• Title/Summary/Keyword: Developing Measurement

Search Result 995, Processing Time 0.037 seconds

The Compensation of Machine Vision Image Distortion

  • Chung, Yi-Chan;Hsu, Yau-Wen;Lin, Yu-Tang;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • v.5 no.1
    • /
    • pp.68-84
    • /
    • 2004
  • The measured values of a same object should remain constant regardless of the object's position in the image. In other words, its measured values should not vary as its position in the image changes. However, lens' image distortion, heterogeneous light source, varied angle between the measuring apparatus and the object, and different surroundings where the testing is set up will all cause variation in the measurement of the object when the object's position in the image changes. This research attempts to compensate the machine vision image distortion caused by the object's position in the image by developing the compensation table. The compensation is accomplished by facilitating users to obtain the correcting object and serves the objective of improving the precision of measurement.

System development for the wear measurement offend mill on the machine (엔드밀의 마멸 측정을 위한 기상계측 시스템 개발)

  • 김전하;문덕규;강명창;김정석;김기태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.59-64
    • /
    • 2002
  • Recently the applications of high speed machining are increasing due to the need for high performance and high accuracy machining and machining for difficult-to-cut material. However, the high speed machining also accompanies some problems: the product quality can be degraded due to the tool wear and the product cast can go up due to frequent tool replacements. Therefore, it is necessary to develop a technique of quantitative tool wear measurement to determine the precise timing for tool replacement. In this respect, this study suggests a reliable technique far the reduction of error components by developing a system using a CCD camera and an exclusive jig to be able to precisely measure the size of tool wear in flat end mill for high speed machining.

  • PDF

Automation measurement of a 3D scanner using a robot simulator (로봇시뮬레이터를 이용한 3 차원 스캐너의 측정 자동화)

  • 유희욱;장평수;장민호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.836-839
    • /
    • 2004
  • Qualitative elevation of products is very important Part. A business racking us brains to find for qualitative elevation of products. Recently, measurement accuracy of a non-contact 3D scanner has been rapidly improving. As a result, the number application cases of non-contact 3D scanners are increasing. A non-contact 3D scanner is capable of measuring a curved surface rapidly and has high resolution. It is more affordable and potable than the CMMs, It is therefore expected to be applied more frequently in more diverse industries. Automating the measuring process using a non-contact 3D scanner and developing a technology, which allows a user to measure easily, will eventually improve the quality of products. As their inspection and analysis processes improve.

  • PDF

Effects of the Powder Agglomeration on Vibrating Minimum Ignition Energy Measurement System for Powder (진동형 분진 최소착화에너지측정장치에서 분진 응집현상이 미치는 영향)

  • ;;;;;;M. Yamaguma;T. Kodama;W.L.Cheung
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.48-53
    • /
    • 1999
  • It is widely recognized that Hartmann tube for measuring the minimum ignition energy(MIE) of powder. But It requires long time and operational skills for measuring. As a variety of new fine powders are being produced day by day in industry, Japen has been developing a measurement system which employs a new method to create a dust/air mixture in a miniature combustion box. In this system, by vibration, the powder is successively fed downward through a hopper made up of metal mesh, and then it is formed into a thin, certain-like, dust/air mixture. With this new apparatus, three types of powder-Lycopodium, Anthraquinone, and Polyacry-lonitrile-were tested and the data of MIE were compared with those of a conventional apparatus (the Hartmann tube). Two of them agreed satisfactory, but the other, Anthraquinone, showed quite different values. It is guessed that the agglomerations of the powder particles appear because of particle shapes, static-charge and humidity.

  • PDF

The Development fo Occupational Stress Measurement Tool for Psychiatric Nurses (정신과 간호사의 업무 스트레스 측정을 위한 도구 개발 연구)

  • Bai, Jeong-Yee
    • The Korean Nurse
    • /
    • v.28 no.1
    • /
    • pp.77-88
    • /
    • 1989
  • The purpose of this study is to propose the baseline data for -developing the occupational stress measurement tool for Psychiatric nurses Working in the hospital. 135 staff nurses in psychiatric unit of 11. hospital were participated during the period from August 1 to August 20, 1988. Though the pretest and literature review a questionnaire was coristructed with 88 stressors which were experienced by the psychiatric nurses in the hospital. Subjects were given instruction to rate 1~6 likert type scale according to the level of stress experienced by each stressor described. Reliability of the tool was tested by Cronbach's Alpha and the reasult was ${\alpha}=0.94871$. Factor analysis was applied to organize 88 items together: As the result, 14 factors were obtained. The factors were; 1) Administration problem 2) Work overload 3) Role conflict as a profession 4) Lack of professional knowledge and skill 5) Conflict with nurses 6) Conflict with other health teams 7) Conflict in nurse-clint relationship 8) Conflict with supervisor 9) Conflict with suborinate 10) Low reward 11) Scheduling probrem 12) Inappropriate physical environment 13) Staff inadequate 14) Inadequate of equipment.

  • PDF

The Construction of Safety Measurement Equipment of Grounding Electrode for Distribution System (배전용 접지전극의 안전성 분석 장치 구성)

  • Kang, Moon-Ho;Park, Young-Keun;Jang, Sang-Ok;Won, Yoon-Chan;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.218-221
    • /
    • 2005
  • Grounding electrodes as discharge paths to the earth are normally used to ensure the safety of human body and facilities from the over-voltages in distribution power system, and each grounding mode has a prescribed ground resistance value respectively which is applied by the utilities. As the various electrodes for distribution power system are recently developing to improve the performance of them and resolve the problem of space restriction, it is necessary to measure and investigate the safety of human body of developed electrodes. Therefore, in this paper, we provide briefly a technical comparison of two standards, i.e. IEEE Std 80 and the IEC 479-1, and describe the configuration of safety measurement system which can measure the step voltage and the touch voltage of grounding electrodes based on IEEE Std 80.

  • PDF

Developing End-User Oriented Quality Dimensions for BcN Service (사용자 중심의 광대역통합망 서비스 품질척도 연구)

  • Eun, Hyun-Ji;Kim, Seong-Cheol
    • Korean Management Science Review
    • /
    • v.23 no.3
    • /
    • pp.119-132
    • /
    • 2006
  • Since the guaranteed service quality(QoS) is spotlighted as a strategic competitive tool to Broadband Convergence Network(BcN) service providers, many scholars have dealt with QoS issues in the BcN environment. However, just a few researchers focus on end-users and most are lean toward service providers or technology itself. In this paper, therefore, we investigated how end-users could measure service quality in the BcN environment, and moreover, proposed the end-user oriented measurement guideline for BcN QoS. Through literature review and two surveys, four QoS dimensions and nineteen measurement items were derived from end-user's perspective. proposed QoS dimension and items would be utilized as meaningful tools for future BcN service.

Measurement of Autoignition Temperature of o-Xylene+n-pentanol System (오토자일렌과 노말펜탄올 계의 최소자연발화온도 측정)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.66-72
    • /
    • 2006
  • An accurate knowledge of the AITs(autoignition temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The measurement of AITs are dependent upon many factors, namely initial temperature, pressure, vessel size, fuel/air stoichiometry, catalyst, concentration of vapor, ignition delay time. The values of the AITs used process safety are normally the lowest reported, to provide the greatest margin of sefety. This study measured the AITs of o-xylene+n-pentanol system from ignition delay time by using ASTM E659-78 apparatus. The experimental AITs of o-xylene and n-pentanol were $480^{\circ}C\;and\;285^{\circ}C$, respectively. The experiment AITs of o-xylene+n-pentanol system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation).

Running Characteristics for On-Line Test of Railway Vehicle

  • Han, Young-Jae;Kim, Seog-Won;Seo, Sung-Il;Mok, Jin-Yong;Lee, Su-Gil;Kim, Young-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1347-1350
    • /
    • 2005
  • Recently, as the road capacity reaches a limit and environmental problems become serious, there exists a gradual increasing need for railway vehicles that are environment-friendly, punctual, reliable and safe. Accordingly, in addition to conventional railroad vehicles, lots of vehicles are being newly developed. Using the developed installed measurement system, the performance characteristics of railway vehicle could be monitored precisely. After recording the input real time data of each signal from railway vehicle to the network line, we could acquire the needed information through post processing program. We could verify the running performances of railway vehicle using this system. As a result, many latent defects have been found and corrected in the prototype train. The measurement systems have contributed to dramatic reduction of the developing period.

  • PDF

A New Algorithm Design for the Real-time Electrochemical Impedance Monitoring System

  • Chang, Byoung-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.154-158
    • /
    • 2012
  • It is generally known that electrochemical impedance spectroscopy is a powerful technique and its real-time application has been demanded for prompt observations on instantaneous electrochemical changes. Nevertheless, long measurement time and laborious analysis procedures have hindered development of it. Solving the problems, here I report of a new algorithm design for development of a real-time electrochemical impedance monitoring system, which potentially provides a guideline in developing monitoring systems of electric vehicles batteries and other electrochemical power plants. The significant progress in this report is employment of the parallel processing protocol which connects independent sub functions to successfully operate with avoiding mutual interruptions. Therefore, all the processes required to monitor electrochemical impedance changes in realtime are properly operated. To realize the conceptual scheme, a Labview program was coded with sub functions units which conduct their processes individually and only data are transferred between them through the parallel pipelines. Finally, measured impedance spectra and analysis results are displayed, which are synchronized according to the time of change.