• 제목/요약/키워드: Determination of chlorine

검색결과 35건 처리시간 0.025초

전기화학적 방법의 TRC(Total residual chlorine) 측정 연구(I: Au전극 이용) (The Determination of TRC using an Electrochemical Method (I: Au electrode))

  • 이준철;박대원
    • 한국물환경학회지
    • /
    • 제30권3호
    • /
    • pp.298-303
    • /
    • 2014
  • We measured by electrochemical method for TRC (total residual chlorine) in ocean. From the results of Au electrode used for working electrode through cyclic voltammetry test, we obtained charge in voltage ranged from 0.0V-1.0V, and analyzed correlations of charge for TRC. Reduction peak TRC was investigated to be approximately 0.65 V vs. Ag/AgCl, and in the case that salt concentrations and temperatures in ocean appeared different, charge was analyzed for being different in the same TRC. However, in the case that each condition was constant, charge was measured at highly correlations for TRC.

Real-Time Detection of Residual Free Chlorine and pH in Water Using a Microchannel Device

  • Kim, Sam-Hwan;Choi, Ju-Chan;Lee, June-Kyoo;Kong, Seong-Ho
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.368-374
    • /
    • 2011
  • A microfluidic device for real-time monitoring of residual free chlorine and pH in water based on optical absorption is proposed. The device consists of a serpentine micromixer for mixing samples with a reagent, and a photodiode and light emitting diode(LED) for the detection of light absorbance at specific wavelengths, determined for specific reagent combinations. Spectral analyses of the samples mixed with N, N'-diethyl-p-phenylenediamine(DPD) reagent for chlorine determination and bromothymol blue(BTB) for pH measurement are performed, and the wavelengths providing the most useful linear changes in absorbance with chlorine concentration and pH are determined and used to select the combination of LED and photodiode wavelengths for each analyte. In tests using standard solutions, the device is shown to give highly reproducible results, demonstrating the feasibility of the device for the inexpensive and continuous monitoring of water quality parameters with very low reagent consumption.

전기화학적 방법의 TRC(Total residual chlorine) 측정 연구(II: Pt전극 이용) (The Determination of TRC using an Electrochemical Method (II: Pt electrode))

  • 이준철;박대원
    • 한국물환경학회지
    • /
    • 제30권3호
    • /
    • pp.304-310
    • /
    • 2014
  • The conventional methods for total residual chlorine such as iodometry and DPD colorimetric can cause secondary pollution due to additional agents, also have a wide error range. As for alternative, electrochemical method can measure TRC(Total residual chlorine), and is not required as additional agents, also very suitable for using the fields of ballast water because test time is relatively fast. Therefore, this study was investigated for changing charge by agitation, salt concentration, and temperature change. Charge showed differences based on changes of reduction peak with or without agitation. In contrast, TRC and charge were well correlated in constant agitation speed. As TRC and charge were analyzed with high correlations in constant salinity and temperature of ocean, thereby conductivity was firstly measured, and charge had high correlation for TRC in spite of changing salinity and temperature Pt electrode revealed high reliability ($r^2=0.960$) because it was rarely effected by TRC, On the other hand, Au electrode appeared inadequate ($r^2=0.767$) to use sensor in less than 1.0 ppm of TRC. For high accuracy and detection of TRC, Pt and Au electrodes for test time were, respectively, 14 and 22 seconds. As a result, Pt electrode was more valuable than Au electrode in terms of response time.

와이퍼 블레이드 고무의 표면 처리에 따른 특성 (The Characteristics of Wiper Blade Rubber with Surface Treatments)

  • 노승백;임미애;박진규;손전익
    • Elastomers and Composites
    • /
    • 제33권1호
    • /
    • pp.27-36
    • /
    • 1998
  • The surface of wiper blade(W/B) rubber was chlorinated by chemical treatment method using the hydrochloric acid(HCI) and sodium hypochlorite(NaOCl). From the results of contact angle measurement, friction coefficient measurement, and ATR-IR spectra, the surface characteristics of chlorinated W/B rubber with time of chlorination were studied. Contact angles for W/B rubber with increasing time of chlorination and chlorine concentration were measured for the water and ethylene glycol. From the results, contact angle fell rapidly with increasing time of chlorination and chlorine concentration, reaching a constant value after about 10min. And the wettability of W/B rubber surface by means of chlorination has been improved. For an unchlorinated W/B rubber, the friction coefficient with time of chlorination decreased from 1.27 to 0.20~0.23 on full chlorination. As the results it was considered that abrasion resistance of W/B rubber surface has been also improved. The values of pH and $Cl^-$ ion concentration in a chlorine treatment solution decreased as the extent of chlorination of W/B rubber surface increased. From the results of ATR-IR spectra, it was observed that C=C double band of W/B rubber surface transformed into C-Cl band, but quantitative determination of the extent of chlorination was not feasible because of the complexity of chlorination reactions.

  • PDF

정수장내 염소요구량 자동결정시스템 개발 (Development of Automatic Decision System for Chlorination Demand in Water Treatment Plant)

  • 오석영
    • 대한기계학회논문집B
    • /
    • 제26권6호
    • /
    • pp.757-764
    • /
    • 2002
  • Chlorination dosage in water treatment plant of field is determined by chlorination demand experiment through two or three hours after raw water was sampled in inflow. It is impossible to continuously control for real time because the sampled water is adapted chlorination dosage after water treatment process had been proceeded. Therefore in this study, we will design informal chlorination demand system, this designed system will be experimented as to water quality and accuracy of control in various conditions. Throughout these experimental results, we will revise the system and the revised system is enable to optimal control of chlorination dosage. Finally, we have developed chlorination demand system, which can automatically determination of chlorination dosage to be determined according to variety of raw water quality inflow in water treatment plant.

Ultrahigh Vacuum Study for the Model Systems of Ziegler-Natta Catalyst

  • 이창섭
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권7호
    • /
    • pp.661-666
    • /
    • 1995
  • The surface structure of the adsorption site for the identification of active sites involved in the Ziegler-Natta catalyst was studied by surface science techniques. As an example of a real catalyst, TiCl3 single crystals were prepared in a gradient furnace designed for this study and characterized by Auger Electron Spectroscopy (AES) and Low Energy Electron Diffraction (LEED) under ultrahigh vacuum condition. The chlorine covered Ti (0001) surface was employed as a model catalyst for the study of Ziegler-Natta catalyst. The diffuse LEED (DLEED) technique for the surface structural determination was applied to this disordered chlorine adsorbed on Ti (0001) surface. The diffuse scattering intensities were measured by a TV-computer method using a low light level video camera. From an analysis of two catalyst systems, the informations for the surface structure of the model catalyst surfaces were derived.

근적외선 분광분석법을 이용한 판상엽 화학성분 평가 (Evaluation of Chemical Composition in Reconstituted Tobacco Leaf using Near Infrared Spectroscopy)

  • 한영림;한정호;이호근;제병권;강광원;이기열;어성제
    • 한국연초학회지
    • /
    • 제35권1호
    • /
    • pp.1-6
    • /
    • 2013
  • Near InfraRed Spectroscopy(NIRS) is a quick and accurate analytical method to measure multiple components in tobacco manufacturing process. This study was carried out to develop calibration equation of near infrared spectroscopy for the prediction of the amount of chemical components and hot water solubles(HWS) of reconstituted tobacco leaf. Calibration samples of reconstituted tobacco leaf were collected from every lot produced during one year. The calibration equation was formulated as modified partial least square regression method (MPLS) by analyzing laboratory actual values and mathematically pre-treated spectra. The accuracy of the acquired equation was confirmed with the standard error of prediction(SEP) of chemical components in reconstituted tobacco leaf samples, indicated as coefficient of determination($R^2$) and prediction error of sample unacquainted, followed by the verification of model equation of laboratory actual values and these predicted results. As a result of monitoring, the standard error of prediction(SEP) were 0.25 % for total sugar, 0.03 % for nicotine, 0.03 % for chlorine, 0.16 % for nitrate, and 0.38 % for hot water solubles. The coefficient of determination($R^2$) were 0.98 for total sugar, 0.97 for nicotine, 0.96 for chlorine, 0.98 for nitrate and 0.92 for hot water solubles. Therefore, the NIRS calibration equation can be applicable and reliable for determination of chemical components of reconstituted tobacco leaf, and NIRS analytical method could be used as a rapid and accurate quality control method.

배급수계통에서 잔류염소 감소 특성 및 적용연구 (Modeling and Application of Chlorine Bulk Decay in Drinking Water Distribution System)

  • 안재찬;박창민;구자용
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.487-496
    • /
    • 2005
  • Chlorine bulk decay tests were carried out by bottle test under controlled conditions in a laboratory. Experiments were performed at different temperatures: $5^{\circ}C$, $15^{\circ}C$, $25^{\circ}C$, and the water temperatures when samples were taken from the effluent just before entering to its distribution system. 38 bulk tests were performed for water of Al (water treatment plant), 4 bulk tests for A2 (large service reservoir), and A3(pumping station). Residual chlorine concentrations in the amber bottles were measured over time till about 100 hours and bulk decay coefficients were evaluated by assuming first-order, parallel first-order, second-order. and $n^{th}-order$ reaction. The $n^{th}-order$ coefficients were obtained using Fourth-order Runge-Kutta Method. A good-fit by the average coefficient of determination ($R^2$) was first-order ($R^2=0.90$) < parallel first-order ($R^2{_{fast}}=0.92$, $R^2{_{slow}}=0.95$) < second-order ($R^2=0.95$) < $n^{th}-order$ ($R^2=0.99$). But if fast reaction of parallel first-order bulk decay were applied to the effluent of large service reservoir with ca. 20 hours of travel time and slow reaction in the water distribution system following the first 20 hours, parallel first-order bulk decay would be best and easy for application of water quality modeling technique.

배급수계통에서 잔류염소 및 THMs 분포 예측에 관한 연구 (Modeling Residual Chlorine and THMs in Water Distribution System)

  • 안재찬;이수원;노방식;최영준;최재호;김효일;박태준;박창민;박현;구자용
    • 대한환경공학회지
    • /
    • 제29권6호
    • /
    • pp.706-714
    • /
    • 2007
  • 본 연구에서는 배급수계통에서 잔류염소와 THMs의 분포를 예측하는 방안을 제시하였다. 잔류염소와 THMs의 등의 수질변화에 대해 현장조사를 실시하였고, 수체와 관벽에 대한 잔류염소 감소계수와 THMs의 생성계수를 산출하여 관망해석에 의한 수질모델링에 적용하였다. 병실험을 통해 잔류염소 병렬 1차 수체 반응계수를 구하고, 5개 관벽 감소 모델을 비교 평가하여 1차 관벽 감소계수 산출하고 적용했을 때 잔류염소 현장 측정값과 관망 수질모델링에 의한 예측간의 평균절대오차 및 평균제곱근오차가 각각 0.03, 0.037 mg/L로 가장 작았다. 또한 병실험에 의한 THMs생성량을 비선형 회귀분석으로 1차 생성계수를 구하고 현장 측정값과 비교하였다. 그 결과, 9월의 현장 측정값과 예측값의 결정계수 $R^2$는 0.98, 11월에는 0.82로 예측이 가능하였다.

Predictive Modeling for the Growth of Salmonella Enterica Serovar Typhimurium on Lettuce Washed with Combined Chlorine and Ultrasound During Storage

  • Park, Shin Young;Zhang, Cheng Yi;Ha, Sang-Do
    • 한국식품위생안전성학회지
    • /
    • 제34권4호
    • /
    • pp.374-379
    • /
    • 2019
  • 본 연구에서는 대표적인 신선 잎채소류인 상추의 세척 단계에서 초음파 (37 kHz) 와 염소 (100~300 ppm) 의 병용처리 후 냉장 ~ 실온저장 ($10{\sim}25^{\circ}C$)에 따른 이 식품 중의 Salmonella Typhimurium의 성장예측모델을 개발하였다. 1 차 모델 개발을 위해 Gompertz 방정식을 활용하여 각기 다른 실험 조건에서의 S. Typhimurium의 생육도 (SGR 과 LT)를 조사했다. 본 방정식에 의한 1 차 모델 개발시 $R^2$가 0.92 이상으로 우수하게 나타났으며 저장온도가 낮을수록 초음파에 사용된 염소의 농도가 높을수록 SGR 값은 감소하였고 LT 값은 증가하였다. 이를 바탕으로 2 차 polynomial 모델을 개발하여 다양한 통계적 지표 ($R^2$, MSE, $A_f$$B_f$)를 통해 분석한 결과 개발된 모델의 적합성을 확인할 수 있었다. 따라서 개발된 모델이 초음파와 염소의 병용 세척에 따른 저장 중 상추에 대한 S. Typhimurium의 성장예측모델로 사용 가능하다고 판단되어지며, 신선 잎채소류에서의 식중독을 예방하고 미생물학적 위생관리기준을 설정하는데 기초자료로 활용될 수 있을 것으로 사료된다.