• Title/Summary/Keyword: Diagnostic Tool

Search Result 987, Processing Time 0.032 seconds

The FMD Diagnostic Kit as a Boundary Object and Boundary Making: Conflicts and Negotiations Between the State-centered and Decentralized Sociotechnical Orders (경계물과 경계만들기로서 구제역 간이진단키트: 국가기술중심주의와 분권주의의 충돌)

  • Kim, Kiheung
    • Journal of Science and Technology Studies
    • /
    • v.18 no.2
    • /
    • pp.307-342
    • /
    • 2018
  • This article is to discuss about a debate on controlling and handling rights of diagnostic instruments for the outbreak of Foot-and-Mouth Disease(FMD) in South Korea between 2010 and 2011. The epidemic of FMD caused catastrophic shockwave to the whole Korean society and there was fierce debate what was the best diagnostic tool for the disease and who owned the controlling power. The central government insisted to have the power of controlling the diagnostic tool to maintain the nation-centered disease control while local governments and civil organisations attempted to take over the controlling power of the diagnostic tools. In this article the concept of boundary objects which was suggested by an American STS academic, Susan Leigh Star and her colleagues. The boundary object could be the useful concept for capturing the whole process of constructing and imposing meanings and social orders in the diagnostic tool, called the portable antibody/antigen diagnostic kit. The constructing process of this boundary object must be understood with relation to boundary making activities between different social groups.

Performance Evaluation of Biozentech Malaria Scanner in Plasmodium knowlesi and P. falciparum as a New Diagnostic Tool

  • Firdaus, Egy Rahman;Park, Ji-Hoon;Muh, Fauzi;Lee, Seong-Kyun;Han, Jin-Hee;Lim, Chae-Seung;Na, Sung-Hun;Park, Won Sun;Park, Jeong-Hyun;Han, Eun-Taek
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.2
    • /
    • pp.113-119
    • /
    • 2021
  • The computer vision diagnostic approach currently generates several malaria diagnostic tools. It enhances the accessible and straightforward diagnostics that necessary for clinics and health centers in malaria-endemic areas. A new computer malaria diagnostics tool called the malaria scanner was used to investigate living malaria parasites with easy sample preparation, fast and user-friendly. The cultured Plasmodium parasites were used to confirm the sensitivity of this technique then compared to fluorescence-activated cell sorting (FACS) analysis and light microscopic examination. The measured percentage of parasitemia by the malaria scanner revealed higher precision than microscopy and was similar to FACS. The coefficients of variation of this technique were 1.2-6.7% for Plasmodium knowlesi and 0.3-4.8% for P. falciparum. It allowed determining parasitemia levels of 0.1% or higher, with coefficient of variation smaller than 10%. In terms of the precision range of parasitemia, both high and low ranges showed similar precision results. Pearson's correlation test was used to evaluate the correlation data coming from all methods. A strong correlation of measured parasitemia (r2=0.99, P<0.05) was observed between each method. The parasitemia analysis using this new diagnostic tool needs technical improvement, particularly in the differentiation of malaria species.

Clinical Application of $^{18}F-FDG$ PET in Neuroblastoma (신경모세포종에서 $^{18}F-FDG$ PET의 임상 이용)

  • Paeng, Jin-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.134-136
    • /
    • 2008
  • Neuroblastoma is the most common extracranial solid tumor in children. In diagnostic assessment of neuroblastoma, $^{18}F-FDG$ PET has been reported to have high diagnostic performance, especially, very high sensitivity in staging, restaging, and assessment of therapeutic efficacy. In comparison with conventional diagnostic imaging modalities including a, bone scan, and MIBG scan, $^{18}F-FDG$ PET showed better diagnostic performance. According to clinical research data hitherto, $^{18}F-FDG$ PET is expected to be an effective diagnostic tool in the management of neuroblastoma.

Diagnostic Pitfalls in Breast Fine Needle Aspiration Cytology: False Positive and False Negative (유방 세침흡인 세포검사의 진단적 함정: 위양성과 위음성)

  • Park, Kyeong-Mee
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.112-118
    • /
    • 2007
  • Fine needle aspiration cytology (FNAC) has become a highly preferred, minimally invasive diagnostic tool of choice in the diagnosis of a palpable breast mass owing to its sensitivity, specificity, cost-effectiveness, and expediency. Although breast needle biopsies have been widely employed recently due to the increased detection rate of non-palpable early lesions, the importance of the use of FNAC cannot be underestimated. It comprises part of the diagnostic triad for the breast along with a physical examination and mammography, which together contribute to an increasing diagnostic accuracy. The differential diagnosis of a benign and malignant lesion is of the utmost importance in the diagnosis of breast lesions, and therefore the understanding of the possible diagnostic pitfalls is of great importance.

Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes (X선관의 실효초점 측정에 관한 고찰)

  • Chang, Kwang-Hyun;Lim, Oh-Soo;Kim, Hyung-Kee;Song, Chang-Wook;Cheung, Kyung-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

Application of Receiver Operating Characteristic (ROC) Curve for Evaluation of Diagnostic Test Performance (진단검사의 특성 평가를 위한 Receiver Operating Characteristic (ROC) 곡선의 활용)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.33 no.2
    • /
    • pp.97-101
    • /
    • 2016
  • In the field of clinical medicine, diagnostic accuracy studies refer to the degree of agreement between the index test and the reference standard for the discriminatory ability to identify a target disorder of interest in a patient. The receiver operating characteristic (ROC) curve offers a graphical display the trade-off between sensitivity and specificity at each cutoff for a diagnostic test and is useful in assigning the best cutoff for clinical use. In this end, the ROC curve analysis is a useful tool for estimating and comparing the accuracy of competing diagnostic tests. This paper reviews briefly the measures of diagnostic accuracy such as sensitivity, specificity, and area under the ROC curve (AUC) that is a summary measure for diagnostic accuracy across the spectrum of test results. In addition, the methods of creating an ROC curve in single diagnostic test with five-category discrete scale for disease classification from healthy individuals, meaningful interpretation of the AUC, and the applications of ROC methodology in clinical medicine to determine the optimal cutoff values have been discussed using a hypothetical example as an illustration.

Reliability estimation about quality assurance method of radiotherapy planning (방사선치료계획 정도관리 방법에 따른 신뢰도 평가)

  • Kim, Jeong-Ho;Kim, Gha-Jung;Yoo, Se-Jong;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.119-124
    • /
    • 2015
  • According as radiation therapy technique develops, standardization of radiation therapy has been complicated by the plan QA(Quality Assurance). However, plan QA tools are two type, OADT (opposite accumulation dose tool) and 3DADT (3 dimensional accumulation dose tool). OADT is not applied to evaluation of beam path. Therefore tolerance error of beam path will establish measurement value at OADT. Plan is six beam path, five irradiation field at each beam path. And beam path error is 0 degree, 0.2 degree, 0.4 degree, 0.6 degree, 0.6 degree, 0.8 degree. Plan QA accomplishes at OADT, 3DADT. The more path error increases, the more plan QA error increases. Tolerance error of OADT path is 0.357 using tolerance error of conventional plan QA. Henceforth plan QA using OADT will include beam path error. In addition, It will increase reliability through precise and various plan technique.

CNC-implemented Fault Diagnosis and Web-based Remote Services

  • Kim Dong Hoon;Kim Sun Ho;Koh Kwang Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1095-1106
    • /
    • 2005
  • Recently, the conventional controller of machine-tool has been increasingly replaced by the PC-based open architecture controller, which is independent of the CNC vendor and on which it is possible to implement user-defined application programs. This paper proposes CNC­implemented fault diagnosis and web-based remote services for machine-tool with open architecture CNC. The faults of CNC machine-tool are defined as the operational faults occupied by over $70{\%}$ of all faults. The operational faults are unpredictable as they occur without any warning. Two diagnostic models, the switching function and the step switching function, were proposed in order to diagnose faults efficiently. The faults were automatically diagnosed through the fault diagnosis system using the two diagnostic models. A suitable interface environment between CNC and developed application modules was constructed for the internal function of CNC. In addition, a suitable web environment was constructed for remote services. The web service functions, such as remote monitoring and remote control, were implemented, and their operability was tested through the web. The results obtained through this research could be a model of fault diagnosis and remote servicing for machine-tool with open architecture CNC.