• Title/Summary/Keyword: Dew Point Temperature

Search Result 133, Processing Time 0.03 seconds

Non-stationary frequency analysis of monthly maximum daily rainfall in summer season considering surface air temperature and dew-point temperature (지표면 기온 및 이슬점 온도를 고려한 여름철 월 최대 일 강수량의 비정상성 빈도해석)

  • Lee, Okjeong;Sim, Ingyeong;Kim, Sangdan
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.338-344
    • /
    • 2018
  • In this study, the surface air temperature (SAT) and the dew-point temperature (DPT) are applied as the covariance of the location parameter among three parameters of GEV distribution to reflect the non-stationarity of extreme rainfall due to climate change. Busan station is selected as the study site and the monthly maximum daily rainfall depth from May to October is used for analysis. Various models are constructed to select the most appropriate co-variate(SAT and DPT) function for location parameter of GEV distribution, and the model with the smallest AIC(Akaike Information Criterion) is selected as the optimal model. As a result, it is found that the non-stationary GEV distribution with co-variate of exp(DPT) is the best. The selected model is used to analyze the effect of climate change scenarios on extreme rainfall quantile. It is confirmed that the design rainfall depth is highly likely to increase as the future DPT increases.

A Study on the Effect of Hot Lines and the Assembly of Flange for a Refrigerator to Reduce Dew Generation (냉장고 Flange부 이슬 맺힘 방지를 위한 열선의 영향 및 조립에 관한 연구)

  • Kim, Na Hyun;Cho, Jong Rae;Park, Sang Hu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • When the temperature of a flange in a refrigerator is reduced to the dew point, condensation is generated on the flange. Generally, hot lines, having a temperature of $35^{\circ}C$, are located near the flange to increase its surface temperature above the dew point. Hot lines are installed in close contact with the flange in order to increase the heat transfer from the hot lines to the flange surface. Through this work, the effects of the hot line shape and installation conditions, including a gap between the hot line and flange, and the function of a spacer in the inner case of the refrigerator were investigated. Additionally, an optimal shape of the inner case for easy assembling is proposed considering the contact between the hot line and flange.

Development and Verification of the Fog Stability Index for Incheon International Airport based on the Measured Fog Characteristics (인천국제공항의 안개 특성에 따른 안개 안정 지수 FSI(Fog Stability Index) 개발 및 검증)

  • Song, Yunyoung;Yum, Seong Soo
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.443-452
    • /
    • 2013
  • The original Fog Stability Index (FSI) is formulated as FSI=$2(T-T_d)+2(T-T_{850})+WS_{850}$, where $T-T_d$ is dew point deficit (temperature-dew point temperature), $T-T_{850}$ is atmospheric stability measure (temperature-temperature at 850 hPa altitude) and $WS_{850}$ is wind speed at 850 hPa altitude. As a way to improve fog prediction at Incheon International Airport (IIA), we develop the modified FSI for IIA, using the meteorological data at IIA for two years from June 2011 to May 2013, the first one year for development and the second one year for validation. The relative contribution of the three parameters of the modified FSI is 9: 1: 0, indicating that $WS_{850}$ is found to be a non-contributing factor for fog formation at IIA. The critical success index (CSI) of the modified FSI is 0.68. Further development is made to consider the fact that fogs at IIA are highly influenced by advection of moisture from the Yellow Sea. One added parameter after statistical evaluation of the several candidate parameters is the dew point deficit at a buoy over the Yellow Sea. The relative contribution of the four parameters (including the new one) of the newly developed FSI is 10: 2: 0.5: 6.4. The CSI of the new FSI is 0.50. Since the developmental period of one year is too short, the FSI should be refined more as the data are accumulated more.

Climatological Analysis of Fog Occurrence at Chuncheon (춘천지방에서 발생한 안개 특성 분석)

  • Baek, Seung-Joo;Lee, Kwi-Ok;Leem, Heon-Ho;Lee, Hwa-Woon
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.583-591
    • /
    • 2007
  • In this study, meteorological characteristics concerning the occurrence of fog are analyzed using 4-years (2000-2003) data at Chuncheon. From the analysis of meteorological characteristics, the fog at Chuncheon occurred before sunrise time and disappeared after that time and lasted for 2-4 hours. When fog occurred, on the whole, wind direction was blew the northerly and wind speed was below 2.1 m/s. Especially, about 42 % of foggy day fell on the calm($0{\sim}0.2m/s$) conditions. The difference between air temperature and dew point temperature near the surface were mainly less than $2^{\circ}C$. For the lack of water surface temperature, the water sur-face temperature was calculated by using Water Quality River Reservoir System (WQRRS). In Chuncheon, there is close correlation between the frequency of fog day and outflow from Soyang reservoir and high frequency of occurrence due to the difference between air and cold outlet water temperature.

Development and Validation of the Coupled System of Unified Model (UM) and PArameterized FOG (PAFOG) (기상청 현업 모형(UM)과 1차원 난류모형(PAFOG)의 접합시스템 개발 및 검증)

  • Kim, Wonheung;Yum, Seong Soo
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.149-154
    • /
    • 2015
  • As an attempt to improve fog predictability at Incheon International Airport (IIA) we couple the 3D weather forecasting model currently operational in Korea Meteorological Administration (regional Unified Model, UM_RE) with a 1D turbulence model (PAFOG). The coupling is done by extracting the meteorological data from the 3D model and properly inserting them in the PAFOG model as initial conditions and external forcing. The initial conditions include surface temperature, 2 m temperature and dew point temperature, geostrophic wind at 850 hPa and vertical profiles of temperature and dew point temperature. Moisture and temperature advections are included as external forcing and updated every hr. To validate the performance of the coupled system, simulation results of the coupled system are compared to those of the 3D model alone for the 22 sea fog cases observed over the Yellow Sea. Three statistical indices, i.e., Root Mean Square Error (RMSE), linear correlation coefficient (R) and Critical Success Index (CSI), are examined, and they all indicate that the coupled system performs better than the 3D model alone. These are certainly promising results but more improvement is required before the coupled system can actually be used as an operational fog forecasting model. For the RMSE, R, and CSI values for the coupled system are still not good enough for operational fog forecast.

Theoretical and Experimental Considerations of Thermal Humidity Characteristics

  • Choi, Seok-Weon;Cho, Ju-Hyeong;Seo, Hee-Jun;Lee, Sang-Seol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.9-18
    • /
    • 2002
  • Thermal humidity characteristics were considered theoretically and experimentally. A Simply well-fitted correlation of a saturated vapor pressure-temperature curve of water was introduced based on Antoine equation to make theoretical prediction of relative humidity according to temperature variation. Characteristics of dew point were also examined theoretically and its relation with temperature and humidity was evaluated. The exact mass of water vapor in a specified humidity and temperature condition was estimated to provide useful insight into the idea about how much amount of water corresponds to a specified humidity and temperature condition in a confined system. A simple but well-fitting model of dehumidification process was introduced to anticipate the trend of relative humidity level during GN2(gaseous nitrogen) purge process in a humidity chamber. Well-suitedness of this model was also verified by comparison with experimental data. The overall appearance and specification of two thermal humidity chambers were introduced which were used to perform various thermal humidity tests in order to yield useful data necessary to support validity of theoretical models.

Canopy Microclimate of Water-Seeding Rice during Internode Elongation Period (담수직파 벼의 신장기 군락내 미기후 특성)

  • Yun, Jin-Il;Shin, Jin-Chul;Yun, Yong-Dae;Park, Eun-Woo;Cho, Seong-In;Hwang, Heon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.4
    • /
    • pp.473-482
    • /
    • 1997
  • Temperature, humidity and wetness duration were monitored for fully developed paddy rice canopies with 3 different structures induced by the seeding method(puddled-soil drill seeding, DS ; hand broadcasting, HB ; machine broadcasting, MB). Within-canopy air temperature averaged over "clear sky" hours during the study period(maximum tillering through heading) was lower than the screen temperature at a nearby standard weather station, especially in the night. The same trend was true for "overcast sky" hours except the diurnal distinction. Vapor pressure within the canopy was high during the daytime and low in the night, making the daytime deviation from outside the canopy more significant on clear days. Under the overcast sky, the canopy maintained a steady 5 to 10% higher vapor pressure than the outside regardless of day or night. Daily maximum temperature was observed to be higher within the canopies with more leaf mass, making MB the highest, HB the lowest, and DS in between. Relative humidity was over 90% in the night and dropped to 70% in the mid-afternoon, but vapor pressure within the canopy was highest at around 13:00 LST. Dew point depression was lowest and, combined with the temperature, the relative humidity was highest in HB. Mean period of wetting duration was in the order of DS>HB>MB, while the dew point depression was greatest in DS.

  • PDF

Research on Liquefaction Characteristics of SF6 Substitute Gases

  • Yuan, Zhikang;Tu, Youping;Wang, Cong;Qin, Sichen;Chen, Geng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2545-2552
    • /
    • 2018
  • $SF_6$ has been widely used in high voltage power equipment, such as gas insulated switchgear (GIS) and gas insulated transmission line (GIL), because of its excellent insulation and arc extinguishing performance. However, $SF_6$ faces two environmental problems: greenhouse effect and high liquefaction temperature. Therefore, to find the $SF_6$ substitute gases has become a research hotspot in recent years. In this paper, the liquefaction characteristics of $SF_6$ substitute gases were studied. Peng-Robinson equation of state with the van der Waals mixing rule (PR-vdW model) was used to calculate the dew point temperature of the binary gas mixtures, with $SF_6$, $C_3F_8$, $c-C_4F_8$, $CF_3I$ or $C_4F_7N$ as the insulating gas and $N_2$ or $CO_2$ as the buffer gas. The sequence of the dew point temperatures of the binary gas mixtures under the same pressure and composition ratio was obtained. $SF_6/N_2$ < $SF_6/CO_2$ < $C_3F_8/N_2$ < $C_3F_8/CO_2$ < $CF_3I/N_2$ < $CF_3I/CO_2$ < $c-C_4F_8/N_2$ < $C_4F_7N/N_2$ < $c-C_4F_8/CO_2$ < $C_4F_7N/CO_2$. $SF_6/N_2$ gas mixture showed the best temperature adaptability and $C_4F_7N/CO_2$ gas mixture showed the worst temperature adaptability. Furthermore, the dew point temperatures of the $SF_6$ substitute gases at different pressures and the upper limits of the insulating gas mole fraction at $-30^{\circ}C$, $-20^{\circ}C$ and $-10^{\circ}C$ were obtained. The results would supply sufficient data support for GIS/GIL operators and researchers.