• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.04 seconds

Propofol Patient-Controlled Sedation Using $Perfusor^{\circledR}$ fm (B. Braun, Germany) Infusion Pump in Dental Patients-Preliminary Study (치과 환자에서의 $Perfusor^{\circledR}$ fm 자가통증조절기를 이용한 Propofol 자가진정조절법)

  • Park, Chang-Joo;Yum, Kwang-Won;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.2 no.2 s.3
    • /
    • pp.97-100
    • /
    • 2002
  • Background: Patient-controlled sedation (PCS) has been blown for a safe and effective sedative method on the same pharmacological concepts of patient-controlled analgesia. Many different kinds of infusion devices have been used but they often have too long nominal infusion rate and lockout time. $Perfuser^{\circledR}$ fm (B. Braun, Germany) is a new PCA device with 999.9 ml/hr nominal infusion rate and minimum 1 min lockout time. In this study, the feasibility of propofol PCS using $Perfuser^{\circledR}$ fm was examined in order to provide a safe satisfactory sedation for dental patients. Methods: Eleven healthy patients presenting for oral surgery were studied. Propofol PCS was performed using $Perfuser^{\circledR}$ fm, which was set to deliver a bolus dose of 5 mg with 999.9 ml/hr nominal infusion rate and 1 min lockout time. Propofol loading dose was randomly assigned to a bolus dose ${\times}$ 0, 2, and 3 (initial bolus). Patients were told to press the bolus button as often as they needed to relieve discomfort. Results: Total infused dose of propofol was mean 1.8 mg/kg/hr and D (Delivery)/A (Attempt) ratio was mean 72.8%. All patients was awake and there were no clinically significant intraoperative side effects during the sedation. Almost all patients were very satisfied with this type of PCS. Conclusion: Propofol PCS using $Perfuser^{\circledR}$ fm infusion pump provided good conscious sedation for dental procedures.

  • PDF

R & D Trends on Direct Formic Acid Fuel Cells (직접 개미산 연료전지의 연구동향)

  • Kwon, Yongchai;Han, Jonghee;Kim, Jinsoo
    • Applied Chemistry for Engineering
    • /
    • v.19 no.6
    • /
    • pp.583-591
    • /
    • 2008
  • Recently, as a demand for the portable device is surged, there are needs to develop a new fuel cell system for replacing the conventionally used secondary battery. For this purpose, it becomes important to develop direct formic acid fuel cell (DFAFC) that uses formic acid as a fuel. The formic acid can offer typical advantages such as excellent non-toxicity of the level to be used as food additive, smaller crossover flux through electrolyte, and high reaction capability caused by high theoretical electromotive force (EMF). With the typical merits of formic acid, the efforts for optimizing reaction catalyst and cell design are being made to enhance performance and long term stability of DFAFC. As a result, to date, the DFAFC having the power density of more than $300mW/cm^2$ was developed. In this paper, basic performing theory and configuration of DFAFC are initially introduced and future opportunities of DFAFC including the development of catalyst for the anode electrode and electrolyte, and design for the optimization of cell structure are discussed.

Experimental Study on the Wear Effects of a Brush Seal in DN 2.5million in a 250℃ High - temperature Steam Environment (DN 250만 250℃고온 스팀환경에서 운전되는 단열 브러쉬 실 마모효과에 관한 실험적 연구)

  • Ha, YunSeok;Ha, TaeWoong;Lee, YoungBok
    • Tribology and Lubricants
    • /
    • v.35 no.2
    • /
    • pp.99-105
    • /
    • 2019
  • This study presents an experimental investigation of the wear and oxidation of the bristles of a brush seal in a super-heated steam environment. We construct a model reflecting normal force and radial interference to predict the amount of wear. To monitor the volume loss of the bristle induced by the swirl phenomenon of the rotor, we measure the clearance between the rotor and the brush seal by using a non-contact 3-D device. We calculate the area by using the area-wise measurement method. Considering the obvious brush seal wear variables, we use two disks with different roughness($Ra=0.1{\mu}m$ and $100{\mu}m$) to determine the effect of roughness on wear. Considering an actual steam turbine, we utilize a steam generator and super-heater to generate a working fluid (0.95MPa, 523.15K) that has high kinetic energy. We observe the abrasion of the bristles in the hot steam environment through a scanning electron microscope image. This study also conducted energy dispersive X-ray (EDX) analysis for a qualitative evaluation of local chemistry. The results indicate that the wear and elimination of bristles occur on the disk with high roughness, and the weight increases due to oxidation. Furthermore these results, reveal that the bristle oxidation is accelerated more under super-heated steam conditions than under conditions without steam.

The Near-Infrared Imaging Spectroscopy to Visualize the Distribution of Sugar Content in the Flesh of a Melon

  • Tsuta, Mizuki;Sugiyama, Junichi;Sagara, Yasuyuki
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1526-1526
    • /
    • 2001
  • To improve the accuracy of sweetness sensor in automated sorting operations, it is necessary to clarify unevenness of the sugar content distribution within fruits. And it is expected that the technique to evaluate the content distribution in fruits contribute to the development of the near-infrared (NIR) imaging spectroscopy. Sugiyama (1999) had succeeded to visualize the distribution of the sugar content on the surface of a half-cut green fresh melon. However, this method cannot be applied to red flesh melons because it depends on information of the absorption band of chlorophyll (676 nm), which is affected by the color of the fresh. The objective of this study was to develop the universal visualization method depends on the absorption band of sugar, which can be applied to various kinds of melons and other fruits. The relationship between the sugar contents and absorption spectra of both green and red fresh melons were investigated by using a NIR spectrometer to determine the absorption band of sugar. The combination of 2$\^$nd/ derivative absorbances at 902 nm and 874 nm was highly correlated with the sugar contents. The wavelength of 902 nm is attributed to the absorption band of sugar. A cooled charge-coupled device (CCD) imaging camera which has 16 bit (65536 steps) A/D resolution was equipped with rotating band-pass filter wheel and used to capture the spectral absorption images of the flesh of a vertically half-cut red fresh melon. The advantage of the high A/D resolution in this research is that each pixel of the CCD is expected to function as a detector of the NIR spectrometer for quantitative analysis. Images at 846 nm, 874 nm, 902 nm and 930 nm were acquired using this CCD camera. Then the 2$\^$nd/ derivative absorbances at 902 nm and 874 nm at each pixel were calculated using these four images. On the other hand, parts of the same melon were extracted for capturing the images and squeezed for the measurement of sugar content. Then the calibration curve between the combination of 2$\^$nd/ derivative absorbances at 902 nm and 874 nm and sugar content was developed. The calibration method based on NIR spectroscopy techniques was applied to each pixel of the images to convert the 2$\^$nd/ derivative absorbances into the Brix sugar content. Mapping the sugar content value of each pixel with linear color scale, the distribution of the sugar content was visualized. As a result of the visualization, it was quantitatively confirmed that the Brix sugar contents are low at the near of the skin and become higher towards the seeds. This result suggests that the visualization technique by the NIR imaging spectroscopy could become a new useful method fer quality evaluation of melons.

  • PDF

Interaction of Antihistaminics with Muscarinic Receptor(I) -Action on the cardiac muscarinic receptor- (항(抗) Histamine제(劑)와 Muscarinic Receptor와의 상호작용(相互作用)(I) -심장(心臟) muscarinic receptor에 대한 작용(作用)-)

  • Lee, Shin-Woong;Park, Yeung-Joo;Lee, Jeung-Soo;Ha, Kwang-Won;Jin, Kap-Duck
    • YAKHAK HOEJI
    • /
    • v.32 no.2
    • /
    • pp.101-111
    • /
    • 1988
  • $[^3H]$ Quinuclidinyl benzilate(QNB) binding assays were performed in the dog ventricular sarcolemma fraction enriched approx. 32-fold in sarcolemma compared to the starting homogenate to elucidate the effect of antihistaminics on cardiac muscarinic receptor. Chlorpheniramine(CHP) inhibited specific binding of $[^3H]$QNB and delayed the equilibrium binding. The rate constants at $37^{\circ}C$ for formation and dissociation of the QNB receptor complex were $0.38{\times}10^9\;M^{-1}$ and $1.6{\times}10^{-2}\;min^{-1}$, respectively. The mean value for the dissociation constant from the pairs of the rate constants was 43. 2 pM and this value was similar to the value(44.8pM) determined from Scatchard analysis. CHP decreased association rate constant, indicating increase in $K_D$ value. Decrease in affinity without affecting the binding site concentration$(B_{max})$ for $[^3H]$QNB binding by CHP was also demonstrated by Scatchard analysis. $K_i$ values for $H_i$-blockers that inhibited specific $[^3H]$QNB binding were $0.02{\sim}4.8{\mu}M$. Cimetidine with $K_i$ value of $230{\mu}M$, however, was ineffective in displacing $[^3H]$QNB binding at concentration of $50{\mu}M$. The Hill coefficient for $H_1$-blockers were about one. The results indicate that $H_1$-antihistaminics inhibit $[^3H]$ QNB binding by interaction with myocardiac muscarinic cholinergic receptor and anticholinergic side effects of these drugs are mainly due to this receptor blocking mechanism.

  • PDF

Development of Standards of Tattoo Machine for Safety and Performance Evaluation (의료용 표시기의 안전성 및 성능 평가를 위한 시험 항목 및 시험방법(안)연구)

  • Kim, Y.G.;Cho, S.K.;Lee, T.W.;Yeo, C.M.;Jung, B.J.;Kwon, Y.M.;Cha, J.H.;Hur, C.H.;Park, K.J.;Kim, D.S.;Kim, H.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.151-157
    • /
    • 2011
  • Tattooing is a performance for decorative and cosmetic marking by placing permanent ink into the skin. As the cultural meaning of tattoo in Korea is changing, the tattoo machines are widely spread n permanent cosmetic market. Though the use of the tattoo machine was increased, the evaluation standards of tattoo machine were not existed. Korea Food and Drug Association regulated the electrical and mechanical safety standards which were founded on the IEC 601-1 second edition. Also they regulated he biological safety standards which were derived from the ISO 10993 series, however, these general valuations of common medical device were insufficient for evaluating tattoo machine. We developed the standards of tattoo machine for safety and performance evaluation for tattoo machine by preliminary hazard analysis in ISO 14971. The evaluation criteria of tattoo machines are focused on the mechanical invasion. We suggested the additional evaluation items of the needle speed, length, vibration with general valuation criteria of common medical device. We anticipate that this research may be a primary stage to figure a standard regulation and evaluation for tattoo machine.

A Personal Sound Amplification Product Compared to a Basic Hearing Aid for Speech Intelligibility in Adults with Mild-to-Moderate Sensorineural Hearing Loss

  • Choi, Ji Eun;Kim, Jinryoul;Yoon, Sung Hoon;Hong, Sung Hwa;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.91-98
    • /
    • 2020
  • Background and Objectives: This study aimed to compare functional hearing with the use of a personal sound amplification product (PSAP) or a basic hearing aid (HA) among sensorineural hearing impaired listeners. Subjects and Methods: Nineteen participants with mild-to-moderate sensorineural hearing loss (SNHL) (26-55 dB HL; pure-tone average, 0.5-4 kHz) were prospectively included. No participants had prior experience with HAs or PSAPs. Audiograms, speech intelligibility in both quiet and noisy environments, speech quality, and preference were assessed in three different listening conditions: unaided, with the HA, and with the PSAP. Results: The use of PSAP was associated with significant improvement in pure-tone thresholds at 1, 2, and 4 kHz compared to the unaided condition (all p<0.01). In the quiet environment, speech intelligibility was significantly improved after wearing a PSAP compared to the unaided condition (p<0.001), and this improvement was better than the result obtained with the HA. The PSAP also demonstrated similar improvement in the most comfortable levels compared to those obtained with the HA (p<0.05). However, there was no significant improvement of speech intelligibility in a noisy environment when wearing the PSAP (p=0.160). There was no significant difference in the reported speech quality produced by either device or in participant preference for the PSAP or HA. Conclusions: The current result suggests that PSAPs provide considerable benefits to speech intelligibility in a quiet environment and can be a good alternative to compensate for mild-to-moderate SNHL.

A Personal Sound Amplification Product Compared to a Basic Hearing Aid for Speech Intelligibility in Adults with Mild-to-Moderate Sensorineural Hearing Loss

  • Choi, Ji Eun;Kim, Jinryoul;Yoon, Sung Hoon;Hong, Sung Hwa;Moon, Il Joon
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.91-98
    • /
    • 2020
  • Background and Objectives: This study aimed to compare functional hearing with the use of a personal sound amplification product (PSAP) or a basic hearing aid (HA) among sensorineural hearing impaired listeners. Subjects and Methods: Nineteen participants with mild-to-moderate sensorineural hearing loss (SNHL) (26-55 dB HL; pure-tone average, 0.5-4 kHz) were prospectively included. No participants had prior experience with HAs or PSAPs. Audiograms, speech intelligibility in both quiet and noisy environments, speech quality, and preference were assessed in three different listening conditions: unaided, with the HA, and with the PSAP. Results: The use of PSAP was associated with significant improvement in pure-tone thresholds at 1, 2, and 4 kHz compared to the unaided condition (all p<0.01). In the quiet environment, speech intelligibility was significantly improved after wearing a PSAP compared to the unaided condition (p<0.001), and this improvement was better than the result obtained with the HA. The PSAP also demonstrated similar improvement in the most comfortable levels compared to those obtained with the HA (p<0.05). However, there was no significant improvement of speech intelligibility in a noisy environment when wearing the PSAP (p=0.160). There was no significant difference in the reported speech quality produced by either device or in participant preference for the PSAP or HA. Conclusions: The current result suggests that PSAPs provide considerable benefits to speech intelligibility in a quiet environment and can be a good alternative to compensate for mild-to-moderate SNHL.

A Study on the Gamut Mapping Method of the Wide Gamut Display Device (광 색역 디스플레이 장치의 색역 사상에 관한 연구)

  • Um Jinsub;Shin Yoonchol;Kim Moonchol
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.69-80
    • /
    • 2005
  • In these days, the technology development of the imaging/optic industry and the digital broadcasting replace the classic CRT with the new display devices that is getting slimmer and larger. Especially, when the general TV signal is applied directly to the wide gamut display using LED or laser, which can display higher chromatic colors that can't be reproduced on CRT, the color distortion occurs and it causes serious problems. Thus, in this paper the gamut mapping is studied, which gets rids of the color distortion and utilizes the wider color gamut than that of the CRT sufficiently. In the gamut mapping the general mapping concept is the increasement of the chroma on the same hue plane but it causes the over chromatic enhancement. So, the vector mapping, which increases the lightness md the chroma at the same time, is proposed to prevent the side effect. In the vector mapping the chromaticity is maintained constantly, hence the image can be seen more natural than that of the chroma mapping. By using the gamut fitting, it is compensated that the tone disappearance or the contour effect that is arose from the geometric properties of the input and the output color gamut. These gamut mapping and gamut fitting can prevent the color distortion and reproduce the natural image on the wide gamut displays.

Progress In Commercialization Of Light Emitting Polymers: Dow Polyfluorenes

  • Wu, W.;Inbasekaran, M.;Hudack, M.;Welsh, D.;Yu, W.;Chen, Y.;Wang, C.;Kram, S.;Tacey, M.;Bernius, M.;Fletcher, R.;Kiszka, K.;Munger, S.;O'Brien, J.;Hills, M.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.340-343
    • /
    • 2002
  • We report here our recent progress in the development and commercialization of polyfluorenes emitting red, green and blue (ROB) colors as materials for light emitting diodes (LEDs). Our patented version of the Suzuki coupling process has been used to synthesize a variety of fluorenebased homopolymers and copolymers emitting colors across the entire visible spectrum. The optical and electronic properties of the polymers are tailored through selective incorporation of different aromatic units into the polyfluorene backbone. Our latest green emitter, reported herein, provides very efficient devices with a low turn-on voltage of 2.25 V, a peak efficiency of 10.5 Cd/A at 6,600 Cd/$m^2$ at 4.85 V. These devices maintain an efficiency of greater than 10 Cd/A up to 50,000 Cd/$m^2$ and demonstrate very good stability as exemplified by a device half-life of greater than 1,500 hours starting from 1,100 Cd/$m^2$. Considerable progress has also been made with red and blue emitters and will be the subject of this presentation.

  • PDF