• Title/Summary/Keyword: Development of Evaluation Indicator

Search Result 287, Processing Time 0.023 seconds

Study on Developing Assessment Guideline for Safety and Performance of Electric Cupping Apparatus (전동식 부항기에 대한 안전성 및 성능평가 가이드라인 개발연구)

  • Yi, Seung-Ho;Kim, Eun-Jung;Shin, Kyung-Hoon;Nam, Dong-Woo;Kang, Jung-Won;Lee, Seung-Deok;Lee, Hye-Jung;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.101-110
    • /
    • 2009
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric cupping apparatus(Class 2 medical device). Methods : We drafted the guideline for safety and performance assessment of electric cupping apparatus by referring the existing standards and guideline, based on online questionnaire for Korean medical doctors and measurement data from commercially available products. Physical dimension of cups and inner vacuum pressure were acquired for the measurement in order to achieve the purposes. Results : This guideline only can be applied to electric cupping apparatus for enhancing blood circulation by employing negative pressure generated by electricity. Seven items of appearance and label, operation test of pump, variation test of input electricity, vacuum level test, vacuum sustain test, cup-size dependent test, noise level test are suggested for evaluation subjects and methods required for electric cupping devices. Requirements for the design and development of electric cupping devices are suggested: vacuum level indicator, vacuum generation rate, pressure control, valve detachment stability, cup comparability, safety measure, surge protection, user friendliness, instruction for use (IFU). Conclusions : We proposed a guideline for safety and performance assessment of electric cupping apparatus to improve the quality of relating products and aid the commercialization of them, by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

  • PDF

Environmental Capacity Assessment of Busan City (부산시 환경용량평가에 관한 연구)

  • Hwang, Kyung-Yup;Hwang, Inseong;Lee, Soon-Kyu;Jo, Seung-Wu;Oh, Kwang-Joong
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.1
    • /
    • pp.79-92
    • /
    • 2006
  • Environmental capacity assessment of Busan city was conducted to provide basis for planning on sustainable development and growth of the city. Using Onish model, assessment was carried out on amenities and service facilities for the citizens of Busan city. Ecological Footprint model was used to judge if the city exceeds the its environmental capacity and to estimate the extent of the excess if it exists. The analysis using Onish model revealed that the citizens of Busan city are generally well supported by the infrastructure and service facilities of the city. Water treatment and supply facilities have enough capabilities to support the city, whereas the relatively low rate of sanitary sewer supply (78%) suggests the need for further improvement in the wastewater area. The capacities of sanitary landfills are found sufficient enough to support the city for the next 10 years. The high value for the line length served per capita in the subway sector hints on certain inconvenience of commuters. All the air quality indicators meet the Korean and WHO standards except for $NO_2$. The ecological footprint model analysis produced EF indicators for Busan city of 3.04 ha/person and 2.54 ha/person for the years of 1993 and 2003, respectively. The decrease of the indicator from 1993 to 2003 is mainly due to the incorporation of Gijang area by Busan city in 1995, suggesting the importance of the ecologically productive area in the evaluation using this model. The analysis on the ecological deficit that is based on ecologically productive land shows that the consumption by Busan city exceeds its ecologically available production by 19,600% as of 2003. The area needed to support the consumption of Busan city in 2003 is 123 times as large as the present area of Busan city, which is substantially lower than the multiplier (742) obtained for Seoul city in 1997 but is higher than those observed for Chongju city (71 in 1999) and Ulsan city (39 in 2001).

A Study on the Development of Urine Analysis System using Strip and Evaluation of Experimental Result by means of Fuzzy Inference (스트립을 이용한 요분석시스템의 개발과 퍼지추론에 의한 검사결과 평가에 관한 연구)

  • Jun, K. R.;Lee, S. J.;Choi, B. C.;An, S. H.;Ha, K.;Kim, J. Y.;Kim, J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 1998
  • In this paper, we implemented the urine analysis system capable of measuring a qualitative and semi-quantitative and assay using strip. The analysis algorithm of urine analysis was adopted a fuzzy logic-based classifiers that was robust to external error factors such as temperature and electric power noises. The spectroscopic properties of 9 pads In a strip were studied to developing the urine analysis system was designed for robustnesss and stability. The urine analysis system was consisted of hardware and software. The hardware of the urine analysis system was based on one-chip microprocessor, and Its peripherals which composed of optic modulo, tray control, preamplifier, communication with PC, thermal printer and operating status indicator. The software of the urine analysis system was composed of system program and classification program. The system program did duty fort system control, data acquisition and data analysis. The classification program was composed of fuzzy inference engine and membership function generator. The membership function generator made triangular membership functions by statical method for quality control. Resulted data was transferred through serial cable to PC. The transferred data was arranged and saved be data acquisition program coded by C+ + language. The precision of urine analysis system and the stability of fuzzy classifier were evaluated by testing the standard urine samples. Experimental results showed a good stability states and a exact classification.

  • PDF

Development of a Pulse Wave Velocity Measurement System and Assessment of the System Reproducibility for the Diagnosis of Arteriosclerosis (동맥경화 진단을 위한 맥파전달속도 측정시스템 개발 및 재현성 평가)

  • Lee, Nak-B.;Im, Jae-J.;Park, Young-B.;Jeon, Young-J.
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.112-124
    • /
    • 2005
  • Background: PWV is determined by dividing the distance by the time taken for the pulses traveling between two measuring sites, used as a marker of arterial stiffness and an important indicator for cardiovascular disease. Methods: A PWV measurement system, which offers a non-invasive, simple method of measurement, and simultaneous recording of six signlas(ECG, PCG and four pulse waves from carotid, femoral, radial and dorsalis pedis arteries) was developed. Seventeen healthy subjects with a mean age of 33 years(22 to 52) without any cardiovascular disease were participated for the experiment. Two observers(A and B) performed two consecutive measurements from the same subject in a random order. For the evaluation of stability and accuracy of the PWV measurement system, reproducibility of PWV from between-observer were also evaluated. Results: PWV $values(Mean{\pm}SD)$ measured by A were $7.07{\pm}1.48m/s$, $8.43{\pm}1.14m/s$ , $8.09{\pm}0.98m/s$ for aorta, arm, and leg, respectively. The values obtained from B were $6.76{\pm}1.00m/s$, $7.97{\pm}0.80m/s$, and $7.97{\pm}0.72m/s$ for aorta, arm, and leg, respectively. Between-observer $differences(mean{\pm}SEM)$ from the aorta, arm and leg were $0.14{\pm}0.15m/s$, $0.18{\pm}0.10m/s$ and $0.07{\pm}0.10m/s$. Reproducibility coefficients(2SD) from the aorta, arm, and leg were 0.62m/s, 0.84m/s and 0.86m/s. Correlation coefficients were significantly higher in aortic PWV, 0.93, compared to the coefficients for arm and leg. Coefficient of variance which reflects the reproducibility of the system ranged from $4.4{\sim}5.8%$ in all regional PWV. , Conclusion: Reproducibility of PWV in the study shows that the developed system has reliable and reproducible characteristics. The PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis and results with high reproducibility. Results of the PWV measurement system could contribute to various clinical applications in the future.

  • PDF

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

Development and application of integrated indicators for assessing the water resources performance of multi-purpose and water supply dams (댐 용수공급능력 안정성 평가를 위한 통합지표 개발 및 적용)

  • Sung, Jiyoung;Kang, Boosik;Kim, Bomi;Noh, Seongjin
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.9
    • /
    • pp.687-700
    • /
    • 2022
  • For comprehensively assessment the water resources performance of multi-purpose dams and water supply dams in South Korea, a methodology was proposed to utilize the durational reliability along with the integrated auxiliary indicators including resiliency, dimensionless vulnerability, water resource efficiency, specific inflow, and specific water supply. In addition, for the purpose of sustainable dam operation in the future, a plan to grade the water resources performance was presented to periodically evaluate the performance and determine the priority of each dam's structural or non-structural planning according to the evaluation results. As major results, in the case of Sumjingang Dam, the durational reliability was 99.0%, but the integrated auxiliary index was the lowest of 44 points, which was 5th grade. This means that despite the current high reliability, hydrological changes due to future climate change or regional change of water demand-supply balance can have significant impacts on the water resources performances. In contrast, the Chungju Dam with a durational reliability of 93.0%, which is below the average among all multi-purpose dams, shows the 76 points of the integrated auxiliary index, which is 3rd highest following the Soyanggang Dam and the Namgang Dam. Nevertheless, due to the size of the basin, the specific inflow is sufficiently high as 185%, so the actual performance could be evaluated relatively high. The water supply dams designed for a single purpose tend to be evaluated relatively high because they have a high proportion of industrial and municipal water supply and have enough room for the supply capacity.

Learning Ability Prediction System for Developing Competence Based Curriculum: Focusing on the Case of D-University (역량중심 교육과정 개발을 위한 학업성취도 예측 시스템: D대학 사례를 중심으로)

  • Kim, Sungkook;Oh, Chang-Heon
    • Journal of Practical Engineering Education
    • /
    • v.14 no.2
    • /
    • pp.267-277
    • /
    • 2022
  • Achievement at university is recognized in a comprehensive sense as the level of qualitative change and development that students have embodied as a result of their experience in university education. Therefore, the academic achievement of university students will be given meaning in cooperation with the historical and social demands for diverse human resources such as creativity, leadership, and global ability, but it is practically an indicator of the outcome of university education. Measurement of academic achievement by such credits involves many problems, but in particular, standardization of academic achievement by credits based on evaluation methods, contents, and university rankings is a very difficult problem. In this study, we present a model that uses machine learning techniques to predict whether or not academic achievement is excellent for D-University graduates. The variables used were analyzed using up to 96 personal information and bachelor's information such as graduation year, department number, department name, etc., but when establishing a future education course, only the data after enrollment works effectively. Therefore, the items to be analyzed are limited to the recommended ability to improve the academic achievement of the department/student. In this research, we implemented an academic achievement prediction model through analysis of core abilities that reflect the philosophy, goals, human resources image, and utilized machine learning to affect the impact of the introduction of the prediction model on academic achievement. We plan to apply the results of future research to the establishment of curriculum and student guidance conducted in the department to establish a basis for improving academic achievement.

Evaluation Methods of Soil Resilience Related to Agricultural Environment (농업환경 분야에서 토양 리질리언스 분야별 평가 방법)

  • Kim, Min-Suk;Min, Hyun-Gi;Hyun, Seung-Hun;Kim, Jeong-Gyu
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.2
    • /
    • pp.97-113
    • /
    • 2020
  • Soil is the foundation of human life and the basis for food security. Considering this it is prioritized in the UN's Sustainable Development Goals (SDG). Therefore, research on soil resilience in the agricultural environment is crucial for sound and sustainable soil management, especially in highly uncertain and unpredictable conditions. Soil resilience is defined in different ways by several researchers; however, its definition typically includes the concepts of recovery and resistance to stress. The physical, chemical, and biological characteristics of soils that are used to assess the soil resilience, i.e., the response of soil to various types of stress are summarized in this study. In addition, various statistical processing techniques and quantification methods are summarized considering the wide spatial and temporal scope of soil resilience research. Several soil resilience studies typically conduct the following five steps: (1) soil and site selection (2) stress (independent variable) setting (3) soil characteristics and indicator (dependent variable) setting (4) performing various spatiotemporal scale experiments (5) statistical analysis. The previous and present studies present a general introduction of soil resilience, based on which, further practical research considering domestic agricultural environment should be conducted. The extensive range of soil resilience measurements will require collaboration between researchers in various fields.

Evaluation of Basin-Specific Water Use through Development of Water Use Assessment Index (이수평가지수 개발을 통한 유역별 물이용 특성 평가)

  • Baeck, Seung Hyub;Choi, Si Jung
    • Journal of Wetlands Research
    • /
    • v.15 no.3
    • /
    • pp.367-380
    • /
    • 2013
  • In this study, sub-indicators, and thematic mid-indexes to evaluate the water use characteristics were selected through historical data analysis and factor analysis, and consisted of the subject approach framework. And the integrated index was developed to evaluate water use characteristics of the watershed. Using developed index, the water use characteristics were assessed for 812 standard basins with the exception for North Korea using data of 1990 to 2007 from the relevant agencies. A sensitivity analysis is conducted for this study to determine the proper way through various normalization and weighting methods. To increase the objectivity of developed index, the history of the damage indicators are excluded in the analysis. In addition, in order to ensure its reliability, results from index with and without consideration of the damage history were compared. Also, the index is also applied to real data for 2008 Gangwon region to verify its field applicability. Through the validation process this index confirmed the adequacy for the indicators selection and calculation method. The results of this study were analyzed based on the spatial and time vulnerability of the basin's water use, which can be applied to various parts such as priority decision-making for water business or policy, mitigations for the vulnerable components of the basin, and supporting measures to establishment by providing relevant information about it.

Experience Analysis on the Selection of the 2015 Revised Science Authorized Textbook by Elementary School Teachers (초등학교 교사의 2015 개정 과학과 검정 교과서 선정 경험 분석)

  • Chae, Heein;Noh, Sukgoo
    • Journal of Korean Elementary Science Education
    • /
    • v.42 no.1
    • /
    • pp.194-209
    • /
    • 2023
  • This study aims to present implications for the appropriate establishment and development of a science-authorized textbook system through an understanding of the process of selecting science-authorized textbooks and analyzing the perception of teachers. Toward this end, this study conducted interviews with five elementary school teachers who participated in the science textbook selection process, surveys on 32 teachers, and analysis on the authors of the textbooks. The result demonstrated, first, that the "opinion gathering" stage was the most important one, and a council was formed in consideration of career and major. Moreover, the evaluation standard was reorganized and used according to the situation of the school. Second, in the process of opinion gathering, the teachers used a method for reviewing the entire textbook for each teacher. Inquiry activities and textbook composition (readability) were crucially considered as internal factors, and teaching and learning materials, such as videos, were deemed extremely important as external factors. The variable of the author, which is an indicator of the reliability and expertise of textbooks, was also recognized as vital. Third, the deliberation by the School Committee and the report by the principal were recognized as the administrative final step after selection. Finally, selecting the most suitable textbooks for each grade group was recognized as more important than arbitrarily unifying textbooks for the third and fourth grades and for the fifth and sixth grades.