• 제목/요약/키워드: Diagnostic Technique of Structure

검색결과 46건 처리시간 0.027초

이중구조를 갖는 제어시스템의 구현과 신뢰도 분석에 관한 연구 (A Study on the Implementation of a Control System with Dual Structure and Its Reliability Analysis)

  • 박세화;문봉채;김병국
    • 대한전자공학회논문지
    • /
    • 제27권9호
    • /
    • pp.1351-1363
    • /
    • 1990
  • In this paper, a reliable control system structured with dual CPU modules and dual I/O modules is implemented as a means of achieving a highly reliable fault tolerant control system. For this, faults in the system modules are first examined, and a fault detection technique consisting of self diagnostic, comparison process, and exception processing is applied. Self diagnostic is used to locate which components in the modules have been failed, while comparison process is to cmpare control outputs computed by both CPU modules and protect the plant from malfunction by blocking failed control outputsin advance. Finally exception processing is used to determine the faults that are not detected immediately by the self diagnostic and comparison process, e.g. bus error processing when acknowledge signal for data transfer is not activeted in the I/O modules. Also reliability analysis is conducted for the discrete time Markov model with dual structure. It is shown quantitatively that the reliability is improved in the control system with dual structure in comparison with a system with single module structure.

  • PDF

외식기업 조직진단모형 개발에 관한 연구 - 델파이 기법으로 - (An Organizational Diagnostic Model for Food Service Firms Using the Delphi Technique)

  • 백유태;최세린;최규완
    • 한국식생활문화학회지
    • /
    • 제28권3호
    • /
    • pp.282-292
    • /
    • 2013
  • The purpose of this study is to identify a suitable organizational diagnostic model for analyzing the management efficiency of food service firms. We used the three-iteration Delphi technique on a panel of 19 business employees, 7 industry experts, and 4 employees in the food service industry. A total of 36 assessment indicators were developed through this panel, with numerous major findings. First, it is important to evaluate the leadership qualities of employees in terms of their motivation and competency. Second, it is important to evaluate the ability of employees to interface well with other employees. Third, it is important to evaluate and manage the brand image recognized by customers. Fourth, it is important to evaluate the fairness and regularity of the rewards given for an excellent job performance. Fifth, it is important to evaluate the level of communication and information distribution in the organizational culture. Last, but not least, it is important to evaluate the transparency and fairness of an organization in its human resource management (HRM) and the efficiency of its organizational structure. In conclusion, this study empirically shows how food service firms can develop an organizational diagnostic model to increase their managerial efficiency.

A hybrid structural health monitoring technique for detection of subtle structural damage

  • Krishansamy, Lakshmi;Arumulla, Rama Mohan Rao
    • Smart Structures and Systems
    • /
    • 제22권5호
    • /
    • pp.587-609
    • /
    • 2018
  • There is greater significance in identifying the incipient damages in structures at the time of their initiation as timely rectification of these minor incipient cracks can save huge maintenance cost. However, the change in the global dynamic characteristics of a structure due to these subtle damages are insignificant enough to detect using the majority of the current damage diagnostic techniques. Keeping this in view, we propose a hybrid damage diagnostic technique for detection of minor incipient damages in the structures. In the proposed automated hybrid algorithm, the raw dynamic signatures obtained from the structure are decomposed to uni-modal signals and the dynamic signature are reconstructed by identifying and combining only the uni-modal signals altered by the minor incipient damage. We use these reconstructed signals for damage diagnostics using ARMAX model. Numerical simulation studies are carried out to investigate and evaluate the proposed hybrid damage diagnostic algorithm and their capability in identifying minor/incipient damage with noisy measurements. Finally, experimental studies on a beam are also presented to compliment the numerical simulations in order to demonstrate the practical application of the proposed algorithm.

Development of a Diagnostic Technique of the Historic Structures Using a Thermal Infrared Camera

  • Nakabeppu, Jiro;Maeda, Atsushi;Gotoh, Keinosuke
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.493-495
    • /
    • 2003
  • The establishment of the investigation and the maintenance technique is required for preservation of old structures in Japan. This study attempts to diagnose the deterioration status of the historic structures using the thermal infrared camera. In some structures, the difference of the spatio-temporal change was observed in the surface temperature. For example, the cold joint of concrete was examined using this method effectively. As a result of this study, we have found useful guidelines in developing methodology to conduct diagnosis of historic buildings by using thermal infrared camera.

  • PDF

제어 시스템의 신뢰도 향상을 위한 이중화 구조 연구 (A study on the control system with dual structure to enhance its reliability)

  • 박세화;문봉채;김병국;변증남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.773-778
    • /
    • 1990
  • In this paper, a reliable control system structured with dual CPU modules and dual I/O modules is implemented as a means of achieving a highly reliable fault tolerant control system. For this, faults in the system modules are first examined, and a fault detection technique consisting of self diagnostic, comparison process, and exception processing is applied. Also reliability analysis is conducted for the discrete time Markov model with dual structure. It is shown quantitatively that the reliability is improved in the control system with dual structure in comparison with a system with single module structure.

  • PDF

Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

  • Park, Seung-Hee;Yun, Chung-Bang;Inman, Daniel J.
    • 비파괴검사학회지
    • /
    • 제27권3호
    • /
    • pp.217-223
    • /
    • 2007
  • This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure.

어드미턴스 기반 콘크리트 경화 모니터링의 실험 및 수치적 검증 (Experimental and Numerical Validation of the Technique for Concrete Cure Monitoring Using Piezoelectric Admittance Measurements)

  • 김완철;박규해
    • 비파괴검사학회지
    • /
    • 제36권3호
    • /
    • pp.217-224
    • /
    • 2016
  • 콘크리트는 건축물에 가장 많이 사용되는 재료 중 하나이다. 건축물 시공 시 적절한 하중 재하시점을 결정하기 위해 콘크리트의 경화 상태의 점검은 매우 중요한 사항이다. 또한 부정확한 경화 모니터링은 건축물의 부실공사 혹은 붕괴로 이어질 수 있다. 본 연구에서는 어드미턴스를 기반으로 한 압전체 센서 자가진단기법을 확장 적용한 콘크리트 경화 모니터링 기법을 개발하였다. 이 기법을 통해 콘크리트의 경화를 모니터링 하였으며 실험 결과 분석을 통해 본 기법의 상대강도 추정 가능성을 확인하였다. 또한 경화 시 발현강도에 따른 어드미턴스 신호 예측을 위해 수치적 모델링을 하였으며 실험 결과와 경화 진행 경향성을 비교하였다. 이를 통해 본 연구에서 개발한 기법의 효용성을 실험 및 수치적으로 확인하였다.

온도변화에 자유로운 임피던스 기반 국부 손상검색 (Temperature Effect-free Impedance-based Local Damage Detection)

  • 구기영;박승희;이종재;윤정방
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.21-26
    • /
    • 2007
  • This paper presents an impedance-based structural health monitoring (SHM) technique considering temperature effects. The temperature variation results in a significant impedance variation, particularly both horizontal and vertical shifts in the frequency domain, which may lead to erroneous diagnostic results of real structures. A new damage detection strategy has been proposed based on the correlation coefficient (CC) between the reference impedance data and a concurrent impedance data with an effective frequency shift which is defined as the shift causing the maximum correlation. The proposed technique was applied to a lab-sized steel truss bridge member under the temperature varying environment. From an experimental study, it has been demonstrated that a narrow cut inflicted artificially to the steel structure was successfully detected using the proposed SHM strategy.

  • PDF

다종 센서간 위상 차이를 이용한 충격 위치추정 기법 (Source localization technique for metallic impact source by using phase delay between different type sensors)

  • 최경식;최영철;박진호;김환우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.687-692
    • /
    • 2008
  • In a nuclear power plant, loose part monitoring and its diagnostic technique is one of the major issues for ensuring the structural integrity of the reactor system. Typically, accelerometers are mounted on the surface of a reactor vessel to localize impact location caused by the impact of metallic substances on the reactor system. However, in some cases, the number of the accelerometers is not enough to estimate the impact location precisely. In such a case, one of alternative plan is to utilize another type sensors that can measure the vibration of the reactor structure even though the measuring frequency ranges are different from each others. The AE sensors installed on the reactor structure can be utilized as additional sensors for loose part monitoring. In this paper, we proposed a new method to estimate impact location by using both accelerometer signal and AE signal, simultaneously. The feasibility of the proposed method is verified by an experiment. The experimental results demonstrate that we can enhance the reliability and precision of the loose part monitoring.

  • PDF

다종 센서간 위상 차이를 이용한 충격 위치추정 기법 (Source Localization Technique for Metallic Impact Source by Using Phase Delay between Different Type Sensors)

  • 최경식;최영철;박진호;김환우
    • 한국소음진동공학회논문집
    • /
    • 제18권11호
    • /
    • pp.1143-1149
    • /
    • 2008
  • In a nuclear power plant, loose part monitoring and its diagnostic technique is one of the major issues for ensuring the structural integrity of the reactor system. Typically, accelerometers are mounted on the surface of a reactor vessel to localize impact location cavsed by the impact of metallic substances on the reactor system. However, in some cases, the number of the accelerometers is not enough to estimate the impact location precisely. In such a case, one of alternative plan is to utilize another type sensors that can measure the vibration of the reactor structure even though the measuring frequency ranges are different from each others. The AE sensors installed on the reactor structure can be utilized as additional sensors for loose part monitoring. In this paper, we proposed a new method to estimate impact location by using both accelerometer signal and AE signal, simultaneously. The feasibility of the proposed method is verified by an experiment. The experimental results demonstrate that we can enhance the reliability and precision of the loose part monitoring.