• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.043 seconds

Required Mowing Power and Bale Density of Miscanthus × Giganteus for Field Biomass Harvesting using Different Methods

  • Jun, Hyeon-Jong;Choi, Il-Su;Kang, Tae-Gyoung;Choi, Yong;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: This study investigated the harvesting properties of the giant miscanthus (Miscanthus ${\times}$ giganteus) to measure the required mowing power for different stem conditioning methods in order to shorten the drying time after mowing and the bale density so that the crop can be used as biomass in the winter season. Methods: The required mowing power and bale density were measured using a power measurement device, three different mower-conditioners, and a mid-sized round baler under different working speeds and conditioning methods. Results: For the various mower-conditioners, the average stem length from mowing was 0.86-0.91 m, and the available working speed was 1.6 m/s. The steel roller-type mower-conditioner showed better stem conditioning but could not mow over a working speed of 1.6 m/s. The required average power of the mower-conditioners varied from 23.8 kW for the steel roller-type rotary disk mower-conditioner with a working width of 2.4 m to 37.2 kW for the flail-type rotary disk mower-conditioner with a working width of 3.2 m at a working speed of 1.6 m/s. The bale densities were $155.8-172.2kg/m^3$. The highest bale density was measured for stems with no conditioning and a moisture content of 11.3% (d.b.) mowed by the rotary disk mower. The bale density was affected by the mowing method because of the low moisture content of the miscanthus stems. Conclusions: In terms of the working performance and conditioning statue, the steel roller-type mower-conditioner is a better choice at a working width of 2.4 m, while the flail finger-type mower-conditioner is better at a working width of 3.2 m. The type of mower-conditioner used for giant miscanthus harvesting should be determined by considering the harvest area, workable period, and working performance of a mower-conditioner and baler during the winter.

Analysis of dimensions and shapes of maxillary and mandibular dental arch in Korean young adults

  • Park, Su-Jung;Leesungbok, Richard;Song, Jae-Won;Chang, Se Hun;Lee, Suk-Won;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.321-327
    • /
    • 2017
  • PURPOSE. The aim of this study was to investigate dental arch dimensions and to classify arch shape in Korean young adults. MATERIALS AND METHODS. The sample included 50 Koreans with age ranging from 24 to 32 years. Maxillary and mandibular casts were fabricated using irreversible hydrocolloid and type III dental stones. Incisor-canine distance, $incisor-1^{st}$ molar distance, $incisor-2^{nd}$ molar distance, intercanine distance, $inter-1^{st}$ molar distance, and $inter-2^{nd}$ molar distance in both the maxillary and mandibular arch were measured using a three-dimensional measuring device. The dental arch was classified into three groups using five ratios from the measured values by the K-means clustering method. The data were analyzed with one-way analysis of variance. RESULTS. Arch lengths (IM2D, $incisal-2^{nd}$ molar distance) were 44.13 mm in the maxilla and 40.40 mm in the mandible. Arch widths (M2W, inter $2^{nd}$ molar width) were 64.12 mm in the maxilla and 56.37 mm in the mandible. Distribution of the dental arch form was mostly ovoid shape (maxilla 52% and mandible 56%), followed by the V-shape and the U-shape. The arch width for the U-shape was broader than for the other forms. CONCLUSION. This study establishes new reference data for dental arch dimensions for young Korean adults. The most common arch form is the ovoid type in the maxilla and mandible of Koreans. Clinicians should be aware of these references and classify arch type before and during their dental treatment for effective and harmonized results in Koreans.

Effect of Antibody Titer on Xenograft Survival in Pig-To-Dog Heterotopic Cardiac Xenotransplantation -Opening of Xenotrasplantation Era- (돼지\longrightarrow개 이소이종심장 이식모델에시 생존에 미치는 항체 역가의 영향 -이종이식시대의 개막-)

  • 이정렬;김희경;김지연;최대영;이재형;위현초;강희정;김영태;강병철
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.391-400
    • /
    • 2004
  • Xenotransplantation in discordant species results in immediate and irreversible hyperacute rejection due to natural antibodies, IgM. With this, antibody depletion is one option to reduce hyperacute rejection, we investigated the effect of PCPP (postcentrifugal plasmapheresis) on the depletion of natural antibodies and the effect of antibody titer on xenograft survival. Material and Method: Outbred swines (n=4) weighing 10∼20 kg were used as donors and mongrel dogs (n=4) weighing 25∼30 kg were used as recipients. Recipient canines underwent plasmapheresis (COBE TPE Laboratories, Lakewood. CO, USA). Pre-transplantation PCPP was peformed on day -2 and day 0. There were three groups (Group 0: no PCPP, Group 1: 1 pla sma-volume (PV) at day -2 and 2 PV at day 0, Group 2: 2 PV at day -2 and 2 PV at day 0). A swine heart was heterotopically transplanted into a recipient's abdominal infrarenal aorta and inferior vena cava. Mean percent depletion of total IgM and IgG in plasma of the recipients was calculated. Serum albumin, electrolyte, complement activity and coagulation factors were measured. Histopathologic examination of heart specimens was performed. Result: Mean percent depletion of IgM and IgG were 95.7$\pm$1.2%, 80.5$\pm$2.4% in the group 2 at the end of PCPP. The percent depletion of serum albumin concentration was decreased from 2.8 to 1.4 g/㎗ in the group 1 and 3.0 to 1.5 g/㎗ in the group 2. Complement hemolytic activity was decreased in group 1 and 2, but returned to normal level within 24 hours. Complement hemolytic activity was reduced to 10% of pre-PCPP level in group 2. Serum fibrinogen decreased to 20% or less and was recovered within 24 hours in group 2. Antithrombin III decreased but less than fibrinogen. PT and aPTT were sometimes but not always prolonged during plasmapheresis. After plasmapheresis, PT and aPTT were prolonged beyond the measurable level. D-dimer was not found during PCPP, but appeared and maintained from 10 minutes after trasplantation. Graft Survival time was 5 min in group 0, and it was 90$\pm$0 min in the group 2. Histopathologic changes were more typically characterized by edema, hemorrhages, thrombosis in all groups at the end of experiment. Conclusion: PCPP effectively removed immuoglobulins and reduced the titer of natural antibodies, as a result, significantly prololonged swine heart xenograft survival.

Analytical Evaluation of PPG Blood Glucose Monitoring System - researcher clinical trial (PPG 혈당 모니터링 시스템의 분석적 평가 - 연구자 임상)

  • Cheol-Gu Park;Sang-Ki Choi;Seong-Geun Jo;Kwon-Min Kim
    • Journal of Digital Convergence
    • /
    • v.21 no.3
    • /
    • pp.33-39
    • /
    • 2023
  • This study is a performance evaluation of a blood sugar monitoring system that combines a PPG sensor, which is an evaluation device for blood glucose monitoring, and a DNN algorithm when monitoring capillary blood glucose. The study is a researcher-led clinical trial conducted on participants from September 2023 to November 2023. PPG-BGMS compared predicted blood sugar levels for evaluation using 1-minute heart rate and heart rate variability information and the DNN prediction algorithm with capillary blood glucose levels measured with a blood glucose meter of the standard personal blood sugar management system. Of the 100 participants, 50 had type 2 diabetes (T2DM), and the average age was 67 years (range, 28 to 89 years). It was found that 100% of the predicted blood sugar level of PPG-BGMS was distributed in the A+B area of the Clarke error grid and Parker(Consensus) error grid. The MARD value of PPG-BGMS predicted blood glucose is 5.3 ± 4.0%. Consequentially, the non-blood-based PPG-BGMS was found to be non-inferior to the instantaneous blood sugar level of the clinical standard blood-based personal blood glucose measurement system.

70nm NMOSFET Fabrication with Ultra-shallow $n^{+}-{p}$ Junctions Using Low Energy $As_{2}^{+}$ Implantations (낮은 에너지의 $As_{2}^{+}$ 이온 주입을 이용한 얕은 $n^{+}-{p}$ 접합을 가진 70nm NMOSFET의 제작)

  • Choe, Byeong-Yong;Seong, Seok-Gang;Lee, Jong-Deok;Park, Byeong-Guk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.95-102
    • /
    • 2001
  • Nano-scale gate length MOSFET devices require extremely shallow source/drain eftension region with junction depth of 20∼30nm. In this work, 20nm $n^{+}$-p junctions that are realized by using this $As_{2}^{+}$ low energy ($\leq$10keV) implantation show the lower sheet resistance of the $1.0k\Omega$/$\square$ after rapid thermal annealing process. The $As_{2}^{+}$ implantation and RTA process make it possible to fabricate the nano-scale NMOSFET of gate length of 70nm. $As_{2}^{+}$ 5 keV NMOSFET shows a small threshold voltage roll-off of 60mV and a DIBL effect of 87.2mV at 100nm gate length devices. The electrical characteristics of the fabricated devices with the heavily doped and abrupt $n^{+}$-p junctions ($N_{D}$$10^{20}$$cm^{-3}$, $X_{j}$$\leq$20nm) suggest the feasibility of the nano-scale NMOSFET device fabrication using the $As_{2}^{+}$ low energy ion implantation.

  • PDF

Conceptual Design of a Portal System for International Shipping's Greenhouse Gas Monitoring, Reporting, and Verification (MRV 규제 대응을 위한 국제해운 에너지 효율 포탈 시스템 개념 설계)

  • Kang, Nam-seon;Lee, Beom-seok;Kim, Sang-yong;Lee, Jung-jin;Yoon, Hyeon-kyu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.108-117
    • /
    • 2016
  • In this paper, a portal system compatible with MRV regulation was designed to monitoring, reporting and verifying $CO_2$ emission and fuel consumption data from an international ship. A portal system supports monitoring and reporting task of international shipping companies and calculates national greenhouse gas inventory. EU MRV law, MRV discussions of IMO, responses of international shipping companies to ship energy efficiency and greenhouse gas regulation, and greenhouse gas statistics on international shipping were analyzed to drive portal system requirements. For ship energy efficiency and $CO_2$ emitted monitoring, a data collection module was designed based on on-board equipment, energy efficiency measuring device and navigation report. Data transfer module with easy management and minimized usage to transfer ship data to shore was designed. A portal system was designed to convert the collected data into the standard reporting format, perform monitoring, statical analysis, verification and auto report generation, and support national greenhouse gas inventory.

Influence of the hydrogen post-annealing on the electrical properties of metal/alumina/silicon-nitride/silicon-oxide/silicon capacitors for flash memories

  • Kim, Hee-Dong;An, Ho-Myoung;Seo, Yu-Jeong;Zhang, Yong-Jie;Kim, Tae-Geun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.122-122
    • /
    • 2008
  • Recently, Metal/Alumina/Silicon-Nitride/Silicon-Oxide/Silicon (MANOS) structures are one of the most attractive candidates to realize vertical scaling of high-density NAND flash memory [1]. However, as ANO layers are miniaturized, negative and positive bias temperature instability (NBTI/PBTI), such as the flat band voltage shift, ${\Delta}V_{FB}$, the interfacial trap density increase, ${\Delta}D_{it}$, the gate leakage current, ${\Delta}I_G$. and the retention characteristics, in MONOS capacitors, becomes an important issue in terms of reliability. It is well known that tunnel oxide degradation is a result of the oxide and interfacial traps generation during FN (Fowler-Nordheim) stress [2]. Because the bias temperature stress causes an increase of both interfacial-traps and fixed oxide charge could be a factor, witch can degrade device reliability during the program and erase operation. However, few studies on NBTI/PBTI have been conducted on improving the reliability of MONOS devices. In this work, we investigate the effect of post-annealing gas on bias temperature instability (BTI), such as the flat band voltage shift, ${\Delta}V_{FB}$, the interfacial trap density shift, ${\Delta}I_G$ retention characteristics, and the gate leakage current characteristics of MANOS capacitors. MANOS samples annealed at $950^{\circ}C$ for 30 s by a rapid thermal process were treated via additional annealing in a furnace, using annealing gases $N_2$ and $N_2-H_2$ (2 % hydrogen and 98 % nitrogen mixture gases) at $450^{\circ}C$ for 30 min. MANOS samples annealed in $N_2-H_2$ ambient had the lowest flat band voltage shift, ${\Delta}V_{FB}$ = 1.09/0.63 V at the program/erase state, and the good retention characteristics, 123/84 mV/decade at the program/erase state more than the sample annealed at $N_2$ ambient.

  • PDF

Removal of Residual Stress and In-vitro Recording Test in Polymer-based 3D Neural Probe (폴리머 기반 3차원 뉴런 프로브의 잔류 스트레스 제거 및 생체 외 신호 측정)

  • Nam, Min-Woo;Lim, Chun-Bae;Lee, Kee-Keun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.2
    • /
    • pp.33-42
    • /
    • 2009
  • A polymer-based flexible neural probe was fabricated for monitoring of neural activities from a brain. To improve the insertion stiffness, a 5 ${\mu}m$ thick biocompatible Au layer was electroplated between the top and bottom polymer layers. The developed neural probe penetrated a gel whose elastic modulus is similar to that of a live brain tissue without any fracture, To minimize mechanical residual stress and bending from the probe, two new methods were employed: (1) use of a thermal annealing process after completing the device and (2) incorporation of multiple different layers to compensate the residual stress between top and bottom layers. Mechanical bending around the probe tip was clearly removed after employing the two processes. In electrical test, the developed probe showed a proper impedance value to record neural signals from a brain and the result remained the same for 72 hours. In simple in-vitro probe characterization, the probe showed a great removal of residual stress and an excellent recording performance. The in-vitro recording results did not change even after 1 week, suggesting that this electrode has the potential for great recording from neuron firing and long-term implant performance.

  • PDF

Characteristics of the ( Pb, La ) $TiO_3$ Thin Films with Pb/La Compositions (Pb/La 조성에 따른 ( Pb, La ) $TiO_3$ 박막의 특성 변화)

  • Kang, Seong-Jun;Joung, Yang-Hee;Yoon, Yung-Sup
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.29-37
    • /
    • 1999
  • In this study, we have prepared PLT thin films having various La concentrations by using sol-gel method and studied on the effect of La concentration on the electrical properties of PLT thin films. As the La concentration increases from 5mol% to 28mol%, the dielectric constant at 10kHz increases from 428 to 761, while the loss tangent decreases from 0.063 to 0.024. Also, the leakage current density at 150kV/cm has a tendency to decrease from 6.96${\mu}A/cm^2$ to 0.79${\mu}A/cm^2$. In the result of hysteresis loops of PLT thin films, the remanent polariation and the coercive field decrease from 9.55${\mu}C/cm^2$ to 1.10${\mu}C/cm^2$ and from 46.4kV/cm to 13.7kV/cm, respectively. With the result of the fatigue test on the PLT thin films, we have found that the fatigue properties are improved remarkably as the La concentration increases from 5 mol% to 28mol%. In particular, the PLT28) has paraelectric phase and its charge storage clensity and leakage current density at 5V are 134fC/${\mu}cm^2$ and 1.01${\mu}A/cm^2$, respectively. The remanent polarization and coercive field of the PLT(10) film are 6.96${\mu}C/cm^2$ and 40.2kV/cm, respectively. After applying of $10^9$ square pulses with ${\pm}5V$, the remanent polarilzation of the PLT(10) film decreases about 20% from the initial state. In the results, we conclude that the 10mol% and the 28mol% La doped PLT thin films are very suitable for the capacitor dielectrics of new generation of DRAM and NVFRAM respecitively.

  • PDF

Hardware Approach to Fuzzy Inference―ASIC and RISC―

  • Watanabe, Hiroyuki
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.975-976
    • /
    • 1993
  • This talk presents the overview of the author's research and development activities on fuzzy inference hardware. We involved it with two distinct approaches. The first approach is to use application specific integrated circuits (ASIC) technology. The fuzzy inference method is directly implemented in silicon. The second approach, which is in its preliminary stage, is to use more conventional microprocessor architecture. Here, we use a quantitative technique used by designer of reduced instruction set computer (RISC) to modify an architecture of a microprocessor. In the ASIC approach, we implemented the most widely used fuzzy inference mechanism directly on silicon. The mechanism is beaded on a max-min compositional rule of inference, and Mandami's method of fuzzy implication. The two VLSI fuzzy inference chips are designed, fabricated, and fully tested. Both used a full-custom CMOS technology. The second and more claborate chip was designed at the University of North Carolina(U C) in cooperation with MCNC. Both VLSI chips had muliple datapaths for rule digital fuzzy inference chips had multiple datapaths for rule evaluation, and they executed multiple fuzzy if-then rules in parallel. The AT & T chip is the first digital fuzzy inference chip in the world. It ran with a 20 MHz clock cycle and achieved an approximately 80.000 Fuzzy Logical inferences Per Second (FLIPS). It stored and executed 16 fuzzy if-then rules. Since it was designed as a proof of concept prototype chip, it had minimal amount of peripheral logic for system integration. UNC/MCNC chip consists of 688,131 transistors of which 476,160 are used for RAM memory. It ran with a 10 MHz clock cycle. The chip has a 3-staged pipeline and initiates a computation of new inference every 64 cycle. This chip achieved an approximately 160,000 FLIPS. The new architecture have the following important improvements from the AT & T chip: Programmable rule set memory (RAM). On-chip fuzzification operation by a table lookup method. On-chip defuzzification operation by a centroid method. Reconfigurable architecture for processing two rule formats. RAM/datapath redundancy for higher yield It can store and execute 51 if-then rule of the following format: IF A and B and C and D Then Do E, and Then Do F. With this format, the chip takes four inputs and produces two outputs. By software reconfiguration, it can store and execute 102 if-then rules of the following simpler format using the same datapath: IF A and B Then Do E. With this format the chip takes two inputs and produces one outputs. We have built two VME-bus board systems based on this chip for Oak Ridge National Laboratory (ORNL). The board is now installed in a robot at ORNL. Researchers uses this board for experiment in autonomous robot navigation. The Fuzzy Logic system board places the Fuzzy chip into a VMEbus environment. High level C language functions hide the operational details of the board from the applications programme . The programmer treats rule memories and fuzzification function memories as local structures passed as parameters to the C functions. ASIC fuzzy inference hardware is extremely fast, but they are limited in generality. Many aspects of the design are limited or fixed. We have proposed to designing a are limited or fixed. We have proposed to designing a fuzzy information processor as an application specific processor using a quantitative approach. The quantitative approach was developed by RISC designers. In effect, we are interested in evaluating the effectiveness of a specialized RISC processor for fuzzy information processing. As the first step, we measured the possible speed-up of a fuzzy inference program based on if-then rules by an introduction of specialized instructions, i.e., min and max instructions. The minimum and maximum operations are heavily used in fuzzy logic applications as fuzzy intersection and union. We performed measurements using a MIPS R3000 as a base micropro essor. The initial result is encouraging. We can achieve as high as a 2.5 increase in inference speed if the R3000 had min and max instructions. Also, they are useful for speeding up other fuzzy operations such as bounded product and bounded sum. The embedded processor's main task is to control some device or process. It usually runs a single or a embedded processer to create an embedded processor for fuzzy control is very effective. Table I shows the measured speed of the inference by a MIPS R3000 microprocessor, a fictitious MIPS R3000 microprocessor with min and max instructions, and a UNC/MCNC ASIC fuzzy inference chip. The software that used on microprocessors is a simulator of the ASIC chip. The first row is the computation time in seconds of 6000 inferences using 51 rules where each fuzzy set is represented by an array of 64 elements. The second row is the time required to perform a single inference. The last row is the fuzzy logical inferences per second (FLIPS) measured for ach device. There is a large gap in run time between the ASIC and software approaches even if we resort to a specialized fuzzy microprocessor. As for design time and cost, these two approaches represent two extremes. An ASIC approach is extremely expensive. It is, therefore, an important research topic to design a specialized computing architecture for fuzzy applications that falls between these two extremes both in run time and design time/cost. TABLEI INFERENCE TIME BY 51 RULES {{{{Time }}{{MIPS R3000 }}{{ASIC }}{{Regular }}{{With min/mix }}{{6000 inference 1 inference FLIPS }}{{125s 20.8ms 48 }}{{49s 8.2ms 122 }}{{0.0038s 6.4㎲ 156,250 }} }}

  • PDF