• Title/Summary/Keyword: Deterioration facilities

Search Result 255, Processing Time 0.034 seconds

Evaluation of Influence Factors for Determination of Proper Backwashing Time of Biological Activated Carbon (BAC) Process in Drinking Water Treatment Process (정수처리용 활성탄 공정의 적정 역세척 시점 선정을 위한 영향인자들 평가)

  • Kim, Sang-Goo;Park, Hong-Gi;Son, Hee-Jong;Yoom, Hoon-Sik;Ryu, Dong-Choon
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1551-1558
    • /
    • 2015
  • In Korea, many drinking water treatment plants (DWTPs) have introduced and are going to introduce biological activated carbon (BAC) process to treated dissolved organic matter (DOM) in water which are difficult to control by conventional water treatment processes. Even though more decade have passed since introduced BAC in Korea, most of BAC operating method was followed to the modified sand filter operating manuals. In case of BAC backwashing, many DWTPs set the periods of backwashing about 3~5 days. In this study, we have collected data to set the proper BAC backwashing periods from both pilot-plant and real DWTPs. We had measured heterotrophic plate count (HPC), turbidity, water temperature, dissolved organic carbon (DOC) and headloss from just after backwashing to the next backwashing time for two years. Considering water quality factors, the BAC run time from backwashing to the next backwashing could extend more 30 days without water quality deterioration if the head loss do not reach the limited level which depends on each BAC facilities' condition. It means the BAC treated water could be saved in the proportion of extended the backwashing period to the existing backwashing period.

A study on the Development of Low-loss Type Mold Autotransformers (저손실형 몰드 단권변압기 개발)

  • Lee, Jong-Su;Shin, Myung-Ho;Mun, Byung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.92-94
    • /
    • 2003
  • The autotransformer currently used on the electric railway system is made of class A insulation material and uses the paper insulation method. As a power converter supplying power to the trolley wire, the autotransformer is one of critical equipment in the railway system. In the autotransformer, load irregularly changes and overload often occurs. These cause overheating of the autotransformer and facilitate deterioration of the autotransformer resulting in burnout accidents due to insulation breakdown. Also, the current autotransformer has poor insolation and short-circuit strength which often badly affect the service life of the transformer, and needs to improve its quality urgently. To overcome one of existing shortcomings of the mold transformer, manufacturers use epoxy resins that have superior flame retardancy to get rid of fro and explosion possibilities during accidents. Currently, new mold transformers are used in indoor distribution facilities with fire-fighting equipments. Coils molded in epoxy resins do not have their insulation performance compromised by humidity, dust, etc enabling easy inspection and maintenance. Comparing to the oil immersed transformer, the mold transformer does not have any concern about environmental pollutions by oil leak or replacement Therefore, to reduce breakdowns and improve reliability of the autotransformer, it is necessary to develop a new mold autotransformer with low loss suitable for our environment to suppress breakdowns of the autotransformer and improve the reliability. This study is about development of a low-loss mold autotransformer necessitated by reasons mentioned earlier.

  • PDF

The Case of CM as Applied to the Pre Design Phase - Focused on the Case of YongJu New Tobacco Manufacturing Plant - (설계 전 단계에서의 CM 적용 사례 - 영주 신 제조창 CM 사례를 중심으로 -)

  • Park Yong-Jun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.19-26
    • /
    • 2003
  • In the face of the deterioration of tobacco manufacturing plant, we've got the plan for now manufacturing factory for the competitiveness, modernization, rationalization and environment. To achieve the goals, it was necessary to plan and investigate in the early stage of project. Consequently. We determined to introduce the CM in the early stage. We Performed the whole phase of CM services front the pre design phase services like feasibility analysis of site and building, plant master plan, selection of manufacturing facilities and drawing up the RFP, to maintenance management phase after the completion of a construction work. Contrary to the another CM projects, YongJu New Tobacco Manufacturing Plant CM organized the CM team with expert in field before the design development. This study analyze and evaluate the CM services of YongJu project which performed on the pre design phase. The purpose of this study is to emphasize the importance of pre design phase CM and support that CM services will start from the pre design phase.

  • PDF

A Study on the Functional Area Composition and Correlation Factors of Elderly Care Floor in Nursing Home (노인요양시설 요양층의 기능별 면적구성과 상관요인에 관한 연구)

  • Yoon, So-Hee;Kim, Suk-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.3
    • /
    • pp.156-164
    • /
    • 2015
  • Nursing Homes do not have a defined standard in the space area nor does it have a detailed standard facility requirement by law. This can possibly lead to the deterioration of the facility and the system. This directly affects the medical treatment space area within the nursing home. The medical treatment area provides medical treatment to seniors and this is where the seniors get most of their daily services. Therefore, this is research is about the study of the space area of the medical center and the ratio trend of the space area for the medical treatment facility located in senior nursing homes. Ten facilities have been selected in this study to analyze the correlation factors between space area and its trends. The analysis performed includes the conditions relating to the area and what affects the center. We have followed up with a proposal for improvement of the facility and area configuration for the medical treatment facility. Based on the analysis, the following conclusion can be made: First, the senior welfare centers are mostly used as a residence purpose followed a temporary stay of residence facility for the seniors. Second, research indicates that the bigger the facility, nursing and public functions took a larger portion of the space area compared to other services within the senior welfare centers. Third, the study shows the management space area took up about 1%~6% of the entire medical center within the nursing home which is a narrow space area because of the integrated management. Fourth, analysis based on the trend in the time-series indicate after the adoption of the system, there is a continued decline in the space area of nursing, management and public areas. Lastly, since before and after 2008, the space area composition of the nursing facility shows a continuous decline in our study. We can safely conclude that the revised senior welfare act's construction plan has an effect in the facility and is effectively working to meet its requirement. Therefore, the revision of the law is required to reflect the social needs of the residents.

Prisoners' Perception of Tobacco Use and Cessation in Chhatisgarh, India - The Truth from Behind the Bars

  • Tiwari, Ram Vinod;Megalamanegowdru, Jayachandra;Parakh, Abhinav;Gupta, Anjali;Gowdruviswanathan, Shailarani;Nagarajshetty, Praveen Malavalli
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.1
    • /
    • pp.413-417
    • /
    • 2014
  • Background: Prisoners represent a population group that is disadvantaged, socially deprived and underprivileged, needing particular attention with regard to provision of necessary oral health care, health promotion and motivation and tobacco cessation. Considering the situation in prisons, smoking and tobacco chewing are burning issues related to health deterioration and economic loss that seem to be overlooked by the public health sectors. Aim: To assess prisoners' perception of tobacco use and cessation in Chhatisgarh, India. Materials and Methods: A pre-tested, close ended questionnaire was administered in the form of extensive face to face interviews, to assess perceptions regarding tobacco use and cessation in the central jail of Durg District of Chhattisgarh state, India. Results: Prevalence of tobacco usage amongst the prisoners was found to be 61%. Some 27% reported smoking, 44% used tobacco in the chewable form and 29% indulged in consuming tobacco in both forms i.e. smoked as well as chewed. Results suggest several recommendations for policy relevance such as provision of a prison dentist, a tobacco cessation counseling program and targeted eradication of oral cancer by educating the prisoners. Conclusions: Health is a fundamental human "right of everyone to the enjoyment of the highest attainable standard of physical and mental well-being". This applies to prisoners just as it does to every other human being. The alarming findings in the study suggest the need for dental treatment facilities and tobacco cessation counseling in prisons.

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

TRIZ-based Improvement of Glass Thermal Deformation in OLED Deposition Process (트리즈 기반 OLED 증착 공정의 글래스 열 변형 개선)

  • Lee, Woo-Sung;Choi, Jin Young
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.1
    • /
    • pp.114-123
    • /
    • 2017
  • The global small and mid-sized display market is changing from thin film transistor-liquid crystal display to organic light emitting diode (OLED). Reflecting these market conditions, the domestic and overseas display panel industry is making great effort to innovate OLED technology and incease productivity. However, current OLED production technology has not been able to satisfy the quality requirement levels by customers, as the market demand for OLED is becoming more and more diversified. In addition, as OLED panel production technology levels to satisfy customers' requirement become higher, product quality problems are persistently generated in OLED deposition process. These problems not only decrease the production yield but also cause a second problem of deteriorating productivity. Based on these observations, in this study, we suggest TRIZ-based improvement of defects caused by glass pixel position deformation, which is one of quality deterioration problems in small and medium OLED deposition process. Specifically, we derive various factors affecting the glass pixel position shift by using cause and effect diagram and identify radical reasons by using XY-matrix. As a result, it is confirmed that glass heat distortion due to the high temperature of the OLED deposition process is the most influential factor in the glass pixel position shift. In order to solve the identified factors, we analyzed the cause and mechanism of glass thermal deformation. We suggest an efficient method to minimize glass thermal deformation by applying the improvement plan of facilities using contradiction matrix in TRIZ. We show that the suggested method can decrease the glass temperature change by about 23% through an experiment.

Service Life Prediction of R.C. Structures Considering Chloride Binding (염화물 고정화를 고려한 철근 콘크리트 구조물의 내구수명 예측)

  • Lee, Chang-Soo;Park, Jong-Hyok;Kim, Young-Ook
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.15-22
    • /
    • 2010
  • Chloride-induced corrosion of steel bars in concrete exposed to marine environments has become one of the major causes of deterioration in many important facilities made of reinforced concrete. A study on chloride penetration in concrete has developed through long period exposure test along seawater, assesment of chloride ion diffusion by electrochemical techniques and so on. However, reasonable and exclusive chloride penetration model considering concrete material properties with mixture, degree of hydration, binding capacity has not been established. Therefore, in this paper, chloride penetration analysis of non-steady state is accomplished with material properties of concrete. Comparing with the results of analysis and chloride ponding test, we could accept the effect of binding capacity on chloride penetration in concrete and these results could be applied to a service life prediction of R.C. structures submerged in seawater. Therefore, there are 20~40% differences of service life to SHRP prediction.

Experimental Application of DAF Hybrid Process to Remove Algae Particles for Conventional Water Treatment Processes and Change of Particle Characteristics (재래식 정수처리공정에서 조류입자 제거를 위한 DAF Hybrid 공정의 실험적 적용과 입자특성 변화)

  • Kwak, Dong-Heui;Yoo, Seung-Joon
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.516-520
    • /
    • 2008
  • There are many water treatment plants built over couple of decade ago in Korea. For most of those plants, they are required a countermeasure to cope with the deterioration caused from the superannuated facilities and the objective materials change of water treatment from inorganic particles like clay to algae particles due to eutrophication of lake and reservoir. A series of field and laboratory experiments was performed to investigate the feasibility of DAF hybrid process and the variation of particle characteristics by applying the additional DAF unit in conventional water treatment processes. On the basis of this experiments, the DAF was effective as an additive process in filtration basin (DAF-CSF combination processes). Using DAF-CSF combination process, the efficiency of stable particle removal can be achieved to produce the safe drinking water.

A Study on leakage monitoring of tunnel linings using the electric resistivity survey (전기비저항탐사를 이용한 터널라이닝 누수조사 연구)

  • Shin, Jong-Ho;Shin, Yong-Seok;Yoon, Jong-Ryeol;Kim, Ho-Jong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.3
    • /
    • pp.257-267
    • /
    • 2008
  • Tunnels acting as drains involve groundwater-related problems such as deterioration of drainage systems or leakage through the linings. Generally initial and minor leakage problems can not be recognized by naked eyes. When the leakage over the linings is noticed, damages to structures and facilities have already occurred and could be considerable. Therefore it is vital to recognize initial leakage as early as possible and provide appropriate measures. Detection of leakage under operation requires installing piezometer. However, that may cause destruction of water proofing sheet which is generally not allowed. In this study electric resistivity method, one of the geophysical surveys, was adopted to detect possible leakage through tunnel linings. Physical lining models were made in the laboratory. The electric response was monitored for varying hydraulic conditions. It is shown that the method is very useful to detect initial leakage and monitor the malfunction of drainage system. Furthermore the method can also be used to check the quality of any repairing works of linings.

  • PDF