• Title/Summary/Keyword: Diagnostic ultrasound

Search Result 434, Processing Time 0.024 seconds

Diagnostic Performance of Radial Probe Endobronchial Ultrasound without a Guide-Sheath and the Feasibility of Molecular Analysis

  • Moon, Seong Mi;Choe, Junsu;Jeong, Byeong-Ho;Um, Sang-Won;Kim, Hojoong;Kwon, O Jung;Lee, Kyungjong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.4
    • /
    • pp.319-327
    • /
    • 2019
  • Background: Radial probe endobronchial ultrasound (R-EBUS), is effective for tissue diagnosis of lung lesions. We evaluated the diagnostic performance of R-EBUS both a guide-sheath and fluoroscopy and identified factors associated with accurate diagnosis. The feasibility of molecular and genetic testing, using specimens obtained by R-EBUS, was also investigated. Methods: The study retrospectively reviewed 211 patients undergoing R-EBUS without a guide-sheath and fluoroscopy, June 2016-May 2017. After excluding 27 patients of which the target lesion was not reached, 184 were finally included. Multivariate logistic regression was used, to identify factors associated with accurate diagnosis. Results: Among 184 patients, R-EBUS-guided biopsy diagnosed malignancy in 109 patients (59%). The remaining 75 patients (41%) with non-malignant results underwent additional work-ups, and 34 were diagnosed with malignancy. Based on final diagnosis, diagnostic accuracy was 80% (136/170), and sensitivity and specificity for malignancy were 76% (109/143) and 100% (27/27), respectively. In multivariate analysis, peripheral location (adjusted odds ratio [aOR], 3.925; 95% confidence interval [CI], 1.203-12.811; p=0.023), and central position of the probe (aOR, 2.435; 95% CI, 1.424-7.013; p=0.035), were associated with accurate diagnosis of malignancy. Molecular and genetic analyses were successful, in all but one case, with inadequate specimens. Conclusion: R-EBUS-guided biopsy without equipment, is effective for tissue diagnosis. Peripheral location and central position of the radial probe, were crucial for accurate diagnosis. Performance of molecular and genetic testing, using samples obtained by R-EBUS, was satisfactory.

A Diagnostic Feature Subset Selection of Breast Tumor Based on Neighborhood Rough Set Model (Neighborhood 러프집합 모델을 활용한 유방 종양의 진단적 특징 선택)

  • Son, Chang-Sik;Choi, Rock-Hyun;Kang, Won-Seok;Lee, Jong-Ha
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.6
    • /
    • pp.13-21
    • /
    • 2016
  • Feature selection is the one of important issue in the field of data mining and machine learning. It is the technique to find a subset of features which provides the best classification performance, from the source data. We propose a feature subset selection method using the neighborhood rough set model based on information granularity. To demonstrate the effectiveness of proposed method, it was applied to select the useful features associated with breast tumor diagnosis of 298 shape features extracted from 5,252 breast ultrasound images, which include 2,745 benign and 2,507 malignant cases. Experimental results showed that 19 diagnostic features were strong predictors of breast cancer diagnosis and then average classification accuracy was 97.6%.

Diagnosis of Cervical Tuberculous Lymphadenitis with Fine Needle Aspiration Biopsy Under Ultrasonographic Guides (초음파 유도하 세침 흡인 생검을 이용한 경부 결핵성 림프절염의 진단)

  • Suh Kwang-Wook;Park Cheong-Soo;Lee Jong-Tae;Lee Kwang-Gil
    • Korean Journal of Head & Neck Oncology
    • /
    • v.8 no.2
    • /
    • pp.91-96
    • /
    • 1992
  • The efficacy of the fine needle aspiration biopsy and cytological examination(FNABC) under ultrasonographic(US) guides for the diagnosis of cervical tuberculous lymphadenitis was assessed. There were one hundred and one patients whose neck masses were proven to be tuberculous lymphadenites with cytologic and/or histologic diagnosis. The physical characteristics shown by US revealed that all the cases were multiple lesions. Multiregional lesions were found in 80 cases(79.1%) and 19 cases(18.8%) were the bilateral lesion. The region V was the most prevalent site(n=69, 68.3%). US findings revealed 92 cases(90.9%) showed hypoechoic lesions and 9(9.1%) showed mixed echo patterns. There was no hyperechoic lesion (p<0.05). The sensitivity of FNABC was 77.2% and specificity was 99.0%. Diagnostic accuracy was 85.0%. There was no complication during the procedures. FNABC for the diagnosis of cervical tuberculous lymphadenitis is a safe, convinient procedure and has a high specificity. The pitfall of FNABC the low sensitivity, seemed to be compensated by US evaluations.

  • PDF

Retrospective Study of 143 Dogs with Alimentary Foreign Bodies (개에서 발생한 소화기계 이물에 대한 회고분석 - 143 증례)

  • Choi, Jihye;Keh, Seoyeon;Kim, Hyunwook
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.49-55
    • /
    • 2015
  • This study was retrospectively investigated the clinical features, diagnostic imaging, treatment, and prognosis of foreign bodies according to alimentary site and type of foreign body, in 143 dogs. Among 28 breeds, Maltese, Shih Tzu, and terriers including the Yorkshire terrier were presented with high prevalence. Bone was the most commonly identified (33%) foreign body regardless of alimentary site. Approximately 76% of foreign bodies were in the stomach and small intestine. All esophageal foreign bodies were diagnosed on survey radiography, with the most common location being the caudal thoracic esophageal segment. Further diagnostic examinations including ultrasonography or contrast studies were additionally performed to detect radiolucent foreign bodies and perforation or leakage in the stomach and intestine. However, most seeds could be identified based on the characteristic features such as hyperdense thin double lines and inner gas on survey radiography. In conclusion, complications such as peritonitis and intestinal perforation were mainly observed in cases with seeds and linear foreign bodies. Especially, fabric foreign bodies could be induce peritonitis and re-perforation with high prevalence after surgical correction.

Recent 9-year Experience With Biliary Atresia Utilizing a New Ultrasonographic Diagnostic Technique (최근 9년간의 담도폐쇄증 경험 - 새로운 초음파 진단법 소개 -)

  • Park, Woo-Hyun;Choi, Soon-Ok
    • Advances in pediatric surgery
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 2000
  • This paper reports our 9-year experience treating 34 infants with biliary atresia utilizing a new non-invasive diagnostic method, ultrasonographic "triangular cord"(TC) sign. The TC sign is present when there is visualization of a triangular or a band-like echogenicity just cranial to the portal vein. The ultrasonographic TC sign appears to be a simple, non-invasive, time-saving and useful tool in the diagnosis of biliary atresia. Sensitivity is 84 %. Active bile excretion was restored in 90 % of the patients who were treated between 31-60days, 78 % of those between 61-90 days, and 33 % of those being 91days or older. The incidence of postoperative cholangitis was 36 %. Construction of an antireflux valve in the Roux-en-Y loop did not affect the incidence of postoperative cholangitis(p=0.18). Among 34 infants with biliary atresia, 23(68 %) are alive for 2-102 months after operation, and 12 are alive for more than 5 years. Five-year estimate survival by Kaplan-Meier method was 66 %.

  • PDF

Diagnostic Imaging for Solitary Nodular Form of Alimentary Lymphoma in a Dog (개 고립 결절 형태의 소화기계 림프종에 대한 진단영상 1례)

  • Choi, Ji-Hye;Kim, Hyun-Wook;Jang, Jae-Young;Kim, Hye-Jin;Kim, Jun-Young;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.467-472
    • /
    • 2007
  • Alimentary lymphoma accounts for approximately 5% of neoplasm and diffuse lesion is more common than solitary nodular form in dogs. An eleven year-old male Yorkshire terrier was examined because of nonspecific gastrointestinal symptoms such as anorexia and vomiting for 10 days. An abdominal mass was palpated, which was originated from small intestinal wall in abdominal ultrasonography. Small intestine was obstructed by hypoechoic mass and lost normal layering and measured 24.5m. After fine-needle aspiration, septic peritonitis due to intestinal rupture occurred and emergency surgery was performed. Solitary mass was found in small intestine and diagnosed as alimentary lymphoma through histopathologic examination. Conclusively, abdominal ultrasonouaphy could verify the thickened bowel, loss of wall layering and decrease of motility and percutaneous ultrasound-guided fine-needle aspiration is considered as useful diagnostic technique, especially in nodular form of alimentary lymphoma.

Is it Possible to predict the Characteristics of Calcific Deposition in Calcific Tendinitis of Shoulder Joint? (단순 방사선 검사를 이용하여 석회성 건염에서 발생하는 석회 침착물의 성상에 대한 예측이 가능한가?)

  • Kim, Sung-Jae;Lee, Hee Jae;Lee, Kwang-Hyun;Park, Dong-Hyeok;Lee, Bong Geun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.77-83
    • /
    • 2014
  • Purpose: The purpose of current study was to evaluate the validity of the existing radiological classifications as a diagnostic modality for predicting characteristics of calcific deposition in calcific tendinitis of the shoulder joint. For that purpose, we determined the inter-observer reliability for evaluating diagnostic precisions of the classification and also evaluated diagnostic accuracy of predicting the toothpaste type calcific deposition. Materials and Methods: We performed retrospective study with total 26 patients surgically treated with calcific tendinitis of the shoulder joint from March 2010 to October 2013. Two independent observers reviewed preoperative radiographs of shoulder joints, and classified the characteristics of calcific depositions according to the criteria of Gartner, DePalma and Patte. Cohen's kappa were calculated for each classifications to evaluate inter-observer reliability. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio were determined for type of calcific depositions with Gartner type III, DePalma type I, and Patte type II for predicting toothpaste type calcific deposition. Results: The values of Cohen's kappa were the highest in the classification of Patte, 0.62, and the values for the classifications of DePalma and Gartner were 0.56 and 0.36, respectively. The sensitivities for predicting toothpaste type calcific deposition in Gartner Type III, DePalma type I and Patte type II were 83.3%, 91.7%, and 58.3%, respectively. Specificities were 85.7% 50.0% and 64%, positive likelihood ratios were 5.833, 1.833 and 1.633, negative likelihood ratios were 0.194, 0.167 and 0.648, and diagnostic odds ratios were 30.00, 11.00 and 2.52, respectively. Conclusion: There were no radiologic classifications of calcific tendinitis which has both high precision and accuracy. Further studies with other diagnostic modalities such as ultrasonography are needed for predicting characteristics of calcific deposition in calcific tendinitis of the shoulder joint.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

A Study on the Architectural Planning of the X-ray Unit in General Hospital (종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구)

  • Youn, Woo-Young;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

Usefulness of Preoperative Computed Tomography in Children with Clinically Suspected Appendicitis (소아 충수염 진단에 CT의 유용성)

  • Jun, Si-Youl
    • Advances in pediatric surgery
    • /
    • v.19 no.2
    • /
    • pp.57-65
    • /
    • 2013
  • The entity of negative appendectomies still poses a dilemma in chlidren. Focused computed tomography (CT) scanning has become the diagnostic test of choice in many hospitals. However, the impact of CT scans on the diagnosis in children is unknown exactly. The purpose of this study was to critically evaluate CT scans for the evaluation of acute appendicitis in children, to review utilization of this diagnostic test in our appendicitis population and to determine if diagnostic accuracy has improved. A retrospective analysis of efficacy of CT scan for diagnosis of appendicitis in children was conducted. Children undergoing appendectomy for acute appendicitis were reviewed from 2007 to 2012. Perforation and negative appendectomy (removal of a normal appendix) rates were determined by the final pathologic report. Statistical comparison were made using the $x^2$ test and significance was assigned at p < 0.05. Five hundred four appendectomies were performed. Mean age was $10.1{\pm}3.21$ years, and 62.7% were boys. Overall, 308 children (61.1%) underwent CT scanning, 100 (19.8%) had US performed, and 97 (19.2%) had no radiographic study. A pathologically normal appendix was removed in 8.7% (27 of 308) of CT patients, 9.0% (9 of 100) of US patients, and 11.3% (11 of 97) of patients without a study. The frequency of CT scanning increased from 29.7% (27 of 91) of all children in 2007 to 75.6% (59 of 78) in 2012, whereas utilization of US decreased from 30.8% (28 of 91) to 11.5% (9 of 78). During this time period the difference in the negative appendectomy rate did change significantly from 14% to 6%. Liberal use of CT scans in diagnosing appendicitis in children has resulted in a decreased negative appendectomy rate.