• Title/Summary/Keyword: Diagnostic methods

Search Result 4,200, Processing Time 0.043 seconds

Serial Changes of Serum Thyroid-Stimulating Hormone after Total Thyroidectomy or Withdrawal of Suppressive Thyroxine Therapy in Patients with Differentiated Thyroid Cancer (분화성 갑상선 암 환자에서 갑상선 전절제술후 또는 갑상선 호르몬 억제 요법 중단에 따른 갑상선 자극호르몬의 변화)

  • Bae, Jin-Ho;Lee, Jae-Tae;Seo, Ji-Hyoung;Jeong, Shin-Young;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ahn, Byeong-Cheol;Sohn, Jin-Ho;Kim, Bo-Wan;Park, June-Sik;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.516-521
    • /
    • 2004
  • Background: Radioactive iodine (RAI) therapy and whole-body scanning are the fundamentals of treatment and follow-up of patients with differentiated thyroid cancer. It is generally accepted that a Thyroid-Stimulating Hormone (TSH) level of at least 30 ${\mu}U/ml$ is a prerequisite for the effective use of RAI, and that it requires 4-6 weeks of off-thyroxine to attain these levels. Because thyroxine withdrawal and the consequent hypothyroidism are often poorly tolerated, and occasionally might be hazardous, it is important to be certain that these assumptions are correct. We have measured serial changes in serum TSH after total thyroidectomy or withdrawl of thyroxine in patients with thyroid cancer. Subjects and Methods: Serum TSH levels were measured weekly after thyroidectomy in 10 patients (group A) and after the discontinuation of thyroxine in 12 patients (group B). Symptoms and signs of hypothyroidism were also evaluated weekly by modified Billewicz diagnostic index. Results: By the second week, 78% of group A patients and 17% of group B patients had serum TSH levels ${\geq}30{\mu}U/ml$. By the third week, 89% of group A patients and 90% of group B patients had serum TSH levels ${\geq}30{\mu}U/ml$. By the fourth week, all patients in two groups achieved target TSH levels and there were no overt hypothyroidism. Conclusion: in all patients, serum TSH elevated to the target concentration (${\geq}30{\mu}U/ml$) within 4 weeks without significant manifestation of hypothyroidism. The schedule of RAI administration could be adjusted to fit the needs and circumstances of individual patients with a shorter preparation period than the conventional.

A Study on the Psychosocial Characteristics and Quality of Life in Functional Gastrointestinal Disorders (기능성위장질환 환자들의 정신사회적 특성 및 삶의 질의 관계에 관한 연구)

  • Kim, So-Won;Jang, Seung-Ho;Ryu, Han-Seung;Choi, Suck-Chei;Rho, Seung-Ho;Lee, Sang-Yeol
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.27 no.1
    • /
    • pp.25-34
    • /
    • 2019
  • Objectives : This study aimed to compare the psychosocial characteristics among patients with functional gastrointestinal disorder (FGID), adults with functional gastrointestinal symptoms, and normal control group and investigate factors related to quality of life (QoL) of FGID patients. Methods : 65 patients diagnosed with FGID were selected. 79 adults were selected as normal control group based on the Rome III diagnostic criteria, and 88 adults who showed functional gastrointestinal symptoms were selected as "FGID positive group". Demographic factors were investigated. Psychosocial factors were evaluated using the Korean-Beck Depression Inventory-II, Korean-Beck Anxiety Inventory, Korean-Childhood Trauma Questionnaire, Multi-dimensional Scale of Perceived Social Support, Connor-Davidson Resilience Scale and WHO Quality of Life Assessment Instrument Brief Form. A one-way ANOVA was used to compare differences among groups. Pearson correlation test was used to analyze correlations between QoL and psychosocial factors in patients with FGID. Results : There were group differences in the education level. Depression (F=29.012, p<0.001), anxiety (F=27.954, p<0.001) and Childhood trauma (F=7.748, p<0.001) were significantly higher in FGID patient group than in both FGID-positive and normal control group. Social support (F=5,123, p<0.001), Resilience (F=9.623, p<0.001) and QoL (F=35.991, p<0.001) were significantly lower in the FGID patient group than in others. QoL of FGID patients showed a positive correlation with resilience (r=0.475, p<0.01), and showed a negative correlation with depression (r=-0.641, p<0.01), anxiety (r=-0.641, p<0.01), and childhood trauma (r=-0.278, p<0.05). Conclusions : FGID patients have distinctive psychosocial factors compared to the both FGID-positive and normal control group. Therefore, the active interventions for psychosocial factors are required in the treatment of patients with FGID.

Preliminary Report of the $1998{\sim}1999$ Patterns of Care Study of Radiation Therapy for Esophageal Cancer in Korea (식도암 방사선 치료에 대한 Patterns of Care Study ($1998{\sim}1999$)의 예비적 결과 분석)

  • Hur, Won-Joo;Choi, Young-Min;Lee, Hyung-Sik;Kim, Jeung-Kee;Kim, Il-Han;Lee, Ho-Jun;Lee, Kyu-Chan;Kim, Jung-Soo;Chun, Mi-Son;Kim, Jin-Hee;Ahn, Yong-Chan;Kim, Sang-Gi;Kim, Bo-Kyung
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.79-92
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: For the first time, a nationwide survey in the Republic of Korea was conducted to determine the basic parameters for the treatment of esophageal cancer and to offer a solid cooperative system for the Korean Pattern of Care Study database. $\underline{Materials\;and\;Methods}$: During $1998{\sim}1999$, biopsy-confirmed 246 esophageal cancer patients that received radiotherapy were enrolled from 23 different institutions in South Korea. Random sampling was based on power allocation method. Patient parameters and specific information regarding tumor characteristics and treatment methods were collected and registered through the web based PCS system. The data was analyzed by the use of the Chi-squared test. $\underline{Results}$: The median age of the collected patients was 62 years. The male to female ratio was about 91 to 9 with an absolute male predominance. The performance status ranged from ECOG 0 to 1 in 82.5% of the patients. Diagnostic procedures included an esophagogram (228 patients, 92.7%), endoscopy (226 patients, 91.9%), and a chest CT scan (238 patients, 96.7%). Squamous cell carcinoma was diagnosed in 96.3% of the patients; mid-thoracic esophageal cancer was most prevalent (110 patients, 44.7%) and 135 patients presented with clinical stage III disease. Fifty seven patients received radiotherapy alone and 37 patients received surgery with adjuvant postoperative radiotherapy. Half of the patients (123 patients) received chemotherapy together with RT and 70 patients (56.9%) received it as concurrent chemoradiotherapy. The most frequently used chemotherapeutic agent was a combination of cisplatin and 5-FU. Most patients received radiotherapy either with 6 MV (116 patients, 47.2%) or with 10 MV photons (87 patients, 35.4%). Radiotherapy was delivered through a conventional AP-PA field for 206 patients (83.7%) without using a CT plan and the median delivered dose was 3,600 cGy. The median total dose of postoperative radiotherapy was 5,040 cGy while for the non-operative patients the median total dose was 5,970 cGy. Thirty-four patients received intraluminal brachytherapy with high dose rate Iridium-192. Brachytherapy was delivered with a median dose of 300 cGy in each fraction and was typically delivered $3{\sim}4\;times$. The most frequently encountered complication during the radiotherapy treatment was esophagitis in 155 patients (63.0%). $\underline{Conclusion}$: For the evaluation and treatment of esophageal cancer patients at radiation facilities in Korea, this study will provide guidelines and benchmark data for the solid cooperative systems of the Korean PCS. Although some differences were noted between institutions, there was no major difference in the treatment modalities and RT techniques.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

The Three Types of Clinical Manifestation of Cow's Milk Allergy with Predominantly Intestinal Symptoms (위장관 증세 위주로 발현하는 영유아기 우유 알레르기 질환의 3가지 임상 유형에 관한 고찰)

  • Lee, Jeong-Jin;Lee, Eun-Joo;Kim, Hyun-Hee;Choi, Eun-Jin;Hwang, Jin-Bok;Han, Chang-Ho;Chung, Hai-Lee;Kwon, Young-Dae;Kim, Yong-Jin
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.1
    • /
    • pp.30-40
    • /
    • 2000
  • Purpose: During the first year of life, cow's milk protein is the major offender causing food allergy. Cow's milk allergy (CMA) affects 2~7% of infants, of which approximately one-half show predominantly gastrointestinal symptoms. We studied the clinical types of cow's milk allergy with predominantly gastrointestinal symptoms (CMA-GI) of childhood. Methods: The retrospective study was performed on 30 (male 22, female 8) patients who had diagnosed as CMA-GI during 2 years and 3 months from March 1995 to June 1997. Results: 1) Children with CMA-GI presented in the three types of clinical manifestation on the basis of time to reaction to milk ingestion: Quick (Q) onset (5 cases), Slow (S) onset (20 cases), Quick & Slow (Q&S) (5 cases). 2) Age on admission of the three groups was significantly different (p<0.05): (Q onset: $81.4{\pm}67.1$ days, S onset: $31.9{\pm}12.7$ days, Q&S: $366.0{\pm}65.0$ days). Although the body weight at birth was 10~95 percentile in all patients, body weight on admission was different: (Q onset: 10~50 percentile, S onset: below 10 percentile, Q&S: 10~25 percentile). S onset group was significantly different compared with other groups (p<0.05) and 90% of this one was failure to thrive below 3 percentile. 3) Peripheral leukocyte counts were as followings: (Q onset: $5,700{\sim}12,300/mm^3$, S onset: $10,000{\sim}33,400/mm^3$, Q&S: $5,200{\sim}14,900/mm^3$). Slow onset group was significantly different compared with other groups (p<0.05). Serum albumin levels on admission were as followings: (Q onset: $4.2{\pm}0.4\;g/dl$, S onset: $3.0{\pm}0.3\;g/dl$, Q&S: $4.0{\pm}0.3\;g/dl$). S onset group was significantly different compared with other groups (p<0.05) and 85% of this one was below 3.5 g/dl. 4) Although morphometrical analysis on small intestinal mucosa did not show enteropathy in Q onset and Q&S groups, all cases of S onset revealed enteropathy: 45% of this one showed subtotal villous atrophy, 55 % showed partial villous atrophy. 5) Allergic reaction test to other foods was not performed in S onset group because of ethical problem and high risk in general condition. In Q onset group, allergic reaction to one or two other foods: soy formula, weaning formula and eggs. Q&S goup revealed allergic reactions to several foods or to most of all foods except protein hydrolysate formula: eggs, potatos, some kinds of sea food, apples, carrots, beef and chicken. 6) Serum IgE level, peripheral eosinophil counts, milk RAST, soy RAST, skin test were not significantly different among groups. Conclusion: CMA-GI may present in three clinical ways on the basis of time to reaction to milk ingestion, typical clinical findings and morphologic changes in the small bowel mucosal biopsy specimens. This clinical subdivision might be helpful in diagnostic and therapeutic approaches in CMA-GI. Early suspicion is mandatory especially in S onset type because of high risks with malnutrition and enteropathy.

  • PDF

Internet Addiction in Adolescents and its Relation to Sleep and Depression (청소년의 인터넷 중독 : 수면, 우울과의 관련성)

  • Song, Ho-Kwang;Jeong, Mi-Hyang;Sung, Da-Jung;Jung, Jung-Kyung;Choi, Jin-Sook;Jang, Yong-Lee;Lee, Jin-Seong
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.2
    • /
    • pp.100-108
    • /
    • 2010
  • Objectives: "Internet-addiction" came into common use not only in clinical setting but also in everyday life. But, pathophysiology and diagnostic criteria of the internet addiction remain unknown. Because adolescents are in developing period, they might be vulnerable to the internet addiction, depression and sleep-related problem. The objectives of this study were to investigate the characteristics of internet addiction and its association with sleep pattern and depression in Korean adolescence. Methods: Subjects were 799 middle and high school students in Seoul, Korea. We administered a self-reported questionnaire including socio-demographic data, Korean versions of Young's Internet Addiction Scale (YIAS), Pittsburgh Sleep Quality Index (PS-QI), the Center for Epidemiologic Studies for Depression Scale (CES-D) and questions about internet using patterns. Data of 696 subjects were included in analysis. Chi-square tests were used to analyze proportional differences, and ANOVA with post-hoc tests were used to analyze differences among groups. Partial correlation analyses were performed to analyze the correlation of internet addiction with other variables (two-tailed, p<0.05). Results: Of the 696 participants (grade 2 of middle school; M2 135 vs. grade 1 of high school; H1 238 vs. grade 2 of high school; H2 323), 2.0% (n=14) were internet-addicted (IA), 27.7% (n=193) were over-using (OU) and 70.3% (n=489) were not-addicted (NA). The mean scores of YIAS, PSQI and CES-D scores were 35.24${\pm}$12.78, 5.53${\pm}$3.04 and 16.72${\pm}$8.69, respectively. In higher grade students, average total sleep time was shorter (M2 426.20${\pm}$67.68 min. vs. H1 380.47${\pm}$62.57 min. vs. H2 354.67${\pm}$73.37 min., F=51.909, p<0.001), and PSQI (4.69${\pm}$3.14 vs. 5.42${\pm}$3.15 vs. 5.97${\pm}$2.83, F=8.871, p<0.001) CES-D (13.53${\pm}$8.37 vs. 16.96${\pm}$8.24 vs. 17.87${\pm}$8.84, F=12.373, p<0.001) scores were higher than those of lower grade students. Comparing variables among IA, OU and NA groups, computer using time not for study (96.36${\pm}$63.31 min. vs. 134.92${\pm}$86.79 min. vs. 213.57${\pm}$136.87 min., F=34.287, p<0.001) and portable device using time not for study (84.22${\pm}$79.11 min. vs. 96.97${\pm}$91.89 min. vs. 152.31${\pm}$93.64 min., F= 5.400, p=0.005) were different among groups. PSQI (5.26${\pm}$2.97 vs. 6.08${\pm}$2.97 vs. 7.50${\pm}$4.41, F=8.218, p<0.001) and CES-D scores (15.40${\pm}$8.08 vs. 19.05${\pm}$8.42 vs. 30.43${\pm}$13.69, F=32.692, p<0.001) were also different among groups. YIAS score were correlated with computer using time not for study (r=0.356, p<0.001) and portable device using time not for study (r= 0.136, p<0.001). PSQI score (r=0.237, p<0.001) and CES-D score (r=0.332, p<0.001). YIAS score and PSQI score (r=0.131, p= 0.001), YIAS and CES-D score (r=0.265, p<0.001), PSQI score and CES-D score (r=0.357, p<0.001) were correlated each other. Conclusion: These results suggested that adolescents' internet-addiction was correlated with not only computer and portable device using time not for study but also depression and sleep-related problems. We should pay attention to depression and sleep-related problems, when evaluating internet-addiction in adolescents.

  • PDF

The study for the roles of intratracheally administered histamine in the neutrophil-mediated acute lung injury in rats: (호중구를 매개하는 백서의 급성 폐손상의 병리가전에 있어 기도내로 투여한 히스타민의 역활에 관하여)

  • Koh, Youn-Suck;Hybertson, Brooks M.;Jepson, Eric K.;Kim, Mi-Jung;Lee, In-Chul;Lim, Chae-Man;Lee, Sang-Do;Kim, Dong-Soon;Kim, Won-Dong;Repine, John E.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.308-322
    • /
    • 1996
  • Background : Neutrophils are considered to play critical roles in the development of acute respiratory distress syndrome. Histamine, which is distributed abundantly in lung tissue, increases the rolling of neutrophills via increase of P-selectin expression on the surface of endothelial cells and is known to have some interrelationships with IL-1, IL-8 and TNF-$\alpha$. We studied to investigate the effect of the histamine on the acute lung injury of the rats induced by intratracheal insufflation of TNF-$\alpha$ which has less potency to cause lung injury compared to IL-1 in rats. Methods : We intratracheally instilled saline or TNF(R&D, 500ng), IL-1(R&D, 50ng)or histamine of varius dose(1.1, 11 and $55\;{\mu}g/kg$) with and without TNF separately in Sprague-Dawley rats weighing 270-370 grams. We also intratracheally treated IL-1(50ng) along with histamine($55\;{\mu}g/kg$). In cases, there were synergistic effects induced by histamine on the parameters of TNF-induced acute lung injury, antihistamines(Sigma, mepyramine as a $H_1$ receptor blockade and ranitidine as a $H_2$ receptor blockade, 10 mg/kg in each)were co-administered intravenously to the rats treated TNF along with histamine($1.1\;{\mu}g/kg$) intratraeheally. Then after 5 h we measured lung lavage neutrophil numbers, lavage cytokine-induced neutrophil chemoattractants(CINC), lung myeloperoxidase activity(MPO) and lung leak. We also intratracheally insufflated TNF with/without histamine($11\;{\mu}g/kg$), then after 24 h measured lung leak in rats. Statistical analyses were done by Kruskal-Wallis nonparametric ANOVA test with Dunn's multiple comparison test or by Mann-Whitney U test. Results : We found that rats given TNF, histamine alone(11 and $55\;{\mu}g/kg$), and TNF with histamine(l.1, 11, and $55\;{\mu}g/kg$) intratracheally had increased (p<0.05) lung MPO activity compared with saline-treated control rats. TNF with histamine $11\;{\mu}g/kg$ had increased MPO activity (P=0.0251) compared with TNF-treated rats. TNF and TNF with histamine(1.1, 11, and $55\;{\mu}g/kg$) intratracheally had all increased (p<0.05) lung leak, lavage neutophil numbers and lavage CINC activities compared with saline. TNF with histamine $1.1\;{\mu}g/kg$ had increased (p=0.0367) lavage neutrophil numbers compared with TNF treated rats. But there were no additive effect of histamine with TNF compared with TNF alone in acute lung leak on 5 h and 24 h in rats. Treatment of rats with the $H_1$ and $H_2$ antagonists resulted in inhibitions of lavage neutrophil accumulations and lavage CINC activity elevations elicited by co-treated histamine in TNF-induced acute lung injury intratracheally in rats. We also found that rats given IL-1 along with histamine intratracheally did not have increase in lung leak compared with IL-1 treated rats. Conclusion : Histamine administered intratracheally did not have synergistic effects on TNF-induced acute lung leak inspite of additive effects on increase in MPO activity and lavage neutrophil numbers in rats. These observations suggest that instilling histamine intratracheally would not play synergistic roles in neutrophil-mediated acute lung injury in rats.

  • PDF

A Study of Mac(脈)-Theory and Change of Mac(脈)-Diagnosis in Whang Di Nei Qing(黃帝內經) (황제내경(黃帝內經)의 맥(脈) 이론(理論)과 진맥법(診脈法)의 변화(變化)에 관(關)한 연구(硏究))

  • Ra, Kyoung-Chan;Park, Hyun Kook
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.73-105
    • /
    • 1993
  • To say nothing of the orient and the west, the human beings discover the method of Jin Mac(診脈) by the way that observe disease. But oriental medicine devise special method of Jin Mac(診脈) in the study of Kyoung Mac(經脈). Although sip-ei Kyoung Mac Jin(十二經脈診), Sam Bu Gu Who Jin(三部九候診), In Young Mac Gu Jin(人迎脈口診), Chon Kwan Chuck Jin(寸關尺診) namely Yuk Bu Jung Wee Jin Mac (六部定位診脈) that is used today are devised, it has changed naturally by the changing treatment and the introduction of Yuin Yang(陰陽) and five element(五行). Many methods dg Jin Mac(診脈), it had not developped successing alternative, it had developped of declined by it's own way. 1. Results for the birth of Mac(脈) 1) Mac(脈), it means Kyoung Mac(經脈), at first entirelly Mac(脈), is seized a blood vessel that flows in the body. As presumed today, after finding many acupunture point, a general idea of Mac(脈) is not maked by the line that connect point and point, it connect between acupunture point and acupunture point. 2) Like blood flows in Hyul Mac(血脈), Gie(氣) flows in Kyoung Mac(經脈). The two things relate deeply each other. In a general idea or actrally Kyoung Rak(經洛), the two things sometimes accord, sometimes seperate, sometimes mix alternative. 3) Hyul Mac(血脈) and Kyoung Mac(經脈), we call it Mac(脈) entirely Kyoung Mac(經脈), is a way that manifest disease through Kyoung Mac(經脈) or a boundary that disease belongs to it method of Mac Jin(脈診) individual that disease of Kyoung Mac(經脈) is diagnosed by the jumping situation of Hyul Mac(血脈). 4) In method of Moxa, athough the pathology and the diagnostic of Mac(脈) are created by finding Mac(脈). Finding acupunture have opportunitty fot Mac Jin(脈診) and treatment. 2. Results of Kyoung Mac Mac Jin(經脈脈診) 1) In theory of kyoung Rak(經洛), disease are resumed for malfunction of Young Wee(榮衛) that flows in Kyung Rak(經洛). So to speak, in treatment of Kyoung Rak area, the purpose of diagnosis observe the situation of disease and cause. For fitting the purpose of diagnosis, the dead had esatablised four-diagnosis method mangMunMnnJeul(望聞問切), in four-diagnosis(四診法), the core is Mac Jin(脈診). 2) sip-ei Kyoung Mac Mac Jin(十二經脈診) had existed as Kyoung Mac Mac Jin(經脈脈診), it precedes Sam Bu Gu Who Jin(三部九候診). In Young Ki Gu Mac(人迎脈口診). 3) Although Bu Yang Mac(趺陽脈), So Um Mac(少陰脈) is a part of Sip-ei Kyoung Mac(十二經脈診), they developped especially because they located in the point of Won Hyul(原穴) and they are convenient for diagnose. 4) Sip-ei Kyoung Mac Mac Jin(十二經脈診), which belongs to Bu Yang Mac(趺陽脈) and So Urn Mac(少陰脈), is not important for the comming age medical books compared with Mac Kyoung(脈經). 3. Results gor Sam Bu Gu Who Jin(三部九候診) 1) Mac Jin(脈診) of Sam Bu Gu Who(三部九候), which is noted in the theory of Sam Bu Gu Who(三部九候診) of So Mun(素問), belongs to Kyoung Mac Mac Jin's(經脈脈診) geneology, Sip-ei Kyoung Mac Mac Jin(十二經脈診) is arranged, simplicated by the idealogy three talents(三才思想) in the heaven and the earth. 2) What Sam Bu Gu Jin(三部九候診) is regardded as very important in So Mun(素問), the editor of So Mun(素問) recognize the meaning that one discover disease early in this method of diagnosis. 3) After Young chu(靈樞), Nan Kyoung(難經) it is lacked the method of Sam Bu Gu Who Jin(三部九候診) in the books that treatment has changed. Sam Bu Gu Who Jin(三部九候診) based on actually clinic appropriate. 4. results for In Young Mac Gu Jin(人迎脈口診) 1) In Young Mac Gu Jin(人迎脈口診) is the method of comparative Mac Jin(脈診) according to the theory of Yin Yang(陰陽), it is presumed after Sam Bu Gu Who Jin(三部九候診), it had perished in parallel with the development of the theory of five elelment(五行). The development of the acupunture, the perishment of the treatment of negative(刺絡). 2) In Young Mac Gu Jin(人迎脈口診), Wang Suk Wha(王叔和) recreated that the left is In Young(人迎), the right is Kie Gu(氣口). In future generations by Jin Mu Taek(陳無擇) who is the writer of Sam In Bang(三因方). In Young Mac Gu Jin(人迎脈口診) is a measure for disease which classify it's inside and outside cause. 5. Results for Chon Gu Mac Jin(寸口脈診) 1) What we say Mac Jin(脈診) of Chon Gu(寸口) two means are used in commn. First case, we simply say the area of Chon Gu(寸口), second case, we say Chon Kwan Chuk Jin(寸口尺診) reducingly. Chon Gu(寸口) is the area which is the radial artery of wrist joint. What we attemp diagnose by only Chon Gu Mac(寸口脈), it is clearly shoued in the method of Nan Kyoung, five Nan(難經五難). 2) Because Jin Mac(診脈) is made in only Chon Gu(寸口), that is the area in which is concentated Kyoung Kee(經氣). That is the birth of Jin Kee(眞氣) and Jin Kee(眞氣) is related with disease. We can diagnose disease by taking Chon Gu(寸口). 3) Chuk Jin(尺診) in Nae Kyoung(難經) have two things. One is Il Chuk(一尺), the other is Chon Kwan Chu(寸關尺). 4) Chuk Chon Jin(尺寸診) is the method which diagnose the difference of point and the condition of Mac(脈) by dividing a part of Chuk(尺) in the area of Chon Gu(寸口). In Chon Gu Jin(寸口診), by introducing the theory of Yin Yang(陰陽), the method of Chon Gu Jin(寸口診) is developed by chon Gu Jin(寸口診). 5) What Chuk Kwan Chon Jin(寸關尺診) is that area of the Chon Gu(寸口) are divided fot three point, we can diagnose. By consulting Sam Bu Gu Who Jin(三部九候診), developping of the method of acupunture, utilzing the theory of five element(五行) it is devised by concentrating way of thinking of the method mac Jin(脈診) exiting. 6) Chon Kwan Chuk Jin MaC(寸關尺診脈) begin from Nae Kyoung(內徑) exiting. After Nan Kyoung(內徑), spread out widely from Mac Kyoung(脈診) of Wang Suk wha(王叔和), the future medicins followed it. Yang Hyun Jo(楊玄操) and established Chon Kwan Chuk Jin(寸關尺診) which is used widely today. This right and left Chon Kwan Chuk Jin(寸關尺診), we call it method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 7) We can think the base which presume the arrangement of the viscera for Chon Kwan Chuk(寸關尺) of the right and the left. 8) The origin, which seperate the right and the left of Mac(脈), is showed at the treory of Ji Jin Yo Dae(至眞要大論) in So Mun(素問) which Chon Chuk(寸尺) seperate the right and the left. But the method of diagnosis in Nan Kyoung(難經) have no seperation the fight and the left. Otherwise this. there is clearly writtened the seperation for the right origin of the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈) seek for Cang Gong(倉公). 9) Yang Hyun Jo(楊玄操) notice that the Chuk(尺) is mentioned for Sam Cho(三焦) in the method of Mac Kyuong(脈經), Sim Po Kyung(心包經) which put together with Sam Cho(三焦) allot on this, he had established the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 10) On the method of Paen Jak Yin Yang Mac(扁鵲陰陽脈) in Mac Kyoung(脈經), equal article exist with the theory of Pyung In Kee Sang(平人氣象論) in So Mun(素問). When Wang Suk Wha(王叔和) write Mac Kyung(脈經), we can presume that the book of Mac(脈) which Paen Jak(扁鵲) had experienced the origin have exited besides So Mun(素問), Young Chu(靈樞). If so he must be make Chon Kwan Chuk Jin(寸關尺診) very fairly standard. So Nae Kyoung(內經), which must be fllowed the method of Paen Jak Mac(扁鵲脈), do the method diagnosis of Chon Kwan Chuk(寸關尺), diagnise of disease and treat.

  • PDF