Fabrication and Testing of a Polysilicon Piezoresistive Accelerometer using p+ Silicon Diaphragm (p+ 실리콘 박막을 이용한 폴리실리콘 압저항 가속도계의 제작 및 측정)

  • Yang, E.H.;Jeong, O.C.;Yang, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1994-1996
    • /
    • 1996
  • This paper presents the fabrication and testing of a polysilicon piezoresistive accelerometer with p+ silicon diaphragm by simple process such as two step photolithography for the RIE process to form the cantilevers and a deep anisotropic etch process for the complete fabrication of the accelerometer. The fabricated accelerometer consists of a seismic mass and four cantilevers on which polysilicon piezoresistors are formed. The measurement of the output signal from the bridge circuit of the fabricated accelerometer is carried out with the HP 3582A spectrum analyzer. The analysis of the experimental result is showed in terms of the sensitivity and the resonant frequency. At atmospheric condition, the measurement values of the sensitivity and the resonant frequency are $11\;{\mu}V/Vg$ and 475 Hz, respectively.

  • PDF

Fabrication of an Electromagnetic Actuator with the Planar Coil (평면 코일을 이용한 전자 구동기 제작)

  • Jeong, Hyun-Ku;Kwon, Ki-Young;Jeong, Ok-Chan;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3295-3297
    • /
    • 1999
  • This paper presents the fabrication of an electromagnetic micro actuator consisting of a Parylene diaphragm with a spiral copper coil and a permanent magnet. The copper coil is fabricated by electroplating and patterning. The frequency response of the actuator are obtained using a laser vibrometer. When the input voltage is 3 V, the DC deflection is 5 ${\mu}m$, and the resonance frequency is about 35 Hz. Also, the mechanical sensitivity of the actuator diaphragm is 69 ${\mu}m/V$.

  • PDF

Design and Analysis of IPMC Actuator-driven ZNMF Pump for Air Flow Control of MAV's Wing (IPMC 작동기로 구동되는 초소형 비행체 날개의 공기흐름 조절용 ZNMF(zero-net-mass-flux) 펌프의 예비설계 및 해석)

  • Lee, Sang-Gi;Kim, Gwang-Jin;Park, Hun-Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.3
    • /
    • pp.22-30
    • /
    • 2006
  • In this paper, a systematic design method on an IPMC(ionic polymer-metal composite)-driven ZNMF(zero-net-mass-flux) pump is introduced for the flow control of an MAV's (micro air vehicle) wing. Since the IPMC is able to generate a large deformation under a low input voltage along with its ability to operate in air, and is easier to be manufactured in a small size, it is considered to be an ideal material of the actuating diaphragm. Through the numerical methods, an optimal shape of the IPMC diaphragm was found for maximizing the stroke volume. Based on the optimal IPMC diaphragm, a proto-type ZNMF pump with a slot, was designed. By using the flight speed of the MAV considered in this work, the driving frequencies(~ 40 Hz) of IPMC diaphragm, and the flow velocity through the pump's slot, the calculated non-dimensional frequency and the momentum coefficient ensure the feasibility of the designed ZNMF pump as a flow control device.

Relationship Analysis of Break-up Mode and Heat Transfer of Micro-Speaker Diaphragm (마이크로 스피커 진동판에 대한 분할진동 모드와 열전달의 관계 분석)

  • Kim, Hyun-Kab;Kim, Hie-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.333-336
    • /
    • 2017
  • A speaker diaphragm generates a divided vibration. The influence of the break-up mode is sufficient to cause a shape change in the diaphragm. In this paper, is widely used in ultra-thin multi-media devices, including smart phones is the advance guard of the IT sector, the micro-speakers and its target. Micro-speakers are different from general speakers. The plate has structural form and space constraints. In particular, they utilize a closed-type drive space. It is difficult to provide cooling for the auxiliary suspension structure because of the heat generated in the moving coil. The present study considered the relationship between the break-up mode and the heat transfer of the diaphragm. An experiment was conducted in two stages to compare the embodiment of the break-up mode and heat transfer in a certain frequency range. The changes in the heat were determined through measurements and thermal imaging of the break-up mode. The break-up mode tendency of the diaphragm could be rapidly predicted based on the imaging results using the thermal imaging camera. This will help in the optimal design of micro-speakers.

Fabrication of Integrated Silicon Pressure Sensor (집적화된 실리콘 압력센서의 제작)

  • 이보나;이영준;정승민;이문기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.6
    • /
    • pp.22-30
    • /
    • 1993
  • An integrated silicon pressure sensor with frequency output has been fabricated, measured, and tested. The standard bipolar process is applied and thin diaphragm was formed using EDP anisotropic etchant. Output frequency was 769 Hz-3.1 kHz at the pressure range of 0-10 psi. It operates at the temperature range of 0-50$^{\circ}C$. The frequency sensitivity was 233 Hz/psi and temperature sensitivity was 0.3 Hz/$^{\circ}C$. The power dissipation was 50mW.

  • PDF

A Study on the Reduction of Organ Motion from Respiration (호흡 운동에 의한 내부 장기의 움직임 감소에 관한 연구)

  • Kim Jae-Gyoun;Lee Dong-Han;Lee Dong-Hoon;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Oh Won-Yong;Ji Young-Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.179-185
    • /
    • 2004
  • To deal with tumor motion from respiration is one of the important issues for the advanced treatment techniques, such as the intensity modulated radiation therapy (IMRT), the image guided radiation therapy (IGRT), the three dimensional conformal therapy (3D-CRT) and the Cyber Knife. Studies including the active breath control (ABC) and the gated radiation therapy have been reported. Authors have developed the device for reducing the respiration effects and the diaphragm motions with this device were observed to determined the effectiveness of the device. The device consists of four belts to immobilize diaphragm motion and the vacuum cushion. Diaphragm motions without and with device were monitored fluoroscopically. Diaphragm motion ranges were found to be 1.14 ~ 3.14 cm (average 2.14 cm) without the device and 0.72~1.95 cm (average 1.16 cm) with the device. The motion ranges were decreased 20 ~ 68.4% (average 44.9%.) However, the respiration cycle was increased from 4.4 seconds to 3.7 seconds. The CTV-PTV margin could be decreased significantly with the device developed in this study, which may be applied to the treatments of the tumor sited diaphragm region.

  • PDF

A New Method for Measuring the Distortions of the Loudspeaker at Low Frequencies (스피커의 저주파 대역 왜곡 측정의 새로운 기법)

  • 두세진
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.68-72
    • /
    • 1993
  • A method to measure the distortions of the loudspeaker at low frequencies without an anechoic chamber is proposed. This method utilizes the fact that the n-th harmonic distortion outside the enclosure is boosted by 40log n dB compared to that inside the enclosure. By compensating for the effect of standing waves occuring inside the enclosure, it is possible to predict the distortions for wide frequency ranges below the first break-up frequency of the diaphragm. The method is applicable to the intermodulation distortion as well.

  • PDF

Miniature Ultrasonic and Tactile Sensors for Dexterous Robot

  • Okuyama, Masanori;Yamashita, Kaoru;Noda, Minoru;Sohgawa, Masayuki;Kanashima, Takeshi;Noma, Haruo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.5
    • /
    • pp.215-220
    • /
    • 2012
  • Miniature ultrasonic and tactile sensors on Si substrate have been proposed, fabricated and characterized to detect objects for a dexterous robot. The ultrasonic sensor consists of piezoelectric PZT thin film on a Pt/Ti/$SiO_2$ and/or Si diaphragm fabricated using a micromachining technique; the ultrasonic sensor detects the piezoelectric voltage as an ultrasonic wave. The sensitivity has been enhanced by improving the device structure, and the resonant frequency in the array sensor has been equalized. Position detection has been carried out by using a sensor array with high sensitivity and uniform resonant frequency. The tactile sensor consists of four or three warped cantilevers which have NiCr or $Si:B^+$ piezoresistive layer for stress detection. Normal and shear stresses can be estimated by calculation using resistance changes of the piezoresitive layers on the cantilevers. Gripping state has been identified by using the tactile sensor which is installed on finger of a robot hand, and friction of objects has been measured by slipping the sensor.

An Efficient Transmissibility-design Technique for Pneumatic Vibration Isolator (지반진동절연을 위한 공압제진대의 전달률 설계기법)

  • Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.411-423
    • /
    • 2008
  • Pneumatic vibration isolator has a wide application for ground-vibration isolation of vibration-sensitive equipments. Recent advances In precision machine tools and instruments such as nano-technology or medical devices require a better isolation performance, which can be efficiently done by precise modeling- and design- of the isolation system. This paper will discuss an efficient transmissibility design method for pneumatic vibration isolator by employing the complex stiffness model of dual-chamber pneumatic spring developed in our previous research. Three design parameters of volume ratio between the two pneumatic chambers, the geometry of capillary tube connecting the two pneumatic chambers and finally the stiffness of diaphragm necessarily employed for prevention of air leakage were found to be important factors in transmissibility design. Based on design technique that maximizes damping of dual-chamber pneumatic spring, trade-off among the resonance frequency of transmissibility, peak transmissibility and transmissibility in high frequency range was found, which was not ever stated in previous researches. Furthermore this paper will discuss about negative role of diaphragm in transmissibility design. Then the design method proposed in this paper will be illustrated through experiment at measurements.

A New Type Speaker Utilizing a Magneto-rheological Fluid Diaphragm (자기유변유체 다이어프램을 이용한 새로운 타입의 스피커)

  • Park, Jhin Ha;Yoon, Ji Young;Kim, Seon Hye;Lee, Tae Hoon;Lee, Soo Hyuk;Choi, Seung Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.182-188
    • /
    • 2017
  • In this work, a new type speaker which features various resonant frequencies is proposed utilizing a magneto-rheological (MR) fluid and its performance is evaluated in terms of the change of the field-dependent sound pressure level. In order to achieve this goal, a whole concept of the speaker system is firstly discussed and subsequently a controllable diaphragm is made using MR fluid whose rheological properties such as viscosity are controllable by the magnitude of magnetic field. Then, the proposed speaker system consisting of the inner structure and the squeeze mode type of MR diaphragm is established in an anechoic room The effectiveness of the proposed speaker system is experimentally evaluated at two different conditions; with and without the magnetic field. It is shown from experimental tests that the sound pressure level at different sound source can be controlled which is not able to achieve using one conventional speaker system.