• Title/Summary/Keyword: Device performance

Search Result 5,965, Processing Time 0.042 seconds

Development of algorithm for work intensity evaluation using excess overwork index of construction workers with real-time heart rate measurement device

  • Jae-young Park;Jung Hwan Lee;Mo-Yeol Kang;Tae-Won Jang;Hyoung-Ryoul Kim;Se-Yeong Kim;Jongin Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.24.1-24.15
    • /
    • 2023
  • Background: The construction workers are vulnerable to fatigue due to high physical workload. This study aimed to investigate the relationship between overwork and heart rate in construction workers and propose a scheme to prevent overwork in advance. Methods: We measured the heart rates of construction workers at a construction site of a residential and commercial complex in Seoul from August to October 2021 and develop an index that monitors overwork in real-time. A total of 66 Korean workers participated in the study, wearing real-time heart rate monitoring equipment. The relative heart rate (RHR) was calculated using the minimum and maximum heart rates, and the maximum acceptable working time (MAWT) was estimated using RHR to calculate the workload. The overwork index (OI) was defined as the cumulative workload evaluated with the MAWT. An appropriate scenario line (PSL) was set as an index that can be compared to the OI to evaluate the degree of overwork in real-time. The excess overwork index (EOI) was evaluated in real-time during work performance using the difference between the OI and the PSL. The EOI value was used to perform receiver operating characteristic (ROC) curve analysis to find the optimal cut-off value for classification of overwork state. Results: Of the 60 participants analyzed, 28 (46.7%) were classified as the overwork group based on their RHR. ROC curve analysis showed that the EOI was a good predictor of overwork, with an area under the curve of 0.824. The optimal cut-off values ranged from 21.8% to 24.0% depending on the method used to determine the cut-off point. Conclusion: The EOI showed promising results as a predictive tool to assess overwork in real-time using heart rate monitoring and calculation through MAWT. Further research is needed to assess physical workload accurately and determine cut-off values across industries.

Enhanced Crystallinity of Piezoelectric Polymer via Flash Lamp Annealing (플래시광 열처리를 통한 압전 고분자의 결정성 향상 연구)

  • Donghun Lee;Seongmin Jeong;Hak Su Jang;Dongju Ha;Dong Yeol Hyeon;Yu Mi Woo;Changyeon Baek;Min-Ku Lee;Gyoung-Ja Lee;Jung Hwan Park;Kwi-Il Park
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.4
    • /
    • pp.427-432
    • /
    • 2024
  • The polymer crystallization process, promoting the formation of ferroelectric β-phase, is essential for developing polyvinylidene fluoride (PVDF)-based high-performance piezoelectric energy harvesters. However, traditional high-temperature annealing is unsuitable for the manufacture of flexible piezoelectric devices due to the thermal damage to plastic components that occurs during the long processing times. In this study, we investigated the feasibility of introducing a flash lamp annealing that can rapidly induce the β-phase in the PVDF layer while avoiding device damage through selective heating. The flash light-irradiated PVDF films achieved a maximum β-phase content of 76.52% under an applied voltage of 300 V and an on-time of 1.5 ms, a higher fraction than that obtained through thermal annealing. The PVDF-based piezoelectric energy harvester with the optimized irradiation condition generates a stable output voltage of 0.23 V and a current of 102 nA under repeated bendings. These results demonstrate that flash lamp annealing can be an effective process for realizing the mass production of PVDF-based flexible electronics.

A Study of Static Random Access Memory Single Event Effect (SRAM SEE) Test using 100 MeV Proton Accelerator (100 MeV 양성자가속기를 활용한 SRAM SEE(Static Random Access Memory Single Event Effect) 시험 연구)

  • Wooje Han;Eunhye Choi;Kyunghee Kim;Seong-Keun Jeong
    • Journal of Space Technology and Applications
    • /
    • v.3 no.4
    • /
    • pp.333-341
    • /
    • 2023
  • This study aims to develop technology for testing and verifying the space radiation environment of miniature space components using the facilities of the domestic 100 MeV proton accelerator and the Space Component Test Facility at the Space Testing Center. As advancements in space development progress, high-performance satellites increasingly rely on densely integrated circuits, particularly in core components components like memory. The application of semiconductor components in essential devices such as solar panels, optical sensors, and opto-electronics is also on the rise. To apply these technologies in space, it is imperative to undergo space environment testing, with the most critical aspect being the evaluation and testing of space components in high-energy radiation environments. Therefore, the Space Testing Center at the Korea testing laboratory has developed a radiation testing device for memory components and conducted radiation impact assessment tests using it. The investigation was carried out using 100 MeV protons at a low flux level achievable at the Gyeongju Proton Accelerator. Through these tests, single event upsets observed in memory semiconductor components were confirmed.

Preparation of Vinyl Waste-derived Separator and Enhancement of Electrochemical Performance using Electrospinning and Plasma Treatment (전기방사와 산소 플라즈마 처리를 활용한 폐비닐 기반의 분리막 합성 및 전기화학적 성능 향상 연구)

  • Chan-Gyo Kim;Yoon-Ho Ra;Suk Jekal;Chang-Min Yoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.1
    • /
    • pp.31-38
    • /
    • 2024
  • In this study, vinyl waste, which is the cause of environmental pollution, is recycled via an electrospinning method and applied as a separator that can be employed for energy storage devices. In detail, vinyl wastes are dissolved in a solution containing p-xylene and cyclohexanone, followed by electrospinning to obtain a vinyl waste-derived separator(VWS), and then the hydrophilic functional groups on the surface of VWS are introduced using a plasma treatment to improve wettability. Scanning electron microscopy analysis have verified that the shape and thickness of as-spun VWS vary depending on the concentration of vinyl waste. The surface hydrophility of VWS is modified by plasma treatment with applied powers ranging from 80 to 120W. The lowest contact angle is observed when the 100W power is applied to VWS(VWS-100W). In electrochemical analysis, the VWS-100W-based supercapacitor device shows the highest specific capacitance of 57.9 F g-1. This is ascribed to the high porosity achieved by electrospinning as well as the introduction of hydrophilic functional groups by the oxygen plasma treatment. In conclusion, vinyl waste is successfully recycled into separators for energy storage devices, suggesting a new way to reduce environmental pollution.

Analytical Evaluation of PPG Blood Glucose Monitoring System - researcher clinical trial (PPG 혈당 모니터링 시스템의 분석적 평가 - 연구자 임상)

  • Cheol-Gu Park;Sang-Ki Choi;Seong-Geun Jo;Kwon-Min Kim
    • Journal of Digital Convergence
    • /
    • v.21 no.3
    • /
    • pp.33-39
    • /
    • 2023
  • This study is a performance evaluation of a blood sugar monitoring system that combines a PPG sensor, which is an evaluation device for blood glucose monitoring, and a DNN algorithm when monitoring capillary blood glucose. The study is a researcher-led clinical trial conducted on participants from September 2023 to November 2023. PPG-BGMS compared predicted blood sugar levels for evaluation using 1-minute heart rate and heart rate variability information and the DNN prediction algorithm with capillary blood glucose levels measured with a blood glucose meter of the standard personal blood sugar management system. Of the 100 participants, 50 had type 2 diabetes (T2DM), and the average age was 67 years (range, 28 to 89 years). It was found that 100% of the predicted blood sugar level of PPG-BGMS was distributed in the A+B area of the Clarke error grid and Parker(Consensus) error grid. The MARD value of PPG-BGMS predicted blood glucose is 5.3 ± 4.0%. Consequentially, the non-blood-based PPG-BGMS was found to be non-inferior to the instantaneous blood sugar level of the clinical standard blood-based personal blood glucose measurement system.

Real-World Application of Artificial Intelligence for Detecting Pathologic Gastric Atypia and Neoplastic Lesions

  • Young Hoon Chang;Cheol Min Shin;Hae Dong Lee;Jinbae Park;Jiwoon Jeon;Soo-Jeong Cho;Seung Joo Kang;Jae-Yong Chung;Yu Kyung Jun;Yonghoon Choi;Hyuk Yoon;Young Soo Park;Nayoung Kim;Dong Ho Lee
    • Journal of Gastric Cancer
    • /
    • v.24 no.3
    • /
    • pp.327-340
    • /
    • 2024
  • Purpose: Results of initial endoscopic biopsy of gastric lesions often differ from those of the final pathological diagnosis. We evaluated whether an artificial intelligence-based gastric lesion detection and diagnostic system, ENdoscopy as AI-powered Device Computer Aided Diagnosis for Gastroscopy (ENAD CAD-G), could reduce this discrepancy. Materials and Methods: We retrospectively collected 24,948 endoscopic images of early gastric cancers (EGCs), dysplasia, and benign lesions from 9,892 patients who underwent esophagogastroduodenoscopy between 2011 and 2021. The diagnostic performance of ENAD CAD-G was evaluated using the following real-world datasets: patients referred from community clinics with initial biopsy results of atypia (n=154), participants who underwent endoscopic resection for neoplasms (Internal video set, n=140), and participants who underwent endoscopy for screening or suspicion of gastric neoplasm referred from community clinics (External video set, n=296). Results: ENAD CAD-G classified the referred gastric lesions of atypia into EGC (accuracy, 82.47%; 95% confidence interval [CI], 76.46%-88.47%), dysplasia (88.31%; 83.24%-93.39%), and benign lesions (83.12%; 77.20%-89.03%). In the Internal video set, ENAD CAD-G identified dysplasia and EGC with diagnostic accuracies of 88.57% (95% CI, 83.30%-93.84%) and 91.43% (86.79%-96.07%), respectively, compared with an accuracy of 60.71% (52.62%-68.80%) for the initial biopsy results (P<0.001). In the External video set, ENAD CAD-G classified EGC, dysplasia, and benign lesions with diagnostic accuracies of 87.50% (83.73%-91.27%), 90.54% (87.21%-93.87%), and 88.85% (85.27%-92.44%), respectively. Conclusions: ENAD CAD-G is superior to initial biopsy for the detection and diagnosis of gastric lesions that require endoscopic resection. ENAD CAD-G can assist community endoscopists in identifying gastric lesions that require endoscopic resection.

Relationship Between Amyloid Positivity and Sleep Characteristics in the Elderly With Subjective Cognitive Decline

  • Kyung Joon Jo;SeongHee Ho;Yun Jeong Hong;Jee Hyang Jeong;SangYun Kim;Min Jeong Wang;Seong Hye Choi;SeungHyun Han;Dong Won Yang;Kee Hyung Park
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.1
    • /
    • pp.22-29
    • /
    • 2024
  • Background and Purpose: Alzheimer's disease (AD) is a neurodegenerative disease characterized by a progressive decline in cognition and performance of daily activities. Recent studies have attempted to establish the relationship between AD and sleep. It is believed that patients with AD pathology show altered sleep characteristics years before clinical symptoms appear. This study evaluated the differences in sleep characteristics between cognitively asymptomatic patients with and without some amyloid burden. Methods: Sleep characteristics of 76 subjects aged 60 years or older who were diagnosed with subjective cognitive decline (SCD) but not mild cognitive impairment (MCI) or AD were measured using Fitbit® Alta HR, a wristwatch-shaped wearable device. Amyloid deposition was evaluated using brain amyloid plaque load (BAPL) and global standardized uptake value ratio (SUVR) from fluorine-18 florbetaben positron emission tomography. Each component of measured sleep characteristics was analyzed for statistically significant differences between the amyloid-positive group and the amyloid-negative group. Results: Of the 76 subjects included in this study, 49 (64.5%) were female. The average age of the subjects was 70.72±6.09 years when the study started. 15 subjects were classified as amyloid-positive based on BAPL. The average global SUVR was 1.598±0.263 in the amyloid-positive group and 1.187±0.100 in the amyloid-negative group. Time spent in slow-wave sleep (SWS) was significantly lower in the amyloid-positive group (39.4±13.1 minutes) than in the amyloid-negative group (49.5±13.1 minutes) (p=0.009). Conclusions: This study showed that SWS is different between the elderly SCD population with and without amyloid positivity. How SWS affects AD pathology requires further research.

2023 Survey on User Experience of Artificial Intelligence Software in Radiology by the Korean Society of Radiology

  • Eui Jin Hwang;Ji Eun Park;Kyoung Doo Song;Dong Hyun Yang;Kyung Won Kim;June-Goo Lee;Jung Hyun Yoon;Kyunghwa Han;Dong Hyun Kim;Hwiyoung Kim;Chang Min Park;Radiology Imaging Network of Korea for Clinical Research (RINK-CR)
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.613-622
    • /
    • 2024
  • Objective: In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known about the current usage, implementation, and future needs of AI-SaMDs. We surveyed the current trends and expectations for AI-SaMDs among members of the Korean Society of Radiology (KSR). Materials and Methods: An anonymous and voluntary online survey was open to all KSR members between April 17 and May 15, 2023. The survey was focused on the experiences of using AI-SaMDs, patterns of usage, levels of satisfaction, and expectations regarding the use of AI-SaMDs, including the roles of the industry, government, and KSR regarding the clinical use of AI-SaMDs. Results: Among the 370 respondents (response rate: 7.7% [370/4792]; 340 board-certified radiologists; 210 from academic institutions), 60.3% (223/370) had experience using AI-SaMDs. The two most common use-case of AI-SaMDs among the respondents were lesion detection (82.1%, 183/223), lesion diagnosis/classification (55.2%, 123/223), with the target imaging modalities being plain radiography (62.3%, 139/223), CT (42.6%, 95/223), mammography (29.1%, 65/223), and MRI (28.7%, 64/223). Most users were satisfied with AI-SaMDs (67.6% [115/170, for improvement of patient management] to 85.1% [189/222, for performance]). Regarding the expansion of clinical applications, most respondents expressed a preference for AI-SaMDs to assist in detection/diagnosis (77.0%, 285/370) and to perform automated measurement/quantification (63.5%, 235/370). Most respondents indicated that future development of AI-SaMDs should focus on improving practice efficiency (81.9%, 303/370) and quality (71.4%, 264/370). Overall, 91.9% of the respondents (340/370) agreed that there is a need for education or guidelines driven by the KSR regarding the use of AI-SaMDs. Conclusion: The penetration rate of AI-SaMDs in clinical practice and the corresponding satisfaction levels were high among members of the KSR. Most AI-SaMDs have been used for lesion detection, diagnosis, and classification. Most respondents requested KSR-driven education or guidelines on the use of AI-SaMDs.

NORMOBARIC OXYGEN($O_2$) ADMINISTRATION EFFECT ON ATTENTION AND MEMORY FUNCTION IN TEENAGE ADOLESCENTS (10대 청소년의 주의력과 기억능력에 미치는 정상기압 산소흡입 효과)

  • Kim, Byung-Hyo;Kim, Young-Mi;Cho, Soo-Churl;Kim, Boong-Nyun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.13 no.1
    • /
    • pp.76-84
    • /
    • 2002
  • Objectives:This study was conducted to investigate the effect of oxygen on attention and memory functions in healthy adolescents. Methods:The participant subjects were recruited from local advertisement. All subjects are students attending ordinary middle and high school. Their degree of achievement was average or below average. Before the study, its nature and purpose were fully explained to the patients and their parents, and a written informed consent was obtained from each child's parent and a written assent from each child for entire the procedure. The Ethics Committee and Clinical Research Committee of Gyeongsang National University Hospital approved the protocol. For baseline assessment, all subjects received tests for attention and memory. All tests were conducted by a certified psychologist. Stroop test, continuous performance test and trail making test A and B were used for evaluation of attention. As memory tests, we used memory assessment scale(MAS), standardized memory assessment tools. Ten to fourteen days after initial assessments, same tests was applied to the same subjects after prior 5 minute oxygen inhalation. Results:1) Attention test:Improved performances in trail making part B, and stroop test were found in normobaric oxygen inhalation group compared to air inhalation group. Improved reaction time in those tests seemed to reflect the enhanced executive prefrontal activity. 2) Memory test:More words and digits memorization were found in short-term memory subscale score in MAS in oxygen inhalation group compared to air inhalation group. This finding suggested the improved working memory function after oxygen inhalation. Conclusion:Though interpreted cautiously, these results suggested that normobaric oxygen inhalation could enhance executive function and working memory of prefrontal lobe. Further study, however, should be performed to investigate the mechanism of effects of oxygen on cognitive enhancement.

  • PDF

A Study on the Utilization of Information and Communication Assistive Devices for Bridging the Digital Divide of the Disabled (장애인 정보격차 해소를 위한 정보통신 보조기기 활용방안 연구)

  • Kim, Jung-Ho;Suh, Jun-Kyo Francis;Koo, Jun
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.581-596
    • /
    • 2010
  • The purposes of this study are to investigate and analyze the level of information and the state of digital divide of the disabled by surveying the demand for information and communication assistive devices, and to provide basic data for plans on the development and utilization of information and communication assistive devices. In order to understand the actual condition and the state of digital divide of persons with disabilities, the differences of possession and accessibility of information technology devices, usage ability, and utilization were analyzed according to the disability profile by using the T-test. The results show that there are significant differences (T=-2.510*) of possession and accessibility of information technology devices with respect to the disability profile, and that the disabled have lower possession and accessibility of devices than the non-disabled. Result of this study's demand forecast shows that about 28% of total respondents are currently using information and communication assistive devices, and a majority (67%) of them answered that the use of assistive devices lend great help to their lives. The proportion of those who have been supported by the government or related organizations with information and communication assistive devices were 36% of the total respondents, and those satisfied with the performance of the devices were 46% of the total responses. Meanwhile, only 36% of total users answered that the operation and use of functions of the devices was easy and convenient, responding that the difficulty of operating assistive devices was the greatest inconvenience. Moreover, the general requests of respondents in regards to the devices were stabilization of device performance, miniaturization of size, simplification of buttons, and reduction of weight.

  • PDF