• Title/Summary/Keyword: Diagnostic rate

Search Result 1,209, Processing Time 0.028 seconds

Comparison of the Legislation Applicable to Compare the use of Diagnostic Radiation Devices (진단용 방사선발생장치 이용에 적용되는 법제의 비교)

  • Ko, Jong-Kyung;Jeon, Yeo-Ryeong;Han, Eun-Ok;Cho, Pyong-Kon;Kim, Yong-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.277-286
    • /
    • 2015
  • Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been p rovisions a re necessary compared to t he analysis o f l egal content in o rder t o prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing characteristics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions. And it is applied differently depending on the purpose and the imaging target using the same diagnostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is expected to be necessary.

A STUDY ON THE RELIABILITY OF THE OPTICAL CARIES ACTIVITY TEST (광학적 치아우식활성 검사법의 신뢰도에 관한 연구)

  • Park, Cheol-Hong;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.615-623
    • /
    • 2006
  • The purpose of this study was to evaluate the specificity, sensitivity, and diagnostic power of caries activity test using LED fluorescence. The subjects of this study were 55 children of $6{\sim}7$ years old. LED light were irradiated to labial or buccal surface of all teeth. Fluorescence from initial carious lesion of teeth illuminated by an LED light was observed through barrier filter and the number of teeth showing lesion, size and position of lesion were counted. Streptococcus mutans colony counting and dDfFtT rate test were also done and their correlation was compared. And then specificity, sensitivity, diagnostic power of optical caries activity test using LED light were evaluated. 1. There was positive $correlation({\gamma}=0.43)$ between LED fluorescence test and Streptococcus mutans count(P<0.05). 2. When visual examination was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 100%, 76.1%, and 100%. 3. When dDfFtT rate was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 88.9%, 47.8%, and 95.7%. 4. When S. mutans colony counting was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 100%, 58.7%, and 100%. Considering the above results, optical caries activity test using LED light could be regarded as a practical method because of its close relationship with microbiological caries activity test.

  • PDF

Comparison of Cellular Features Diagnostic of Papillary Thyroid Carcinoma in Liquid-Based (Cell Scan 1500TM) Preparations and Conventional Smears

  • Lee, Jung Dal;Park, Yong Wook;Back, OunCheol;Jung, Pa Jong;Kim, Jong Yull
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.3
    • /
    • pp.108-113
    • /
    • 2013
  • The study compared the cytological features of papillary thyroid carcinoma (PTC) in liquid-based preparations (LBPs) and conventional Pap (CP) smears from fine needle aspiration (FNA), and assessed the feasibility of LBP using the Cell Scan $1500^{TM}$ processor on thyroid FNA samples. Thyroid FNA samples were obtained from 883 consecutive patients. Each sample was divided into two and used for LBPs and CP smears. All were screened independently in a double-blind manner. From the 883 cases, 95 cases were diagnosed as PTC in one or both types of preparation (10.8%). PTC was diagnosed via CP smears in 83 cases (87.4%) and via LBPs in 70 cases (73.7%). However, there were differences in categorization between the paired preparations: Twelve (12) PTCs were misinterpreted in CP smears and 25 PTCs in LBPs. There was a significant discrepancy in the rate of detection of the diagnostic features, with LBPs having a lower detection rate. One (1) case (1.2%) of CP smears and 16 cases (22.9%) of LBPs were categorized as unsatisfactory/nondiagnostic in a total of the 95 PTCs. To conclude, the detection rate of the diagnostic features of PTC is lower in Cell Scan 1500TM samples than in CP smears. However, there are some cases in which a diagnosis of PTC is made in LBPs, but not in CP smears. Therefore, definitive cancer diagnosis in thyroid FNA preparations is likely to result from agreement between direct smears and Cell Scan 1500TM preparations.

  • PDF

Open Lung Biopsy for Diffuse Infiltrative Lung Disease (미만성 폐질환에 대한 개흉적 폐생검)

  • 김남혁
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.1014-1018
    • /
    • 1995
  • To confirm diagnosis and to set proper therapeutic strategy, open lung biopsies were done in 57 patients who were suspected for diffuse interstitial lung disease from January 1985 to December 1994. Among them, 35 were male and 22 were female[M:F=l.6: 1 and mean age of the patients is 53.5$\pm$ 2.3[24-81 years. Tissue for histologic studies were obtained from left lung in 33, from right lung in 24according to the distributions of the pathology. Preoperative diagnostic work-up`s were chest X-ray, CT[HRCT scan, sputum study, bronchoscopy[BAL, TBLB and PTNA and all of them were unsuccessful to confirm diagnosis. In comparison of pulmonary function tests between preoperative and postoperative values, there were no significant differences in FVC, FEV1, FEV1/FVC[p 0.05 but in AaDO2[p[0.05 . Postoperative complications including atelectasis, wound infection, pulmonary edema and respiratory insnfficiency, were shown in 5 cases[8.8% , and two of them were died of respiratory failure and sepsis[mortality rate 3.5% . Pathologic diagnosis was confirmed in 53 cases postoperatively but it was undetermined in 4[diagnostic yield rate 93.0% . In comparison between preoperative clinical diagnosis and postoperative pathologic diagnosis, new diagnosis were made in 17 cases[29.8% and preoperative tentative diagnosis were confirmed histologically in 36 cases[63.2% . In 4 cases[7.0% , however, diagnoses were not confirmed after biopsies. Therapeutic plans were reset in 46 cases[80.7% in accordance with the final diagnosis.In conclusion, open lung biopsy is recommended for a specific diagnosis and proper therapeutic plan in diffuse interstitial lung diseases because of its high diagnostic yield Irate and it`s relatively low morbidity and mortality rate in these tompromised patents.

  • PDF

A Study on the agreement of Principal Diagnosis (주상병 일치도에 관한 연구 -1개 중소병원을 중심으로-)

  • Seo, Young-Suk;Kim, Yoo-Mi;Nam, Moon-Hee;Kang, Sung-Hong;Lim, Ji-Hye
    • Quality Improvement in Health Care
    • /
    • v.15 no.1
    • /
    • pp.123-133
    • /
    • 2009
  • Background : The principal diagnosis has been used in many different fields such as hospital statistics, medical research, insurance claim, national health statistics and so on. Some principal diagnoses have a relatively low level of reliability in the medium-sized hospitals. The purpose of this study is to identify the reliability level of principal diagnoses and to suggest ways to improve reliability of the principal diagnosis. Method : Data were collected from a medium-sized hospital located in Pusan. The discharge summaries on 323 patients who were discharged in January, 2008 and the outpatient summaries on 251 patients who visited the hospital on March 28, 2008 were collected, and descriptive analysis was performed using SPSS version 12.0K. Result : The findings are the followings: (1) the diagnostic consistency rate between medical records and doctors' was 92.0%; (2) the diagnostic consistency rate between medical records and insurance claims was 86.1%; (3) the diagnostic consistency rate between doctors' diagnoses and insurance claims was 80.2%. The evidence seems to indicate that some principal diagnoses have reliability problems in the medium-sized hospitals. Conclusion : The results of this study suggest the followings: (1) employees should be trained and supervision of hospital activities are needed; (2) network systems should be constructed for each department; (3) professions need to be fostered (4) doctors' awareness of medical records should be changed.

  • PDF

Clinical Features of Complicated Meckel's Diverticulum Requiring Operation in Children (소아에서 수술을 요한 멕켈게실의 임상상)

  • Lee, Seong-Cheol;Mok, Woo-Kyun;Seo, Jung-Min;Jung, Sung-Eun;Park, Kwi-Won;Kim, Woo-Ki
    • Advances in pediatric surgery
    • /
    • v.1 no.1
    • /
    • pp.33-39
    • /
    • 1995
  • The incidence of Meckel's diverticulum(MD) in general population has been assessed as 2 percent. The major complications of MD are bleeding, perforation, and intestinal obstruction. In spite that the complication rate of Meckel's diverticulum is relatively high(about 4.2% during a lifetime), the preoperative diagnostic rate of complicated MD is very low. Authors investigated the clinical characteristics of complicated MD to improve the diagnostic rate. 16 patients with complicated Meckel's diverticulum who were operated upon at the Department of Pediatric Surgery, Seoul National University Children's Hospital from June 1985 to December 1993 were reviewed. Among the 16 patients with complicated MD, 12 patients(75%) were under 2 year-old and male were predominant(88%). The most common complication was bleeding patients with bleeding MD (8 cases) were diagnosed preoperatively as MD. 8 patients with other complications(perforation : 4 cases, obstruction : 4 cases) could not be suspected as complicated MD except one patient who had previous history of melena. These patients were diagnosed after exploratory laparotomy under the various impression other than MD. Among 12 patients with ulcer related complications such as bleeding and perforation, heterotopic gastric mucosa was found in 11 patients. In conclusion, in any children with unexplained acute abdomen, especially under 2 years old, complicated MD must be included in differential diagnosis. In children with obscure lower gastrointestinal bleeding, $^{99m}Tc$-pertechnetate scintigraphy is a useful diagnostic tool to rule out bleeding MD.

  • PDF

Is the diagnosis of calcified laryngeal cartilages on panoramic radiographs possible?

  • Cagirankaya, Leyla Berna;Akkaya, Nursel;Akcicek, Gokcen;Dogru, Hatice Boyacioglu
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.121-125
    • /
    • 2018
  • Purpose: Detecting laryngeal cartilages (triticeous and thyroid cartilages) on panoramic radiographs is important because they may be confused with carotid artery calcifications in the bifurcation region, which are a risk factor for stroke. This study assessed the efficiency of panoramic radiography in the diagnosis of calcified laryngeal cartilages using cone-beam computed tomography (CBCT) as the reference standard. Materials and Methods: A total of 312 regions(142 bilateral, 10 left, 18 right) in 170 patients(140 males, 30 females) were examined. Panoramic radiographs were examined by an oral and maxillofacial radiologist with 11 years of experience. CBCT scans were reviewed by 2 other oral and maxillofacial radiologists. The kappa coefficient(${\kappa}$) was calculated to determine the level of intra-observer agreement and to determine the level of agreement between the 2 methods. Diagnostic indicators(sensitivity, specificity, accuracy, and false positive and false negative rates) were also calculated. P values <.05 were considered to indicate statistical significance. Results: Eighty-two images were re-examined to determine the intra-observer agreement level, and the kappa coefficient was calculated as 0.709 (P<.05). Statistically significant and acceptable agreement was found between the panoramic and CBCT images (${\kappa}=0.684$ and P<.05). The sensitivity, specificity, diagnostic accuracy rate, the false positive rate, and the false negative rate of the panoramic radiographs were 85.4%, 83.5%, 84.6%, 16.5%, and 14.6%, respectively. Conclusion: In most cases, calcified laryngeal cartilages could be diagnosed on panoramic radiographs. However, due to variation in the calcifications, diagnosis may be difficult.

Study on Body Constitution and Disease Symptoms and Signs (논체질여병증(论体质与病证))

  • Cui, Zheng-Zhi;Cui, Ming-Hua
    • Journal of Korean Medical classics
    • /
    • v.22 no.4
    • /
    • pp.241-247
    • /
    • 2009
  • Body constitution research in Korean traditional medicine adopt the diagnosis and treatment theory of "image-differentiation[body constitution differentiation, disease differentiation] in combination with syndrome differentiation diagnostic model and symptoms and signs of herbal property belong to image" as its core, which is key national medical science research project of State Administration of Traditional Chinese Medicine, the project brought up 4 key scientific problem ? body constitution differentiation theory, correlation theory of body constitution and disease, body constitution adjustable theory and symptoms and signs of herbal property belong to image theory. In body constitution pathology, it brought up "correlation between body constitution and symptoms", "differentiation between body constitution and symptoms" which increase the diagnostic level and diagnostic accuracy rate. In the condition of pathology, it obviously has low reliability according to body constitution differentiation, sometimes happen the description not comply with body constitution and disease symptoms, which lead to decrease the clinic diagnostic and treatment level, treatment effect not satisfying too. Now taking 4 key scientific achievement as criterion to illustrate the body constitution and disease symptoms.

  • PDF

The Characteristics of Sasang Constitution from the Result of Regular Medical Inspection (한방건강검진 결과에 따른 체질별 특성연구)

  • Kang, Jun-Ho;Kim, Eu-Gene;Cha, Yun-Yeop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.3
    • /
    • pp.91-100
    • /
    • 2009
  • Objectives : The purpose of this study was to find the characteristics of Sasang Constitution, Soeumin, Soyangin and Taeumin, Using Regular Medical Inspection. Methods : Subjects of our study were 325 cases who took regular medical inspection. We collected the data of body composition analysis, 7-zone-diagnostic system, blood analysis, and analyzed by Sasang Constitution, Soeumin, Soyangin and Taeumin. Results and Conclusions : 1. In body composition analysis, Taeumin was significantly higher than Soeumin and Soyangin about soft lean mass, body fat mass, waist-hip ratio, body water index, body mass index and basal metabolic rate. In blood analysis, Taeumin was significantly highest about total protein, albumin, GPT, hemoglobin, WBC, triglyceride. In 7-zone-diagnostic system, Taeumin had the highest level at Zone 1, 2. 2. Taeumin had more significant differences than other Sasang constitutions about the parameters of regular medical inspection. 3. Body composition analysis had the most parameters that showed differences among the constitutions, followed by blood analysis and 7-zone-diagnostic system.

Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Jijo Varghese;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.169-179
    • /
    • 2023
  • Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52-0.90) and strict criteria (OR, 0.58; 95% CI, 0.46-0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76-1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.