• 제목/요약/키워드: Device performance

검색결과 5,965건 처리시간 0.04초

반류제어장치의 선박성능요소에 미치는 영향에 대한 고찰 (Study on the Effect of Wake Control Devices on Ship Performance Components)

  • 이연승;최영복
    • 대한조선학회논문집
    • /
    • 제46권5호
    • /
    • pp.453-459
    • /
    • 2009
  • The DSME guide plate(GP) has been developed with the target to improve the cavitation and vibration performance when used with discharging cooling water around the outlet of LNG carrier. It was proven that it could as well be applied as a powerful wake control device on its own, even without discharging cooling water. However, it has to be taken into account that it inevitably results in speed loss. This study shows the possibility to design a GP which simultaneously improves both vibration and speed performance. The study intends to outline how to design the preliminary GP configurations from both the vibration and the speed performance points of view. Further, the study offers design guidance for the hull form and the propeller when adapting GP as a wake control device.

대체입력기기를 이용한 목적 있는 컴퓨터 작업 활동이 뇌성마비 환자의 수행도 만족도에 미치는 영향 (The effect of purposeful computer activity using alternative input devices on the performance and satisfaction of patients with cerebral palsy)

  • 이동건
    • 대한물리치료과학회지
    • /
    • 제27권2호
    • /
    • pp.80-87
    • /
    • 2020
  • Background: The purpose of this study was to investigate the effect of the use of an alternative input device on the patient's work performance and satisfaction in patients with cerebral palsy who cannot use computers. Design: Case Series Description. Methods: The participant was one adult cerebral palsy. The three tasks were applied with an alternative input device (Quick-Glance), 1 session an hour, 3 times a week, a total of 12 times for 4 weeks. The assessment was using the Canadian Occupational Performance Measure (COPM). The evaluation was performed pre-test before the intervention, post-test after the last intervention, and follow-up after one month. Results: The COPM(Satisfaction and performance scores) showed 3 points for pre-test, 7 points for post-test, and 7 points for follow-up. Conclusion: Purposeful computer work activity, which is an alternative input device, has a positive effect on work performance and satisfaction of cerebral palsy patients who are difficult to use computer.

Review of progress in electromechanical properties of REBCO coated conductors for electric device applications

  • Shin, Hyung-Seop;Dedicatoria, Marlon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권4호
    • /
    • pp.7-16
    • /
    • 2014
  • Rare-earth barium copper oxide (REBCO) coated conductor (CC) tapes have already been commercialized but still possess some issues in terms of manufacturing cost, anisotropic in-field performance, $I_c$ response to mechanical loads such as delamination, homogeneity of current transport property, and production length. Development on improving its performance properties to meet the needs in practical device applications is underway and simplification of the tape's architecture and manufacturing process are also being considered to enhance the performance-cost ratio. As compared to low temperature superconductors (LTS), high temperature superconductor (HTS) REBCO CC tapes provide a much wider range of operating temperature and a higher critical current density at 4.2 K making it more attractive in magnet and coil applications. The superior properties of the REBCO CC tapes under magnetic field have led to the development of superconducting magnets capable of producing field way above 23.5 T. In order to achieve its optimum performance, the electromechanical properties under different deformation modes and magnetic field should be evaluated for practical device design. This paper gives an overview of the effects of mechanical stress/strain on $I_c$ in HTS CC tapes due to uniaxial tension, bending deformation, transverse load, and including the electrical performance of a CC tape joint which were performed by our group at ANU in the last decade.

가변 사판식 압축기의 탑 클리어런스 측정 방법 및 신뢰성 확보에 관한 연구 (Study on the Measuring Method and Reliability of Top Clearance of Variable Swashplate Type Compressor)

  • 김영신;나승규
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.89-94
    • /
    • 2016
  • In this experimental study, the effects of top clearance on the performance of automotive a/c compressor were studied. Top clearance measuring device was also developed to ensure the reliability using vacuum conditions to secure constant control of top clearance without external environmental influence. Our results revealed that the improvements in compressor performance according to different top clearance values using the same compressor and same operator were about 4.12% at 800 rpm and about 7.8% at 2,000 rpm in 0.243~0.252 mm of top clearance compared to 0.431~0.456 mm of top clearance. To confirm the consistency in measuring top clearance affecting compressor performance, the top clearance measuring device was developed in this study using a vacuum pump. After performing reliable tests repeatedly, the distribution of measuring values under this device was within 0.99~1.83%, indicating that the constant test data in compressor performance was not affected by any other external environment.

다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구 (A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System)

  • 김유림;유우진;박호준;장원석
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권6호
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.

Process Parameter의 Modelling에 의한 BiCMOS 소자 설계의 최적화 방안에 관한 연구 (A Study on the Computer Modelling with Process Parameters for the Optimization of BiCMOS Device)

  • 강이구;김태익;우영신;이계훈;성만영;이철진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1460-1462
    • /
    • 1994
  • BiCMOS is the newly developed technology that integrates both CMOS and bipolar structures on the same integrated circuit. Improved performance can be obtained from combining the advantages of high density and low power in CMOS with the speed and current capibility advantages by bipolar. However, the major drawbacks to BiCMOS are high cost, long fabrication time and difficulty of merging CMOS with bipolar without degrading of device Performance because CMOS and bipolar share same process step. In this paper, N-Well CMOS oriented BiCMOS process and optimization of device performance are studied when N-Well links CMOS with bipolar process step by 2D process and 3D Device simulation. From the simulation, Constriction of linking process step has been understood and provided to give the method of choosing BiCMOS for various analog design request.

  • PDF

Intense Pulsed Light의 안전성 및 성능평가를 위한 시험 항목 및 시험방법(안) 연구 (Guideline Development to Evaluate the Safety and Performance of Intense Pulsed Light(IPL))

  • 강동연;손태윤;주예일;최응호;정병조
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권2호
    • /
    • pp.129-133
    • /
    • 2010
  • Intense pulsed light(IPL) is a photo-therapeutic medical device using xenon lamps with optical characteristics of incoherence, defocusing, and polychromatic. IPL has been recognized as a representative medical therapeutic device with growth of domestic skin care market. However, there is no standard regulation manual and guideline to evaluate the safety and performance of IPL. International Electrotechnical Commission(IEC) is being statued "Technical Report IEC TR 60825-16" which is a guidelines for the safe use of intense light source equipment on humans and animals. In this study, a standard Korea Food & Drug Administration (KFDA) regulation for the safety and performance of IPL was suggested by developing minimal evaluation methods for optical parameters of IPL such as output energy density, pulse mode, spot size, wavelength and uniformity of output light. We expect that this study may be a step to statue a standard regulation manual and guideline for IPLs used in domestic.

TRL을 이용한 R&D 프로젝트 성과 평가지표 개발: 의료기기 사업을 중심으로 (Development of Performance Measure Indices using TRL: Focused on the National Medical Device R&D Projects)

  • 이만표;정미진;최경현
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권3호
    • /
    • pp.89-94
    • /
    • 2017
  • In order to improve national competitiveness through technological research and development, the government puts in R&D budget every year and manages to improve the R&D results. Accordingly, various R&D project management methods have applied for successful advancement of technology and product. TRL is a measurement system developed by NASA to assess the maturity of technology since the 1970s. To apply medical device, the characteristics such as regulation, clinical trials are considered as a significant influence. In this study, we would like to derive PMI(performance measures index) for medical device R&D projects by using TRL and stage-gate model. As a result of this study, it is possible to use the PMI for decision making and evaluation in the R&D projects and believed that the objectivity can be ensured by the approval or certification of regulatory authority.

Performance Optimization of LDMOS Transistor with Dual Gate Oxide for Mixed-Signal Applications

  • Baek, Ki-Ju;Kim, Yeong-Seuk;Na, Kee-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.254-259
    • /
    • 2015
  • This paper reports the optimized mixed-signal performance of a high-voltage (HV) laterally double-diffused metaloxide-semiconductor (LDMOS) field-effect transistor (FET) with a dual gate oxide (DGOX). The fabricated device is based on the split-gate FET concept. In addition, the gate oxide on the source-side channel is thicker than that on the drain-side channel. The experiment results showed that the electrical characteristics are strongly dependent on the source-side channel length with a thick gate oxide. The digital and analog performances according to the source-side channel length of the DGOX LDMOS device were examined for circuit applications. The HV DGOX device with various source-side channel lengths showed reduced by maximum 37% on-resistance (RON) and 50% drain conductance (gds). Therefore, the optimized mixed-signal performance of the HV DGOX device can be obtained when the source-side channel length with a thick gate oxide is shorter than half of the channel length.