• Title/Summary/Keyword: Diagnostic System

Search Result 2,374, Processing Time 0.033 seconds

Development of Power Cable Diagnostic and Insulation Measurement System (전력케이블 열화진단용 측정장치 개발)

  • Yi, Dong-Young;Kwon, Hyuk-Il;Chung, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2126-2129
    • /
    • 1999
  • We have developed the automatic diagnostic system for power cable insulation using DC voltage decay method in this work. Test condition, test method and diagnose criteria of our diagnostic system are adjustable to a class of power cables such as 3.3, 6.6, 11 and 22kV power cables. We have also developed measurement and diagnostic programs for win95 which is suitable for the management of database such as test condition, diagnose results and cable operation data.

  • PDF

Electric power characteristic test of diagnostic X-ray high voltage transformer by input power condition (고전압트랜스포머의 진공이 방사선출력 노이즈에 미치는 영향)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Young-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.499-499
    • /
    • 2008
  • High voltage transformer of Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. High voltage transformer of diagnostic X-ray system has been usefully used for diagnostic purpose but if high voltage transformer performances are deteriorated, low quality image will be archived. In this case, operator has to exposure to get a more good quality images. In this case, unexpected radiation could be exposed to patient and it is very harmful to the patient. And I would like to design and make equipment to checkable high voltage transformer performance after that I wish to test and study what it is most influences in radiation output quality.

  • PDF

A study on the design of fault diagnostic system based on PCA (PCA-기반 고장 진단 시스템 설계에 관한 연구)

  • Kim, Sung-Ho;Lee, Young-Sam;Han, Yoon-Jong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.5
    • /
    • pp.600-605
    • /
    • 2003
  • PCA(Principle Component Analysis) has emerged as a useful tool for process monitoring and fault diagnosis. The general approach requires the user to identify the root cause by interpreting the residual or principle components. This could be tedious and often impossible for a large process. In this paper, PCA scheme is combined with the FCM-based fault diagnostic algorithm to enhance the diagnostic results. The implementation of the FCM-based fault diagnostic system by using PCA is done and its application is illustrated on the two-tank system.

A Study on the Correlation between the Patterns of the Zone 2, 6 of Factor AA in 7-Zone-Diagnostic System and the Clinical Parameters (7구역진단기의 Factor AA 제2, 6구역 유형과 임상지표와의 상관성 연구)

  • Yu, Jung-Suk;Seol, Hyun;Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.25 no.2
    • /
    • pp.139-149
    • /
    • 2008
  • Objectives : The 7-zone-diagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of body. This study was to investigate the relation between the different patterns of Zone 2, 6 of Factor AA in VEGA DFM 722(VEGA, Germany), 7-zone-diagnostic system and clinical parameters. The purpose of this study was relation Korean traditional medicine and western medicine with the data from 7-zone-diagnostic system and the clinical parameters. Methods : This study was carried out with the data from some clinical parameters. We made two groups according to the Factor AA patterns of VEGA DFM 722. The Factor AA pattern of Group A is that the red bar graph of zone 2 was higher than the normal range and the red bar graph of zone 6 was lower than the normal range. The Factor AA pattern of Group B was that the red bar graph of zone 2 was lower than the normal range and the red bar graph of zone 6 was higher than the normal range. After the data from clinical parameters to correspond with conditions of each group were selected, the data from clinical parameters between each gropus analyzed statistically. Results and Conclusions : The values of Direct Bilirubin, GOT, BUN and BUN/Creatinine ratio of Group A were higher than them of Group B. The values of Sodium and Tyroxine of Group A were lower than them of Group B. These results mean that Group A has low energy but has increading tendency. To conclude, it is thought that the red bar graph of zone 2 is higher, the group is the more increasing and the red bar graph of zone 6 is lower, the group has the lower energy.

  • PDF

Self-Diagnostic Signal Monitoring System of KWP2000 Vehicle ECU using Bluetooth

  • Choi, Kwang-Hun;Lee, Hyun-Ho;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.132-137
    • /
    • 2004
  • On-Board Diagnostic(OBD) systems are in most cars and light trucks on the load today. During the 1970's and early 1980's manufacturers started using electronic means to control engine functions and diagnose engine problems. The CARB's diagnostic requirements to meet EPA emission standards have been designated as OBD with a goal of monitoring all of the emissions-related components, as well as the chassis, body, accessory devices and the diagnostic control network of the vehicle for proper operation. In this paper, we present a remote measurement system for the wireless monitoring of diagnosis signal and sensors output signals of ECU adopted KWP2000, united the OBD communication protocol, on OBD-compliant vehicle using the wirless communication technique of Bluetooth. In order to measure the ECU signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3C3410X is used for communicating ECU signals. The embedded system's software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on MicroC/OS kernel to communicate between bluetooth modules using bluetooth stack. The diagnostic system is developed using Visual C++ MFC and protocol stack of bluetooth for Windows environment. The self-diagnosis and sensor output signals of ECU is able to monitor using PC with bluetooth board connected in serial port of PC. The algorithms for measuring the ECU sensor output and self-diagnostic signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of self-diagnosis and sensor signals of ECU adopted KWP2000 in embedded system verified through the developed systems and algorithms.

  • PDF

A Study on the Correlation among the Patterns of the Zone 1, 2, 3 of Factor AA in 7-Zone-Diagnostic System and the Clinical Parameters (7구역진단기의 Factor AA 제1, 2, 3구역 유형과 임상지표와의 상관성 연구)

  • Cho, Yi-Hyun;Yu, Jung-Suk;Lee, Hwi-Yong;Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.25 no.6
    • /
    • pp.67-76
    • /
    • 2008
  • Objectives : The 7-zone-diagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of body. This study was to investigate the relation between the different patterns of Zone 1, 2, 3 of Factor AA in CP-6000A(VEGA, Germany), 7-zone-diagnostic system and clinical parameters. The purpose of this study was relation Korean traditional medicine and western medicine with the data from 7-zone-diagnostic system and the clinical parameters. Methods : This study was carried out with the data from some clinical parameters. We made three groups according to the Factor AA patterns of CP-6000A. The Factor AA pattern of Group A is that the red bar graph of zone 1, 2, 3 were higher than the normal range and the others were the normal range. The Factor AA pattern of Group B was that the red bar graph of zone 1, 2, 3 was the normal range and the others were the normal range. The Factor AA pattern of Group C was that the red bar graph of zone 1, 2, 3 was lower than the normal range and the others were the normal range. After the data from clinical parameters to correspond with conditions of each group were selected, the data from clinical parameters among each groups analyzed statistically. Results : The values of GOT, GPT, r-GPT, Triglyceride, BUN, Uric acid of group A was higher than group C. Gastroscope of group A and B was higher than group C. Conclusions : It is thought that the red bar graph of zone 1, 2, 3 is higher, the group has the higher energy and the energy has a character of fire(熱). Those patterns have a high risk of hyperlipermia and liver, stomach disease.

  • PDF

A Dual Selection Marker Transformation System Using Agrobacterium tumefaciens for the Industrial Aspergillus oryzae 3.042

  • Sun, Yunlong;Niu, Yali;He, Bin;Ma, Long;Li, Ganghua;Tran, Van-Tuan;Zeng, Bin;Hu, Zhihong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.2
    • /
    • pp.230-234
    • /
    • 2019
  • Currently, the genetic modification of Aspergillus oryzae is mainly dependent on protoplast-mediated transformation (PMT). In this study, we established a dual selection marker system in an industrial A. oryzae 3.042 strain by using Agrobacterium tumefaciens-mediated transformation (ATMT). We first constructed a uridine/uracil auxotrophic A. oryzae 3.042 strain and a pyrithiamine (PT)-resistance binary vector. Then, we established the ATMT system by using uridine/uracil auxotrophy and PT-resistance genes as selection markers. Finally, a dual selection marker ATMT system was developed. This study demonstrates a useful dual selection marker transformation system for genetic manipulations of A. oryzae 3.042.

Performance Test for Automatic Exposure Control by Zone System (Zone System을 이용한 자동노출장치의 성능 측정에 관한 실험)

  • Kang, Hee-Doo;Pyo, Chang-Gi;Cha, Jung-Hee;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.57-63
    • /
    • 1998
  • AEC was designed to assist in the production of radiographs of equal density and to aid in the production f consistently high quality radiographs. Many improvements have been made in the AEC and these have helped to increase it's acceptance. Newer system (Falling load) control kVp and mA as well as exposure time. Authors have had experiments about the characteristics of AEC by Zone System. Zone System is the method to detection of photographic image qualify by control the photo print from Fred Archer and Ansel Adams. With the Zone System theory the experiments of density control, characteristics of phantom thickness and reproducibility of occupation rate of contrast media could make quality control of X-ray photography effectively in falling load system.

  • PDF

Development of Neuro-Fuzzy-Based Fault Diagnostic System for Closed-Loop Control system (페푸프 제어 시스템을 위한 퍼지-신경망 기방 고장 진단 시스템의 개발)

  • Kim, Seong-Ho;Lee, Seong-Ryong;Gang, Jeong-Gyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.6
    • /
    • pp.494-501
    • /
    • 2001
  • In this paper an ANFIS(Adativo Neuro-Fuzzy Inference System)- based fault detection and diagnosis for a closed loop control system is proposed. The proposed diagnostic system contains two ANFIS. One is run as a parallel model within the model in closed loop control(MCL) and the other is run as a series-parallel model within the process in closed loop(PCL) for the generation of relevant symptoms for fault diagnosis. These symptoms are further processed by another classification logic with simple rules and neural network for process and controller fault diagnosis. Experimental results for a DC shunt motor control system illustrate the effectiveness of the proposed diagnostic scheme.

  • PDF

Development of Expert System for the Fault Diagnosis of Chemical Facility System (화학설비 시스템의 이상고장진단을 위한 Expert System의 개발)

  • Oh, Jae-Eung;Shin Jun;Shin, Ki-Hong;Kim, Doo-Hwan;Kim, Woo-Taek;Lee, Chung-Hwi
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.639-642
    • /
    • 2000
  • Chemical facility system have dangerous elements that can injure the human like an explosion and a fire, gas poisoning by a leakage of the harmful chemical material. In addition to a vibration of the machine occurs the leakage. Therefore, the chemical factory requires for periodic monitoring of the vibration. But, until now, the operator has executed a monitoring of the machine by the senses. So, the diagnostic expert system by which the operator can judge easily and expertly a condition of the machine is developed. This paper describes the structure of diagnostic system and the diagnostic algorithm using fuzzy inference

  • PDF