Study on the Burr Formation in Drilling a Thick Plate (후판의 Drill가공에 있어서 Burr의 생성에 관한 연구)

  • Choe, Seong-Kyu;Yang, Gyun-Eui;Kim, Tae-Yeong;Seo, Nam-Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.3 no.3
    • /
    • pp.30-39
    • /
    • 1986
  • The burr worsens the accuracy of a workpiece and decreases a lot of pro- ductivity because it takes so much time and efforts to remove it. In this paper, the height, thickness and size of a drilling burr were derived from the drilling variables of drill diameter, chisel edge angle, web rate =($\Frac{2{\times}\;web\;thickness}{drill\;dia}$) and yielding stress of the workpiece as wel as feed, point angle and helix angle. The theoretical and experimental values of drilling thrust, torque and burr size of the testpiece were analyzed with the method of numerical analysis in a standard drilling condition. The order of choosing the drilling variables for the purpose of controlling the burr size was dealt in this paper with burr forming ratio. The results are as follows: (1) The drill diameter forms 42 percents feed 25 percents point angle 23 percents and web rate, chisel edge angle and gelix angle 5 percents of the partial differential slope of drilling thrust within the usual available ranges of drilling variables. (2) The drill diameter forms 55 percents feed 26 percents web rate 9 percents and chisel edge angle, point angle and helix angle 10 percents of the par- tial differential slope of drilling torque in the usual available ranges of drilling variables. (3) About 70 percents of the burr size can be controlled by feed, 29 percents by web rate in the case of a fixed diameter. It is recommended drilling10 variables to be chosen in the order of feed, web rate, drill diameter, point angle, chisel edge angle and helix angle so as to control the burr size effectively.

  • PDF

Biotoxic Cyanobacterial Metabolites Exhibiting Pesticidal and Mosquito Larvicidal Activities

  • Kumar, Ashok;Dhananjaya P. , Singh;Tyagi, M.B.
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.1
    • /
    • pp.50-56
    • /
    • 2003
  • A freshwater bloom-forming cyanobacterium, Microcystis aeruginosa, and local soil isolate Scytonema sp. strain BT 23 were demonstrated to contain biotoxic secondary metabolites with pesticidal and mosquito larvicidal activities. A purified toxic constituent from M aeruginosa showed an absorption maximum at 230 nm and its toxicity symptoms, Rf value on TLC, and retention time observed ill an HPLC analysis were similar to those of the hepatotoxic heptapeptide microcystin-LR. The bioactive constituent of the Scytonema sp. was less polar in nature and exhibited two peaks at 240 and 285 m. When applied to two cruciffrous pests, Pieris brassicae and Plutella flostella, the crude extracts and toxic principles from the two cyanobacteria showed significant antifeedant activity in a no-choice bioassay, and at higher concenuations exhibited contact toxicity to the insect larvae. The purified toxin from M. aeruginosa was found to be more effective and produced 97.5 and $92.8\%$ larval mortality in the two pests, fo11owing 2 h of toxin treatment at a concentration of $25{\mu}g$ Per leaf disc (2.5 cm dia.). Meanwhile, similar treatment with the purified toxin from Sytonema sp. stain BT 23 only produced 73 and $78\%$ mortality in the two pests. The cyanobacterial constituents also showed significant activity against Culex and Anopheles larvae. The M. aeruginosa toxin ($20{\mu}g\;ml^-1$) caused 98.2 and $88.1\%$ mortality in the Culex and Anopheles larvae, respectively, while the purified toxin from the Sytonema sp. was less toxic and only produced a 96.3 and $91.2\%$ mortality, respectively, at a much higher concentration ($40{\mu}g\;ml^-1$). Accordingly, the current results point to certain hitherto unknown biological properties of cyanobacterial biotoxins.

A Prediction Model of Droplet Size of Rotary Spray Dryer at Various Operating Conditions (원심식(遠心式) 분무건조장치(噴霧乾燥裝置)의 작동조건(作動條件)에 따른 분무입자(噴霧粒子)의 입도예측(粒度豫測) 모델)

  • Noh, S.H.;Kim, K.B.;Lee, J.W.;Lee, S.J.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.3
    • /
    • pp.229-236
    • /
    • 1992
  • In an effort to localize the spray-dryer which is markedly used for drying food materials, a experiment was carried out with a wheel type atomizer locally designed and manufactured to evaluate the effect of rotational speed, feed rate and physical properties of liquid food material on the droplet size, and to develop a model to predict the droplet size sprayed at various operational conditions. The result are summarized as follows. 1. The frequency of droplet size sprayed from the atomizer at every treatment were similar to normal distributions. 2. Under the test conditions adopted in this study, that is, rotational speed of the atomizer ranging from 15,000 to 20,000 rpm (55.0 m/sec - 73.3 m/sec), feed rate from 14 to 37 kg/hr and viscosity of the material from 1.14 to 350 cP, the mean volume-surface dia. of droplets was decreased as increase in rotational speed and was not affected significantly by the feed rate and viscosity. 3. Through the dimensional analysis, a prediction model was developed as follows : $$\frac{Dvs}{r}=K[\frac{Q}{{\mu}r}]^a[\frac{rN^2}{g}]^b[\frac{{\rho}^2r^3g}{{\mu}^2}]^c[\frac{L}{r}]^d$$ and it was proved that the above model was better in degree of fitness than other models reported. 4. A prediction equation for the droplet size sprayed from the atomizer under the test was expressed as follows : $$\frac{Dvs}{r}=0.0215[\frac{Q}{{\mu}r}]^{0.06}[\frac{rN^2}{g}]^{0.3314}[\frac{{\mu}^2}{{\rho}^2r^3g}]^{0.0158}$$.

  • PDF

A STUDY ON THE SURFACE ROUGHNESS AND REFLECTIVITY AFTER POLISHING OF THE MICROFILL, HYBRID COMPOSITE RESINS (Microfill, Hybrid 복합레진 연마 후 표면조도와 광반사율에 관한 연구)

  • Moon, Anne-Jay;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.513-533
    • /
    • 1994
  • The smooth surface after polishing of composite resin contributes to the patient's comfort, and appearance and longevity of the restoration. This study was performed for the quantitative analysis of the effects of the various finishing and polishing instruments on the surface roughness and reflectivity of the microfill, and hybrid composite resins. Cylindrical specimens 2mm thick and 10mm in diameter of Silux Plus, Durafill VS ; Z100, Prisma TPH, Brilliant, and Herculite XR composite resin were polymerized under the matrix strip. 18 specimens for each composite resin materials were divided into 6 groups ; 5 experimental groups were abraded with # 600 sand paper to remove resin-rich layer, except control. Thereafter, using diamond bur(Mani Dia-Burs), carbide bur(E. T. carbide set 4159), rubber point(Composite polishing kit), aluminum-oxide disk(Sof-Lex disk), polishing paste(Enhance system) ; each specimen was polished to its best achievable surface according to manufacturer's directions. Final polished surfaces were evaluated for the surface roughness with profilometer(${\alpha}$-step 200, Tencor instruments, USA) and for the reflectivity with image analyser(Omniment Image Analyser, Buehler, USA). The results were as follows. 1. Polishing paste or aluminum-oxide disk finish in the microfill, and hybrid composite resins was as smooth as matrix strip finish on the surface roughness test. 2. Polishing paste or aluminum-oxide disk finish in the microfill ; polishing paste finish in the hybrid composite resins was as reflective as matrix strip finish on the refectivity test. 3. For the polishing paste, there were no significant differences between the composite resin materials on the surface roughness and refectivity tests. 4. For the aluminum-oxide disk, the best result was obtained with the microfill composite resin on the surface roughness and reflectivity test. 5. Diamond bur, carbide bur, and rubber point were inappropriate for the final polishing instruments.

  • PDF

Plugger temperature of cordless heat carriers according to the time elapsed

  • Chang, Hoon-Sang;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.12.1-12.7
    • /
    • 2018
  • Objective: The purpose of this study was to measure the temperature of the plugger tip of 3 cordless heat carriers set at $200^{\circ}C$. Materials and Methods: Pluggers of the same taper (0.06, 0.08, 0.10) and similar tip sizes (sizes of 50 and 55) from 3 cordless heat carriers, namely SuperEndo-${\alpha}^2$(B & L Biotech), Friendo (DXM), and Dia-Pen (Diadent), were used and an electric heat carrier, System B (SybronEndo), was used as the control. The plugger tips were covered with customized copper sleeves, heated for 10 seconds, and the temperature was recorded with a computerized measurement system attached to a K-type thermometer at room temperature (n = 10). The data were analyzed with 2-way analysis of variance at a 5% level of significance. Results: The peak temperature of the plugger tips was significantly affected by the plugger taper and by the heat carrier brand (p < 0.05). The peak temperature of the plugger tips was between $177^{\circ}C$ and $325^{\circ}C$. The temperature peaked at $207^{\circ}C-231^{\circ}C$ for the 0.06 taper pluggers, $195^{\circ}C-313^{\circ}C$ for the 0.08 taper pluggers, and $177^{\circ}C-325^{\circ}C$ for the 0.10 taper pluggers. Only 5 of the 12 plugger tips showed a temperature of $200^{\circ}C{\pm}10^{\circ}C$. The time required to reach the highest temperature or $200^{\circ}C{\pm}10^{\circ}C$ was at least 4 seconds. Conclusion: When using cordless heat carriers, clinicians should pay attention to the temperature setting and to the activation time needed to reach the intended temperature of the pluggers.

A Study on the Tool Wear and Prediction of CBN, Poly Crystal and Single Crystal Diamond Tools in Cutting of Nickel (니켈절삭시 CBN, 소결 및 단결정 다이아몬드 공구의 마멸과 예측에 관한 연구)

  • 성기석;김정두
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.120-130
    • /
    • 1993
  • Generally, the machinability of materials that have a good mechanical properties is poor. For materials having a high strength, high toughness, high strength in high temperature and wear resistance, it is difficult to remove a chip from work materials. These properties are well shown in a Nickel, so this metal is used in machine materials, semi-conductor industry, metal mold and optical fields etc. But it is limitted in use because of high cost and poor machinability. In this study, the cutting of pure Nickel was conducted to examine wear of CBN, poly crystal diamond (PCD) and single crystal diamond (SCD) tools. From the result, the CBN tool is superior to poly crystal diamond tools or single crystal diamond tools in terms of tool wear and tool wear is predictable from experimental data base.

Effect of surface treatment on the mechanical properties of nickel-titanium files with a similar cross-section

  • Kwak, Sang Won;Lee, Joo Yeong;Goo, Hye-Jin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.216-223
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical properties of various nickel-titanium (NiTi) files with similar tapers and cross-sectional areas depending on whether they were surface-treated. Materials and Methods: Three NiTi file systems with a similar convex triangular cross-section and the same ISO #25 tip size were selected for this study: G6 (G6), ProTaper Universal (PTU), and Dia-PT (DPT). To test torsional resistance, 5 mm of the straightened file's tip was fixed between polycarbonate blocks (n = 15/group) and continuous clockwise rotation until fracture was conducted using a customized device. To evaluate cyclic fatigue resistance, files were rotated in an artificial curved canal until fracture in a dynamic mode (n = 15/group). The torsional data were analyzed using 1-way analysis of variance and the Tukey post-hoc comparison test, while the cyclic fatigue data were analyzed using the Mann-Whitney U test at a significance level of 95%. Results: PTU showed significantly greater toughness, followed by DPT and G6 (p < 0.05). G6 showed the lowest resistance in ultimate torsional strength, while it showed a higher fracture angle than the other files (p < 0.05). In the cyclic fatigue test, DPT showed a significantly higher number of cycles to failure than PTU or G6 (p < 0.05). Conclusions: Within the limitations of this study, it can be concluded that the torsional resistance of NiTi files was affected by the cross-sectional area, while the cyclic fatigue resistance of NiTi files was influenced by the surface treatment.

ULTRASTRUCTURAL ANALYSIS OF TOOTH PULP AFFERENTS TERMINALS IN THE MEDULLARY DORSAL HORN OF THE RAT (치수유래 구심성 신경섬유의 삼차신경 감각핵군에서의 연접특성)

  • Bae, Yong-Chul;Lee, Eun-Hee;Choy, Min-Ki;Hong, Su-Hyung;Kim, Hyun-Jung;Na, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.219-227
    • /
    • 2001
  • Little is known about processing mechanism of pain sensation of the oral cavity at the 1st synapse of trigeminal sensory nuclei. Serial ultrathin sections of tooth pulp afferent terminals, identified by the transganglionic transport of 1% wheatgerm agglutinin conjugated horseradish peroxidase, were investigated with electron microscope. Quantitative ultrastructural analysis was performed on digitizing tablet connected to Macintoshi personal computer (software; NIH Image 1.60, NIH, Bethesda, MD). Labeled boutons could be classified into two types by the shapes of containing vesicles : S bouton, which contained mainly spherical vesicles (Dia. 45-55 nm) and few large dense cored vesicles (Dia, 80-120nm), and LDCV bouton, which contained spherical vesicles as well as large number of large dense cored vesicles. Most of the parameters on the ultrastructural characteristic and synaptic organization of labeled boutons were similar between S and LDCV boutons, except shapes of containing vesicles. Majority of the labeled boutons showed simple synaptic arrangement. The labeled boutons were frequency presynaptic to dendritic spine, and to a lesser extent, dendritic shaft. They rarely synapsed with soma and adjacent proximal dendrite. A small proportion of labeled boutons made synaptic contacts with presynaptic, pleomorphic vesicles containing endings and synaptic triad. Morphometric parameters of labeled boutons including volume and surface area, total apposed area, mitochondrial volume, active zone area, vesicle number and density showed wide variation and these were not significantly different between S and LDCV boutons. The present study revealed characteristic features on ultrastructure and synaptic connection of pulpal afferents which may involved in transmission of oral pain sensation.

  • PDF

Analysis of Differentially Expressed Genes by Resveratrol Using Membrane Microarray (Membrane Microarray를 이용한 Resveratrol에 의해 차별적으로 발현되는 유전자 군의 분석)

  • Kim, Jong-Sik;Jang, Min-Jung;Kim, Hyo-Eun;Kim, Soon-Young;Kim, Byung-Oh;Sohn, Ho-Yong
    • Journal of Life Science
    • /
    • v.17 no.8 s.88
    • /
    • pp.1115-1120
    • /
    • 2007
  • In the present study, we investigated whether several phytochemicals (resveratrol, genistein, epicatechin gallate, dially disulfide, caffeic acid phenetyl ester) and sulindac sulfide could induce expression of tumor suppressor p53 protein in human colorectal HCT116 cells. We found that p53 was dramatically induced by all phytochemical treatments except sulindac sulfide. Among treated phytochemicals, we selected resveratrol for further experiments because it is one of the highest p53 inducer. Using a Western blot analysis, we found that resveratrol induced p53 in a dose- and time-dependent manner. Additionally, using membrane-based microarray analysis, we found that twenty-five genes were up-regulated and two genes were down-regulated by resveratrol treatment. Among the up-regulated genes, we selected 4 genes and performed reverse-transcription-PCR to confirm microarray data. The results of RT-PCR were highly accorded with those of membrane microarray. In addition, we found that thrombospondin-1 (TSP-1) expression was not dependent on p53 presence, whereas mammary serine protease inhibitor (MASPIN) expression was dependent on p53 expressed by resveratrol treatment. The results of this study may help to promote our understandings of the molecular mechanisms of chemoprevention that are mediated by resveratrol in human colorectal cancer.

Genome-wide Methylation Analysis and Validation of Cancer Specific Biomarker of Head and Neck Cancer (전장유전체수준 메틸레이션 분석을 통한 두경부암 특이 메틸레이션 바이오마커의 발굴)

  • Chang, Jae Won;Park, Ki Wan;Hong, So-Hye;Jung, Seung-Nam;Liu, Lihua;Kim, Jin Man;Oh, Taejeong;Koo, Bon Seok
    • Korean Journal of Head & Neck Oncology
    • /
    • v.33 no.1
    • /
    • pp.21-29
    • /
    • 2017
  • Methylation of CpG islands in the promoter region of genes acts as a significant mechanism of epigenetic gene silencing in head and neck squamous cell carcinoma (HNSCC). DNA methylation markers are particularly advantageous because DNA methylation is an early event in tumorigenesis, and the epigenetic modification, 5-methylcytosine, is a stable mark. In the present study, we assessed the genome-wide preliminary screening and were to identify novel methylation biomarker candidate in HNSCC. Genome-wide methylation analysis was performed on 10 HNSCC tumors using the Methylated DNA Isolation Assay (MeDIA) CpG island microarray. Validation was done using immunohistochemistry using tissue microarray of 135 independent HNSCC tumors. In addition, in vitro proliferation, migration/invasion assays, RT-PCR and immunoblotting were performed to elucidate molecular regulating mechanisms. Our preliminary validation using CpG microarray data set, immunohisto-chemistry for HNSCC tumor tissues and in vitro functional assays revealed that methylation of the Homeobox B5 (HOXB5) and H6 Family Homeobox 2 (HMX2) could be possible novel methylation biomarkers in HNSCC.