• Title/Summary/Keyword: Diagnostic Techniques

Search Result 648, Processing Time 0.028 seconds

A Study on the Fetal Umbilical Artery Doppler Blood Flow Velocity Waveforms in Normal Pregnancy (정상 임신에서 Doppler 초음파를 이용한 제대동맥 혈류속도 파형에 관한 연구)

  • Bae, Cheol-Seong;Kwun, Gee-Jin;Lee, Doo-Jin;Park, Yoon-Kee;Lee, Sung-Ho;Cho, Kil-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.63-71
    • /
    • 1991
  • Noninvasive techniques for antenatal detection of the fetal development and well-being such as biophysical profile, non-stress and stress test remain major challenges in modem obstetric practice. To obtain and analyze umbilical artery velocity waveform by pulsed-wave doppler ultrasound, a total of 160 determinations were carried out on 157 normal pregnant women between 16th to 41st week gestation. The ratio of peak systolic to end-diastolic flow velocity(S/D ratio), pulsatility index and resistance index were measured as indices of the resistance in feto-placental circulation. The results were as follows : As gestation advances, the, mean values for peak systolic and end-diastolic velocities raised progressively. As gestation advances, the mean values for the S/D ratio declined progressively, exhibiting high diastolic flow velocity caused by low resistance. Pulsatility index, and resistance index were also declined progressively, as gestation advances. The analysis of umbilical artery blood flow velocity waveforms provides a new noninvasive technique to evaluate fetal development and well-being, and may be expected a reliable method for assessment of fetal life.

  • PDF

A PILOT STUDY FOR STANDARDIZATION OF BERKELEY PUPPET INTERVIEW - SYMPTOMATOLOGY & PARENT-CHILD RELATIONSHIP SCALE (Berkeley Puppet Interview의 표준화를 위한 예비 연구 - 증상 척도와 부모-자녀 관계척도)

  • Shin, Min-Sup;Son, Jung-Woo;Cho, Soo-Churl;Kim, Boong-Nyun;Kim, Soo-Kyoung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.103-111
    • /
    • 2003
  • Objectives:BPI was developed for assessing young children's perceptions. Using an interactive techniques for interviewing children, the BPI blends structured and clinical interviewing technique. Present study was to evaluate the reliability, validity and the clinical utility of Berkeley Puppet Interview(BPI) for young children aged 4 to 7. Methods:Subjects consisted of 37 children(boy20, girl 17) between the age of 4 and 7 who visited the child-psychiatry outpatient division of children's hospital in Seoul and Chungju. The measures used in this study BPI-S(symptomatology) and BPI-PC(parent-child relationship). BPI was translated into Korean by three clinical psychologists. To examine the reliability, Chonbach's alpha were calculated and to examine the validity, correlation coefficients were calculated on BPI-S & K-CBCL. Results:BPI-PC's Cronbach's alpha was 0.86 and BPI-S's Cronbach's alpha was 0.74. Correlation between the internalizing scale of BPI-S and that of K-CBCL was 0.477 and correlation between the internalizing scale of BPI-S and the externalizing scale of K-CBCL was -0.431, suggesting the validity of BPI-S. Conclusion:These results show that BPI-S & BPI-PC may be useful tool for young children's diagnostic interview.

  • PDF

Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study

  • Lee, Jungwon;Pyo, Se-Wook;Cho, Hyun-Jae;An, Jung-Sub;Lee, Jae-Hyun;Koo, Ki-Tae;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.1
    • /
    • pp.56-66
    • /
    • 2020
  • Purpose: A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods: Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. Results: The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Conclusions: Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.

Chromosome Analysis in Clinical Samples by Chromosome Diagnostic System Using Fluorescence in Situ Hybridization (국산 Fluorescence in Situ Hybridization 시스템을 이용한 다양한 검체에서의 염색체 분석)

  • Moon, Shin-Yong;Pang, Myung-Geol;Oh, Sun-Kyung;Ryu, Buom-Yong;Hwang, Do-Yeong;Jung, Byeong-Jun;Choe, Jin;Sohn, Cherl;Chang, Jun-Keun;Kim, Jong-Won;Kim, Seok-Hyun;Choi, Young-Min
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.3
    • /
    • pp.335-340
    • /
    • 1997
  • Fluorescence in situ hybridization (FISH) techniques allow the enumeration of chromosome abnormalities and from a great potential for many clinical applications. In order to produce quantitative and reproducible results, expensive tools such as a cooled CCD camera and a computer software are required. We have developed a Chromosome Image Processing System (Chips) using FISH that allows the detection and mapping of the genetic aberrations. The aim of our study, therefore, is to evaluate the capabilities of our original system using a black-and-white video camera. As a model system, three repetitive DNA probes (D18Z1, DXZ1, and DYZ3) were hybridized to variety different clinical samples such as human metaphase spreads and interphase nuclei obtained from uncultured peripheral blood lymphocytes, uncultured amniocytes, and germ cells. The visualization of the FISH signals was performed using our system for image acquisition and pseudocoloring. FISH images were obtained by combining images from each of probes and DAPI counterstain captured separately. Using our original system, the aberrations of single or multiple chromosomes in a single hybridization experiment using chromosomes and interphase nuclei from a variety of cell types, including lymphocytes, amniocytes, sperm, and biopsied blastomeres, were enabled to evaluate. There were no differences in the image quality in accordance with FISH method, fluorochrome types, or different clinical samples. Always bright signals were detected using our system. Our system also yielded constant results. Our Chips would permit a level of performance of FISH analysis on metaphase chromosomes and interphase nuclei with unparalleled capabilities. Thus, it would be useful for clinical purposes.

  • PDF

A Multicenter Survey on the Current Status of Pediatric Blood Cultures in Korea (소아 대상 혈액배양검사 현황 파악을 위한 국내 다기관 설문조사)

  • Lee, Young Joon;Lee, Ji Young;Kong, Seom Kim;Yeon, Gyu Min;Hong, Yoo Rha;Oh, Chi Eun
    • Pediatric Infection and Vaccine
    • /
    • v.25 no.1
    • /
    • pp.17-25
    • /
    • 2018
  • Purpose: Blood culture is an essential diagnostic tool and requires clear indications, proper techniques, and quality control. We aimed to investigate whether blood cultures in children are appropriate for indications, are performed correctly, and receive proper quality control. Methods: We conducted an online survey targeting pediatric infectious diseases (ID) specialists working in general hospitals and neonatologists (Neo) working at hospitals operating a neonatal intensive care unit in Korea. Results: Approximately 81.1% (30/37) of pediatric ID specialists and 72.2% (52/72) of Neo responded to the survey. Some of the respondents (33.3% of ID and 59.6% of Neo) performed blood culture as a regular test irrespective of the indication. Approximately 40% of ID and 65.4% of Neo ordered only one set of blood culture in patients suspected with bacteremia. The most commonly used disinfectant for skin preparation was povidone-iodine, while the skin preparation method varied by institution. Approximately two-thirds of the institutions were monitoring the blood culture contamination rate, whereas relatively few provided staff with feedback on that rate. In addition, less than half of the institutions were providing regular staff training on blood culture (40% of ID and 28.8% of Neo). Conclusions: The indication and methods of blood culture for children varied according to institution, and few hospitals exert effort in improving the quality of blood culture. Institutions have to strive constantly toward improvement of blood culture quality and evidence-based recommendations for pediatric blood cultures should be standardized.

Diagnostic Significance of the Blood Disappearance Rate of $^{131}I$-Rose Bengal and of $^{198}Au$ colloid in Hepatobiliary Diseases (간담도질환(肝膽道疾患)에 있어서 $^{131}I$-Rose Bengal 및 $^{198}Au$ 교질(膠質)의 혈중소실율(血中消失率)의 진단적(診斷的) 의의(意義)에 관(關)한 연구(硏究))

  • Chun, Young-Kyoon;Koh, Chang-Soon;Hahn, Shim-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.5 no.2
    • /
    • pp.7-18
    • /
    • 1971
  • The liver function test was performed by means of two radioisotope tracer techniques in 20 normal subjects and in 63 patients with hepatobiliary diseases. The blood disappearance rates of $^{131}I$-rose bengal and of $^{198}Au$ colloid were determined by external counting method. The hepatocellular function and the hepatic blood flow were estimated from the observed data and the results were compared with those of the conventional liver function tests. The results obtained were as follows: 1. The mean blood disappearance half time of $^{131}I$-rose bengal was $6.6{\pm}0.63$ minutes in normal control, $17.7{\pm}6.93$ in cirrhosis of the liver, $16.6{\pm}4.80$ in acute hepatitis, and $14.7{\pm}3.46$ in obstructive jaundice. It was markedly prolonged in the hepatobiliary diseases as compared with the normal control, but there was no significant difference among the hepatobiliary diseases. 2. The mean blood disappearance half time of $^{198}Au$ colloid was $4.0{\pm}0.66$ minutes in normal control, $9.8{\pm}3.42$ in cirrhosis of the liver, $4.4{\pm}0.82$ in acute hepatitis, and $5.0{\pm}1.42$ in obstructive jaundice. The difference between cirrhosis of the liver and normal control Was statistically significant. However, there was no definite difference among acute hepatitis, obstructive jaundice, and normal control. The mean blood disappearance rate constant (K value) was $0.177{\pm}0.028/minute$ in normal control. In cirrhosis of the liver, it was markedly decreased which was suggestive of the reduced hepatic blood flow. 3. The ratio of $^{131}I$-rose bengal blood disappearance half time to $^{198}Au$ colloid disappearance half time was $1.68{\pm}0.20$ in normal control, $1.82{\pm}0.31$ in cirrhosis of the liver, $3.80{\pm}0.82$ in acute hepatitis, and $3.01{\pm}0.54$ in obstructive jaundice. The ratios in acute hepatitis and obstructive jaundice were remarkably higher than those in normal control and cirrhosis of the liver. 4. There was a significant correlation between the blood disappearance half time of $^{131}I$-rose bengal and that of $^{198}Au$ colloid in cirrhosis of the liver. 5. In cirrhosis of the liver, the blood disappearance half times of $^{131}I$-rose bengal and of $^{198}Au$ colloid were inversely correlated to the serum albumin level. In acute hepatitis, there was a good positive correlation between the blood disappearance half time of $^{131}I$-rose bengal and the serum transaminase activities. In obstructive jaundice, the blood disappearance half time of $^{131}I$-rose bengal was correlated to the serum bilirubin level.

  • PDF

A Biomechanical Modeling of Human Pharyngeal Muscular Dysfunction by Using FEM(Finite Element Method) (유한요소법을 이용한 인두의 기능이상에 대한 생체역학적 모델)

  • Kim Sung Jae;Bae Ha Suk;Choi Byeong Cheol;Kim Sung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.515-522
    • /
    • 2003
  • Pharynx is a system transporting foods by peristaltic motion(contraction and expansion movement! into the esophagus and functioning as airway passages. In this study, structural changes of pharyngeal dysfunction are analyzed by biomechanical model using CT and FEM(finite clement method). Loading condition was assumed that equal pressure was loaded sequentially to inside of pharyngeal tissue. In order to analyze the pharyngeal muscular dysfunction by biomechanical model. the pharyngeal dysfunctions was classified into 3 cases. Taking into account the clinical complication by neuromuscular symptoms such as pharyngeal dysfunction after stroke. we assumed that a change of material property is caused by muscular tissue stiffness. A deformation of cross sectional area of the pharynx is analyzed increasing the stiffness $25\%,\;50\%,\;75\%$ in each case on the basis of stress-strain relationship. Based on three-dimensional reconstruction of pharyngeal structure using limited factor - techniques and the optimization procedure by means of inverse dynamic approach. the biomechanical model of the human pharynx is implemented. The results may be used as clinical index illustrating the degree of pharyngeal muscular dysfunction. This study may be used as useful diagnostic model in discovering early deglutitory impediment caused by physiological or pathological pharyngeal dysfunction.

Studies on the Characteristics of Phosphorus in the Upland Soil I. Composition of Accumulated Phosphorus Forms and Available Phosphorus (경작지(耕作地) 전토양(田土壤)의 인산특성(燐酸特性)에 관(關)한 연구(硏究) I. 축적인산(蓄積燐酸)의 형태별(形態別) 조성(造成)과 유효인산(有效燐酸) 함량(含量)과의 관계(關係))

  • Shin, Cheol-Woo;Kim, Jeong-Je;Yoon, Jung-Hui
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 1988
  • A laboratory experiment was conducted to evaluate the phosphorus status and define the relationship between composition of phosphorus forms and available phosphorus with 149 phosphorus accumulated soil samples. Distribution percentage of inorganic, organic and available phosphorous to total phosphorus were 68.9 (Saloid-p 2.7, Al-p 26.4, Fe-p 27.6, Ca-p 12.2%), 6.7 and 26.0%, respectively. In the relationship between available phosphorus and inorganic phosphorus in soil, Al-p, Saloid-P, and Ca-P showed significant correlation with available phosphorus which did not showed significant one with Fe-p. Multiple liner regression equation between available and inoganic phosphorus abtained as follow, $Av.P=81.694+0.858Sa-p^{***}+0.648Al-p^{***}+0.091Ca-p^{**}(R=0.826^{***})$ and contribution rates of Saloid-p, Al-p, and Ca-p to available phosphorus were 26.1, 65.2, and 8.7%, respectively. Relationship between available and water soluble phosphorus, water soluble phosphorus and $0.01M-CaCl_2-p$ were highly significant, respectively, and soil solution P extracted with $0.01M-CaCl_2$ for 30 minutes was selected as one of usable diagnostic techniques for soil P status.

  • PDF

Current Trends in the Treatment of Syndesmotic Injury: Analysis of the Korean Foot and Ankle Society (KFAS) Member Survey (원위경비골인대 손상의 치료 동향: 대한족부족관절학회 회원 설문조사 분석)

  • Cho, Jaeho;Cho, Byung-Ki;Jeong, Bi O;Chung, Jin-Wha;Bae, Su-Young;The Academic Committee of Korean Foot and Ankle Society,
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • Purpose: This study was based on the Korean Foot and Ankle Society (KFAS) member survey and aimed to report the current trends in the management of syndesmotic injuries over the last few decades. Materials and Methods: A web-based questionnaire containing 36 questions was sent to all KFAS members in September 2021. The questions were mainly related to the preferred techniques and clinical experiences in the treatment of patients with syndesmotic injuries. Answers with a prevalence ≥50% of respondents were considered a tendency. Results: Seventy-six (13.8%) of the 550 members responded to the survey. The results showed that the most preferred method to diagnose a syndesmotic injury was magnetic resonance imaging (MRI). Intraoperatively, the external rotation stress test and the Cotton test were most frequently used to confirm syndesmotic diastasis. The reduction was usually done by a reduction clamp. One 3.5-mm screw was used most frequently over three cortices at 2~4 cm above the ankle joint. The preferred ankle position during fixation was 0° dorsiflexion. Removal of the syndesmotic screw was routinely done by most surgeons, mainly because of the limitation of movement and risk of screw breakage. Factors that affect suture button selection included non-rigid fixation which enables adequate fixation, early weight-bearing, and an infrequent need to remove the hardware. Inadequate reduction was considered the main factor that affects poor prognosis. Conclusion: This study proposes updated information about the current trends in the management of syndesmotic injuries in Korea. Consensuses in both the diagnostic and therapeutic approach to patients with syndesmotic injury were identified in this survey study. This study may raise the awareness of the various possible approaches toward the injury and should be used to further establish a standard protocol for the management of syndesmotic injuries.

Development of Cloud-Based Medical Image Labeling System and It's Quantitative Analysis of Sarcopenia (클라우드기반 의료영상 라벨링 시스템 개발 및 근감소증 정량 분석)

  • Lee, Chung-Sub;Lim, Dong-Wook;Kim, Ji-Eon;Noh, Si-Hyeong;Yu, Yeong-Ju;Kim, Tae-Hoon;Yoon, Kwon-Ha;Jeong, Chang-Won
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.7
    • /
    • pp.233-240
    • /
    • 2022
  • Most of the recent AI researches has focused on developing AI models. However, recently, artificial intelligence research has gradually changed from model-centric to data-centric, and the importance of learning data is getting a lot of attention based on this trend. However, it takes a lot of time and effort because the preparation of learning data takes up a significant part of the entire process, and the generation of labeling data also differs depending on the purpose of development. Therefore, it is need to develop a tool with various labeling functions to solve the existing unmetneeds. In this paper, we describe a labeling system for creating precise and fast labeling data of medical images. To implement this, a semi-automatic method using Back Projection, Grabcut techniques and an automatic method predicted through a machine learning model were implemented. We not only showed the advantage of running time for the generation of labeling data of the proposed system, but also showed superiority through comparative evaluation of accuracy. In addition, by analyzing the image data set of about 1,000 patients, meaningful diagnostic indexes were presented for men and women in the diagnosis of sarcopenia.