• Title/Summary/Keyword: Diaphragm frequency

Search Result 89, Processing Time 0.026 seconds

A Study on the Reduction of the Sloshing of Storage Tank Using Wing and Diaphragm Baffle (날개형 및 격막형 배플을 이용한 유체저장탱크 내부의 슬로싱 저감 연구)

  • Lee, Young-Shin;Kim, Hyun-Soo;Lee, Jae-Hyung;Kim, Young-Wann;Ko, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.12
    • /
    • pp.2039-2046
    • /
    • 2003
  • Storage tank filled with fluid has unique dynamic characteristics compared to general structures, due to the interaction between fluid and structure. The oscillation of the fluid surface caused by external forces is called sloshing, which occurs in moving vehicles with contained liquid masses, such as trucks, railroad cars, aircrafts, and liquid missles. In this study, the evaluation method for the reduction of sloshing, the optimized size and location of wing and diaphragm baffles are suggested based on the experimental results. The experimental device can simulate the translation motion. A rectangular tank and various baffles are fabricated to study on the sloshing characteristics. The forces measured using the load cell at tank wall and those are compared with each other through the Fourier transformation for various conditions. The study of the sloshing of the rectangular tank equipped with baffles is conducted under the same conditions with non-baffled rectangular tank experiment. From the experimental results, the sloshing reduction effect by the baffles is observed. In conclusion in case of diaphragm baffles, the optimized size ratio of the width of baffle to the water height is 0.44 and the installation location has no effect to the damping of sloshing. In case of wing baffles, the optimized size ratio of the width of baffle to the length of a rectangular tank is 0.1 and the optimized location ratio of the baffle to the water height is 0.9.

A Clinical Analysis of 20 cases of Diaphragmic Rupture (외상에 의한 횡격막 파열의 임상적 고찰)

  • 이계선;정진악;금동윤;안정태;이재원;신제균
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.394-398
    • /
    • 1999
  • Background: According to the changes in the Environmental factors, traumatic diaphragmic rupture is seen in increasing frequency. Many reports described the early diagnostic methods and treatment modalities. In our institution, a study was retrospectively performed to obtain the early diagnostic and treatment methods of diaphragmic ruptures. Material and Method: From January 1994 to April 1998, 20 patients with traumatic rupture of the diaphragm were treated in our institution and We analyzed the patients in preoperative clinical presentations, diagnostic accuracies, associated injuries and postoperative complications. Result: Socially active male patients were affected most. 75% of patients had blunt trauma and 25% had penetrating injury. There were 16 cases of ruptured right diaphragm, 3 cases of left diaphragm and 1 case on both. Preoperative diagnosis were possible in 10 patients (50%) and 6 patients(30%) were diagnosed intraoperatively, but 4 patients (20%) were diagnosed in the late stages. Most common postoperative complication was wound infection, and two died of associated injuries. Conclusion: We conclude that if there is suspicion of diaphragmic rupture after a trauma, careful study and examination is essential and interdepartmental collaboration is very important.

  • PDF

Controller design for compensation of nonlinear harmonic distortion in direct-radiator loudspeakers (직접 방사형 스피커의 비선형 고조파 왜곡 보상 제어기의 설계)

  • 김윤선;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.399-402
    • /
    • 1996
  • The electrodynamic loudspeakers should have a wide dynamic range to reproduce various sound levels. When the input signal is small, the radiated sound from the loudspeaker is not so much distorted. However, for large input signal with low frequency component the radiated sound is significantly distorted due to the nonlinearities of the loudspeaker. The suspension, damping, and magnetic flux of loudspeaker are the main sources of the nonlinearity. Such electromechanical parameters related to harmonic distortion have been represented by a polynomial model for diaphragm displacement, while each of the polynomial coefficient is evaluated by using the principle of harmonic balance experimentally. Based on the polynomial model, we designed a compensator for nonlinear harmonic distortion of direct radiator loudspeaker. Than observer is used to estimate the displacement of the loudspeaker diaphragm, which is rather difficult to measure directly in the conventional setting. The usefulness of the designed compensator is demonstrated by numerical simulations. Simulation results show about 30db decrease at the second and third higher harmonic distortions. We carry out an experiment on speaker to verify designed controller and nonlinear observer.

  • PDF

Optical Microphone Incorporating a Reflective Micromirror and a Dual-core Collimator (반사형 마이크로미러와 듀얼 코어 클리메이터를 이용한 광 마이크로폰)

  • Song, Ju-Han;Kim, Do-Hwan;Gu, Hyun-Mo;Park, Hyun-Jung;Lee, Sang-Shin;Cho, Il-Joo
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.94-98
    • /
    • 2006
  • An optical microphone based on a dual-core fiber collimator and a membrane type micromirror serving as an optical head and a reflective diaphragm respectively was implemented. The micromirror diaphragm is suspended by a thin silicon bar linked with a frame, thus it is subject to a displacement induced by acoustic waves. The optical head incorporating two collimators integrated in a single housing gives light to and receives it from the diaphragm, rendering the optical microphone structure simple and compact. This dual-core collimator having a slowing varying beam profile facilitates the initial alignment of the optical head with the diaphragm, especially the distance between them. For the assembled microphone, the static characteristics were investigated tofind the operation point defined as the optimum distance between the head and the diaphragm, and a frequency response with a variation of about $\pm$5 dB for the range of up to 3kHz was achieved.

Structural Analysis Models to Develop Live Load Distribution Factors of Simply Supported Prestressed Concrete I-Girder Bridge (활하중 분배계수식 개발을 위한 I형 프리스트레스트 콘크리트 거더 교량의 구조해석 모델)

  • Lee, Hwan-Woo;Kim, Kwang-Yang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.1
    • /
    • pp.91-101
    • /
    • 2008
  • Structural analysis models to develop live load distribution factors of simply supported prestressed concrete I-girder bridge should have the precision of the analysis results as well as modeling simplicity. This is due to the numerous frequency of structural analysis needed while developing live load distribution factors. In this study, an appropriate structural analysis model is selected by comparing previous researchs studies and models used in practical design. Also, the influence by the flexural stiffness of barrier and diaphragm on the live load distribution had been analyzed through comparing the numerical analysis and experimental tests. As a result, the model that the eccentric girder and the barrier and diaphragm are connected to the deck plate was appropriate in satisfying both accuracy and simplicity for structural analysis of simply supported prestressed concrete I-girder bridge. However, the barrier was analyzed to have insignificant influence on the live load distribution in spite of its variation of stiffness. The eccentric diaphragm showed little influence at 25% or higher of flexural stiffness. From the results, a model that the girder is rigidly connected to the deck plate in consideration of the eccentricity, the barrier is ignored and the whole section of diaphragm is supposed to be valid without eccentricity is decided as the most appropriate structural model to develop the live load distribution factors of simply supported prestressed concrete I-girder bridge in this study.

미세 압전 캔틸러버를 이용한 마이크로 폰 및 마이크로 스피커

  • 이승섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.347-351
    • /
    • 1997
  • A micromachined piezoelectic cantilever transducer,which works both as a microphone and as a microspeaker,has been fabricated and tested. The 2000*2000*3.mu.m .sap2. cantilever has oxide(ZnO)piezoelectric thin film on a supporting layer of low-pressure chemical-vapor-deposited(LPCVD)low-stress siliconnitride. A highlight of the fabrication process which may also be relevant for other micromachined stuctures is the technique for producing a flat,multilayer cantilever. The measured microphone sensitivity is fairly constant at 2 mV/.mu.bar in the low frequency range and rise to 20 mV/.mu.bar at the lowest resonant frequency of 890 Hz. The 2 mV/.mu.bar sensitivity is the highest report to data for a microphone with a micromachined diaphragm. When measured into a 2 cm/sap3 coupler with 4V (zero-park)drive,the microspeaker output sound pressure level(SPL) is 75 dB at 890 Hz. It increases to approximately 100dB SPL at 4.8kHz with 6V(zero-park)drive. The measured microphone frequency response agrees well with the results of an ABAQUS simulation.

Design of Housing Structure for the Suppression of Higher­Order Modes in the Microstrip Circuit Packaging (마이크로스트립 회로 패키징의 고차모드 차폐를 위한 하우징 설계)

  • 전중창
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1621-1628
    • /
    • 2003
  • Packaging structures to block the propagation of higher­order modes in the shielded microstrip lines are designed. Packaging for microwave circuits is necessary, basically, to isolate and protect circuits from outside environments both physically and electrically. The drawback of packaging is the possibility of higher­order mode propagation, similar to waveguide modes, as the operating frequency increases. One of Possible choices for the higher­order mode suppression is to insert diaphragms to the housing structure. The shielding effects of diaphragms are analyzed using an FEM code. Several parameters such as dispersion, mode conversion, and higher­order mode transmission and reflection are analyzed. The effect of higher­order mode suppression is eminent as the depth or width of a diaphragm is increased in the air region of the microstrip line. It is shown that inductive diaphragm structure can lower ${S_21}$ for the second­order mode incidence by 30㏈, comparing with the conventional capacitive diaphragm structure. Packaging structure analyzed in this paper can be applied usefully to the design of the microwave system in a package such as transmit/receive modules.

Electromagnetic Microactuators with the Electroplated Planar Coil Driven by Radial Magnetic Field (방사형 자기장 내의 전기도금된 평면코일을 이용한 전자기형 마이크로 액추에이터)

  • Ryu, Ji-Cheol;Gang, Tae-Gu;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.1
    • /
    • pp.16-24
    • /
    • 2001
  • This paper presents an electromagnetic microactuator using the copper coil electroplated on the p+silicon diaphragm. The microactuator generates a vertical motion of the diaphragm using the radial direction, we propose a new actuator structure with twin magnets. The microactuator field in the radial direction, we propose a new actuator structure with twin magnets. The microactator shows a values of resonant frequency and quality factor in the ranges of 10.51${\pm}$0.22kHz and 46.6${\pm}$3.3, respectively. The twin magnet microactuator generates the maximum peak-to-peak amplitude of 4.4$\mu\textrm{m}$ for the AC rms current of 26.8mA, showing 2.4 times larger amplitude than the single magnet microactuator.

Development of Micropump using Circular Lightweitht Piezo-composite Actuator (원형 경량 압전 복합재료 작동기를 이용한 마이크로 펌프의 개발)

  • 구옌탄텅;구남서
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.35-41
    • /
    • 2006
  • In this paper, we focus on improving the performance of the piezoelectric diaphragms of valveless micropumps. A circular lightweight piezoelectric composite actuator (LIPCA) with a high level of displacement and output force has been developed for piezoelectrically actuated micropumps. We used numerical and experimental methods to analyze the characteristics of the actuator to select optimal design. With the developed circular LIPCA, we fabricated a valveless micropump by photo-lithography and PDMS molding techniques. The displacement of the diaphragm, the flow rate and the back pressure of the micropump were evaluated and discussed. With a semi-empirical method, the flow rate with respect to driving frequency was predicted and compared with experimental one. The test results confirm that the circular LIPCA is a promising candidate for micropump application and can be used as a substitute for a conventional piezoelectric actuator diaphragm.

Enhanced Approach Using Computational and Experimental Method for the Analysis of Loudspeaker System

  • Park Seok-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3E
    • /
    • pp.90-98
    • /
    • 2005
  • Enhanced approach using computational and experimental method is proposed and performed to describe very well the behavior of loudspeaker than conventional method. Proposed procedure is composed of four parts. First, Thiele-Small parameters for test loudspeaker are identified by an electrical impedance method like as a delta mass method. Second part includes the processes to measure physical properties. Physical data like masses and thicknesses of loudspeaker's components are measured by an electrical precision scale and a digital vernier caliper. Third, the identified Thiele-Small parameters are proposed to be used as load boundary conditions for vibration analysis instead of electromagnetic circuit analysis to get a driving force upon bobbin part. Also, these parameters and physical data are used to modify physical properties required for computation to accommodate simulated sound pressure level with measured one for loudspeaker enclosure system. These data like as Young's modulus and thickness for a diaphragm are required for vibration analysis of loudspeaker but not measured accurately. Finally, it was investigated that simulated sound pressure level with full acoustic modeling including an acoustic port for test loudspeaker agreed with experimental result very well in the midrange frequency band(from 100 Hz to 2,000 Hz). In addition, several design parametric study is performed to grasp acoustical behaviors of loudspeaker system due to variations of diaphragm thicknesses and shapes of dust cap.