• Title/Summary/Keyword: Deteriorated Specimen

Search Result 58, Processing Time 0.024 seconds

Flexual Retrofitted Effect on Structurally Damaged Reinforced Concrete Beam Strengthened with Steel Plate (구조적 손상을 입은 철근 콘크리트 보의 강판 휨보강 효과)

  • Lim, Tae-Geoun;Kim, Sung-Yong;Shin, Chang-Hoon;Kim, Kyu-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.201-210
    • /
    • 2000
  • The Rehabilitation and repair of structurally deteriorated reinforced concrete structure become more necessary as time goes by. The goal of this study is that provide the data about flexural retrofitted effect of RC beam strengthened by Steel Plate. In order to provide the data, 6 specimens were manufactured and divided with standard specimen and damaged degree A, B, C. Division of damaged A, B, C is based on deflection and degree of crack. In the determination of deflection and degree of crack, we loaded standard specimen to failure under two-point bending to find yielding load and failure load, and then we found deflections and degree of crack that correspond to 75%, 100%, 105% of the yielding load of standard specimen respectively. When we are compared with standard specimen and strengthened specimens, we founded from the experimental results that flexural capacity of structurally damaged beam strengthened by Steel Plate incremented highly, ductility was decreased, and energy absorbtion capacity was almost same.

  • PDF

The Patch Attachment Effect for Bending Behavior on the CF/Aramid Composites with Seawater Aging and Hole Damage (해수 열화 및 원공 손상 CF/Aramid 복합재의 패치 부착이 굽힘거동에 미치는 영향)

  • Woo Deok Kwon;Oh Heon Kwon;Yu Seong Yun
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.20-26
    • /
    • 2023
  • Fiber-reinforced composite materials with carbon, glass, and aramid fibers are widely applied to industrial field structures due to their excellent properties. However, carbon fibers are vulnerable to external impacts, whereas aramid fibers degrade when exposed to water. This study evaluated carbon/aramid fiber composites degraded and damaged by high-temperature saline environments using acoustic emission (AE). The test specimen was molded using an autoclave and immersed in seawater at 70 ℃ for 224 days. In order to imitate the damage, a 3-mm-diameter hole was drilled using a diamond drill. Additionally, the specimen with the perforation was repaired by patch attachment processing. Three-point bending was used to conduct the flexural experiment, and an AE sensor with a 150-kHz resonance frequency was attached to evaluate the damage and the effect of patch attachment. AE accumulative counts obtained at the maximum load were 69.2, 67.1, and 91.2 for a high-temperature seawater deteriorated condition, a hole specimen, and a repaired patch specimen, respectively. Furthermore, the maximum amplitude of AE was detected at low values of 28 dB, 31.3 dB, and 30.3 dB.

Characteristic of Chloride ion Diffusion in Mortar According to the Substitution Ratios of the Additive (혼합재 치환율에 따른 모르타르의 염소이온 확산 특성)

  • 양승규;정연식;이웅종;유재상;이종열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.17-22
    • /
    • 2002
  • Chloride ions have a tendency to penetrate into concrete and proceed the corrosion by depassivating rebar surface. Thus the deteriorated concrete is subject to experience severe degrading of durability under marine environment. Physical properties of mortar, such as, compressive strength and penetration depth of chloride ion were investigated. And to investigate the effect of containing SG, FA in mortar, the diffusion coefficient of chloride was measured through an electro - migration test. The diffusion coefficient of chloride was decreased with the increase of replacement ratio of SG compared with plain specimen.

  • PDF

Evaluation of Strengthening Capacity of Axial Member Using Admixture-Modified Mortar (혼화재 첨가 모르터를 이용한 압축부재의 보강성능 평가)

  • 박준명;양동석;박선규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.417-422
    • /
    • 2002
  • Strength and Durability of reinforced concrete exposed at deteriorated environment are decreased by cover spatting and corrosion of reinforcement. The purpose of this paper is to evaluate capacity of strengthening axial member using admixture-modified mortar. To investigate the capacity of strengthened axial member, behavior and strength of strengthening specimens were compared with a monolithic basic specimen. Admixture-modified mortar was prepared with silica fume, zeolite, polymer as cement modifier. From the result of this experiment, strengthening specimens using polymer-modified mortar have apparrent strengthening capacity because of good flexural strength and tensile strength.

  • PDF

An Experimental Study on Flexural Behavior of RC Bridge Deck Strengthened with Carbon Fiber Sheet (RC 교량상판의 휨 성능향상을 위한 탄소섬유 보강방법 연구)

  • 심종성;오흥섭;이승원;김경민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.827-832
    • /
    • 1998
  • Recently, Carbon Fiber Sheets(CFS) have been used for strengthening the deteriorated RC beams and bridge decks because of its resistant capacity of corrosion and easy repairing works. In this study, the static test tare performed on RC bridge decks strengthened with CFS. Test results show that ultimate strength of specimens strengthened with CFS is increased as 15~26% comparing to the control specimen.

  • PDF

Studies on the consolidants and water-repellents of stone cultural properties (석조문화재 발수경화제 시험연구(II))

  • Eom, Doo-Sung;Kim, Sa-Dug;Hong, Jung-Ki;Kang, Dai-Ill;Lee, Myeong-Hui
    • 보존과학연구
    • /
    • s.22
    • /
    • pp.133-154
    • /
    • 2001
  • Stone cultural properties, exposed in natural environment, is deteriorated by many weathering reasons for a long time. It is necessary to treat of consolidation and water-repellent on the surface because of the conservation of stone cultural properties. We was treated the specimen [granite(Hwangdung-suk), sandstone, marble(in JeongSeon)] by synthesis resin of DWR-Ⅲ, SI2121 and fluoropolymer, and tested on the durability, water-repellent, color stability and luster generation etc. In the result of this study, DWR-Ⅲ and fluoropolymer is superior to the waterrepellent, durability of salt and acid rain. SI2121 is superior to the penetration because of lower viscosity, but the water-repellent is inferior to the others. After the treatment of chemicals, the color-variation make an appearance but luster-generation doesn’t. With the passage of time, the color of specimen was got better because of the ‘washing’ phenomenon for ultra-violet, salt etc.

  • PDF

The surface profile of Wire-cut EDMed Surface by Lapping Process (래핑가공에 의한 와이어 방전가공면의 표면형상)

  • 이재명;김원일;왕덕현;이윤경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.956-959
    • /
    • 2001
  • In die and mould industry, major material such as cemented carbide is broadly used for increasing the life time and decreasing the cost. It is also required the development for the skills of wire-cut electrical discharge machining(WEDM), but the WEDMed surface was found to be worst due to the attached components of wire. Precision machining method like lapping is necessary for obtaining high quality surface. The lapping compound such as Al2O3 and SiC and cast iron lap can be used for lapping process. The components of Cu and Zn were found WEDMed surface of the specimen. As the result, the low quality of precision was obtained and the heat damage layer of the specimen was occurred. The value of surface hardness was deteriorated, and therefore finish process was required.

  • PDF

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on less than three hundred bed hospitals (종합병원 진단검사의학과 검사실의 시설 현황 조사 - 300 병상 미만 병원을 중심으로)

  • Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.15-23
    • /
    • 2019
  • Purpose: As the medical laboratories in general hospitals have made an efforts on quality management and employee health, they recognized the need of design guideline for clinical laboratory. As laboratories are prohibited to patients, their environments are becoming more congested and deteriorated as time goes by. So, this study investigates the current status of facility and equipment of laboratory medicine focusing on less than three hundred patient bed hospitals, and searches the improving matters. Methods: Questionnaires to technologist captains and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 18 answers have been analysed statistically by MS Excel program. Results: The result of this study can be summarized into followings. Clinical laboratory functions are all hematology, clinical chemistry, immunology, transfusion and urine microscopy, and except for three including microbiology for infection and bio safety level. Average man power of lab are 12.3 man including lab director and captain. Patient bed number, space area and total specimen numbers are not correlated with each other, but specimen numbers and employee number are correlated with. Work space distances are usually good, but exit distances are not adequate for escape owing to obstacles. Specimen delivery system by courier, test method by automatic analyzer, access floor for exposed plumbing and electricities are more practical. Open lab layed out in the center and lab support layed peripheral in space diagram. Lab space configuration by SD method showed that lab support area and employee support area are dissatisfied. Implications: Specialized hospital and yearly total specimen numbers are related to the space area and organization for laboratory planning and design.

An Experimental Study on the Engineering Properties of Deteriorated Concrete using Recycled Fine Aggregate by Fire Damage (재생잔골재를 활용한 화재피해를 입은 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Kwon, Yung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.190-196
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the Properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, This study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with making variable concrete test specimen, exposing high temperature environment, observing the explosive spalling and examining engineering property.

Experimental study on RC frame structures strengthened by externally-anchored PC wall panels

  • Choi, Seung-Ho;Hwang, Jin-Ha;Lee, Deuck Hang;Kim, Kang Su;Zhang, Dichuan;Kim, Jong Ryeol
    • Computers and Concrete
    • /
    • v.22 no.4
    • /
    • pp.383-393
    • /
    • 2018
  • Infill wall strengthening method has been widely used for seismic strengthening of deteriorated reinforced concrete (RC) frame structures with non-seismic details. Although such infill wall method can ensure sufficient lateral strengths of RC frame structures deteriorated in seismic performances with a low constructional cost, it generally requires quite cumbersome construction works due to its complex connection details between an infill wall and existing RC frame. In this study, an advanced seismic strengthening method using externally-anchored precast wall panels (EPCW) was developed to overcome the disadvantage inherent in the existing infill wall strengthening method. A total of four RC frame specimens were carefully designed and fabricated. Cyclic loading tests were then conducted to examine seismic performances of RC frame specimens strengthened using the EPCW method. Two specimens were fully strengthened using stocky precast wall panels with different connection details while one specimen was strengthened only in column perimeter with slender precast wall panels. Test results showed that the strength, stiffness, and energy dissipation capacity of RC frame specimens strengthened by EPCWs were improved compared to control frame specimens without strengthening.