The Evaluation of Reliability and Validity for Mibyeong Questionnaire (증상 정도, 기간, 불편정도 및 회복력 기반 미병 설문지의 신뢰도 및 구성 타당도 평가)

  • Jang, Eunsu;Yoon, Ji-Hyeon;Lee, Youngseop
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.21 no.1
    • /
    • pp.13-25
    • /
    • 2017
  • Objectives The purpose of this study was to evaluate the reliability and the validity of Mibyeong Questionnaire (MQ). The subjects enrolled in this study was 165 from July 2015 to Jan. 2016. The surveys were conducted twice with 3 month terms. Methods The Cronbach's ${\alpha}$ analysis for internal reliability, Pearson Correlation Coefficient analysis for test-retest reliability, Factor analysis with varimax rotation for construct validity, Kappa analysis for diagnostic reliability were used. The significant p-value was less than 0.05. Results and Conclusions The result showed that the Cronbach's ${\alpha}$ of MQ was .857-.937 and total was .913. The reliabilities between test and retest for the MQ were .666-.832 (0.416-0.673, in case of including recovery question) in intraclass correlation coefficient (ICC). The Kappa of recovery question in each item was ranged 0.23(80.6% in agreement rate) to .46(87.9% in agreement rate). In test-retest the Kappa value of Mibyeong diagnosis referred by median value was .418(71% in agreement rate). This study revealed that MQ is a reliable and valid questionnaire.

Development Cut-off Value for Yin-deficiency Questionnaire and Diagnostic Ability of Yin-deficiency in Xerostomia (구강건조증 환자에서 음허 측정 설문지 절단점 개발 및 진단능 평가)

  • Jang, Seung-Won;Kim, Jin-Sung
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.483-497
    • /
    • 2014
  • Objectives: The aims of study were developing cut-off value of Yin-deficiency questionnaire (YDQ) for diagnosis of Yin-deficiency (YD) and compare diagnostic ability between YDQ and Yin-deficiency scale score (YDS) in xerostomia patients. Methods: We recruited 58 xerostomia patients. They were diagnosed YD or non-YD by 3 Korean medicine doctors (KMD). We assessed YD using YDQ and YDS. We evaluated xerostomia using VAS, Dry Mouth Symptom Questionnaire (DMSQ), Salivary Flow Rate (SFR), oral moisture on buccal mucosa and tongue surface (OMB and OMT). We surveyed tongue coatings using Winkel Tongue Coating Index (WTCI). Results: We diagnosed 23 patients YD and 35 patients non-YD. There were no significant differences of age, sex and body mass index between the YD and non-YD groups. Using receiver operating characteristic curve analysis, the optimal cut-off value of YDQ was defined as 304. Sensitivity, specificity and Youden index of YDQ were 86.96%, 71.43% and 1.5839 respectively. Using Cohen's coefficient of agreement, we found that degree of agreement between KMD and YDQ diagnosis was moderate (${\kappa}$=0.524, p<0.001). Using Pearson's correlation analysis, we found concurrent validity of YDQ and YDS were significant correlated. Using area under curve value, we found diagnostic ability between YDQ and YDS were not significantly different (p=0.505), but there were more strong correlations between DMSQ-symptoms and YDQ (r=0.731, p<0.001) than correlations between DMSQ-symptoms and YDS (r=0.418, p<0.01). Conclusions: The cut-off value of YDQ can diagnose YD in xerostomia and diagnostic ability of YDQ in xerostomia is better than YDS.

Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

  • Campello, Andrea Fagundes;Goncalves, Lucio Souza;Guedes, Fabio Ribeiro;Marques, Fabio Vidal
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • Purpose: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chisquare test. Results: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions(P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

Unsteady Flow Rate Measurement Based on Distributed Parameter Pipeline Model (분포정수계 관로모델을 이용한 비정상 유량계측)

  • Kim, Do-Tae;Hong, Sung-Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.8-13
    • /
    • 2008
  • The paper proposes a model-based measurement of unsteady flow rate by using distributed parameter pipeline model and the measured pressure values at two distant points along the pipeline. The distributed parameter model of hydraulic pipeline is applied with consideration of frequency dependent viscosity friction and unsteady velocity distribution at a cross section of a pipeline. By using the self-diagnostics functions of the measurement method, the validity is investigated by comparison with the measured and estimated pressure and flow rate wave forms at the halfway section on the pipeline. The results show good agreement between the estimated flow rate wave forms and theoretical those under unsteady laminar flow conditions. The method proposed here is useful in estimating unsteady flow rate through an arbitrary cross section in hydraulic pipeline and components without installing an instantaneous flowmeter.

Optimum Image Compression Rate Maintaining Diagnostic Image Quality of Digital Intraoral Radiographs

  • Song Ju-Seop;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.265-274
    • /
    • 2000
  • Purpose: The aims of the present study are to determine the optimum compression rate in terms of file size reduction and diagnostic quality of the images after compression and evaluate the transmission speed of original or each compressed image. Materials and Methods: The material consisted of 24 extracted human premolars and molars. The occlusal surfaces and proximal surfaces of the teeth had a clinical disease spectrum that ranged from sound to varying degrees of fissure discoloration and cavitation. The images from Digora system were exported in TIFF and the images from conventional intraoral film were scanned and digitalized in TIFF by Nikon SF-200 scanner (Nikon, Japan). And six compression factors were chosen and applied on the basis of the results from a pilot study. The total number of images to be assessed were 336. Three radiologists assessed the occlusal and proximal surfaces of the teeth with 5-rank scale. Finally diagnosed as either sound or carious lesion by one expert oral pathologist. And sensitivity, specificity and k value for diagnostic agreement was calculated. Also the area (Az) values under the ROC curve were calculated and paired t-test and oneway ANOVA test was performed. Thereafter, transmission time of the image files of the each compression level was compared with that of the original image files. Results: No significant difference was found between original and the corresponding images up to 7% (1 : 14) compression ratio for both the occlusal and proximal caries (p<0.05). JPEG3 (1 : 14) image files are transmitted fast more than 10 times, maintained diagnostic information in image, compared with original image files. Conclusion: 1 : 14 compressed image file may be used instead of the original image and reduce storage needs and transmission time.

  • PDF

Comparison of Cellular Features Diagnostic of Papillary Thyroid Carcinoma in Liquid-Based (Cell Scan 1500TM) Preparations and Conventional Smears

  • Lee, Jung Dal;Park, Yong Wook;Back, OunCheol;Jung, Pa Jong;Kim, Jong Yull
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.3
    • /
    • pp.108-113
    • /
    • 2013
  • The study compared the cytological features of papillary thyroid carcinoma (PTC) in liquid-based preparations (LBPs) and conventional Pap (CP) smears from fine needle aspiration (FNA), and assessed the feasibility of LBP using the Cell Scan $1500^{TM}$ processor on thyroid FNA samples. Thyroid FNA samples were obtained from 883 consecutive patients. Each sample was divided into two and used for LBPs and CP smears. All were screened independently in a double-blind manner. From the 883 cases, 95 cases were diagnosed as PTC in one or both types of preparation (10.8%). PTC was diagnosed via CP smears in 83 cases (87.4%) and via LBPs in 70 cases (73.7%). However, there were differences in categorization between the paired preparations: Twelve (12) PTCs were misinterpreted in CP smears and 25 PTCs in LBPs. There was a significant discrepancy in the rate of detection of the diagnostic features, with LBPs having a lower detection rate. One (1) case (1.2%) of CP smears and 16 cases (22.9%) of LBPs were categorized as unsatisfactory/nondiagnostic in a total of the 95 PTCs. To conclude, the detection rate of the diagnostic features of PTC is lower in Cell Scan 1500TM samples than in CP smears. However, there are some cases in which a diagnosis of PTC is made in LBPs, but not in CP smears. Therefore, definitive cancer diagnosis in thyroid FNA preparations is likely to result from agreement between direct smears and Cell Scan 1500TM preparations.

  • PDF

A Study on the agreement of Principal Diagnosis (주상병 일치도에 관한 연구 -1개 중소병원을 중심으로-)

  • Seo, Young-Suk;Kim, Yoo-Mi;Nam, Moon-Hee;Kang, Sung-Hong;Lim, Ji-Hye
    • Quality Improvement in Health Care
    • /
    • v.15 no.1
    • /
    • pp.123-133
    • /
    • 2009
  • Background : The principal diagnosis has been used in many different fields such as hospital statistics, medical research, insurance claim, national health statistics and so on. Some principal diagnoses have a relatively low level of reliability in the medium-sized hospitals. The purpose of this study is to identify the reliability level of principal diagnoses and to suggest ways to improve reliability of the principal diagnosis. Method : Data were collected from a medium-sized hospital located in Pusan. The discharge summaries on 323 patients who were discharged in January, 2008 and the outpatient summaries on 251 patients who visited the hospital on March 28, 2008 were collected, and descriptive analysis was performed using SPSS version 12.0K. Result : The findings are the followings: (1) the diagnostic consistency rate between medical records and doctors' was 92.0%; (2) the diagnostic consistency rate between medical records and insurance claims was 86.1%; (3) the diagnostic consistency rate between doctors' diagnoses and insurance claims was 80.2%. The evidence seems to indicate that some principal diagnoses have reliability problems in the medium-sized hospitals. Conclusion : The results of this study suggest the followings: (1) employees should be trained and supervision of hospital activities are needed; (2) network systems should be constructed for each department; (3) professions need to be fostered (4) doctors' awareness of medical records should be changed.

  • PDF

The Study on Quantum Efficiency of $CaWO_4$ Screen with Diagnostic X-ray (진단 X선에 대한 $CaWO_4$ 증감지의 양자효율 연구)

  • Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.379-382
    • /
    • 2002
  • Lately, intensifying screen of the $CaWO_4$ is used to medical treatment and diagnosis of the image. In this paper, we investigated transmission fraction and mass attenuation coefficient of $CaWO_4$ screen about diagnostic x-ray of low energy using MCNP 4C code. Experimentally, for 0.9 mm-$CaWO_4$ screen, the absorbable rate of diagnostic x-ray is more than 95%. according to kVp, the experimental value of mass attenuation coefficient is in a1most agreement with an corrected estimate value of MCNP and the deviation of experimental values is less than ${\pm}7%$. Using the MCNP code through this paper, we can make an estimate of signal and design for construction of the CaWO4/a-Se based digital x-ray image detector and make a good use of the foundation data for development of other materials.

  • PDF

A Study of Changes in Body Shape, Temperament, Symptoms and Sasang Constitutional Values Using the Korea Sasang Constitutional Diagnostic Questionnaire (KS-15) : 5 Year Follow Up (사상체질 진단설문지(KS-15)를 이용한 외형, 성정, 병증의 추적관찰 및 체질값 변화 연구 : 5년 추적)

  • Kyoungsik Jeong;Bok-Nam Seo;Yunyoung Kim;Eunsu Jang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.36 no.2
    • /
    • pp.1-11
    • /
    • 2024
  • Objectives The purpose of this study was to compare between baseline and follow up data after 5 years about the change of Sasang constitutional value. Methods Cohort data of educational personnel in D University was used. Korean Sasang Constitutional Diagnostic Questionnaire was used to compare Sasang value including body shape, temperament, and pathological symptoms in baseline with those of follow up. Paired t test, chi-square test, correlation analysis and cohen's kappa coefficient was used. Results Total 150 subjects participated in this analysis. Taeeumin, Soeumin and Soyangin was 71, 46 and 33 respectively. Height decreased in follow-up, and weight increased, accordingly body mass index increased(p<.05). The score of nocturia was significantly increased, and the temperature of drinking water was significantly decreased. The consistency rate of the Sasang constitutional values in KS-15 between baseline and follow up was 76%, and the kappa value was 0.607. Compared to the expert's diagnosis, the agreement rate was 66.7% in baseline and 69.3% in follow up. Conclusion As times goes by, Sasang Constitutional phenotype, such as body mass index, nocturia, and temperature of drinking water, and accordingly, the predicted value of Sasang constitution may be changed. Those who use Sasang constitutional type and therapy in clinics should consider these factors.

Source Image Based New 3D Rotational Angiography for Differential Diagnosis between the Infundibulum and an Internal Carotid Artery Aneurysm : Pilot Study

  • Jang, Hyeongyu;Jung, Woo Sang;Myoung, Seong Uk;Kim, Jung-Jae;Jang, Chang Ki;Cho, Kwang-Chun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.726-731
    • /
    • 2021
  • Objective : Distinguishing between an infundibulum and a true aneurysm is clinically important. This study aimed to evaluate whether using source image based new three-dimensional rotational angiography (S-n3DRA) can increase the rate of aneurysm detection and improve distinction between a true aneurysm and an infundibulum. Methods : Twenty-two consecutive patients with 23 lesions, were evaluated by time-of-flight (TOF) magnetic resonance angiography (MRA), S-n3DRA, and digital subtraction angiography (DSA). The data were retrospectively and independently reviewed by two neurointerventionists, and the diagnoses based on TOF MRA, S-n3DRA, and DSA were compared. The diagnostic efficacy (interobserver agreement and diagnostic performance) of S-n3DRA was compared with that of TOF MRA. Results : S-n3DRA showed higher interobserver agreement (κ=0.923) than TOF MRA (κ=0.465) and significantly higher accuracy than MRA in distinguishing an aneurysm from an infundibulum (p=0.0039). Conclusion : Compared to MRA, S-n3DRA could provide better screening accuracy and information for distinguishing an aneurysm from an infundibulum. Therefore, S-n3DRA has the potential to reduce the need for DSA.