• Title/Summary/Keyword: Device performance

Search Result 5,979, Processing Time 0.032 seconds

Development and Evaluation of an Indirect Illumination for Tongue Image Acquisition (설 영상 획득을 위한 간접 조명 구현 및 평가)

  • Jung, Chang Jin;Kim, Keun Ho;Jang, Jun-Su;Jeon, Young Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.221-228
    • /
    • 2014
  • The color and shape of the tongue reflect the physiological and clinico-pathological condition of the body. Recently, various tongue image acquisition devices have been developed for accurate diagnosis based on quantitative and objective tongue features. Since a color information is essential for tongue diagnosis, the performance of an illuminator is very important for the tongue image acquisition device. In this study, we developed an indirect illumination, which is possible to improve a homogeneity of light intensities on the tongue surface, and evaluated its performances. In order to realize the indirect illumination (II), a semi-ellipsoidal solid structure (SESS) for the light reflex was located in the system, and two high-brightness white LEDs were placed for illuminating the areas under frontal camera in the SESS. The tongue surface was illuminated by reflected light from the SESS. The light homogeneity induced by three different illuminations including the II was evaluated by calculating coefficient of variation (CV) of illuminance of five regions. The II showed less than 0.01 of CV and the direct illumination (DI) and the direct illumination with a light diffusion plate (DILDP) showed 0.16 and 0.13, respectively. The reflexed pixel ratios of tongue phantom images show 5.76%, 4.22%, 1.79% for the DI, the DILDP and the II, respectively. The homogeneity of a tongue phantom was evaluated by calculating CV of mean pixel values of six different tongue regions, and showed less than 0.06 in the II. If the II technique apply to tongue diagnosis system, it is expected to improve diagnostic accuracy in clinic.

3-Dimensional LADAR Optical Detector Development in Geiger Mode Operation (Geiger Mode로 동작하는 3차원 LADAR 광수신기 개발)

  • Choi, Soon-Gyu;Shin, Jung-Hwan;Kang, Sang-Gu;Hong, Jung-Ho;Kwon, Yong-Joon;Kang, Eung-Cheol;Lee, Chang-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.4
    • /
    • pp.176-183
    • /
    • 2013
  • In this paper, we report the design, fabrication and characterization of the 3-Dimensional optical receiver for a Laser Detection And Ranging (LADAR) system. The optical receiver is composed of three parts; $16{\pm}16$ Geiger Mode InGaAs Avalanche Photodiode (APD) array device operated at 1560 nm wavelength, Read Out Integrated Circuit (ROIC) measuring the Time-Of-Flight (TOF) of the return signal reflected from target objects, a package and cooler maintaining the proper operational condition of the detector and control electronics. We can confirm that the LADAR system can detect the signal from a target up to 1.2 km away, and it showed low Dark Count Rate (DCR) of less than 140 kHz, and higher than 28%-Photon Detection Efficiency (PDE). This is considered to be the best performance of the $16{\pm}16$ FPA APD optical receiver for a LADAR system.

The Cell Resequencing Buffer for the Cell Sequence Integrity Guarantee for the Cyclic Banyan Network (사이클릭 벤얀 망의 셀 순서 무결성 보장을 위한 셀 재배열 버퍼)

  • 박재현
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.9
    • /
    • pp.73-80
    • /
    • 2004
  • In this paper, we present the cell resequencing buffer to solve the cell sequence integrity problem of the Cyclic banyan network that is a high-performance fault-tolerant cell switch. By offering multiple paths between input ports and output ports, using the deflection self-routing, the Cyclic banyan switch offer high reliability, and it also solves congestion problem for the internal links of the switch. By the way, these multiple paths can be different lengths for each other. Therefore, the cells departing from an identical source port and arriving at an identical destination port can reach to the output port as the order that is different from the order arriving at input port. The proposed cell resequencing buffer is a hardware sliding window mechanism. to solve such cell sequence integrity problem. To calculate the size of sliding window that cause the prime cost of the presented device, we analyzed the distribution of the cell delay through the simulation analyses under traffic load that have a nonuniform address distribution that express tile Property of traffic of the Internet. Through these analyses, we found out that we can make a cell resequencing buffer by which the cell sequence integrity is to be secured, by using a, few of ordinary memory and control logic. The cell resequencing buffer presented in this paper can be used for other multiple paths switching networks.

Estimation of Mass Size Distribution of Atmospheric Aerosols Using Real-Time Aerosol Measuring Instruments (실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정)

  • Ji, Jun-Ho;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.39-50
    • /
    • 2013
  • Real-time aerosol measuring instruments have been widely used for the measurement of atmospheric aerosol, diesel particulate matter, or material synthesis. A scanning mobility particle sizer (SMPS) measures the number size distribution of particles using electrical mobility detection technique. An aerodynamic particle sizer (APS) is used to determine the number concentration and the mean aerodynamic diameter of test particles. An electrical low-pressure impactor (ELPI) is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. In this study, the performance of these instruments were evaluated to assess their ability to obtain mass concentrations from particle number concentration measurements made as a function of particle size. The effect of determination of particle density on the measurement of mass concentration was investigated for the three instruments.

A study on the monitoring of high-density fine particulate matters using W-station: Case of Jeju island (W-Station을 활용한 고밀도 초미세먼지 모니터링 연구: 제주도 사례)

  • Lee, Jong-Won;Park, Moon-Soo;Won, Wan-Sik;Son, Seok-Woo
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.31-47
    • /
    • 2020
  • Although interest in air quality has increased due to the frequent occurrence of high-concentration fine particulate matter recently, the official fine particulate matter measuring network has failed to provide spatial detailed air quality information. This is because current measurement equipment has a high cost of installation and maintenance, which limits the composition of the measuring network at high resolution. To compensate for the limitations of the current official measuring network, this study constructed a spatial high density measuring network using the fine particulate matter simple measuring device developed by Observer, W-Station. W-Station installed 48 units on Jeju Island and measured PM2.5 for six months. The data collected in W-Station were corrected by applying the first regression equation for each section, and these measurements were compared and analyzed based on the official measurements installed in Jeju Island. As a result, the time series of PM2.5 concentrations measured in W-Station showed concentration characteristics similar to those of the environmental pollution measuring network. In particular, the results of comparing the measurements of W-Station within a 2 km radius of the reference station and the reference station showed that the coefficient of determination (R2) was 0.79, 0.81, 0.67, respectively. In addition, for W-Station within a 1 km radius, the coefficient of determination was 0.85, 0.82, 0.68, respectively, showing slightly higher correlation. In addition, the local concentration deviation of some regions could be confirmed through 48 high density measuring networks. These results show that if a network of measurements is constructed with adequate spatial distribution using a number of simple meters with a certain degree of proven performance, the measurements are effective in monitoring local air quality and can be fully utilized to supplement or replace formal measurements.

Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

  • Li, Yuquan;Hao, Botao;Zhong, Jia;Wang, Nan
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.54-70
    • /
    • 2017
  • The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility-the advanced core-cooling mechanism experiment (ACME)-was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups-a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break-were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative effects on the passive core cooling performance caused by nitrogen injection during the SBLOCA transient.

The wastewater treatment system with high performance based on electrochemical interface reaction using dimensionally stable anode with simple manufacturing (전기화학 계면반응에 기초한 DSA 전극을 사용한 고성능 폐수처리 시스템)

  • Na, Young Soo;Lee, Man Sung;Kim, Kyoungho
    • Journal of Adhesion and Interface
    • /
    • v.19 no.3
    • /
    • pp.101-105
    • /
    • 2018
  • With the rapidly growing of the population and industrization of cities, the clean and affordable water resources have gained immense interest because of remaining about 780 million people still lack access to it. However, present wastewater treatment systems have been faced with various issues, such as low processing efficiency, high operational costs and the requirement of a large area for manufacturing. It is therefore urgently required to develop an inexpensive and efficient wastewater treatment system. As the one of these efforts, we suggested and successfully demonstrated the wastewater treatment system using and electrochemical method via a dimensionally stable anode (DSA) based on rutile type $RuO_2$. Our system achieved biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total organic carbon (TOC) removal efficiently at the respective rates of 52.0%, 77.8%, and 65.6% from household wastewater. In addition, we were able to remove BOD, COD, total nitrogen (TN), and total phosphorus (TP) from animal husbandry wastewater at rates of 92.9%, 75.6%, 35.1%, and 100%, respectively, thereby achieving dramatic reductions. Considering the excellent removal efficiency and the small size of this device, electrochemical wastewater treatment using a DSA coated in rutile $RuO_2$ presents a promising option for the treatment of both household and animal husbandry wastewater.

A Study of Structural Analysis Simulation for Squat Exercise Foot Plate (스쿼트운동장치의 풋플레이트 구조해석에 관한 연구)

  • Jung, Byung-Geun;Kim, Ji-won;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.365-372
    • /
    • 2017
  • Squat exercise is one of the important free weight exercises that can safely and effectively expect the athletic performance by establishing the rationale. Therefore, it is necessary to study the side effects caused by incorrect exercise, scientific countermeasures and to develop a exercise estimation model. It is effective and accurate to use a variety of assistive devices to calibrate athletic posture. The issues of the structural analysis for designing a foot plate for squat exercise is to model the behavior by the dynamic behavior. It should be consider that the center of gravity of each segmented body is different when the maximum load is applied. It is applied to complete system design through simulation method with kinematic dynamic, ground reaction force and load analysis for the free weight exercise equipment, VR device, and safety foot plate. In this paper, the authors propose the design method for the vertical load distribution applied in the design of the foot plate used for the squat exercise mechanism, and based on these results, design make the more safe and reliable free weight exercise equipment system.

IEEE 802.11-based Power-aware Location Tracking System (저전력을 고려한 IEEE 802.11 기반 위치 추적 시스템)

  • Son, Sang-Hyun;Baik, Jong-Chan;Baek, Yun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.7B
    • /
    • pp.578-585
    • /
    • 2012
  • Location tracking system through GPS and Wi-Fi is available at no additional cost in an environment of IEEE 802.11-based wireless network. It is useful for many applications in outdoor environment. However, a previous systems used for general device to tag. It is unsuitable for power aware location tracking system because general devices is more expensive and non-optimized for tracking. The hand-off method of IEEE 802.11 standard is not enough considering power consumption. This thesis analyzes the previous location tracking systems and proposes power aware system. First, we designed and implemented tag to optimize location tracking. Next, we propose low-power hand-off method and low-power behavior model in implemented tag. The proposed hand-off method resolve power problem by using the location information and behavior model minimize power consumption of tag through power-saving mode and the concept of duty cycle. To evaluating proposed methods and system performance, we perform simulations and experiments in real environment. And then, we calculate tag's power consumption based on the actual measured current consumption of each operation. In a simulation result, the proposed behavior model and hand-off method reduced about 98%, 59% than the standard's hand-off and default behavior model.

Improvement of Endoscopic Image using De-Interlacing Technique (De-Interlace 기법을 이용한 내시경 영상의 화질 개선)

  • 신동익;조민수;허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.469-476
    • /
    • 1998
  • In the case of acquisition and displaying medical Images such as ultrasonography and endoscopy on VGA monitor of PC system, image degradation of tear-drop appears through scan conversion. In this study, we compare several methods which can solve this degradation and implement the hardware system that resolves this problem in real-time with PC. It is possible to represent high quality image display and real-time processing and acquisition with specific de-interlacing device and PCI bridge on our hardware system. Image quality is improved remarkably on our hardware system. It is implemented as PC-based system, so acquiring, saving images and describing text comment on those images and PACS networking can be easily implemented.metabolism. All images were spatially normalized to MNI standard PET template and smoothed with 16mm FWHM Gaussian kernel using SPM96. Mean count in cerebral region was normalized. The VOls for 34 cerebral regions were previously defined on the standard template and 17 different counts of mirrored regions to hemispheric midline were extracted from spatially normalized images. A three-layer feed-forward error back-propagation neural network classifier with 7 input nodes and 3 output nodes was used. The network was trained to interpret metabolic patterns and produce identical diagnoses with those of expert viewers. The performance of the neural network was optimized by testing with 5~40 nodes in hidden layer. Randomly selected 40 images from each group were used to train the network and the remainders were used to test the learned network. The optimized neural network gave a maximum agreement rate of 80.3% with expert viewers. It used 20 hidden nodes and was trained for 1508 epochs. Also, neural network gave agreement rates of 75~80% with 10 or 30 nodes in hidden layer. We conclude that artificial neural network performed as well as human experts and could be potentially useful as clinical decision support tool for the localization of epileptogenic zones.

  • PDF