• Title/Summary/Keyword: Device closure

Search Result 77, Processing Time 0.027 seconds

Design and development of fabric-type fitness band (직물형 피트니스 밴드 디자인 및 개발)

  • Jeong, Dawun;Lee, Sojung;Kwon, Chae-Ryung;Park, Ihwa;Heo, Seowon;Kim, Dong-Eun
    • The Research Journal of the Costume Culture
    • /
    • v.26 no.4
    • /
    • pp.632-648
    • /
    • 2018
  • This study aims to contribute to the development of sports wearables. It was conducted by a convergence team of professionals in the fashion industry, kinesiology and sports studies, and computer science and engineering. The purpose of the current study was to design and develop a fabric-type fitness band for a sensor to measure acceleration during jump rope exercises. Computer science and engineering professionals developed the Arduino board and sensor, kinesiology and sports studies provided the necessary exercise protocol, and the fashion industry professionals developed the band. First, a fitness band preference survey was completed by men and women between the ages of 20 and 50. Typical uses of the band included tracking exercise amount as measured by the number of steps taken and calories burned. Strap watch closure, a single color and achromatic color, and soft and smooth touch materials were preferred as band design. Second, two fabric-type fitness bands were designed and developed. Design 1 had a 3-dimensional pocket for the sensor, bright blue color, and stretch binding around the edges and for a loop. Design 2 had a flat pocket for the sensor, achromatic color, mesh binding around the edges and two metal loops. Both designs had Velcro as a closure. Third, wear testing of both bands with the sensor were conducted of 15 women in their 20s. They wore the bands during jump rope exercises. Both bands generally satisfied the participants. The Design 2 band was slightly more satisfying than the Design 1 band.

Endoscopic Intervention for Anastomotic Leakage After Gastrectomy

  • Ji Yoon Kim;Hyunsoo Chung
    • Journal of Gastric Cancer
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2024
  • Anastomotic leaks and fistulas are significant complications of gastric surgery that potentially lead to increased postoperative morbidity and mortality. Surgical intervention is reserved for cases with severe symptoms or hemodynamic instability; however, surgery carries a higher risk of complications. With advancements in endoscopic treatment options, endoscopic approaches have emerged as the primary choice for managing these complications. Endoscopic clipping is a traditional method comprising 2 main categories: through-the-scope clips and over-the-scope clips. Through-the-scope clips are user friendly and adaptable to various clinical scenarios, whereas over-the-scope clips can close larger defects. Another promising approach is endoscopic stent insertion, which has shown a high success rate for leak closure, although vigilant monitoring is required to monitor stent migration. Infection control is essential in post-surgical leakage cases, and endoscopic internal drainage provides a relatively safe and noninvasive means to manage fluids, contributing to infection control and wound healing promotion. Endoscopic suturing offers full-thickness wound closure, but requires additional training and endoscopic versatility. As a promising tool, endoscopic vacuum therapy potentially surpasses stent therapy by draining inflammatory materials and closing defects. Furthermore, the use of tissue sealants, such as fibrin glue and cyanoacrylate, has been reported to be effective in selected situations. The choice of endoscopic device should be tailored to individual cases and specific patient conditions, with careful consideration of the nature of the defect. Further extensive studies involving larger patient populations are required to provide more robust evidence on the efficacy of endoscopic approach in managing post-gastric anastomotic leaks.

Left Ventricular Assist Device Implantation via Dual Left Thoracotomy in an Adult Patient with Congenitally Corrected Transposition of the Great Arteries

  • Kim, Shin;Cho, Yang-Hyun;Park, Pyo Won;Lee, Young Tak;Jun, Tae-Gook;Kim, Wook Sung;Sung, Kiick;Yang, Ji-Hyuk;Chung, Suryeun
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.306-309
    • /
    • 2020
  • A 59-year-old man presented for possible durable ventricular assist device (VAD) implantation. He had previously been diagnosed with congenitally corrected transposition of the great arteries, a ventricular septal defect, an atrial septal defect, pulmonary valve stenosis, and aortic valve regurgitation. In the previous 22 years, he had undergone palliative cardiac surgery 3 times. VAD implantation as a bridge to transplantation was planned. Owing to severe adhesions, mesocardia, a left ascending aorta, and moderate aortic regurgitation, we performed VAD implantation and aortic valve closure via a dual left thoracotomy and partial sternotomy.

Information Types and Display Methods according to the Relation between Frequency of Exposure and Degree of Cognition (노출빈도와 인지도 관계에 따른 정보의 유형과 표현기법)

  • Han, Ji-Ae;You, Si-Cheon
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.497-504
    • /
    • 2012
  • Information types and display methods according to the relation between frequency of exposure and degree of cognition was suggested by this study as a way to enhance effective communication by information in aspect of user cognition. First of all, we ascertained the relation between frequency of exposure and degree of cognition by literature research for cognitive psychology and cognitive engineering psychology, results are as follows based in it. First, we suggested information types and attributes for visualization as 'Framework' which helps designers understand cognitive demands of users. Specifically, there are 4 types(STM, STA, LTM, LTA) of information according to the relation between frequency of exposure and degree of cognition, cognitive characteristics for each types and 'attributes matrix for visualization' which is consisted of 14 attributes of high -quality information and resorted by the types. Second, we suggested a guideline for display methods according to depth of information in the design process of information contents. For display methods of STM, STA information as primary information, we suggested "Attribution theory of Distinctiveness", "Advance Organizer", "Progress Closure", "Affordance", for display methods of LTM information as multidimensional information, we suggested "Modularity", "Consistency", "Mimicry", "Mnemonic Device". We had found from this study that there are distinction of status for attributes of information visualization according to information types or depth, and various display methods by them.

Transcatheter Closure of Patent Ductus Arteriosus with a Amplatzer$^{(R)}$ Vascular Plug in Two Dogs (개에서 Amplatzer$^{(R)}$ vascular plug를 이용한 동맥관개존증의 폐쇄 2 증례)

  • Kang, Min-Hee;Kim, Jung-hyun;Moon, So-Jeung;Kim, Seung-gon;Yeo, Jung-Jin;Lee, Chang-Min;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.591-594
    • /
    • 2011
  • A 9-month-old, intact female Maltese dog and one-year-old, intact female beagle dog were presented with continuous heart murmur. These 2 dogs were diagnosed as patent ductus arteriosus (PDA) based on the two-dimensional echocardiography and angiography. Due to the large shunt size, commercially available ductal occlude device was used for transcatheter occlusion of PDA. After Amplatzer$^{(R)}$ vascular plug placement, cardiac murmur was abruptly disappeared in Maltese dog and mildly decreased in beagle dog. Complications and safety after the procedure were evaluated regularly in these 2 dogs. This is first clinical application of Amplatzer$^{(R)}$ vascular plug for transcatheter closure of PDA in two dogs in Korea.

A new strategy for transcatheter closure of patent ductus arteriosus with recent-generation devices (경피적 동맥관 폐쇄술에서 최근의 기구들의 전략적 이용과 결과)

  • Kim, Sang Yee;Lee, Soo Hyun;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.488-493
    • /
    • 2009
  • Purpose : The aim of this study was to assess the efficacy and safety of recent-generation patent ductus arteriosus (PDA) closure devices applied by a new selection strategy according to the characteristics of each PDA. Methods : From February 2003 to January 2006, 138 patients underwent transcatheter closure of PDA (study group). According to the size and morphology of each ductus, a COOK Detachable Coil or 'flex' PFM Nit-Occlud was used for a small ductus (group 1, n=43); 'medium' PFM Nit-Occlud (group 2, n=49) for a moderate ductus; and an Amplatzer Duct Occluder (group 3, n=46) for a large ductus. The 83 patients who underwent transcatheter closure of PDA from February 2000 to January 2003 were defined as the comparison group. The Qp/Qs ratio, pulmonary/aorta pressure ratio, and MD of the ductus were compared. Immediate and follow-up results including residual shunts and complications were also evaluated and compared among groups. Results : In all 138 patients, complete occlusions were confirmed without major complications, while procedure failure (n=2, 2.2%), device embolization (n=1, 1.1%), and persistent residual shunt (n=4, 4.5%) were documented in the comparison group. Total complication rates were lower in the study group than in the comparison group (study group, 1.4%; comparison group, 9.0%; P<0.05). Conclusion : A novel strategy adopting the merits of various recent-generation devices for transcatheter closure of PDA provides excellent clinical results with minimal risk.

Reoperation of Postinfarction VSD (심근경색증의 합병증으로 발생한 심실중격 파열의 재수술)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.528-532
    • /
    • 1997
  • After early surgical repair of ventricular septal rupture complicated by myocardial infarction, newly developed ventricular septal defects were discovered on the 7th and the 40th postoperative day in 2 cases. We reoperated these patients for closure of newly developed ventricular septal defects with Dacron patch successfully on the 77th and the loth day after discovery of those defects. From these results we conclude that early surgical rep ir for ruptured ventricular septum following myocardial infarction is an appropriate approach with low risk and that remnant or recurred ventricular septal defect can be corrected rather safely with proper myocardial preservation and unrestricted application of intraaortic balloon pump or other ventricular assist device.

  • PDF

Clinical Evaluation of Surgical Resection of Pulmonary Tuberculosis (폐결핵 환자에 적용된 폐절제 요법에 관한 검토: Automatic stapling device를 이용한 절제례의 검토)

  • 최강주
    • Journal of Chest Surgery
    • /
    • v.24 no.8
    • /
    • pp.782-791
    • /
    • 1991
  • In Pusan Paik Hospital, Inje University, we experienced 174 cases of pulmonary resections for pulmonary tuberculosis from Jun. 1979 to Feb. 1990. In all of them automatic stapling devices were used for division of lung parenchyme and /or bronchial closure. The results were as follows; l. In 174 cases[male 100, female 74], third and fourth decades were 116 cases [66.7%]. 2. Indications for lung resection in the radiographic findings were destroyed lung 47 cases[27.0%], destroyed lobe 42 cases[24.1%], cavitary lesions 42 cases[24.1%], tuberculoma 22 cases[12.7%], and bronchial lesions 21 cases[12.1%]. 3. The mean of staplers used in the operations was 1.6, and possible stapler-associated complications were only 2 cases of bronchopleural fistula after pneumonectomy. 4. Twenty-seven of 36 patients with bilateral lesions and 52 of unilateral ones on chest X-ray films were AFB positive on preoperative sputum smears. Twenty-three[85.2%] of bilateral lesions and 51[98.1%] of unilateral ones were AFB negative at 6 months after operations. 5. Main complications of resections were operative death 1[0.6%], empyema 4[2.3%], respiratory insufficiency 3[1.7%], pleural dead space 5[2.9%], and bronchial spreading of tuberculosis 2[1.1%]. Bronchopleural fistula were only 2 cases after pneumonectomy and none after lobectomy or segmentectomy. 6. One hundred and forty two patients[92.8%] of 153 with available follow-up data were in the state of good quality of life.

  • PDF

Numerical Study on the Waterhammer of PalDang Intake Pumping Station (팔당 취수펌프장의 수격현상에 관한 수치해석적 연구)

  • Kim, Kyung-Yup;Yu, Teak-In
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.52-58
    • /
    • 2000
  • The numerical study on the waterhammer was carried out for the intake pumping station of the metropolitan water supply 6th stage project. Because the waterhammer problems as a result of the pump power failure were the most important, these situations were carefully investigated. The surge tank and the stand pipes effectively protected the tunnels md the downstream region of pipeline from the pressure surge. In case the moment of inertia of the pump and motor was above $5080\;kg{\cdot}m^2$, the column separation did not occur in the pipeline between the pumping station and the inlet of 1st tunnel. As the moment of inertia increased, the pressure surges decreased in the pipeline conveying raw water. The pump control valve was chosen as the main surge suppression device for the intake pumping station. After power failure, the valve disc should be rapidly closed in 2.5 seconds and controlled the final closure to 15 seconds by the oil dashpot. If the slamming happened to the pump control valve, there was some danger of this system damaging. As the reverse flow through the valve increased, the upsurge extremely increased.

  • PDF

Examination of Cavitation-Induced Surface Erosion Pitting of a Mechanical Heart Valve Using a Solenoid-Actuated Apparatus

  • Lee, Hwan-Sung;Hwang, Sung-Won;Katsuyuki Yamamoto
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1339-1348
    • /
    • 2003
  • Several factors, including peak dp/dt of the ventricular pressure and maximum closing velocity of leaflet have been studied as indices of the cavitation threshold. In the present study, just before closing velocity of the leaflet has been studied as indices of the cavitation threshold, and cavitation erosion on the surface of a mechanical valve was examined by focusing on squeeze flow and the water hammer phenomenon during the closing period of the valve. A simple solenoid-actuated test device that can directly control the valve closing velocity was developed, and opening-closing tests of 3,000 and 40,000 cycles were performed at various closing velocities. There was a closing velocity threshold to occur erosion pitting of valve surface, and its value was about 0.4 m/s in this study. Cavitation-induced erosion pits were observed only in regions where squeeze flow occurred immediately before valve closure On the other hand, the number of the pits was found to be closely related to an area of water hammer-induced pressure wave below the critical pressure defined by water vapor pressure. Therefore, it was concluded that cavitation is initiated and augmented by the two pressure drops due to squeeze flow and water hammer phenomenon, respectively.