• Title/Summary/Keyword: Diagnostic Screening Scale

Search Result 41, Processing Time 0.02 seconds

Screening and Assessment Tools for Measuring Delirium in Patients with Cancer in Hospice and Palliative Care: A Systematic Review

  • Yang, Eun Jung;Hahm, Bong-Jin;Shim, Eun-Jung
    • Journal of Hospice and Palliative Care
    • /
    • v.24 no.4
    • /
    • pp.214-225
    • /
    • 2021
  • Purpose: This study reviewed screening and assessment tools that are used to measure delirium in patients with cancer in hospice and palliative care settings and examined their psychometric properties. Methods: Four databases were searched for studies using related search terms (delirium, tools, palliative care, cancer, and others). The inclusion criteria were a) studies that included screening/assessment tools for measuring delirium in cancer patients receiving hospice/palliative care, and b) studies published in English or Korean. The exclusion criteria were a) studies that were conducted in an intensive care setting, and b) case studies, qualitative studies, systematic reviews, or meta-analyses. Results: Out of the 81 studies identified, only 10 examined the psychometric properties of tools for measuring delirium, and 8 tools were ultimately identified. The psychometric properties of the Memorial Delirium Assessment Scale (MDAS) were the most frequently examined (n=5), and the MDAS showed good reliability, concurrent validity, and diagnostic accuracy. The Delirium Rating Scale had good reliability and diagnostic accuracy. The Delirium Rating Scale-Revised 98 also showed good reliability and structural validity, but its diagnostic performance was not examined in hospice/palliative care settings. The Nursing Delirium Screening Scale showed relatively low diagnostic accuracy. Conclusion: The MDAS showed evidence of being a valid assessment tool for assessing delirium in patients with cancer in palliative care. Few studies examined the diagnostic performance of delirium tools. Therefore, further studies are needed to examine the diagnostic performance of screening/assessment tools for the optimal detection of delirium in patients with cancer in hospice/palliative care.

A Systematic Review of Validation Studies on Depression Rating Scales in Korea, with a Focus on Diagnostic Validity Information : Preliminary Study for Development of Korean Screening Tool for Depression (국내 우울증 평가도구 타당화 연구의 체계적 고찰-진단적 타당성을 중점으로 : 한국형 우울 선별 도구 개발을 위한 예비 연구)

  • Jung, Sooyun;Kim, Shin-Hyang;Park, Kiho;Jaekal, Eunju;Lee, Won-Hye;Choi, Younyoung;Lee, Seung-Hwan;Choi, Kee-Hong
    • Anxiety and mood
    • /
    • v.13 no.2
    • /
    • pp.53-59
    • /
    • 2017
  • Reliable and valid diagnostic screening tools in the primary care setting enable accurate estimation of depression in individuals at risk or in need of treatment, and provide patients with an opportunity to receive optimal treatments. Although there have been extensive studies on screening tools for depression used in domestic mental health settings, there is little consideration and lack of a thorough review of the diagnostic validity of screening tools. In the current review, we selected 13 representative screening tools for depression which were evaluated in a total of 19 validation studies conducted in Korea. We summarized DSM-5 target domains, diagnostic indices, sensitivity, specificity, cut-off scores, and diagnostic validity information for each tool. Finally, the depression measurement expert group was constituted to evaluate the current status of screening tools for depression, and their recommendations for a new screening tool were summarized. This study was conducted as part of the Mental Health Technology Development project to develop the Korean screening tool for depression (K-DEP).

Comparison of the Autism Diagnostic Observation Schedule and Childhood Autism Rating Scale in the Diagnosis of Autism Spectrum Disorder: A Preliminary Study

  • Park, Hyung Seo;Yi, So Young;Yoon, Sun Ah;Hong, Soon-Beom
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.29 no.4
    • /
    • pp.172-177
    • /
    • 2018
  • Objectives: We examined the agreement between the Autism Diagnostic Observation Schedule (ADOS) and the Childhood Autism Rating Scale (CARS) in the diagnosis of autism spectrum disorder. Methods: The ADOS and CARS scores of 78 children were retrospectively collected from a chart review. A correlation analysis was performed to examine the concurrent validity between the two measures. Using the receiver operating characteristic (ROC) curve, we determined the optimal cut-off score of the CARS for identifying autism spectrum disorder. Results: The CARS score was significantly correlated with the ADOS score (r=0.808, p<0.001). Taking ADOS as the ideal standard, the optimal cut-off scores of CARS for identifying autism and autism spectrum were 30 and 24.5, respectively. Conclusion: We determined the optimal cut-off scores of CARS for screening and diagnosing autism spectrum disorder.

Analysis on the Results of Developmental Screening Test in One Public Health Center (일개 시 보건소의 영유아 성장발달 스크리닝 결과 분석)

  • Bang Kyung-Sook;Kim Yong-Soon;Park Jee-Won;Lee Hea-Jung
    • Child Health Nursing Research
    • /
    • v.8 no.3
    • /
    • pp.302-312
    • /
    • 2002
  • This descriptive exploratory study was conducted to analyze the results of developmental screening test using DDST and the follow-up diagnostic evaluation in one public health center, and to evaluate the feasibility of developmental screening in nursing. Samples were 373 children under 6 years who visited the public health center. Mothers' satisfaction on the developmental clinic was also determined. Summaries of the results were as follows:v 1. 0.5% of children in height and 1.9% of children in weight were included in below 3 percentile of Korean children's growth chart, but none of them showed developmental delay. 2. The results of DDST showed 92.1% of subjects were classified as normal, 3.7% as abnormal, and 4.2% as questionable among 354 children. 3. Most of children who showed the abnormal development at the first DDST were confirmed having the developmental delay at the follow-up diagnostic evaluation. On the other hand, most of children who showed the questionable development at the first DDST revealed having the normal development in follow-up screening test. 4. The result of the DDST was influenced by the birth order of the subject and delivery type. 5.The mean satisfaction score by mothers on developmental clinic was 4.35 in 5 Likert scale. In conclusion, we could certain the feasibility and usefulness of developmental screening in community and child care nursing. To fulfil the increasing needs of mothers with infants on the child development, nurses have to provide anticipatory guidance and parent education in addition to the developmental screening test. We hope to expand the developmental screening in nursing field not only of clinical setting but also of community.

  • PDF

Study on Standardization of Korean Version of Psychiatric Diagnostic Screening Questionnaire(K-PDSQ) (한국판 정신장애 진단 선별 질문지의 표준화 연구)

  • Choi, Hyeong-Keun;Jung, Sung-Won;Jo, Hyun-Ju;Kim, Jeong-Bum;Jung, Chul-Ho
    • Anxiety and mood
    • /
    • v.9 no.1
    • /
    • pp.31-37
    • /
    • 2013
  • Objective : The PDSQ is a brief and psychometrically strong self-report scale designed to screen for common DSM-IV Axis I disorders in clinical settings. In this study, the K-PDSQ was compared with the M.I.N.I.-Plus (Mini-International Neuropsychiatric Interview-Plus) for diagnostic validity and availability of the K-PDSQ as a part of standardization of the K-PDSQ. Methods : The 640 patients were evaluated with the K-PDSQ and the M.I.N.I.-Plus. Diagnosing with the M.I.N.I.-Plus, the diagnostic correspondence, administering time, sensitivity, specificity, ROC curve, and AUC of the K-PDSQ were evaluated. Results : For the diagnostic correspondence of the K-PDSQ, Cohen's kappa coefficient was .66 between the K-PDSQ and the M.I.N.I.-Plus. The administering time of the K-PDSQ was $18.2{\pm}11.80$ minutes. Both sensitivity and specificity of the K-PDSQ were higher: the mean sensitivity across 10 subscales of K-PDSQ was 86%; the mean specificity was 84%. All AUCs of each subscale were above .80, which were statistically significant. Conclusion : The K-PDSQ is valid and available as a diagnostic screening tool. It will be widely used in clinical settings for screening DSM-IV Axis I diagnosis because of its simplicity and high reliability.

A Survey on Utilization of Questionnaires for Assessing Statues of Yin Deficiency Syndrome (음허증 평가 설문지의 국내외 활용 현황조사)

  • Park, Se-Won;Nam, Dong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.2
    • /
    • pp.63-74
    • /
    • 2014
  • Objectives The purpose of this study was to survey the current status of use of questionnaires for evaluating Yin Deficiency Syndrome and analyze the comparison with questionnaires. Methods We searched online medical databases to find domestic/international articles using questionnaires for evaluating intensity of Yin Deficiency Syndrome. Finally 18 articles were collected to be reviewed and they were classified according to their subjects and type of the Questionnaires. Results Out of 18 articles, 11 were based on the Yin-Deficiency Questionnaire (Yin-DQ) and the others used various questionnaires, except the Yin-DQ, for assessing Yin Deficiency Syndrome. In Korea the Yin-DQ was used widely but in foreign countries, for instance, China, Taiwan, a variety of questionnaires were used. Conclusion The Yin-DQ had a wider use in assessing Yin Deficiency Syndrome, but cut-off score for diagnostic criteria was not defined. Therefore, we decided that the YDS (Yin Deficiency Scale) with cut-off score was more suitable for screening patients with Yin Deficiency Syndrome. Moreover, we suggested that additional studies on using the YDS and developing more appropriate diagnostic tool should be conducted to improve diagnostic objectivity.

Adenosine Deaminase - a Novel Diagnostic and Prognostic Biomarker for Oral Squamous Cell Carcinoma

  • Kelgandre, Deepak Chandrakant;Pathak, Jigna;Patel, Shilpa;Ingale, Pramod;Swain, Niharika
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1865-1868
    • /
    • 2016
  • Background: The number of patients with oral cancer in India is increasing gradually (especially in younger people). Although the diagnostic modalities and therapeutic management of oral cancer are improving, the treatment outcome and prognosis of oral cancer remain poor. The absence of definite early warning symptoms for most head and neck cancers suggests that sensitive and specific biomarkers are likely to be important in screening for high-risk patients. Aims: To analyze serum adenosine deaminase (ADA) levels in oral squamous cell carcinoma (OSCC) cases who reported to our institute. Materials and Methods: A prospective study was performed on 100 histopathologically proven cases of OSCC (study group) and 100 normal healthy individuals (control group). Independent sample and one sample t-tests and one way ANOVA followed by Tuckey's POST HOC test were conducted for analysis. Results: Statistically significant increase in serum ADA levels was observed in OSCC cases compared to the control group. Also serum ADA level increased significantly with the histopathological grade. Conclusions: Serum ADA levels in OSCC may be a useful diagnostic and prognostic biomarkers in clinical practice and our findings suggest that a large-scale study is warranted to confirm clinical utility as a prognostic and diagnostic biomarker.

Validity Study on the Early Screening Test for Birth-36 Month Old Children (0-36개월 영아발달선별 검사도구의 타당성에 대한 연구)

  • Seo, So-Jung;Ha, Ji-Young;Chang, Hye-Sung
    • Korean Journal of Child Studies
    • /
    • v.29 no.5
    • /
    • pp.13-30
    • /
    • 2008
  • This study aimed to examine the reliability and validity of a diagnostic instrument to be used to measure the developmental level of very young children (aged birth through 36 months) and to screen young children at risk. The subjects of this study were 861 young children. Data were analyzed by item response distribution, item discrimination, reliability, and validity of the scale. Items reflected the developmental level of each age group. Overall internal consistency was relatively high (Cronbach's ${\alpha}=.90{\sim}.95$), and test-retest (after 2 weeks) reliability was high. Content validity was examined by a panel of experts in the related field. The construct validity as well as the concurrent validity of this instrument was also established.

  • PDF

DNA Methylation Biomarkers for Nasopharyngeal Carcinoma: Diagnostic and Prognostic Tools

  • Jiang, Wei;Cai, Rui;Chen, Qiu-Qiu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8059-8065
    • /
    • 2016
  • Nasopharyngeal carcinoma (NPC) is a common tumor in southern China and south-eastern Asia. Effective strategies for the prevention or screening of NPC are limited. Exploring effective biomarkers for the early diagnosis and prognosis of NPC continues to be a rigorous challenge. Evidence is accumulating that DNA methylation alterations are involved in the initiation and progression of NPC. Over the past few decades, aberrant DNA methylation in single or multiple tumor suppressor genes (TSGs) in various biologic samples have been described in NPC, which potentially represents useful biomarkers. Recently, large-scale DNA methylation analysis by genome-wide methylation platform provides a new way to identify candidate DNA methylated markers of NPC. This review summarizes the published research on the diagnostic and prognostic potential biomarkers of DNA methylation for NPC and discusses the current knowledge on DNA methylation as a biomarker for the early detection and monitoring of progression of NPC.

Screening Tool for Anxiety Disorders: Development and Validation of the Korean Anxiety Screening Assessment

  • Kim, Yeseul;Park, Yeonsoo;Cho, Gyeongcheol;Park, Kiho;Kim, Shin-Hyang;Baik, Seung Yeon;Kim, Cho Long;Jung, Sooyun;Lee, Won-Hye;Choi, Younyoung;Lee, Seung-Hwan;Choi, Kee-Hong
    • Psychiatry investigation
    • /
    • v.15 no.11
    • /
    • pp.1053-1063
    • /
    • 2018
  • Objective This study evaluated the psychometric properties of the Korean Anxiety Screening Assessment (K-ANX) developed for screening anxiety disorders. Methods Data from 613 participants were analyzed. The K-ANX was evaluated for reliability using Cronbach's alpha, item-total correlation, and test information curve, and for validity using focus group interviews, factor analysis, correlational analysis, and item characteristics based on item response theory (IRT). The diagnostic sensitivity and specificity of the K-ANX were compared with those of the Beck Anxiety Inventory (BAI) and Generalized Anxiety Disorder 7-item scale (GAD-7). Results The K-ANX showed excellent internal consistency (${\alpha}=0.97$) and item-total coefficients (0.92-0.97), and a one-factor structure was suggested. All items were highly correlated with the total scores of the BAI, GAD-7, and Penn State Worry Questionnaire. IRT analysis indicated the K-ANX was most informative as a screening tool for anxiety disorders at the range between 0.8 and 1.6 (i.e., top 21.2 to 5.5 percentiles). Higher sensitivity (0.795) and specificity (0.937) for identifying anxiety disorders were observed in the K-ANX compared to the BAI and GAD-7. Conclusion The K-ANX is a reliable and valid measure to screen anxiety disorders in a Korean sample, with greater sensitivity and specificity than current measures of anxiety symptoms.