• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.034 seconds

2D and 3D Hand Pose Estimation Based on Skip Connection Form (스킵 연결 형태 기반의 손 관절 2D 및 3D 검출 기법)

  • Ku, Jong-Hoe;Kim, Mi-Kyung;Cha, Eui-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1574-1580
    • /
    • 2020
  • Traditional pose estimation methods include using special devices or images through image processing. The disadvantage of using a device is that the environment in which the device can be used is limited and costly. The use of cameras and image processing has the advantage of reducing environmental constraints and costs, but the performance is lower. CNN(Convolutional Neural Networks) were studied for pose estimation just using only camera without these disadvantage. Various techniques were proposed to increase cognitive performance. In this paper, the effect of the skip connection on the network was experimented by using various skip connections on the joint recognition of the hand. Experiments have confirmed that the presence of additional skip connections other than the basic skip connections has a better effect on performance, but the network with downward skip connections is the best performance.

Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems (집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰)

  • Kim, Jun-tae;Kim, Ju-hee;Joo, Kyu-tai;Kim, Kyung-ah;Ryu, Ok-su;Jo, Jae-hyun;Jeong, Jin-Hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.164-177
    • /
    • 2022
  • Medical device usability evaluation refers to the evaluation of medical devices through actual users before the final prototype production is completed. IEC 62366, one of the international safety standards for electronic medical devices, is a standard that must be applied to obtain medical device licenses in major advanced countries such as Europe and the United States. In Korea, through the Ministry of Food and Drug Safety's notice, from January 2021, sequential application by grade has been implemented. In this study, 15 participant specialists were recruited through the Incheon G University Hospital Medical Device Convergence Center for formative evaluation during user suitability evaluation of the focused ultrasound stimulation system being developed by Icleo Co., Ltd., and the test was conducted through joint scenario development. . In the result of task performance, the performance rate was 90.67%, and after the completion of the performance, 86.67% of 'Easy user interface' and 94% of 'Identification/Readability/Understanding of information' questions in the participant survey results analysis by question. The response rate was above average.

V-band CPW 3-dB Directional Coupler using Tandem Structure (Tandem구조를 이용한 V-band용 CPW 3-dB 방향성 결합기)

  • Moon Sung-Woon;Han Min;Baek Tae-Jong;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.7 s.337
    • /
    • pp.41-48
    • /
    • 2005
  • We design and fabricate 3-dB tandem directional coupler using the coplanar waveguide structure which is applicable to balanced amplifiers and mixers for 60 GHz wireless local area network system. The coupler comprises the multiple-sectional parallel-coupled lines to facilitate the fabrication process, and enable smaller device size and higher directivity than those of the conventional 3-dB coupler employing the edge-coupled line. In this study, we adopt the structure of two-sectional parallel-coupled lines of which each single-coupled line has a coupling coefficient of -8.34 dB and airbridge structure to monolithically materialize the uniplanar coupler structure instead of using the conventional multilayer or bonded structure. The airbridge structure also supports to minimize the parasitic components and maintain desirable device performance in V-band (50$\~$75 GHz). The measured results from the fabricated couplers show couplings of 3.S$\~$4 dB and phase differences of 87.5$^{\circ}{\pm}1^{\circ}$ in V-band range and show directivities higher than 30 dB at a frequency of 60 GHz.

Effect of Guide Vane on the Performance of Impulse Turbine for Wave Energy Conversion

  • HYUN BEOM-SOO;MOON JAE-SEUNG;HONG SEOK-WON
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.6 s.61
    • /
    • pp.1-7
    • /
    • 2004
  • This paper deals with the performance analysis of the impulse turbine for a owe type wave energy conversion device. Numerical analysis was performed using the commercially-available software FLUENT. This parametric study includes variation of the setting angle of the guide vane. Since parametric study at various flow coefficients requires a tremendous amount of computing time, two-dimensional cascade flow approximation was employed to determine the optimum principal particulars in a rather simple manner. A Full three-dimensional calculation was also performed for several cases to confirm the validity of the two-dimensional approach. Results were compared to other experimental data, such as Setoguchi et al. (2001)'s extensive set of data, and found that the usefulness of 2-D analysis was well demonstrated. The advantages of each method were also evaluated.

Development of SiGe Heterostructure Epitaxial Growth and Device Fabrication Technology using Reduced Pressure Chemical Vapor Deposition (저압화학증착을 이용한 실리콘-게르마늄 이종접합구조의 에피성장과 소자제작 기술 개발)

  • Shim, K.H;Kim, S.H;Song, Y.J;Lee, N.E;Lim, J.W;Kang, J.Y
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.4
    • /
    • pp.285-296
    • /
    • 2005
  • Reduced pressure chemical vapor deposition technology has been used to study SiGe heterostructure epitaxy and device issues, including SiGe relaxed buffers, proper control of Ge component and crystalline defects, two dimensional delta doping, and their influence on electrical properties of devices. From experiments, 2D profiles of B and P presented FWHM of 5 nm and 20 nm, respectively, and doses in 5×10/sup 11/ ∼ 3×10/sup 14/ ㎝/sup -2/ range. The results could be employed to fabricate SiGe/Si heterostructure field effect transistors with both Schottky contact and MOS structure for gate electrodes. I-V characteristics of 2D P-doped HFETs revealed normal behavior except the detrimental effect of crystalline defects created at SiGe/Si interfaces due to stress relaxation. On the contrary, sharp B-doping technology resulted in significant improvement in DC performance by 20-30 % in transconductance and short channel effect of SiGe HMOS. High peak concentration and mobility in 2D-doped SiGe heterostructures accompanied by remarkable improvements of electrical property illustrate feasible use for nano-sale FETs and integrated circuits for radio frequency wireless communication in particular.

Study on the Correlation between Sasang Constitution and the Data of Pulse Diagnosis Device - A Systematic Review in Korean Articles - (사상체질과 맥진기 검사 결과와의 상관성에 대한 연구 - 국내 논문에 대한 체계적 고찰 -)

  • Lee, Hye Yoon;Jung, A Ram;Son, Han Beom;Hwang, Man Suk;Lee, Jeong Won;Kim, Gyeong Cheol;Yun, Young Ju
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.5
    • /
    • pp.621-629
    • /
    • 2012
  • This study aimed to examine the possibility of data from pulse diagnosis device to be used for diagnosis of Sasang constitution. Systematic searches of 5 major Korean medical database were conducted for articles published up to May 2012. Searching key word was "Sasang" or "Constitution". Studies dealt with correlation between Sasang constitution and the pulse wave data from pulse diagnosis machine were included. Totally 2886 studies are searched and 3 studies are added from references of evaluated articles. Among them, 12 studies were met our inclusion criteria (2 Xishu Mac, 2 Self-made pulse diagnosis machine, 8 3D-Mac). Three of the eight 3D-Mac studies intended to develop a formula of constitutional differential diagnosis, 2 studies compared variables by Sasang constitution in healthy group and 3 studies compared variables by Sasang constitution in healthy group and special disease group. They all reported some significant variables, however results are not consistent between studies. The accuracy of the formula of constitutional differential diagnosis using 3D-Mac pulse diagnosis devices is 46.0% by now. Improvements in measuring pulse are required to achieve more accurate result and be used for diagnosis of Sasang constitution. Compensating B.M.I. among Sasang constitutional groups and separating constitutional pulse factors from acquired characteristics are also needed in further study.

Asymmetrical Hearing Loss and Related Factors Among the Noise Exposed Male Workers (소음 노출 남성근로자에서 청력 역치의 비대칭성과 관련요인)

  • Lee, Nam-Soo;Lee, Kyung-Jae;Kim, Joo-Ja
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.2
    • /
    • pp.94-101
    • /
    • 2010
  • This study was performed to examine the asymmetry of hearing loss among the noise exposed male workers. Findings of otoscopic examination, pure tone audiometry and tympanometry were evaluated for 179 male workers working in the noise exposed workplace. And also selfadministered structured questionnaires were used for each worker's work-related and general characteristics including personal health behaviors. There were significant differences of hearing threshold between right and left ears at 1,000 Hz and 3,000 Hz(p<0.05). And also significant differences of hearing threshold were noted in the age group over 50 at 3,000 Hz, the high risk drinking group either at 3,000 Hz and 4,000 Hz, the work duration group 10-19 years at 3,000 Hz, the noise exposure group under 90 dB(A) at 3,000 Hz, the noise exposure group over 90 dB(A) at 1,000 Hz, the non-wearing protective device group at 4,000 Hz, and the wearing protective device group at 3,000 Hz(p<0.05). Further study is needed to explore the extent and the related factors of the asymmetry of hearing loss in the general population and occupationally noise exposed group.

Design and Its Applications of a Hypercube Grid Quorum for Distributed Pub/Sub Architectures in IoTs (사물인터넷에서 분산 발행/구독 구조를 위한 하이퍼큐브 격자 쿼럼의 설계 및 응용)

  • Bae, Ihnhan
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1075-1084
    • /
    • 2022
  • Internet of Things(IoT) has become a key available technology for efficiently implementing device to device(D2D) services in various domains such as smart home, healthcare, smart city, agriculture, energy, logistics, and transportation. A lightweight publish/subscribe(Pub/Sub) messaging protocol not only establishes data dissemination pattern but also supports connectivity between IoT devices and their applications. Also, a Pub/Sub broker is deployed to facilitate data exchange among IoT devices. A scalable edge-based publish/subscribe (Pub/Sub) broker overlay networks support latency-sensitive IoT applications. In this paper, we design a hypercube grid quorum(HGQ) for distributed Pub/Sub systems based IoT applications. In designing HGQ, the network of hypercube structures suitable for the publish/subscribe model is built in the edge layer, and the proposed HGQ is designed by embedding a mesh overlay network in the hypercube. As their applications, we propose an HGQ-based mechansim for dissemination of the data of sensors or the message/event of IoT devices in IoT environments. The performance of HGQ is evaluated by analytical models. As the results, the latency and load balancing of applications based on the distributed Pub/Sub system using HGQ are improved.

A Study on the Implementation of Register Based VXIbus System (Register Based VXIbus 시스템의 구현에 관한 연구)

  • 노승환;전동근;김성욱;강민호;김덕진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.11
    • /
    • pp.1219-1227
    • /
    • 1992
  • VXIbus is a standard for compatibility of instruments of multi-vendors and originated from the VMEbus. The devices for implementing VXIbus system can be categorized into the register based device and the message based device. In this paper we organized the A/D conversion module and the slot0 module, which form the register based VXIbus subsystem. The A/D conversion module is used as a digital voltmeter and LAN is used for communication between an external control computer and the slot0 module. The SCPI(Standard Commands for Programmable Instruments), which is a standard language for instruments, is transmitted from the external control computer to the slot0 module as the ASCII form, and then to the A/D conversion module after changing to the binary digit command. From the experiment. We verified that the measured voltage can be observed on external control computer and user interface can be improved by the modified graphic processing.

  • PDF

The Fabrication and Characteristics of the Pyroelectric IR Sensor using P(VDF/TrFE) Thin Films Fabricated by the Spin Coating Technique

  • Kwon, Sung-Yeol
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.12C no.4
    • /
    • pp.225-228
    • /
    • 2002
  • The pyroelectric sensor of P(VDF/TrFE) film as sensing materials has been fabricated and evaluated with another commercial pyroelectric sensor using ceramic materials for sensing, The device was mounted in TO-5 housing to detect infrared light of a 5.5~14 ${\mu}{\textrm}{m}$ wavelength. The NEP(noise equivalent power) and specific detectivity D* of the device were 2.13$\times$10$^{-8}$ W and 9.37 10$^{6}$ cm/W under emission energy of 13 ㎼/$\textrm{cm}^2$, respectively.