• Title/Summary/Keyword: Diagnostic ultrasound

Search Result 431, Processing Time 0.025 seconds

A home-based exercise program for temporomandibular joint osteoarthritis: pain, functionality, and joint structure

  • Macias-Hernandez, Salvador Israel;Morones-Alba, Juan Daniel;Tapia-Ferrusco, Irene;Velez-Gutierrez, Oscar Benjamin;Hernandez-Diaz, Cristina;Nava-Bringas, Tania Ines;Cruz-Medina, Eva;Toro, Lya Contreras-del;Soria-Bastida, Ma. de los Angeles
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.1
    • /
    • pp.50-58
    • /
    • 2022
  • Objectives: Osteoarthritis (OA) is the most prevalent and disabling joint disease in the world. Temporomandibular joint (TMJ) exercise is a widely used treatment and could be a beneficial and long-term tool for treating TMJ OA. The present study aims to evaluate the effects of therapeutic exercise in the conservative treatment of TMJ OA. Materials and Methods: A single-group experimental pre-post test was performed. We included patients who met the diagnostic criteria for TMJ OA. Outcome variables were pain intensity (visual analogue scale), functionality (Helkimo index), and structural changes (ultrasound). Follow-up periods were at months 1, 3, and 6. The intervention included a home-based program with thermotherapy, manual therapy, and therapeutic exercise during the entire follow-up period. Results: We included 15 patients and 26 joints, all women with a median age of 57 years (range, 49-62 years). Median change in pain intensity on joint palpation, mouth opening, and at rest at the first month was 47.5 mm, 51 mm, and 60 mm, respectively, and 48 mm, 49.5 mm, and 42.5 mm, at six months (P=0.001). The Helkimo index showed significant improvement in medians from baseline severe dysfunction (17 points) to minimal dysfunction at three and six months (2 points) (P=0.001). Ultrasound showed improved disc position. Conclusion: This study demonstrated significant improvements in pain, function, and joint disc position and represents a valuable tool for the long-term treatment of patients with TMJ OA.

Role of interventional endoscopic ultrasound in a developing country

  • Hasan Maulahela;Nagita Gianty Annisa;Achmad Fauzi;Kaka Renaldi;Murdani Abdullah;Marcellus Simadibrata;Dadang Makmun;Ari Fahrial Syam
    • Clinical Endoscopy
    • /
    • v.56 no.1
    • /
    • pp.100-106
    • /
    • 2023
  • Background/Aims: Endoscopic ultrasound (EUS) has become an essential diagnostic and therapeutic tool. EUS was introduced in 2013 in Indonesia and is considered relatively new. This study aimed to describe the current role of interventional EUS at our hospital as a part of the Indonesian tertiary health center experience. Methods: This retrospective study included all patients who underwent interventional EUS (n=94) at our center between January 2015 and December 2020. Patient characteristics, technical success, clinical success, and adverse events associated with each type of interventional EUS procedure were evaluated. Results: Altogether, 94 interventional EUS procedures were performed at our center between 2015 and 2020 including 75 cases of EUS-guided biliary drainage (EUS-BD), 14 cases of EUS-guided pancreatic fluid drainage, and 5 cases of EUS-guided celiac plexus neurolysis. The technical and clinical success rates of EUS-BD were 98.6% and 52%, respectively. The technical success rate was 100% for both EUS-guided pancreatic fluid drainage and EUS-guided celiac plexus neurolysis. The adverse event rates were 10.6% and 7.1% for EUS-BD and EUS-guided pancreatic fluid drainage, respectively. Conclusions: EUS is an effective and safe tool for the treatment of gastrointestinal and biliary diseases. It has a low rate of adverse events, even in developing countries.

Dynamic Contrast-Enhanced Ultrasound of Gastric Cancer: Correlation with Perfusion CT and Histopathology

  • Ijin Joo;Se Hyung Kim;Dong Ho Lee;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.781-790
    • /
    • 2019
  • Objective: To assess the relationship between contrast-enhanced ultrasound (CEUS) parameters and perfusion CT (PCT) parameters of gastric cancers and their correlation with histologic features. Materials and Methods: This prospective study was approved by our Institutional Review Board. We included 43 patients with pathologically-proven gastric cancers undergoing CEUS using SonoVue® (Bracco) and PCT on the same day. Correlation between the CEUS parameters (peak intensity [PI], area under the curve [AUC], rise time [RT] from 10% to 90% of PI, time to peak [TTPUS], and mean transit time [MTTUS]) and PCT parameters (blood flow, blood volume, TTPCT, MTTCT, and permeability surface product) of gastric cancers were analyzed using Spearman's rank correlation test. In cases of surgical resection, the CEUS and PCT parameters were compared according to histologic features using Mann-Whitney test. Results: CEUS studies were of diagnostic quality in 88.4% (38/43) of patients. Among the CEUS parameters of gastric cancers, RT and TTPUS showed significant positive correlations with TTPCT (rho = 0.327 and 0.374, p = 0.045 and 0.021, respectively); PI and AUC were significantly higher in well-differentiated or moderately-differentiated tumors (n = 4) than poorly-differentiated tumors (n = 18) (p = 0.026 and 0.033, respectively), whereas MTTCT showed significant differences according to histologic types (poorly cohesive carcinoma [PCC] vs. non-PCC), T-staging (≤ T2 vs. ≥ T3), N-staging (N0 vs. N-positive), and epidermal growth factor receptor expression (≤ faint vs. ≥ moderate staining) (p values < 0.05). Conclusion: In patients with gastric cancers, CEUS is technically feasible for the quantification of tumor perfusion and may provide correlative and complementary information to that of PCT, which may allow prediction of histologic features.

Clinical utility of endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling of patients with biliary tract cancer, especially with intrahepatic cholangiocarcinoma

  • Takafumi Yanaidani;Kazuo Hara;Nozomi Okuno;Shin Haba;Takamichi Kuwahara;Yasuhiro Kuraishi;Nobumasa Mizuno;Sho Ishikawa;Masanori Yamada;Tsukasa Yasuda
    • Clinical Endoscopy
    • /
    • v.57 no.3
    • /
    • pp.384-392
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is a standard diagnostic method for biliary tract cancer (BTC), and samples obtained in this manner may be used for comprehensive genomic profiling (CGP). This study evaluated the utility of EUS-TA for CGP in a clinical setting and determined the factors associated with the adequacy of CGP in patients with BTC. Methods: CGP was attempted for 105 samples from 94 patients with BTC at the Aichi Cancer Center, Japan, from October 2019 to April 2022. Results: Overall, 77.1% (81/105) of the samples were adequate for CGP. For 22-G or 19-G fine-needle biopsy (FNB), the sample adequacy was 85.7% (36/42), which was similar to that of surgical specimens (94%, p=0.45). Univariate analysis revealed that 22-G or larger FNB needle usage (86%, p=0.003), the target primary lesions (88%, p=0.015), a target size ≥30 mm (100%, p=0.0013), and number of punctures (90%, p=0.016) were significantly positively associated with CGP sample adequacy. Conclusions: EUS-TA is useful for CGP tissue sampling in patients with BTC. In particular, the use of 22-G or larger FNB needles may allow for specimen adequacy comparable to that of surgical specimens.

Discrepancy of Ultrasound-MR arthrography-Arthroscopy for the Diagnosis of Rotator Cuff Tear - Case report - (회전근 개 파열의 진단에서 초음파-자기공명 조영술-관절경의 불일치 - 증례 보고 -)

  • Oh, Chung Hee;Oh, Joo Han;Jo, Ki Hyun;Kim, Sae Hoon;Bin, Seung Woo;Gong, Hyun Sik
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2008
  • Ultrasonography (USG) is widely accepted diagnostic method for the rotator cuff tear. The availability, low cost, easy to access is main factors that favor USG as a primary diagnostic modality for various cuff disorders. We experienced a case of discrepancy between USG, MR arthrography (MRA) and arthroscopic examination. Seventy four year old female patient complained of right shoulder pain. USG depicted rotator cuff tear with the size of 1cm, and MRA demonstrated about 3cm sized tear. Complex massive tear with delamination of degenerated rotator cuff was identified in the arthroscopic examination. When we encounter a patient who has loss of rotator cuff power or severe symptom than findings of USG, MRA or repeat USG is warranted. We report a case of discrepancy between examination modalities with brief review of the literature.

  • PDF

Role of a Risk of Malignancy Index in Clinical Approaches to Adnexal Masses

  • Simsek, Hakki Sencer;Tokmak, Aytekin;Ozgu, Emre;Doganay, Melike;Danisman, Nuri;Erkaya, Salim;Gungor, Tayfun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7793-7797
    • /
    • 2014
  • Objective: The aim of this study was to evaluate predictive role of risk of malignancy index in discriminating between benign and malignant adnexal masses preoperatively. Methods: This retrospective study was conducted with a total of 569 patients with adnexal masses/ovarian cysts managed surgically at our clinic between January 2006 and January 2012. Obtained data from patient files were age, gravidity, parity, menopause status, ultrasound findings and CA125 levels. For all patients ultrasound scans were performed. For the assessment of risk of malignancy index (RMI) Jacobs' model was used. Histopathologic results of all patients were recorded postoperatively. Malignancy status of the surgically removed adnexal mass was the gold standard. Results: Of the total masses, 245 (43.1%) were malignant, 316 (55.5%) were benign and 8 (1.4%) were borderline. The mean age of benign cases was lower than malign cases ($35.2{\pm}10.9$ versus $50.8{\pm}13.4$, p<0.001). Four hundred and five of them (71.2%) were in premenopausal period. Malignant tumors were more frequent in postmenopausal women (81% versus 29%, p<0.001). All ultrasound parameters of RMI were statistically significantly favorable for malignant masses. In our study ROC curve analysis for RMI provided maximum Youden index at level of 163.85. When we based on cutoff level for RMI as 163.85 sensitivity, specificity, PPV, NPV was calculated 74.7%, 96.2%, 94% and 82.6%, respectively. Conclusions: RMI was found to be a significant marker in preoperative evaluation and management of patients with an adnexal mass, and was useful for referring patients to tertiary care centers. Although utilization of RMI provides increased diagnostic accuracy in preoperative evaluation of patient with an adnexal mass, new diagnostic tools with higher sensitivity and specificity are needed to discriminate ovarian cancer from benign masses.

Assessing the Potential of Thermal Imaging in Recognition of Breast Cancer

  • Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8619-8623
    • /
    • 2016
  • Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.

Should Korean Medicine doctors use modern diagnostic medical devices? Survey result of public perspectives (국민인식을 기초로 한의사의 현대 진단의료기기 사용 법제화 필요성에 대한 제언 : 설문조사를 중심으로)

  • Juchul Kim;Byoungcheun Hwang;Manki Hwang;Seungmin Kathy Lee;EunHee Yi;Jungtae Leem
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.94-105
    • /
    • 2022
  • Objectives: This study investigated public opinion on the use of modern diagnostic medical devices by Korean Medicine doctors. Methods: A questionnaire looking into perceptions on the use of modern medical devices was developed. It was distributed by a third party and data was collected. Results were analyzed through frequency analysis, chi-square analysis (χ2-test), frequency and cross analysis using R program. The measurement variable in the study was the respondent's perspectives and expectations on the use of modern diagnostic medical devices by Korean Medicine doctors. The maximum significance level was 0.05. Results: There were a total of 3,000 responses and 80.8% of the respondents replied that there is a need for government-level discussion on endowing rights to Korean Medicine doctors as supervisors for safety management of radiation generating devices. Also, 83.3% of the respondents agreed the use of ultrasound imaging equipment in Korean Medicine clinics should be legalized. Conclusions: According to this study, respondents strongly support the use of modern diagnostic medical devices by Korean Medicine doctors. This is the first study to investigate public opinion in this area and it provides a significant insight into the public needs and desires for a wider scope of practice for Korean Medicine in the healthcare system.

Image Classification of Thyroid Ultrasound Nodules using Machine Learning and GLCM (머신러닝과 GLCM을 이용하여 갑상샘 초음파영상의 결절분류에 관한 연구)

  • Ye-Na Jung;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.317-325
    • /
    • 2024
  • This study aimed to classify normal and nodule images in thyroid ultrasound images using GLCM and machine learning. The research was conducted on 600 patients who visited S Hospital in Busan and were diagnosed with thyroid nodules using thyroid ultrasound. In the thyroid ultrasound images, the ROI was set to a size of 50x50 pixels, and 21 parameters and 4 angles were used with GLCM to analyze the normal thyroid patterns and thyroid nodule patterns. The analyzed data was used to distinguish between normal and nodule diagnostic results using the SVM model and KNN model in MATLAB. As a result, the accuracy of the thyroid nodule classification rate was 94% for SVM model and 91% for the KNN model. Both models showed an accuracy of over 90%, indicating that the classification rate is excellent when using machine learning for the classification of normal thyroid and thyroid nodules. In the ROC curve, the ROC curve for the SVM model was generally higher compared to the KNN model, indicating that the SVM model has higher within-sample performance than the KNN model. Based on these results, the SVM model showed high accuracy in diagnosing thyroid nodules. This result can be used as basic data for future research as an auxiliary tool for medical diagnosis and is expected to contribute to the qualitative improvement of medical services through machine learning technology.

Diagnostic Performance of Radial Probe Endobronchial Ultrasound without a Guide-Sheath and the Feasibility of Molecular Analysis

  • Moon, Seong Mi;Choe, Junsu;Jeong, Byeong-Ho;Um, Sang-Won;Kim, Hojoong;Kwon, O Jung;Lee, Kyungjong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.4
    • /
    • pp.319-327
    • /
    • 2019
  • Background: Radial probe endobronchial ultrasound (R-EBUS), is effective for tissue diagnosis of lung lesions. We evaluated the diagnostic performance of R-EBUS both a guide-sheath and fluoroscopy and identified factors associated with accurate diagnosis. The feasibility of molecular and genetic testing, using specimens obtained by R-EBUS, was also investigated. Methods: The study retrospectively reviewed 211 patients undergoing R-EBUS without a guide-sheath and fluoroscopy, June 2016-May 2017. After excluding 27 patients of which the target lesion was not reached, 184 were finally included. Multivariate logistic regression was used, to identify factors associated with accurate diagnosis. Results: Among 184 patients, R-EBUS-guided biopsy diagnosed malignancy in 109 patients (59%). The remaining 75 patients (41%) with non-malignant results underwent additional work-ups, and 34 were diagnosed with malignancy. Based on final diagnosis, diagnostic accuracy was 80% (136/170), and sensitivity and specificity for malignancy were 76% (109/143) and 100% (27/27), respectively. In multivariate analysis, peripheral location (adjusted odds ratio [aOR], 3.925; 95% confidence interval [CI], 1.203-12.811; p=0.023), and central position of the probe (aOR, 2.435; 95% CI, 1.424-7.013; p=0.035), were associated with accurate diagnosis of malignancy. Molecular and genetic analyses were successful, in all but one case, with inadequate specimens. Conclusion: R-EBUS-guided biopsy without equipment, is effective for tissue diagnosis. Peripheral location and central position of the radial probe, were crucial for accurate diagnosis. Performance of molecular and genetic testing, using samples obtained by R-EBUS, was satisfactory.