• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.04 seconds

Spatial variation in quality of Ga2O3 single crystal grown by edge-defined film-fed growth method (EFG 방법으로 성장한 β-Ga2O3 단결정의 영역별 품질 분석)

  • Park, Su-Bin;Je, Tae-Wan;Jang, Hui-Yeon;Choi, Su-Min;Park, Mi-Seon;Jang, Yeon-Suk;Moon, Yoon-Gon;Kang, Jin-Ki;Lee, Won-Jae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.4
    • /
    • pp.121-127
    • /
    • 2022
  • β-Gallium oxide (Ga2O3), an ultra-wide bandgap semiconductor, has attracted great attention due to its promising applications for high voltage power devices. The most stable phase among five different polytypes, β-Ga2O3 has the wider bandgap of 4.9 eV and higher breakdown electric field of 8 MV/cm. Furthermore, it can be grown from melt source, implying higher growth rate and lower fabrication cost than other wide bandgap semiconductors such as SiC, GaN and diamond for the power device applications. In this study, β-Ga2O3 bulk crystals were grown by the edge-defined film-fed growth (EFG) process. The growth direction and the principal surface were set to be the [010] direction and the (100) plane of the β-Ga2O3 crystal, respectively. The spectra measured by Raman an alysis could exhibit the crystal phase an d impurity dopin g in the β-Ga2O3 ingot, and the crystallinity quality and crystal direction were analyzed using high-resolution X-ray diffraction (HRXRD). The crystal quality and various properties of as-grown β-Ga2O3 ribbon was systematically analyzed in order to investigate the spatial variation in entire crystal grown by EFG method.

Development of a Pre-treating Equipment and the Carcass Disposal System for Infected Poultry (감염가금 전처리 및 폐사가축 처리시스템 개발)

  • Hong, J.T.;Kim, H.J.;Yu, B.K.;Lee, S.H.;Hyun, C.S.;Ryu, I.S.;Oh, K.Y.;Kim, S.;Kwon, J.H.;Tack, D.S.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • When we bury the infected poultry into the ground, we have many problems such as the difficulty of making sufficient area for burying, environmental contamination by the leachate, unpleasant ordor. Also, in case of burning the carcass of the infected poultry, there are some problems such as high cost, dust, unpleasant odor, etc. It could cause environmental contamination which many peoples and environmental organization complains about. In this study, we develop a treating system which treats the infected poultry carcass in a environmental method preventing the environment contamination. This system is composed of many processes. The euthanasia system uses rigid vinyl to trap and to do a euthanasia the infected poultry with lethal gas, carbon dioxide. And then, with the tractor attached grappler infected poultry carcass could be put into the carcass treating system. The euthanasia system uses rigid vinyl to trap the infected birds and to confine lethal gas, carbon dioxide. Infected poultry carcass are moved to carcass disposal system by collecting device which is attached at tractor. The carcass treatment system (capacity of disposal : 6.3 $m^3$) is installed on a truck and do one pass work, which is input, crush, stir, sterilize, and discharge treated carcass. 1,000 chickens was killed within 9.7min by $CO_2$ (300L/min) in the tent (10 $m^3$). The collecting device could carry 142 chickens at a time, and the movable carcass treatment system could sterilize 2 tons carcass per hour (at one time). This treatment systems was eco-friendly because it reduced the volume of carcass by 31.9% with no wastewater generation.

Biomechanical Efficacy of a Combined Flexible Cage with Pedicle Screws with Spring rods: A Finite Element Analysis (Spring rod를 사용한 척추경 나사못과 동반 시술된 Flexible cage의 생체역학적 효과)

  • Kim, Y.H.;Park, E.Y.;Kim, W.H.;Hwang, S.P.;Park, K.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • Recently, flexible cages have been introduced in an attempt to absorb and reduce the abnormal load transfer along the anterior parts of the spine. They are designed to be used with the pedicle screw systems to allow some mobility at the index level while containing ROM at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the flexible cage when combined with pedicle screws with flexible rods. The post-operated models were constructed by modifying the L4-5 of a previously-validated 3-D FE model of the intact lumbar spine (L2-S1): (1) Type 1, flexible cage only; (2) Type 2, pedicle screws with flexible rods; (3) Type 3, interbody fusion cage plus pedicle screws with rigid rods; (4) Type 4, interbody fusion cage plus Type 2; (5) Type 5, Type 1 plus Type 2. Flexion/extension of 10 Nm with a compressive follower load of 400N was applied. As compared to the Type 3 (62~65%) and Type 4 (59~62%), Type 5 (53~55%) was able to limit the motion at the operated level effectively, despite moderate reduction at the adjacent level. It was also able to shift the load back to the anterior portions of the spine thus relieving excessively high posterior load transfer and to reduce stress on the endplate by absorbing the load with its flexible shape design features. The likelihood of component failure of flexble cage remained less than 30% regardless of loading conditions when combined with pedicle screws with flexible rods. Our study demonstrated that flexible cages when combined with posterior dynamic system may help reduce subsidence of cage and degeneration process at the adjacent levels while effectively providing stability at the operated level.

Investigation of the tensile behavior of joint filling under experimental test and numerical simulation

  • Fu, Jinwei;Haeri, Hadi;Sarfarazi, Vahab;Marji, Mohammad Fatehi;Guo, Mengdi
    • Structural Engineering and Mechanics
    • /
    • v.81 no.2
    • /
    • pp.243-258
    • /
    • 2022
  • In this paper, tensile behavior of joint filling has been investigated under experimental test and numerical simulation (particle flow code). Two concrete slabs containing semi cylinder hole were prepared. These slabs were attached to each other by glue and one cubic specimen with dimension of 19 cm×15 cm×6 cm was prepared. This sample placed in the universal testing machine where the direct tensile stress can be applied to this specimen by implementing a special type of load transferring device which converts the applied compressive load to that of the tensile during the test. In the present work, two different joint filling thickness i.e., 3 mm and 6 mm were prepared and tested in the laboratory to measure their direct tensile strengths. Concurrent with experimental test, numerical simulation was performed to investigate the effect of hole diameter, length of edge notch, filling thickness and filling length on the tensile behavior of joint filling. Model dimension was 19 cm×15 cm. hole diameter was change in four different values of 2.5 cm, 5 cm, 7.5 cm and 10 cm. glue lengths were different based on the hole diameter, i.e., 12.5 cm for hole diameter of 2.5 cm, 10 cm for hole diameter of 5 cm, 7.5 cm for hole diameter of 7.5 cm and 5 cm for hole diameter of 10 cm. length of edge notch were changed in three different value i.e., 10%, 30% and 50% of glue length. Filling thickness were changed in three different value of 3 mm, 6 mm and 9 mm. Tensile strengths of glue and concrete were 2.37 MPa and 6.4 MPa, respectively. The load was applied at a constant rate of 1 kg/s. Results shows that hole diameter, length of edge notch, filling thickness and filling length have important effect on the tensile behavior of joint filling. In fixed glue thinks and fixed joint length, the tensile strength was decreased by increasing the hole diameter. Comparing the results showed that the strength, failure mechanism and fracture patterns obtained numerically and experimentally were similar for both cases.

A Study on Family Planning Rumors & Practice in Rural Communities (일 농촌지역 가족계획 풍문과 실천에 관한 연구)

  • 추수경
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.2
    • /
    • pp.63-77
    • /
    • 1978
  • Studies pertaining to influential factors on adoption and practice of family planning are very much needed to lower fertility, for family planning has regarded as only one social acceptable means to curb the accelerated population growth. One of the influential factors is known as rumors on family planning methods that hinder the actual practice of family planning. This study generally aimed at disclosing rumors on family planning methods prevalent in rural communities so that one could gain some in sights to cope with the ill effects of rumors to promote family planning Practice in rural communities in Korea. In order to accomplish the general aims this study formulated following four specific objectives; 1. Find out types and frequencies of rumors exposed of contraceptive methods. 2. Find out the relationship between the rumors exposed and socio-economic and demographic characteristics of new village leaders and health workers. 3. Examine the relationship between family planing rumors and family planning practices. The materials for this study were drawn from the two different sets of data gathered in July and Octorber 1977 respectivily by Center for Population & family Planning, Yon sei University. One is current family planning practice among eligible women reaiding in 4 Myuns in Kwang Wha country and the other is Survey on Rumor on family planning method heard by new village leaders and health workers in the four myuns. The four Myuns were divided into 60 small areas. Current family planning practice rate in each small area and as a whole were calculated. The unit of analysis in this study was not the indviduel person but the 55 small areas. Percentage, average, F-Test t-test and a coefficient of correlation were used for statistical analysis. Results of this study could be summarized as follows: 1. Rumors by different method of contraception: Medical complications, gastro-intestinal disorders, and difficulty in usage one most prevalent rumors about oral pills. Around 49% -77% of the 55 areas were often heard and the most frequent rumor was related medical complications of oral pills. Rumors on medical complications and incomplete effect of intrauterines as contraceptive were heard 51-66% of the 55 small areas. Rumors that vasectomy resulted in family problems, for instance infiedelity of spouse were often heard to 44% of the 55 small areas. 2. Rumors by socio-economic and demographic characteristic of new village leader and health workers: Among the demographic characteristics such as sex, age and sex composition of children, sex and age differentials in frequency of rumors heard more observed, Female new village health workers have heard more frequently than male new village leader. (t = 7.137, p> 0.01, d.f. = 53, a coefficient of correlation 0.27, p>0.05) The Younger age group less than 40 years of age have heard rumors of than the group over 40 years old. (t = 7.18, p>0.01, d.f. = 53, a coefficient of correlation 0.27, p>0.05) However, it was not observable that a consistent sex and age differentials in frequency of rumors heard of each contraceptive mettled, But, more female new village health works heard of rumors about intrauterine device than male new village leaders. (t = 0.497, p> 0.01, d.f. = 53, a coefficient of correlatin 0.32, p>0.01) 3. It was found that there was no statistically significant relationship between the frequency of rumors heard and current family planning practices on the whole, However, frequency of rumors heard about vasectomy appeared to have a positive relationship with current practice of vasectomy. A rather consistent pattern of relationship between“requency of rumors heard”and current family practice rate was demonstrated of 10 graphes which showed the relation between the two variagles. The current family planning practice rate in the“never heard”group and “frequently heard”group was equally lower than that in“often heard”group. The relatively consistent ∩ pattern of relationship needs to be farther investigated, for this pattern is different from the relationship that has been assumed to exist between these two variables.

  • PDF

Synthesis and Photovoltaic Properties of Conjugated Polymers Having Push-pull Structure according to the Type of Side-chain in the N-Substituted Phenothiazine (Push-pull 구조의 공액 고분자 합성 및 Phenothiazine의 질소 원자에 치환된 Side-chain에 따른 유기박막태양전지로의 특성 연구)

  • Seong, Ki-Ho;Yun, Dae-Hee;Woo, Je-Wan
    • Applied Chemistry for Engineering
    • /
    • v.25 no.6
    • /
    • pp.624-631
    • /
    • 2014
  • In this study, a new series of conjugated polymer 3-(5-(5,6-bis(octyloxy)-7-(thiophen-2-yl)benzo[c][1,2,5]thiadiazol-4-yl)thiophen-2-yl)-10-(4-(octyloxy)phenyl)-10H-phenothiazine (P1) and 3-(5-(5,6-bis(octyloxy)-7-(thiophen-2-yl)benzo[c][1,2,5]thiadiazol-4-yl)thiophen-2-yl)-10-(4-((2-ethylhexyl)oxy)phenyl)-10H-phenothiazine (P2) were synthesised and organic photovoltaics (OPVs) properties were characterized. The push-pull structure polymer consisted of phenothiazine derivative as an electron donor and benzothiadiazole derivative as an electron acceptor. The aliphatic chain substituted aromatic ring was substituted at the position of N in phenothiazine for the electron-rich and improved solubility. Excellent thermal stabilities of P1 and P2 were confirmed by measured Td values as 321.9 and $323.7^{\circ}C$, respectively and the degrees of polymerization were 4,911 (P1) and 5,294 (P2). The maximum absorption wavelength of P1 and P2 were 549 and 566 nm, respectively. The device was fabricated and the OPVs property was measured. As a result, the power efficiency of conversion for P1 and P2 were 0.96 and 0.90%, respectively.

Development of persimmon harvest apparatus -Development of detachment device (감 수확기구 개발(1) - 탈과장치 개발 -)

  • Woo, D.G.;Kim, T.H.
    • Current Research on Agriculture and Life Sciences
    • /
    • v.27
    • /
    • pp.1-6
    • /
    • 2009
  • Persimmon occupied the second largest cultivation area next to apple among the fruits in Korea. Since 70 % of its cultivating field is located at slope, the efficiency of its harvesting operation is very low. Also, the traditional persimmon harvest apparatus does not seem to be efficient to use due to a structural problem. In this paper, the author has analyzed the physical properties of persimmon friut-stem system and compared detachment force with developed persimmon harvest apparatus and traditional persimmon harvest apparatus in order to solve the problems mentioned above. The results of the research are summarized as follows : 1. The weight of the persimmon is shown as 157 g on average, the lengths of stem's major axis and minor axis is shown as 4.6 mm and 3.7 mm on average, respectively, sectional area of stem is shown as $13.9mm^2$ on average and the stem length is shown as 13.6 mm on average. 2 In case of the traditional persimmon harvest apparatus, the detachment force needed when a persimmon was detached from its stem was shown as 86.3 N on average. 3. In case of the developed persimmon harvest apparatus, detachment force needed when a persimmon was detached from its stem was shown as 72.6 N on average.

  • PDF

Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT (세기조절방사선치료의 환자별 정도관리를 위한 2차원적 선량계의 유용성 평가)

  • Hong, Chae-Seon;Lim, Jong-Soo;Ju, Sang-Gyu;Shin, Eun-Hyuk;Han, Young-Yih;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.91-102
    • /
    • 2009
  • Purpose: To compare the accuracy and efficacy of EDR2 film, a 2D ionization chamber array (MatriXX) and an amorphous silicon electronic portal imaging device (EPID) in the pre-treatment QA of IMRT. Materials and Methods: Fluence patterns, shaped as a wedge with 10 steps (segments) by a multi-leaf collimator (MLC), of reference and test IMRT fields were measured using EDR2 film, the MatriXX, and EPID. Test fields were designed to simulate leaf positioning errors. The absolute dose at a point in each step of the reference fields was measured in a water phantom with an ionization chamber and was compared to the dose obtained with the use of EDR2 film, the MatriXX and EPID. For qualitative analysis, all measured fluence patterns of both reference and test fields were compared with calculated dose maps from a radiation treatment planning system (Pinnacle, Philips, USA) using profiles and $\gamma$ evaluation with 3%/3 mm and 2%/2 mm criteria. By measurement of the time to perform QA, we compared the workload of EDR2 film, the MatriXX and EPID. Results: The percent absolute dose difference between the measured and ionization chamber dose was within 1% for the EPID, 2% for the MatriXX and 3% for EDR2 film. The percentage of pixels with $\gamma$%>1 for the 3%/3 mm and 2%/2 mm criteria was within 2% for use of both EDR2 film and the EPID. However, differences for the use of the MatriXX were seen with a maximum difference as great as 5.94% with the 2%/2 mm criteria. For the test fields, EDR2 film and EPID could detect leaf-positioning errors on the order of -3 mm and -2 mm, respectively. However it was difficult to differentiate leaf-positioning errors with the MatriXX due to its poor resolution. The approximate time to perform QA was 110 minutes for the use of EDR2 film, 80 minutes for the use of the MatriXX and approximately 55 minutes for the use of the EPID. Conclusion: This study has evaluated the accuracy and efficacy of EDR2 film, the MatriXX and EPID in the pre-treatment verification of IMRT. EDR2 film and the EPID showed better performance for accuracy, while the use of the MatriXX significantly reduced measurement and analysis times. We propose practical and useful methods to establish an effective QA system in a clinical environment.

Research for The Environmental Optimization of Dose and Image quality in Digital Radiography (디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구)

  • Lee, Kwang Jae;Kim, MinGi;Lee, Jong Woong;Kim, Ho Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.203-209
    • /
    • 2013
  • Digital Radiography (DR) has improved a quality of resolution based on a wide dynamic range, high detective quantum efficiency (DQE), and modulation transfer function (MTF), compared with film/screen(F/s). Unlike expectation that a low level of radiation can be used in examination, high level of signal to noise ratio(SNR) due to over-exposure caused increase of exposed dose to patients. Also, the auto exposure control (AEC) using Kilovolage(kVp) in F/S can cause over-exposure. Hence, in this study, we proposed a proper method for using DR, in which effect of tubing Kilovolage on device's image, DR MTF measurement with changes of tubing current (mA), and the quantitative evaluation of skull phantom captured images' PSNR were evaluated. Changes of contrast with tubing Kilovolage can be improved by retouching, and MTF changes according to tubing current(1.41~1.39 lp/mm in 50% area, and 3.19~2.8 lp/mm in 10% area) does not influence on resolution of image. As a result, high tubing Kilovoltage, and tubing current will be suitable to use of DR.

Structure and Magnetic Properties of Ho and Ni Co-doped BiFeO3 Ceramics

  • Hwang, J.S.;Yoo, Y.J.;Park, J.S.;Kang, J.H.;Lee, K.H.;Lee, B.W.;Kim, K.W.;Lee, Y.P.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.183-183
    • /
    • 2014
  • Recently, multiferroic materials gain much attention due to their fascinating fundamental physical properties. These materials offer wide range of potential applications such as data storage, spintronic devices and sensors, where both electronic and magnetic polarizations can be coupled. Among single-phase multiferroic materials, $BiFeO_3$ is typical because of the room-temperature magnetoelectric coupling in view of long-range magnetic- and ferroelectric-ordering temperatures. However, $BiFeO_3$ is well known to have large leakage current and small spontaneous polarization due to the existence of oxygen vacancies and other defects. Furthermore the magnetic moment of pure $BiFeO_3$ is very weak owing to its antiferromagnetic nature. Recently, various attempts have been performed to improve the multiferroic properties of $BiFeO_3$ through the co-doping at the A and the B sites, by making use of the fact that the intrinsic polarization and magnetization are associated with the lone pair of $Bi^{3+}$ ions at the A sites and the partially-filled 3d orbitals of $Fe^{3+}$ ions at the B sites, respectively. In this study, $BiFeO_3$, $Bi_{0.9}Ho_{0.1}FeO_3$, $BiFe_{0.97}Ni_{0.03}O_3$ and $Bi_{0.9}Ho_{0.1}Fe_{0.97}Ni_{0.03}O_3$ bulk compounds were prepared by solid-state reaction and rapid sintering. High-purity $Bi_2O_3$, $Ho_2O_3$, $Fe_2O_3$ and $NiO_2$ powders with the stoichiometric proportions were mixed, and calcined at $500^{\circ}C$ for 24 h to produce the samples. The samples were immediately put into an oven, which was heated up to $800^{\circ}C$ and sintered in air for 1 h. The crystalline structure of samples was investigated at room temperature by using a Rigaku Miniflex powder diffractometer. The field-dependent and temperature-dependent magnetization measurements were performed with a vibrating-sample magnetometer and superconducting quantum-interference device.

  • PDF