• 제목/요약/키워드: Diameter Measurement

검색결과 1,210건 처리시간 0.027초

평면 이미지 기법을 이용한 분무 특성 해석 (The Spray Characterization Using Planar Imaging Technique)

  • 이경진;정기훈;윤영빈;정경석;정인석
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.93-101
    • /
    • 2000
  • The characteristics of spray nozzle have been quantified with the measurement of fluorescence and Mie scattering images. To correct the attenuation of the incident light sheet, a sequential double-pass light sheet system and the geometrical averaging of two images was implemented. Quantitative mass flux distribution of spray was obtained from fluorescence image. 3-D image is reconstructed using 2-D radial images. Sauter mean diameter (SMD) distribution was determined using the ratio of fluorescence signal intensity and Mie scattering signal intensity and the values were quantified with PDP A data. The measurement of mass flux and SMD using planar imaging technique agee with PDP A data fairly well in the low density region. However, in dense region, there are significant errors caused by secondary scattering. It was found that the planar imaging technique provides many advantages over the point measurement technique, such as PDP A, and can be implemented for quantitative measurement, especially in low density region.

초음파유도 난포란 채취를 위한 기본 기술의 개발 I. 초음파상에 나타난 한우 난소, 난포 및 황체의 크기 측정 (Development of Basic Techniques for Ultrasound-guided Follicular Aspiration I. Measurement of Size of Ovaries, Follicles and Corpora Lutea of Korean Native Cows by Ultrasonography)

  • 최민철;강태영;조성근;최상용;손우진;이효종
    • 한국수정란이식학회지
    • /
    • 제12권2호
    • /
    • pp.203-209
    • /
    • 1997
  • This study was carried out to compare the actual size(length and height) of ovaries, follicles and corpora lutea of Korean native cow with those on sonograms. We used 3 different probes(3.5 MHz abdominal probe, 6.5 MHz transvaginal probe and 5.0 MHz transrectal probe) and a calipher for measurements of ovaries, follicles and corpora lutea on sonograms and actual size. Under water immersion, 157 ovaries were scanned with 3 probes and measured in actual size and compared each other. The average height and width of ovaries of Korean native cows were 17.40$\pm$3.99 and 34.23$\pm$6.02mm, respectively. In comparison of height, length of ovaries and preovulation follicles, we found that image with a transvaginal probe was nearly the same as the actual size(p<0.01), but with an abdominal probe the image was appeared larger than the actual size. In measurement(diameter) of preovulation follicles the transvaginal probe was proven to be more accurate to the actual size than other probes and in corpus luteum measurement all probes were accurate. In the comparison of number of follicles by different size ranges, there was no statistical difference in the count of follicles over 10 mm in diameter between the transvaginal probe and naked eyes.

  • PDF

심자도 측정을 위한 SQUID 센서 기술의 개발 현황 (Review of SQUID Sensors for Measuring Magnetocardiography)

  • 이용호;김진목;유권규;김기웅;권혁찬
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

대두입자가 분산된 두유에서 기름입자의 입도분포 측정 (The Measurement of Oil Globule Size Distribution in the Soymilk Suspended with the Soybean Particle)

  • 정제봉;윤석권;손헌수
    • 한국식품과학회지
    • /
    • 제22권4호
    • /
    • pp.369-372
    • /
    • 1990
  • 두유에는 기름의 양이나 입도를 분석하는데 장해를 주는 대두단백질, 미세한 대두입자들이 공존하고 있어서 기존의 microscopic image analysis, coulter counter, 또는 Photo-analysis 등의 사용이 많은 문제점을 노출했다. 본 실험에서 Stokes 법칙을 응용하여, 중력장과 원심력장하에서 homogeneous suspension과 cumulative method를 이용하여 입도분포를 분석했다. 선정된 두유에서 기하학적 평균지름은 중력장하에서는 $0.33{\mu}m$ 표준편차 $1.73{\mu}m$이고, 원심력 장에서는 평균지름은 $0.31{\mu}m$, 표준편차는 $1.81{\mu}m$으로, 매우 유사한 결과를 얻었다. 균질압이 유화안정성에 크게 영향을 주는 인자이기 때문에 균질압을 변화했을 때, 균질압이 높을수록 평균입도는 작은 쪽으로 이동하였으며, 입자의 분산 형태는 평균지름을 중심으로 밀도 있게 분포하는 쪽으로 변화하여, 균질압이 기름 입도분포에 영향을 미쳐 유화 안정과 깊은 관계가 있는 것을 확인하였다.

  • PDF

3D 프린팅용 UV 경화 수지의 조사량 및 항온수조 침적에 따른 수축률의 차이 (Difference between shrinkage rate of irradiation amount of 3D printing UV curable resin and shrinkage rate according to a constant temperature water bath)

  • 김동연
    • 대한치과기공학회지
    • /
    • 제42권2호
    • /
    • pp.113-120
    • /
    • 2020
  • Purpose: This study is to compare and analyze the shrinkage of the specimen after UV irradiation of UV cured resin at 5, 15, and 30 minutes. Methods: A cylindrical UV cured specimen was produced using a stainless steel mold. UV cured resin specimens were prepared in three groups: 5 minutes cured (5M), 15 minutes cured (15M), and 30 minutes cured (30M). The measurement was made in total 3rd. The measurement was made in total 3rd. The primary measurement was made after 24 hours using a digital measuring instrument. The 2nd and 3rd measurements were deposited in a constant temperature water bath and the shrinkage was measured. The measured data was calculated by referring to the ASTM C326 linear measurement calculation method. T-test and One-way ANOVA were performed to test the significance between groups. The post-test was conducted with Tukey (α=0.05). Results: When the inner diameter and the outer diameter of the three groups not placed in the water bath were compared and analyzed, the contraction was the smallest at 6.8% in the 5M group, and the contraction was the largest at 7.3% in the 30M group. In the outer diameter, the contraction of the 5M group was the smallest at 3.5%, and the contraction of the 30M group was the largest at 4.5%. Shrinkage decreased in all three groups immersed in a water bath for 3-7 days. Conclusion: In the UV cured resin specimen, the shrinkage increased as the amount of UV irradiation increased.

6MV 소형 x-선 beam 측정에 적합한 검출기의 조건에 관한 연구 (The study of detector condition proper to the measurement of 6MV small x-rays beam)

  • 유명진;도시홍
    • 센서학회지
    • /
    • 제8권3호
    • /
    • pp.219-225
    • /
    • 1999
  • 본 연구의 목적은 beam 지름이 12.5mm에서 40mm 까지의 소형 x-선에 대한 TMR, OAR, TSF를 전리함, 다이오드, 필름 및 TLD 등의 검출기로 측정하여 6MV 소형 x-선 beam 선량 측정에 적합한 검출기를 결정하였다. 가장 작은 beam인 지름 12.5mm beam의 TMR 값을 여러 가지 검출기로 측정한 결과 다이오드와 필름이 가장 우수하였으며 표준 TMR 값에 대한 오차 범위는 2% 이내였다. 그리고 이 다이오드와 필름은 OAR 측정 시공간 분해능이 뛰어났으며 이 두 검출기의 상대 비교에서 오차는 3% 이내였다. 이에 반해 전리함은 소형 beam의 TMR 및 OAR을 정밀하게 측정하는데 적합하지 않았다. beam 지름 12.5mm에서 40mm까지의 beam에 대한 TSF를 다이오드와 TLD로 측정한 결과 그 값은 $0.89{\sim}0.96$이었다. 그리고 beam 지름이 25mm 보다 크면 0.125cc 전리함 및 markus 전리함으로 측정한 TSF 값은 다이오드 및 TLD로 측정한 TSF 값과 잘 일치하였으며 그 오차 범위는 2% 이내였다.

  • PDF

지상 LiDAR를 활용한 침엽수림의 수고 및 흉고직경 측정 (Measurement of Tree Height and Diameter Using Terrestrial Laser Scanner in Coniferous Forests)

  • 고병준;박세익;박희정;이상현
    • 한국환경과학회지
    • /
    • 제31권6호
    • /
    • pp.479-490
    • /
    • 2022
  • This study was to evaluate the utilization of terrestrial light detection and ranging for forest inventory in coniferous forests. Heights and diameter of the stand trees were measured manually using the traditional measurement method and the method using terrestrial LiDAR. The results of two methods were compared and analyzed to evaluate accuracy and feasibility. The terrestrial LiDAR used fixed and handy types to compare the accuracy between different operational methods. Comparative analyses used a paired t-test and Bland-Altman plot analysis. In the case of tree heights, the average of difference between the traditional method and terrestrial LiDAR for each plot was 0.81 m, -0.07 m, and 0.13 m for fixed type; 2.88 m, 1.19 m, and 0.93 m for the handy type. In the case of tree diameter at breast height, the average value of the difference between traditional methods and terrestrial LiDAR for each plot was 0.13 cm, -0.66 cm, and -0.03 cm for fixed type; 2.36 cm, 2.13 cm, and 1.92 cm for the handy type. The values from the method using the fixed type was highly consistent with that using the traditional measurement methods; the average difference was closer to zero. The crown density influences the precision of the height measurement using terrestrial LiDAR in coniferous forests. Therefore, future studies should focus on verifying the accuracy of terrestrial LiDAR in forests and on expanding the utilization of terrestrial LiDARs according to their operational methods.

축류형 사이클론을 이용한 공기역학경과 광학직경 상관관계 분석에 관한 연구 (A Study on Correlation Analysis between Aerodynamic Diameter and Optical Diameter Using Axial Flow Cyclone)

  • 김은정;박경려;허지은;조철희;조윤행
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.155-164
    • /
    • 2023
  • APS (Aerodynamic Particle Sizer) and OPC (Optical Particle Counter) have been widely used to real-time measurement of indoor and outdoor aerosols. The APS measures the size distribution based on an aerodynamic diameter, while the OPC uses optical diameter to measure the size distribution of aerosols. Since obtaining a size distribution based on aerodynamic diameter is important to understand aerosol characteristics, lots of researcher had been developed experimental equations which can convert optical diameter into aerodynamic diameter. However, previous studies have conducted repeated experiments on particles having a single diameter. In this study, an experimental method of converting optical diameter into aerodynamic diameter through a single experiment was presented. The collection efficiencies of an axial cyclone were measured using APS and OPC at the same time, and the correlation equation between aerodynamic diameter and optical diameter was driven through a theoretical model. Using the proposed method, the size distribution of NaCl particles measured by OPC showed a high correlation with the size distribution obtained by APS (0.93 of R-squared value). In the tests conducted on ISO A1, A2, and A4 test particles, the converted OPC size distribution tended to be similar to the APS size distribution, and for each of test particles (ISO A1, A2, and A4), the R-squared values for the APS particle size distribution were 0.75, 0.86, and 0.89, respectively.

Development of Prototype Stylus Prototype for Large Optics Testing

  • Yang, Ho-Soon;Walker, David
    • Journal of the Optical Society of Korea
    • /
    • 제5권2호
    • /
    • pp.60-66
    • /
    • 2001
  • The authors discuss a prototype stylus profilometer designed to measure large optics. It consists of a low contact force type probe system, laser reference system, interferometric distance measurement system, and horizontal driving system. The probe contacts the surface ; the height and the horizontal distances of the measurement points are measured by the interferometer. The freely propagated laser beam provides the reference line during the measurement. The developed stylus profilometry shows only $\pm$60 nm of P-V error for the 157 mm diameter spherical mirror.