• 제목/요약/키워드: Development Scheme

검색결과 2,359건 처리시간 0.032초

공동이 있는 수직 분사 초음속 연소기 내의 불안정 연소유동 해석 (Numerical Analysis of Unstable Combustion Flows in Normal Injection Supersonic Combustor with a Cavity)

  • Jeong-Yeol Choi;Vigor Yang
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.91-93
    • /
    • 2003
  • A comprehensive numerical study is carried out to investigate for the understanding of the flow evolution and flame development in a supersonic combustor with normal injection of ncumally injecting hydrogen in airsupersonic flows. The formulation treats the complete conservation equations of mass, momentum, energy, and species concentration for a multi-component chemically reacting system. For the numerical simulation of supersonic combustion, multi-species Navier-Stokes equations and detailed chemistry of H2-Air is considered. It also accommodates a finite-rate chemical kinetics mechanism of hydrogen-air combustion GRI-Mech. 2.11[1], which consists of nine species and twenty-five reaction steps. Turbulence closure is achieved by means of a k-two-equation model (2). The governing equations are spatially discretized using a finite-volume approach, and temporally integrated by means of a second-order accurate implicit scheme (3-5).The supersonic combustor consists of a flat channel of 10 cm height and a fuel-injection slit of 0.1 cm width located at 10 cm downstream of the inlet. A cavity of 5 cm height and 20 cm width is installed at 15 cm downstream of the injection slit. A total of 936160 grids are used for the main-combustor flow passage, and 159161 grids for the cavity. The grids are clustered in the flow direction near the fuel injector and cavity, as well as in the vertical direction near the bottom wall. The no-slip and adiabatic conditions are assumed throughout the entire wall boundary. As a specific example, the inflow Mach number is assumed to be 3, and the temperature and pressure are 600 K and 0.1 MPa, respectively. Gaseous hydrogen at a temperature of 151.5 K is injected normal to the wall from a choked injector.A series of calculations were carried out by varying the fuel injection pressure from 0.5 to 1.5MPa. This amounts to changing the fuel mass flow rate or the overall equivalence ratio for different operating regimes. Figure 1 shows the instantaneous temperature fields in the supersonic combustor at four different conditions. The dark blue region represents the hot burned gases. At the fuel injection pressure of 0.5 MPa, the flame is stably anchored, but the flow field exhibits a high-amplitude oscillation. At the fuel injection pressure of 1.0 MPa, the Mach reflection occurs ahead of the injector. The interaction between the incoming air and the injection flow becomes much more complex, and the fuel/air mixing is strongly enhanced. The Mach reflection oscillates and results in a strong fluctuation in the combustor wall pressure. At the fuel injection pressure of 1.5MPa, the flow inside the combustor becomes nearly choked and the Mach reflection is displaced forward. The leading shock wave moves slowly toward the inlet, and eventually causes the combustor-upstart due to the thermal choking. The cavity appears to play a secondary role in driving the flow unsteadiness, in spite of its influence on the fuel/air mixing and flame evolution. Further investigation is necessary on this issue. The present study features detailed resolution of the flow and flame dynamics in the combustor, which was not typically available in most of the previous works. In particular, the oscillatory flow characteristics are captured at a scale sufficient to identify the underlying physical mechanisms. Much of the flow unsteadiness is not related to the cavity, but rather to the intrinsic unsteadiness in the flowfield, as also shown experimentally by Ben-Yakar et al. [6], The interactions between the unsteady flow and flame evolution may cause a large excursion of flow oscillation. The work appears to be the first of its kind in the numerical study of combustion oscillations in a supersonic combustor, although a similar phenomenon was previously reported experimentally. A more comprehensive discussion will be given in the final paper presented at the colloquium.

  • PDF

유전 알고리듬을 적용한 지능형 ATP 시스템 개발 (Development of Intelligent ATP System Using Genetic Algorithm)

  • 김태영
    • 지능정보연구
    • /
    • 제16권4호
    • /
    • pp.131-145
    • /
    • 2010
  • ERP, SCM 등과 같은 기업용 정보 시스템을 활용함에 있어, 고객의 문의에 따라 제품 판매 가능 유무와 가능일자를 계산하여 통보해 주는 지능형 ATP 시스템은 전산 정보를 활용하여 고객 만족도를 최대화할 수 있는 유용한 기능이라고 할 수 있다. 그렇지만 공급 사슬 환경에서 ATP 시스템을 적용하려고 할 경우, 고객이 문의해 온 Retailer에게 납품 가능한 모든 분배센터(Distribution Center)와 공장(Plant)의 미래 시점의 재고량 변화와 운송 능력 등을 모두 고려하여야 하므로 계산량이 방대한 NP-Complete 문제가 된다. 따라서 시스템 사용자가 빠른 시간 내에 해를 구하여 고객에게 결과를 알려 줄 수 있는 ATP 시스템의 개발은 공급 사슬 관리를 효과적으로 활용하기 위하여 반드시 필요한 일이라고 할 수 있다. 본 논문에서는 동적 생산 함수의 개념을 이용하여 비 정수 타임 랙을 고려하여 ATP 시스템을 모델링하고, 해당 수리 모형으로부터 효율적으로 해를 얻기 위하여 유전 알고리듬을 개발하였다. 비 정수 타임 랙을 활용한 ATP 시스템은 비 정수 타임 랙을 올림이나 내림을 통하여 정수화 시킨 후 모형 수립하는 기존의 방법보다 정교하게 현실을 반영할 수 있고, ATP 시스템을 위한 유전 알고리듬의 진화 시스템은 문제크기가 작은 것에서부터 큰 것까지 최적해에 매우 근사한 값을 매우 빠른 시간 내에 풀 수 있음을 알 수 있었다.

가우시안 군집분석을 이용한 천리안 위성의 대기운동벡터 표적추적 알고리듬 개발 및 분석 (Development and Analysis of COMS AMV Target Tracking Algorithm using Gaussian Cluster Analysis)

  • 오유림;김재환;박형민;백강현
    • 대한원격탐사학회지
    • /
    • 제31권6호
    • /
    • pp.531-548
    • /
    • 2015
  • 위성영상을 이용하여 산출된 대기운동벡터(AMV)와 라디오존데 바람 관측 자료를 이용한 검증결과는 산출된 AMV가 지속적으로 관측 자료에 비해서 풍속이 약하게 나타나는 Slow Speed Bias(SSB)를 보여 주었다. 이러한 SSB는 표적추적, 표적선정, 그리고 고도할당 단계의 오차에 의해 야기될 수 있으며, 이 중 고도할당 단계의 오차는 SSB를 발생시키는 주된 요인으로 여겨진다. 그러나 최근 연구에서는 고도할당 단계의 개선만으로는 SSB 문제를 해결하는데 한계가 있음을 밝혔다. 그러므로 본 연구에서는 새로운 표적추적 알고리듬을 개발하여 SSB를 감소시킴으로서 기상청 현업 AMV 알고리듬의 성능을 개선하고자 하였다. 표적추적 단계의 오차는 표적 내에 다양한 시 공간 규모의 바람이 포함되어 벡터가 과도하게 평균된 움직임으로 계산되거나, 구름이 추적 시간동안 형태를 유지하지 못하고 변형되는 경우에 발생한다. 이러한 문제를 해결하기 위해 개발된 표적추적 알고리듬에서는 가우시안 군집분석(GMM)을 이용하여 변형이 적고 추적에 용이한 저온 군집을 표적으로 재선정하고, 이미지를 변형시켜 군집의 움직임을 보다 쉽게 추적할 수 있게 하였다. 또한 표적을 추적하기 위한 방법으로 거리제곱합 방법을 사용하였다. 개발된 알고리듬과 기존 COMS 알고리듬을 천리안 위성의 적외채널 영상에 적용하여 AMV를 산출하였으며, 이를 라디오존데 관측 자료와 비교 검증해 보았다. 제안된 알고리듬으로 산출된 AMV는 기존 알고리듬으로 산출된 AMV보다 평균 풍속이 $2.7ms^{-1}$증가함에 따라 SSB가 평균 29%까지 감소하는 개선된 결과를 보여주었다. 그러나 개발된 알고리듬으로 산출된 AMV는 중 하층의 정확도가 감소하였고, 기존 알고리듬에 비해 산출되는 AMV 벡터수가 약 40%까지 감소함을 보였다. 이에 따라 중 하층의 정확도 개선과 기존의 알고리듬과 비교하여 산출되는 벡터 개수가 감소하는 문제를 보완하기 위한 연구가 필요할 것으로 판단된다.

한국형 총식이조사 및 UV/태양광 조사 버섯에서의 비타민 D 분석 (Vitamin D analysis in the Korean total diet study and UV/sun light irradiated mushrooms)

  • 서민정;노인화;이지연;권성옥;김초일;이계호
    • 한국식품저장유통학회지
    • /
    • 제30권1호
    • /
    • pp.109-121
    • /
    • 2023
  • 본 연구에서 식품 중 비타민 D 주요 급원으로 선정한 버섯류(3종), 어패류(10종), 알류(1종), 육류(7종), 두류(1종), 유류(4종), 가공식품(3종), 유지류(1종)로, 총 30종에 대표 조리법을 포함한 148건에 대해 LC-MS/MS를 이용하여 분석하였다. 우리 국민 평균 총식이섭취량의 90% 이상을 포괄하는 대상 식품을 선별 후 식생활에서 활용되는 조리법 선정을 통해 조제된 실제 섭취 상황에 가까운 한국형 총식이조사를 기반한 '대표 식품×대표 조리법'으로서 새송이버섯(굽기), 가다랭이(그대로) 등 53종으로 6개의 지역별 시료를 불검출의 경우 1건만 분석하였고, 검출된 경우 6건 전부 분석하여 총 148건에 대해 비타민 D 함량 및 섭취량을 추정하였다. 분석은 유효성검증 및 국제 분석 관리프로그램인 FAPAS를 참여하여 숙련도 테스트 결과, Z-score 2 이하의 만족하는 결과를 얻어 신뢰도를 검증하였다. 본 연구에서 분석한 '대표 식품×대표 조리법'의 비타민 D 결과는 어류에서는 멸치(볶기)에서 124.0 ㎍/kg의 농도로 가장 높게 검출되었고, 두 번째로 고등어(굽기)에서 120.2 ㎍/kg의 농도로 검출이 되었다. 달걀의 경우 달걀(끓이기)은 검출되지 않았고, 달걀(부치기)에서 최고 33.1 ㎍/kg의 농도로 검출이 되었다. 육류에서는 닭고기와 쇠고기는 전부 검출되지 않았고, 돼지고기의 경우 굽기에서 12.2 ㎍/kg으로 검출되었다. 유제품의 경우 요구르트(액상)에서 136.9 ㎍/kg, 가공식품 중 시리얼의 경우, 155.1 ㎍/kg의 농도로 비타민 D가 검출이 되었는데, 이는 비타민 D 강화 제품으로 보인다. 생표고버섯을 햇빛에 12시간 노출 시에 비타민 D 함량이 303.4 ㎍/kg으로 높았으며, 건조형태에 따라 갓이 위로 향할 때보다, 주름부분을 위로 향하였을 때 비타민 D2의 함량이 높음을 확인하였다. 비타민 D 함량 분석 결과를 토대로 섭취량을 추정한 결과, 우리 국민의 1인 1일 평균 비타민 D 섭취량은 0.99 ㎍/day이었으며, 비타민 D 섭취량에 기여한 중요 3가지 식품은 요구르트, 액상(31.3%), 달걀(28.1%), 시리얼(11.4%) 순이었다. 보건복지부와 한국영양학회에서 제공하는 한국인 영양소 섭취기준(2020년) 중 비타민 D의 1일 충분 섭취량(영양소의 필요량을 추정하기 위한 과학적 근거가 부족할 경우, 대상 인구집단의 건강을 유지하는 데 충분한 양을 설정한 수치)은 영유아 5 ㎍/day, 남녀 6세부터 75세 이상 5-15 ㎍/day로 본 연구에서 추정한 1인 1일 평균섭취량과 비교하였을 때, 우리 국민의 비타민 D 섭취가 부족하다는 것을 확인할 수 있었다. 비타민 D 부족을 개선하기 위해 생활양식이나 식습관을 통해 비타민 D를 증가시킬 수 있는 식품을 섭취하고, 부족한 부분은 보충제를 통한 비타민 D 섭취가 필요할 것으로 보인다. 버섯의 경우 햇빛 또는 자외선에 노출시키면 비타민 D 섭취량을 높일 수 있다. 식습관을 통해 비타민 D 부족을 개선할 수 있는 다양한 연구가 필요하다고 생각된다.

수도집단재배의 기술체계에 관한 연구 (Study on the Technological System of the Cooperative Cultivation of Paddy Rice in Korea)

  • 조민신
    • 한국작물학회지
    • /
    • 제8권1호
    • /
    • pp.129-177
    • /
    • 1970
  • 수도작에 있어서 수량성의 향상과 경영의 합리화률 기하기 위한 집단재배의 기술체계를 확립하고자 지역과 지대별로 임의선정된 18개소에서 집단재배와 개별재배를 한 수도에 대하여 경종 및 생육ㆍ수량구성요소의 변이를 조사연구하였으며 460개소의 집단재배와 개별재배에 대하여 경종ㆍ경영 및 조직운영등을 비교조사하고 집단재배와 개별재배의 경제성을 분석하여 그 결과를 요약하면 아래와 같다. 1. 집단재배와 개별재배의 경종 및 생육ㆍ수량형질에 관하여 연구한 결과는 다음과 같다. (1) 육묘에 있어서 집단재배가 비료의 3요소 특히 인산과 가리의 사용량이 많았고 약제살포의 횟수도 많았다. (2) 본답에 있어서의 경종기술은 집단재배가 개별재배보다 ${\circled1}$ 이앙기가 빨랐고 ${\circled2}$ 재식밀도에 있어서 1주당 재식묘수는 적으나 단위면적당의 포기수는 많으며 \circled3 시비량은 질소, 인산, 가리 및 퇴비의 시용량이 현저히 많았고 ${\circled4}$ 분시횟수도 많았으며 ${\circled5}$ 살충제 및 살균제의 살포횟수도 역시 집단재배에서 많았다. (3) 도북의 정도는 집단재배가 약간 더 하였고 병해충의 발생정도는 잎도열병, 목도열병 그리구 멸구, 이화명충 1화기 및 2화기의 발생이 집단재배가 적었다. (4) 집단재배를 한 수도의 간장 및 수장은 길고 고중도 무거웠다. 그리고 조고비율은 집단재배에 있어서 80.9%, 개별재배가 69.9%로서 높은 유의차가 있었다. (5) 수량구성요소인 수수와 1수평균영화수가 집단재배에서 현저히 많았고 현미 1000립중도 무거웠으며 등숙율은 개별농가의 벼와 차이가 없었고 그 변이계수는 집단재배가 개별재배에 비하여 모두 작은 값을 보였다. (6) 현미수량은 평균 10a당 집단재배 459.0kg, 개별재배 374.8kg으로서 84.2kg이나 전자가 많았으며 그들간의 변이계수는 집단재배에서 작게 나타났다. (7) 기간재배기술과 수량구성요소의 상관관계에 있어서 고도의 유의상관을 보인 것은 파종기와 1수영화수, 못자리 약제살포횟수와 1수영화수, 이앙기와 1수영화수, 본답의 인산시용량과 수량, 본답의 가리시용량과 등숙율, 분시횟수와 수량등에서 정(+)상관을 보였고 파종기와 등숙율간에는 부(-)상관을 보였다. 2. 집단재배와 개별재배의 경종\ulcorner경영 및 조직운영에 대하여 종합적으로 조사비교한 결과는 다음과 같다. (1) 집단재배의 품종수는 13개이고 개별재배에서는 47품종으로서 개별재배가 품종의 단순화를 기하지 못하고 있다. (2) 육묘기술에 있어서 비료3요소 특히 인산과 가리의 시용량이 많았고 약제살포횟수가 많다는 것은 1ㆍ의 실험결과와 같으며 이밖에 집단재배의 경우에는 종자소특이 100% 실시되었으며 파종량도 3.3$m^2$당 표준파종량인 3.6~5.4이 파종이 많이 실시되었으나 개별재배에서는 박파와 밀파가 많아 파종량의 변이가 컸었다. (3) 이앙기, 재식밀도, 병충해방제, 약제살포횟수, 시비량 및 분시횟수등은 1.의 결과와 같으며 추경 및 객토와 동력경운기의 사용은 집단재배에서 많았으며 이앙방식은 종전의 정방형식에서 극단적인장방형식으로 많이 바뀌었으며 물관리에 있어서는 중각낙수와 간단관수가 비교적 많이 실시되었다. (4) 현미수량은 평균 10a당 집단재배가 466kg이고 개별재배는 380kg으로서 전자가 86kg 많았다. (5) 병충해방제작업이 집단재배에서 집단방제로 많이 실시되었고 종자소독도 80% 이상의 공동으로 이루어 졌으며 수확, 수확물의 운반, 탈곡, 논갈이 작업등도 개별재배에서 보다 많이 공동으로 이루어졌다. (6) 집단재배에서 객토 및 퇴비의 사용이 현저히 많았으며 그 작업도 공동으로 이루어진 비율이 높고 또한 노동력의 투입도 많았다. (7) 육묘 및 본답의 물관리작업은 집단재배가 개별재배보다 노동력의 투입이 적었다. (8) 비료, 농약 및 노동력등의 비용가액은 집단재배가 개별재배보다 많았으며 약 2배에 가까웠다. (9) 경영규모는 3ha로부터 7ha 이상의 범위에 있으며 5ha내외의 것이 많았고 1개소의 집단재배는 10~20개 정도의 필지로 되어있는 것이 대부분이었다. (10) 경영자 및 경작자의 학력은 집단재배의 회장, 재배반장, 방제반장 및 수리반장 모두 국민학교졸업 이상이 93.7%이며 개별재배는 83%를 보였고 그들의 연령은 40~45세가 가장 많으며 이러한 경향은 양자가 비슷하였다. (11) 집단재배의 운영에 관한 주요설문에 대한 경작자들의 반응은 집단재배를 함으로서 확실히 수량은 증가하였는데 이것은 시비법개선과 병충해방제의 효과가 가장 컸다고 생각하는 사람이 많았고 집단재배를 함으로서 영농자재의 입수와 모든 작업이 적기에 이루어 졌다고 하는 것이 많았다. 또한 경작노력은 적게 들었다는 것이 66.8%이며 이앙노력은 집단재배가 오히려 더 들었다는 것 그리고 관의 간섭이 많았다는 것 등이 특이한 것이며 집단재배의 계속을 원하는 농가가 74.5%이고 원치 않은 농가가 25.5%였었다. 3. 집단재배와 개별재배의 경제성을 분석한 결과는 다음과 같다. (1) 경영비의 비용가액중 퇴비, 금비, 농약대 및 고용노임은 집단재배에 있어서 개별재배보다 각각 335원, 199원, 388원 및 303원이 더 투입되어 큰 차이를 보였으나 기타생산비목들은 집단재배와 개별재배간에 큰 차이가 없었다. (2) 총수익에서 경영비를 뺀 소득은 집단재배에서 24,302원이였고 개별재배에서는 20,168원으로 집단재배에서 10a당 4,134원의 소득증대를 나타내었다. 본 연구에서 수도집단재배는 새로운 기술의 적용도를 높이고 경영의 합리화를 기하여 안전다수확으로 개개 농가의 소득증대에 기여하였을 뿐만아니라 농민에게 새 기술의 적용이 유익했다는 실증을 보여 줌으로서 농민 스스로의 생산과정에 파급적이며 영속적인 변화를 촉진시킬것이라는 또 하나의 결론을 얻었다.

  • PDF

R&D 투자 촉진을 위한 재정지원정책의 효과분석 (The Effectiveness of Fiscal Policies for R&D Investment)

  • 송종국;김혁준
    • 기술혁신연구
    • /
    • 제17권1호
    • /
    • pp.1-48
    • /
    • 2009
  • 최근 외환위기 이후 기업 R&D 투자의 실질증가율이 외환위기 이전의 절반에 가까운 평균 약 7.1%로 떨어지고 있으며, 대기업에 비해 중소기업에 대한 정부의 R&D 투자 지원이 상대적으로 유리한 데도 중소기업의 R&D 투자 비중은 줄어들고 있다. 또한 1990년대 중반부터 상위 3개 기업을 제외한 대기업 R&D 투자는 증가하지 않고 있어 대기업 간의 R&D 투자 양극화 현상이 나타나고 있다. 이러한 기업의 R&D 투자 현상의 원인이 무엇인지 분석해 볼 필요가 있다. 또한 정부의 R&D 직접 보조금 정책이나 조세지원 정책의 당위성에 대해서 이론적으로나 현실적으로 그 필요성이 인정되더라도 정책의 효율성에 대해서는 검증해 보아야 할 것이다. 본 연구에서는 우리 정부가 가장 보편적으로 활용하고 있는 R&D 보조금 지원제도와 조세지원제도가 과연 효과가 있는지를 실증 분석을 통해 검증해 보려고 한다. 특히 우리나라의 재정지원제도는 대기업과 중소기업 간에 차별적으로 적용되고 있기 때문에 기업 규모에 따른 정책 효과를 구분하여 분석한다. 본 연구의 실증 분석에 이용한 개별 기업의 R&D 데이터는 2002년에서 2005년까지 기업의 연구개발 활동에 대해 서베이 한 "과학기술연구개발활동조사보고"의 기업별 원시 패널 데이터 중에서 활용한 불균형(unbalanced) 패널 데이터이다. 각 기업의 보조금과 관련한 데이터는 "과학기술연구개발활동조사보고"의 서베이 데이터를 사용했으며, 조세지원을 나타내는 사용자 비용에 관한 데이터는 이론적 모형에서 도출하였다. 본 연구의 패널 데이터 분석은 고정효과 모형을 대기업, 중소기업 및 모든 기업에 각각 적용했다. 본 연구의 실증 분석 결과는 다음과 같다. 정부의 직접 보조금 지원은 대기업의 경우 R&D 투자를 늘리는 유인효과(crow이ng-in effect)를 보인데 반해, 중소기업은 R&D 투자를 줄이는 구축효과(crowding-out effect)가 나타났다. 그러나 대기업이나 중소기업 모두 정부의 보조금 지원정책에 대한 반응이 매우 비탄력적으로 추정되었기 때문에 R&D 보조금 지원정책이 기업의 R&D 투자에 미치는 영향은 매우 낮은 것으로 판단된다. 정부의 R&D 조세지원은 대기업과 중소기업의 R&D 투자를 유인하는 것으로 분석되었으며, 특히 중소기업보다 대기업의 R&D 촉진에 더 효과적인 것으로 나타났다. 조세지원으로 사용자 비용이 1% 감소하면 대기업은 R&D 투자를 0.99% 증가시키고, 중소기업은 0.054% 증가시키는 것으로 추정되었다. 본 연구의 분석 결과에서 시사하는 정부의 R&D 재정지원제도의 개선 방향은 다음과 같이 요약할 수 있다. 정부의 R&D 보조금은 기업의 R&D 투자를 구축하지 않도록 기업과 중복되지 않는 기초연구와 공공기술 지원에 국한해야 하며, 중소기업에 대해서는 R&D 인프라 구축과 기술정보지원 등 R&D 서버스(extension service) 지원에 초점을 두어야 할 것이다. 대기업에 대한 R&D 조세지원은 한시적으로 강화할 필요가 있다. 본 연구는 4개 연도의 기업 패널 데이터를 활용하였는데, 앞으로 정책의 효과를 장기간에 걸쳐 분석할 수 있는 거시 시계열 데이터를 활용한 분석의 보완이 필요하다. 또한 기업의 R&D 투자 촉진 외에도 일반 투자나 기타 목적을 위해 시행되고 있는 정부의 재정 정책들과의 대체 혹은 보완 관계의 여부를 검증해 볼 필요가 있다. 특히 중소기업의 시설투자 세액 공제와 R&D 투자 세액공제 제도의 혜택은 단기투자와 장기투자를 선택해야 하는 기업의 의사 결정에 영향을 줄 수 있다.

  • PDF

광주시(光州市) 의료시설(醫療施設)의 입지(立地)와 주민(住民)의 효율적(效率的) 이용(利用) (The Location of Medical Facilities and Its Inhabitants' Efficient Utilization in Kwangju City)

  • 전경숙
    • 한국지역지리학회지
    • /
    • 제3권2호
    • /
    • pp.163-193
    • /
    • 1997
  • 복지사회를 지향하는 오늘날, 건강 중진에 직접 관계되는 의료시설의 접근성 문제는 주요 과제이다. 특히 삶의 질이라는 측면에서 질병의 치료 외에 건강진단, 예방과 회복, 요양 및 응급서비스의 비중이 커지고, 인구의 노령화 현상이 진전되면서 의료시설의 효율적인 입지가 주 관심사로 대두되고 있다. 의료시설은 주민의 생존과 직접 관계되는 기본적이고도 필수적인 중심시설로, 지역 주민은 균등한 혜택을 받을 수 있어야 한다. 이를 실현시키기 위해서는 기본적으로는 효율성과 평등성을 기반으로 1차 진료기관이 균등 분포해야 한다. 이에 본 연구에서는, 광주시를 사례지역으로 선정하여 의료시설의 입지와 그에 대한 주민의 효율적 이용에 관하여 분석하였다. 분석에 있어서는 통계자료와 기존의 연구 성과 외에 설문 및 현지조사 자료를 기반으로 시설 측면과 이용자 측면을 동시에 고찰하였다. 우선 의료 환경의 변화 및 의료시설의 변화 과정을 고찰하고, 이어서 의료시설의 유형별 입지 특성과 주민의 분포 특성을 고려한 지역별 의료수준을 분석하였다. 그리고 유형별 의료시설의 이용행태와 그 요인을 구명한 후, 마지막으로 장래 이용 유형의 예측과 문제지역의 추출, 나아가서는 시설의 합리적인 입지와 경영 방향을 제시하였다. 본 연구 결과는, 앞으로 신설될 의료시설의 적정 입지에 관한 기본 자료로서는 물론 지역 주민의 불평등성 해소라는 응용적 측면에서 의의를 지닌다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF