backfill) placed between masonry diaphragm wall and vertical facing. As a result of numerical analysis, it was found that the roadbed settlement was reduced by 10% due to the prestressed vertical facing and embedded masonry diaphragm wall of the advanced Back-to-Back reinforced retaining wall system.

폐내엽형 격절부 1례 보고 (Intralobar Pulmonary Sequestration: Report Of One Case)

  • 조중구
    • Journal of Chest Surgery
    • /
    • 제14권4호
    • /
    • pp.354-358
    • /
    • 1981
  • Intralobar pulmonary sequestration is a rare congenital malformation characterized by a cystic portion of the lung that derives its arterial blood supply through aberrant vessel directly of systemic circulation. Intralobar pulmonary sequestration Is usually contained within the visceral pleura of a pulmonary lobe and its venous drainage to the pulmonary venous system. We experienced a case of pulmonary sequestration preoperatively confirmed. The patient was 17 year old female whose complaints were mild fever and profuse purulent sputum. Chest film showed a large thin walled cystic lesion with air-fluid level at the left lower posterior basal lung field. Aortogram revealed an aberrant artery originated from thoracic aorta just above the diaphragm and that drained via pulmonary vein into the left atrium. At time of operation, a large abscess cavity measuring 9x8x3 cm in dimension at the left lower lobe was noted. And the aberrant artery, measuring 0.5 cm in diameter and 2 cm in length, arising from thoracic aorta just above the diaphragm was noted. After division and ligation of the aberrant artery, a left lower lobectomy was performed and the patient`s postoperative course was uneventful.

  • PDF

강교 부재의 설계정보 표현을 위한 IFC 모델의 확장 방안 (An Extension Method of IFC Model for Representing Design Information of Steel Bridge Members)

  • 이진훈;황명강;이지훈;이상호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.524-531
    • /
    • 2008
  • A method for representing detailed design information of steel bridge member is proposed on the basis of the IFC model. As a first step, bridge related entities in the IFC-BRIDGE V2 and their functions are analyzed. In addition, design documents of steel bridge members are analyzed to extract information items that are not handled in the IFC-BRIDGE V2. It is recommended that several entities in the IFC-BRIDGE V2, such as ifcBridgeFibre, IfcBridgeReferenceLine, and IfcBridgeSection, should be properly relocated. In addition, IfcBridgeStiffener, IfcBridgeJointSystem, IfcBridgeDiaphragm, and IfcBridgeShearConnector are added as subtypes of IfcBridgeElementComponent for representing the stiffener, joint system, diaphragm, and shear connector, respectively. The added new entities inherit all attributes of IfcProduct which is linked with other resources: geometric representation, placement, material information, and so on. Thus, it is considered that a proposed in-depth IFC-BRIDGE model can be used more widely.

  • PDF

Development of a Peristaltic Micropump with Lightweight Piezo-Composite Actuator Membrane Valves

  • Pham, My;Goo, Nam-Seo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권1호
    • /
    • pp.69-77
    • /
    • 2011
  • A peristaltic micropump with lightweight piezo-composite actuator (LIPCA) membrane valves is presented. The micropump contained three cylinder chambers that were connected by microchannels and two active membrane valves. A circular miniature LIPCA was developed and manufactured to be used as actuating diaphragms. The LIPCA diaphragm acted as an active membrane valve that alternate between open and closed positions at the inlet and outlet in order to produce high pumping pressure. In this LIPCA, a lead zirconium titanate ceramic with a thickness of 0.1 mm was used as an active layer. The results confirmed that the actuator produced a large out-of-plane deflection. During the design process, a coupled field analysis was conducted in order to predict the actuating behavior of the LIPCA diaphragm; the behavior of the actuator was investigated from both a theoretical and experimental perspective. The active membrane valve concept was introduced as a means for increasing pumping pressure, and microelectromechanical system techniques were used to fabricate the peristaltic micropump. The pumping performance was analyzed experimentally in terms of the flow rate, pumping pressure and power consumption.

공압식 심실보조장치의 개발 및 평가 (Development and Evaluation of Pneumatic Ventricular Assist Device)

  • 이상훈;박이태;김삼현;한동선;이학중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.247-250
    • /
    • 1995
  • The purpose of this paper is to develop diaphragm-type pneumatic ventricular assist device(VAD) for clinical application and to evaluate its performance through the mock circulation system. The blood housing and diaphragm are made by coating pellethane on the metallic mold and the back plate is made by machining process. The relations of cardiac output(CO) vs. beat rate and CO vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. As a result, the volume of blood pump is 70 ml, maximum CO is 5 L/min and CO has a close relation to the input resistance of blood pump. The hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

모듈러 건축물의 수평력 저항 구조시스템 (Lateral-resisting Structural Systems for Tall Modular Buildings)

  • 이창환;정광량
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.79-88
    • /
    • 2016
  • Modular buildings are constructed by assembling modular units which are prefabricated in a factory and delivered to the site. However, due to a problem of noise between floors, concrete slab is usually poured at the top or bottom level of a modular unit in Korea. This greatly increases the weight of buildings, but designing vertical members of modular units to resist overall gravity loads is very inefficient. In this study, considering domestic building construction practices, feasible structural systems for tall modular buildings are proposed in which separate steel frames and reinforced concrete core walls are designed to resist gravity and lateral loads. To verify performance, a three-dimensional structural analysis has been performed with two types of prototype buildings, i.e., a residential building and a hotel. From the results, wind-induced lateral displacements and seismic story drifts are examined and compared with their limit values. Between the two kinds of buildings, the efficiency of the proposed system is also evaluated through a comparison of the weight of structural components. Finally, the effect of a floor diaphragm on the overall behavior is analyzed and discussed.

IGRT를 위한 비침습적인 호흡에 의한 장기 움직임 실시간 추적시스템 (A Non-invasive Real-time Respiratory Organ Motion Tracking System for Image Guided Radio-Therapy)

  • 김윤종;윤의중
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권5호
    • /
    • pp.676-683
    • /
    • 2007
  • A non-invasive respiratory gated radiotherapy system like those based on external anatomic motion gives better comfortableness to patients than invasive system on treatment. However, higher correlation between the external and internal anatomic motion is required to increase the effectiveness of non-invasive respiratory gated radiotherapy. Both of invasive and non-invasive methods need to track the internal anatomy with the higher precision and rapid response. Especially, the non-invasive method has more difficulty to track the target position successively because of using only image processing. So we developed the system to track the motion for a non-invasive respiratory gated system to accurately find the dynamic position of internal structures such as the diaphragm and tumor. The respiratory organ motion tracking apparatus consists of an image capture board, a fluoroscopy system and a processing computer. After the image board grabs the motion of internal anatomy through the fluoroscopy system, the computer acquires the organ motion tracking data by image processing without any additional physical markers. The patients breathe freely without any forced breath control and coaching, when this experiment was performed. The developed pattern-recognition software could extract the target motion signal in real-time from the acquired fluoroscopic images. The range of mean deviations between the real and acquired target positions was measured for some sample structures in an anatomical model phantom. The mean and max deviation between the real and acquired positions were less than 1mm and 2mm respectively with the standardized movement using a moving stage and an anatomical model phantom. Under the real human body, the mean and maximum distance of the peak to trough was measured 23.5mm and 55.1mm respectively for 13 patients' diaphragm motion. The acquired respiration profile showed that human expiration period was longer than the inspiration period. The above results could be applied to respiratory-gated radiotherapy.

진공배력장치 출력특성에 대한 연구 (A Study on the Output Characteristic of Vacuum Booster)

  • 이춘태
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.110-116
    • /
    • 2009
  • In the present study, we proposed a simulation model of vacuum booster with AMESIM software to predict the output characteristic. And we performed the sensitivity analysis of output characteristic with main design parameters, such as diaphragm diameter. All of these parameters are main design parameters in the procedure of vacuum booster design. The simulation results of this paper offer qualitative information of vacuum booster output. Therefore, the simulation results of this paper will be used effectively for the design procedure of vacuum booster in the industrial field.

  • PDF