• Title/Summary/Keyword: Dew-Condensation

Search Result 67, Processing Time 0.031 seconds

Interpretation on Internal Microclimatic Characteristics and Thermal Environment Stability of the Royal Tombs at Songsanri in Gongju, Korea (공주 송산리 고분군 내부의 미기후 특성 및 온열환경 안정성 해석)

  • Kim, Sung Han;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.35 no.2
    • /
    • pp.99-115
    • /
    • 2019
  • The Royal Tombs at Songsanri is one of the most important historic site for ancient historical study in Korean Peninsula. Since the excavation of the tombs, continuous exposure to the outside environment and the negative effects of the artificial air conditioning system have caused significant threats to the thermal environment stability of the tombs. Unlike the outside temperature that shows significant differences according to seasonal changes, the burial chamber of the tombs had a relatively stable temperature range of 11.4 to $22.2^{\circ}C$ throughout the year, and the standard deviation of temperature was within 3.5. It was revealed that major factors affecting the microclimate of the tombs were inflow of outdoor air, wind direction and speed, and all of them had closely related to airtightness of the tombs. The solar radiation was in inverse proportion to the thickness of burial mounds, and thus Royal Tomb of King Muryeong, which has the thickest burial mound, was least affected by solar radiation. Especially, microclimate of the tombs caused to the highest influence with artificial environmental changes due to access by people, which varied in proportion to the number of accessed people and time of stay. Currently, the inside of the tombs are sealed and always in saturated condition, it is very vulnerable to dew condensation. As a result of analyzing the possibility of condensation in each tomb, all the tomb No. 5, tomb No. 6 and Royal Tomb of King Muryeong had condensation most of the time throughout the year. It is required to make a proper conservation environment for the Royal Tombs at Songsanri.

Fabrication of a Hybrid Superhydrophobic/superhydrophilic Surface for Water Collection: Gravure Offset Printing & Colloidal Lithography (수분수집을 위한 초발수/초친수 복합 표면 제작: 그라비아 옵셋 프린팅과 콜로이달 리소그래피 공정)

  • Ji, Seung-Muk;Kim, In-Young;Kim, Eun-Hee;Jung, Jie-Un;Kim, Wan-Doo;Lim, Hyun-Eui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.1
    • /
    • pp.19-24
    • /
    • 2012
  • We demonstrate the desert beetle back mimicking hybrid superhydrophilic/superhydrophobic patterned surface by using the combination method of colloidal lithography and gravure offset printing for nano and micro patterning, respectively. The two methods are cost-effective and industrially available techniques compared to the other nano/micro patterning methods. To verify the water collecting function of the hybrid surface, the water condensation behavior is investigated on the chilled surface in ambient temperature and high humidity. Due to the synergetic effect of drop and film wise condensation, the hybrid superhydrophobic/superhydrophilic surface shows the higher efficiency than one of single wettability surfaces. The work is underway to get the good patterns of hybrid surfaces for water collecting from the dew or fog.

A study on road ice prediction algorithm model and road ice prediction rate using algorithm model (도로 노면결빙 판정 알고리즘 연구와 알고리즘을 활용한 도로 결빙 적중률 연구)

  • Kang, Moon-Seok;Lim, Hee-Seob;Kwak, A-Mi-Roo;Lee, Geun-hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.1355-1369
    • /
    • 2021
  • This study improved the algorithm for the road ice prediction algorithm and analyzed the prediction rate when comparing actual field measurement data and algorithm prediction value. For analysis, road and weather conditions were measured in Geumdong-ri, Sinbuk-myeon, Pocheon-si. First algorithm selected previous research result algorithm. And the 4th algorithm was improved according to the actual freezing conditions and measured values. Finally, five algorithms were developed: freezing by condensation, freezing by precipitation, freezing by snow, continuous freezing, and freezing by wind speed. When forecasting using an algorithm at the Pocheon site, the freezing hit rate was improved to 93.2%. When calculating the combination ratio for the algorithm. the algorithm for freezing due to condensation and the continuation of the frozen state accounted for 95.7%.

Finite Element Analysis of Adiabatic Properties for the Wall System in Wood Frame House (유한요소법을 이용한 벽체의 단열 성능 분석)

  • Shim, Kug-Bo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.48-57
    • /
    • 1995
  • 본 연구에서는 경골 목조 주택 (2${\times}$4 주택, 2${\times}$6 주택), 통나무 주택 및 콘크리트 주택(내단열, 중단열, 외단열) 벽체에 대하여 유한 요소 해석으로 단열 성능을 평가하였고, 표면 결로 현상을 분석하여 다음과 같은 결론을 얻었다. 1. 벽체의 단열 성능은 정량 골조 2${\times}$6를 사용한 주택이 가장 우수하였고, 경량 골조 2${\times}$4 주택, 통나무 주택, 콘크리트 주택의 순으로 감소하는 것으로 나타났다. 2. 콘크리트 벽체의 내단열, 중단열, 외단열의 벽체 구성법에 따른 단열 성능의 차이는 없었으며, 콘크리트 주택에서 단열재의 사용이 필수적이었다. 3. 내부 결로의 경우 콘크리트 벽체의 외단열이 가장 우수한 결로 예방성을 보였다. 이는 외부에 설치된 단열층이 외부의 낮은 온도를 차단해 벽체 전체의 온도를 높게 유지하기 때문이었다. 표면 결로는 모든 벽체에서 나타나지 않았지만, 실내 습도가 높아진다면 콘크리트 주택의 벽체에서 발생할 가능성이 가장 높았다. 본 연구는 벽체내의 단열 성능에 관하여만 분석을 하였고, 열전달 외에 축열성능 등에 관한 고려는 하지 않았으므로 추후에는 여러 가지 복합적인 열적 성능에 관한 연구가 수행되어야 하리라고 생각한다.

  • PDF

Performance Prediction of Heat Exchanger for Waste Heat Recovery from Humid Flue Gases (습증기를 포함한 연소가스의 폐열회수를 위한 열교환기 성능 예측)

  • Jeong, Dong-Woon;Lee, Sang-Yong;Lee, Han-Ju
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.276-281
    • /
    • 2000
  • A simulation program using the mass transfer correlation was constructed to analyze 1-D simplified condensing flow across the tube bank. Higher efficiency was anticipated by reducing the flue gas temperature down below the dew point where the water vapor in the flue gas is condensed at the surface of the heat exchanger; that is, the heat transfer by the latent heat is added to that by the sensible heat. Thus, there can be an optimum operating condition to maximize the heat recovery from the flue gas. The temperature rises of the flue gas and the cooling water between the inlet and the outlet of the tube bank were compared with the experimental data reported previously. The predicted results agree well with the experimental data. Using this simulation program, the parametric studies have been conducted fur various operating conditions, such as the velocities and temperatures of the vapor/gas mixture and the cooling water, the number of the rows, and the conductivity of the wall material.

  • PDF

An Experimental Study on the Optimization of Performance Parameter for Membrane Based Dehumidification and Air Conditioning System (분리막 제습공조 시스템의 성능변수 최적화를 위한 실험적 연구)

  • Jang, Jeachul;Kang, Eun-Chul;Jeong, Siyoung;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.75-80
    • /
    • 2016
  • There are three types of dehumidification systems : refrigeration dehumidification method, desiccant dehumidification method and hybrid dehumidification method. The first method involves removing moisture by condensation below the dew point, the second method involves absorption by a desiccant material and the last is an integration method. However, the refrigeration dehumidification system consumes too much power and controlling the humidity ratio is difficult. The desiccant dehumidification system uses less power but it has problems of environmental pollution. The hybrid dehumidification system has the disadvantage of a high initial cost. On the other hand, the energy consumption of the membrane based dehumidification system is lower than for the refrigeration dehumidification system. Also, it is an environmentally friendly technology. In this study, the performance parameters are evaluated for the dehumidification system using a hollow fiber membrane. Available area, duct side dry-bulb temperature, sweep gas flux (flow rate) and LMPD (Log Mean Pressure Difference) were used as the performance parameters.

Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System (공조기가 설치된 고분 내에서의 열 및 음 환경 평가)

  • Park, Jin-Yang;Jun, Hee-Ho;Jun, Yong-Du;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.

Study on the Growth of Monoclinic VO2 Phase Applicable for Thermochromic Ceramic Tile

  • Jung, DaeYong;Kim, Ungsoo;Cho, Wooseok
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.5
    • /
    • pp.361-365
    • /
    • 2015
  • Vanadium dioxide ($VO_2$) of monoclinic phase exhibits Metal Insulator Phase Transition (MIPT) phenomenon involving a sharp change in electrical and optical properties at $68^{\circ}C$. Solution-based process is applied to form uniform $VO_2$ coating layer on ceramic tiles. This can selectively block the near-infrared light to possibly reduce the energy loss and prevent dew condensation caused by the temperature difference. Heat treatment conditions including temperature and dwell time were examined to obtain a monoclinic $VO_2$ single phase. Both rutile and monoclinic $VO_2$ phases were observed from in the tiles post-annealed below $700^{\circ}C$. Desired monoclinic $VO_2$ single phase was grown in the tiles heat treated at $750^{\circ}C$. Nano facets of irregular size were observed in the monoclinic $VO_2$ phase involving the phase-transition. Grain growth of monoclinic $VO_2$ phase was observed as a function of dwell time at $750^{\circ}C$.

Investigation on the Properties of a Microcellular Light-Weighted Humidity Controlling Tile (마이크로셀룰라 경량 조습타일의 특성 고찰)

  • Song, In-Hyuck;Lee, Eun-Jung;Kim, Hai-Doo;Kim, Young-Wook;Yun, Dal-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.5
    • /
    • pp.404-411
    • /
    • 2011
  • The humidity controlling ceramic materials was developed by applying the phenomena of dew condensation in the capillary. It is said that the humidity range which human feels comfortable is from 40 to 70% in relative humidity. In this study, the ceramic tile using natural soils such as diatomite for interior wall was investigated. In particular, we had introduced novel processing routes for fabricating microcellular ceramics tile using hollow microsphere as a pore former. The microcellular pores in the humidity controlling ceramic materials showed the superior properties such as light-weight, heat insulation. The cell density was ${\sim}1.0{\times}10^9$ cells/$cm^3$ and density of sample was 0.65 g/$cm^3$ in the case of 1.71 wt% hollow microsphere content. Also, it is observed that the BET surface area and the pore volume of the sintered diatomite tile have the values of 40.92 $m^2$/g and 0.173 $cm^3$/g.

Application of BIPV System Functioned as Solar Collector (태양열 집열기 기능을 갖는 BIPV 시스템의 응용)

  • Min, Sung-Hye;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.953-958
    • /
    • 2006
  • Perimeter zone has been reinforced by active systems, such as fan-coil units, because it causes an increase in heating and cooling loads, dew condensation in winter, or discomfort with cold-draft to residents in buildings, through poor insulation by light-weighed skin due to progressing multi-storied buildings and skyscrapers. However, because these active systems raise Its capacity so that fossil fuel is used as much as they are added, and ultimately, greenhouse effect is urged, we proposed BIPV system functioned as solar collector which can substitute active system. As an early stage, heat balance equation in steady-state by Fortran was used not only for pre-heating effect and electric power capacity during the day in winter, but also for electric power capacity during day in slimmer and sky radiation effect during night in summer. Especially, we should have considered shading on PV, since even a little bit of it makes the efficiency too low for the PV to work. Still, when the flux of pre-heated air was increased to make air-barrier, its temperature was not enough to make it because the speed of heat exchange was too fast to warm up the air, thus the capacity to meet the condition was evaluated, and electric power from PV was made used for it.

  • PDF