• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.032 seconds

Graphene Oxide/Polyimide Nanocomposites for Gas Barrier Applications (산화그래핀이 함유된 폴리이미드 나노복합막의 기체차단성 평가 및 활용)

  • Yoo, Byung Min;Lee, Min Yong;Park, Ho Bum
    • Membrane Journal
    • /
    • v.27 no.2
    • /
    • pp.154-166
    • /
    • 2017
  • Polymeric films for gas barrier applications such as food packaging and electronic devices have attracted great interest due to their cheap, light and easy processability among gas barrier materials. Especially in electronic devices, extremely low gas permeance is necessary for maintaining the device performance. However, current polymeric barrier films still suffer from relatively high gas permeance than other materials. Therefore, there have been strong needs to enhance the gas barrier performance of polymeric barrier films while keep their own advantages. Recently, graphene is highlighted as a 2D-layered material for gas barrier applications. However, owing to the poor workability and difficulty to produce in engineering scale, graphene oxide (GO) is on the rise. GO consists of oxygen-containing functional groups on surface with intrinsic 2D-layered structure and high aspect ratio, and it can be well-dispersed in aqueous polar solvents like water, resulting in scalable mass production. Here, we prepared GO incorporated polyimide (PI) nanocomposites. PI is widely used barrier polymer with high mechanical strength and thermal and chemical stability. We demonstrated that PI/GO nanocomposites could perform as a gas barrier. Furthermore, surfactants (Triton X-100 (TX) and Sodium deoxycholate (SDC)) are introduced to enhance the gas barrier performance by improving the degree of dispersion of GO in PI matrix. As a result, TX enhanced the gas barrier performance of PI/GO nanocomposites which is similar to predicted value. This finding will provide new insight to polymer nanocomposites for gas barrier applications.

Volatile Organic Compounds(VOCs) Sensing Properties of Thin Films Based on Copper phthalocyanine and Dilithium phthalocyanine Compounds (Copper phthalocyanine과 Dilithium phthalocyanine 화합물 박막의 휘발성 유기화합물(VOCs) 센서 특성)

  • Kim, Dong Hyun;Kang, Young Goo;Kang, Young Jin
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.37-41
    • /
    • 2013
  • In this work, we report the effect on the volatole organic compounds(VOCs) sensing properties of Copper phthalocyanine(CoPc) and Dilithium phthalocyanine(DiLiPc) thin films onto alumina substrates. Use evaporation method and the spin-coated method for sensing device. The materials of metallophthalocyanine macrocyclic compound solutions blended with N,N'-diphenyl-N,N'-bis(1-naphthyl)-1,1'-biphenyl-4,4"-diamine and/or Poly[2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenylenevinylene] solutions. The influence of the blended in with metallophthalocyanine macrocyclic compounds on the resistance have been measured and analyzed in five different volatole organic compounds. The following results were obtained: The AFM 3D image of thin films deposited on metallophthalocyanine macrocyclic compound shows that the surfaces roughness were about CuPc 4.1~14.3 nm(7.5~8.1%), DiLiPc 10.3~22.2 nm(7.9~11.5%). The resistances decreases upon increasing the concentration of vapor organic compounds to CuPc and DiLiPc thin films. That thin films blended Copper phthalocyanine(CoPc) and Dilithium phthalocyanine(DiLiPc) with N,N'-diphenyl-N,N'-bis(1-naphthyl)-1,1'-biphenyl-4,4"-diamine and/or Poly[2-methoxy--5-(2'-ethylhexyloxy)-1,4-phenylenevinylene]. The resistances of blended thin films with N,N'-diphenyl-N,N'-bis(1-naphthyl)-1,1'-biphenyl-4,4"-diamine and/or Poly[2-methoxy--5-(2'-ethylhexyloxy)-1,4-phenylenevinylene] decreases upon increasing the concentration of volatole organic compounds(VOCs) on DiLiPc than CuPc compound thin films.

Real-time Depth Image Refinement using Hierarchical Joint Bilateral Filter (계층적 결합형 양방향 필터를 이용한 실시간 깊이 영상 보정 방법)

  • Shin, Dong-Won;Hoa, Yo-Sung
    • Journal of Broadcast Engineering
    • /
    • v.19 no.2
    • /
    • pp.140-147
    • /
    • 2014
  • In this paper, we propose a method for real-time depth image refinement. In order to improve the quality of the depth map acquired from Kinect camera, we employ constant memory and texture memory which are suitable for a 2D image processing in the graphics processing unit (GPU). In addition, we applied the joint bilateral filter (JBF) in parallel to accelerate the overall execution. To enhance the quality of the depth image, we applied the JBF hierarchically using the compute unified device architecture (CUDA). Finally, we obtain the refined depth image. Experimental results showed that the proposed real-time depth image refinement algorithm improved the subjective quality of the depth image and the computational time was 260 frames per second.

Design of Supersonic Wind Tunnel for Analysis of Flow over a Backward Facing Step with Slot Injection (슬롯 분사가 있는 후향계단 유동장 분석을 위한 초음속풍동 설계)

  • Kim, Ick-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.363-367
    • /
    • 2016
  • A test section of a supersonic wind tunnel was designed for the analysis of flow characteristics over a backward-facing step with Mach 1.0 slot injection in a supersonic flow of Mach 2.5. The cavity flow of a high-speed vehicle is very complex at supersonic speed, so it is necessary to do experiments using supersonic wind tunnels to verify numerical analysis methods. The previous 2D symmetrical nozzle was replaced with an asymmetrical nozzle. The inviscid nozzle contour was designed using Method of Characteristics (MOC), and the boundary layer thickness correction was reflected by experimental data from the wind tunnel. The results were compared with a CFD analysis. The PID control system was changed to be based on the change of tank pressure. This improved the control efficiency, and the run times of supersonic flow increased by about 1 second. The flow characteristics over a backward facing step with slot injection were visualized by a Schlieren device. This equipment will be used for an experimental study of the film cooling effectiveness over a cavity with various velocities, mass flows, and temperatures.

Implementation of an Auditory Late Latency Response Measurement System for Researching Objective Tinnitus Detection Method (객관적 이명검사 연구를 위한 청성 후기 반응 측정 시스템의 구현)

  • Park, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Recently, a method for detecting animal tinnitus objectively, gap prepulse inhibition of acoustic startling (GPIAS) were reported. However, the GPIAS method is difficult to be directly applied to human tinnitus research because measuring repeatedly startling responses evoked by more than 110 dB SPL acoustic stimuli for human is not easy. In this paper, the auditory late latency response (ALLR) measurement system which can measure conveniently evoked potentials involving the information about the brain cortical activity related with auditory psychologic phenomena such as a tinnitus has been implemented. By using the implemented system, 8 persons with normal hearing sense have been experimented to measure N1-P2 amplitudes of ALLRs evoked by gap prepulse based acoustic stimuli. Through the experimental results, the prepulse inhibitions of all the participants' N1-P2 responses have been observed and their characteristics were evaluated. And it is verified that our implemented system can be utilized as a device for researching and evaluating the objective tinnitus detection method in the future study.

  • PDF

Implementation a Physical Ear Model for Determinating Location of the Microphone of Fully Implantable Middle Ear Hearing Device (완전 이식형 인공중이용 마이크로폰의 위치 결정을 위한 물리적 귀 모델의 구현)

  • Kim, D.W.;Seong, K.W.;Lim, H.K.;Kim, M.W.;Jung, E.S.;Lee, J.W.;Lee, M.W.;Lee, J.H.;Kim, M.N.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • Generally, implantable microphone has been implanted in the temporal bone for implantable middle ear hearing devices (IMEHDs). In this case, the microphone's membrane can be damaged and can be generated biological noise. In order to overcome the these problems, the location of implanted microphone should be changed. As an alternative, the microphone can be implanted in the external auditory canal. However, the sound emission can be produced because of vibration transducer toward reverse direction from the tympanic membrane to the external auditory canal. In this paper, an amount of the emitted sound is measured using a probe microphone as the changing the position of microphone in the external auditory canal of a physical ear model, which is similar to acoustical and vibratory properties of the human ear. Through the measured value, the location of the microphone was assumed in the external auditory canal. According to the analysis, the microphone input sound can be decreased when microphone position become more distance from the tympanic membrane in the auditory canal. However, the external auditory canal is not appropriated to implantable microphone position, because sound emission is not completely eliminated.

  • PDF

The Discipline of the Dom-ino Frame and the Regulating Line - A Study of Le Corbusier's Villa La Roche-Jeanneret and Villa Stein-de Monzie - (르 꼬르뷔제 건축에서 돔-이노 프레임과 규준선의 기율 - 라 로쉬-잔느레 주택과 가르쉬 주택을 중심으로 -)

  • Pai, Hyung-Min;Hyun, Myung-Seok
    • Journal of architectural history
    • /
    • v.12 no.1 s.33
    • /
    • pp.25-41
    • /
    • 2003
  • This paper is a study of Le Corbusier's trace regulateur of the 1920s, particularly its role in the design of the Villas La Roche-Jeanneret and Stein-de Monzie. It proceeds on the basis of the following three themes: first, the relation between the regulating line and the dom-ino frame; second, its status as a proportional device based not on a module system but one that defines relations; third, its function as an essential practical device in the design process. In the Villa La Roche-Jeanneret, the embedded horizontal planes of the dom-ino frame were constant, but the vortical lines of the columns were altered according to the changes in plan. Initially, a left-hand bay window formed a symmetry with the right-hand bay window, the only constant in the design process. With subsequent changes, mullion sections of the horizontal window and roof elements came to provide the reference points for the regulating line. Eventually, a regulating line different from the one that controlled the bay window and the elongated volume came to control the entrance hall of Villa La Roche, resulting in three different kinds of regulating lines in the final version. In contrast to the Villa La Roche-Jeanneret, a singular and consistent regulation line was anticipated in the earliest design stages of the Villa Stein-de Monzie. The repetition of its A:B grid and the standard $2.5m{\times}1.0m$ sliding window determined the proportions of both its plan and elevation, and thus the regulating line became 'automatic,' losing its viability as a practical tool. Though the regulating titles of the La Roche-Jeanneret look as if they were an afterthought, drawn after the design was complete, they were most active, requiring tenacity and discipline in their application. On the other hand, the seemingly 'redundant' regulating line of the Villa Stein-de Monzie gains its raison d'etre from the dom-ino frame. Its cantilevers and uninterrupted horizontal window could be used in decisive fashion because of the guarantee that the correct proportion would always be maintained. Thus we discover that Le Corbusier's discipline of the 1920s had a certain spectrum of flexibility. His 'parti' ranged from the extremely loose and malleable grid of the Villa La Roche-Jeanneret to the fixed grid of the Villa Stein-de Monzie. In different ways, these projects retain the tension between the dom-ino frame and the regulating line. For Le Corbusier, as much as the grid was an object with fixed attributes, it was also an active medium manipulated by the will of the architect.

  • PDF

A Biomechanical Analysis of an Interspinous Distraction Device for Treatment of Lumbar Spinal Stenosis (요추부 협착증 치료를 위한 극돌기 삽입술의 생체역학적 효과 분석)

  • Lee Hui-Sung;Chen Wen Ming;Song Dong-Ryul;Kwon Soon-Young;Lee Kwon-Yong;Lee Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.210-217
    • /
    • 2006
  • Many types of interspinous distraction devices (IDDs) have been recently developed as an alternative surgical treatment to laminectomy and fusion with pedicle screws for the treatment of the lumbar spinal stenosis (LSS). They are intended to keep the lumbar spine in a slightly flexed posture to relieve pain caused by narrowing of the spinal canal and vertebral foramen. However, their biomechanical efficacies are not well known. In this study, we evaluated the kinematic behaviors and changes in intradiscal pressure (IDP) of the porcine lumbar spine implanted with IDD. For kinematics analysis, five porcine lumbar spines (L2-L6) were used and the IDD was inserted at L4-L5. Three markers (${\phi}{\le}0.8mm$) were attached on each vertebra to define a rigid body motion for stereophotogrammetric assessment of the spinal motion in 3-D. A moment of 7.5Nm in flexion-extension, lateral bending, and axial rotation were imparted with a compressive force of 700N. Then, IDD was implanted at L3-L4. IDPs were measured using pressure transducer under compression (700N) and additional extension moment (700N+7.5Nm). In kinematic behaviors, insertion of IDD resulted in statistically significant decrease 42.8% at the implanted level in extension. There were considerable changes in ROM at the adjacent levels, but statistically insignificant. In other motions, there were no significant changes in ROM as well regardless of levels. IDPs at the surgical level (L3-L4) under compression and extension moment decreased by 12.9% and 18.8% respectively after surgery (p<0.05). At the superiorly adjacent levels, IDPs increased by 19.4% and 12.9% under compression and extension, respectively (p<0.05). Corresponding changes at the inferiorly adjacent levels were 29.4% and 6.9%, but they were statistically insignificant (p>0.05). The magnitude of pressure changes due to IDD, both at the operated and adjacent levels, were far less than the previously reported values with conventional fusion techniques. Our experimental results demonstrated the IDDs can be very effective in limiting the extension motion that may cause narrowing of the spinal canal and vertebral foramens while maintaining kinematic behaviors and disc pressures at the adjacent levels.

Cohort Study for the Effect of Chronic Noise Exposure on Blood Pressure among Male Workers (만성적 소음노출이 혈압에 미치는 영향에 대한 코호트연구)

  • Cha, Tae-Joon;Kim, Jang-Rak;Kang, Wee-Chang;Yaang, Seung-Rim;Lee, Choong-Ryeol;Yoo, Cheol-In;Lee, Ji-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.3
    • /
    • pp.205-213
    • /
    • 2002
  • Objective : Whether exposure to chronic noise induces an increase in blood pressure, or the development of hypertension, has not been established. A cohort study was performed to identify the effects of chronic noise exposure on blood pressure. Methods : 530 males working at a metal manufacturing factory in Busan, Korea were enrolled for the study. They were monitored for 9 consecutive years, from 1991 to 1999, with an annual health check-up. The subjects were divided into 4 groups, which were determines by noise level categories(NLC) according to noise intensity ; NLC-I: office workers, exposed to noise a level below 60dB(A) ; NLC-II: field technical supporters or supervisors, frequently exposed to workplace noise, wearing no hearing protection device; NLC-III: workers, exposed to workplace noise below 85dB(A), wearing ear plugs or muffs; NLC-IV: workers, exposed to workplace noise over 85 dB(A), wearing both ear plugs and muffs. Results : After controlling possible confoundens, such as baseline age, smoking, alcohol intake, exercise, family history of hypertension, systolic(SBP) of diastolic blood pressure(DBP) and changes in BMI (body mass index), the pooled mean for the systolic blood pressures, over the duration of the study period, were 3.8mmHg, 2.0mmHg and 1.7mmHg higher in NLC-IV, NLC-III NLC-II groups, respectively, than in the NLC-I group. There were no significant differences in the diastolic blood pressures between the groups. Conclusion : This study suggests that chronic noise exposure increases systolic blood pressure independently, among male workers.

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.