• Title/Summary/Keyword: Detector sensitivity

Search Result 427, Processing Time 0.024 seconds

Performance Evaluation of Breast Specific Gamma Imaging (Breast Specific Gamma Imaging 장비의 성능평가)

  • Cha, Eun-Sun;Kwak, In-Suk;Noh, Ik-Sang;Yeon, Joon-Ho;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.24-27
    • /
    • 2010
  • Purpose: Early diagnosis of breast is of the utmost importance to improve prognosis. We have a limitation for mammography and sonography detecting small cancer. Clinical importance of Breast Specific Gamma Imaging (BSGI) has improved for that reason. So We studied performance evaluation test of count rate and resolution with high sensitivity to the low dose of BSGI. Materials and Methods: BSGI of Dilon 6800, point source of $^{99m}Tc$ from 1.85~148 MBq (0.05~4 mCi) at the intervals of 1.85~37 MBq (0.05~1 mCi) was used for the test. Performance evaluation method was performed for measuring deadtime for choosing at the 5 different point in the useful field of view (UFOV), acquired image for 60 seconds. Compared with reference of clinical uptake distribution of breast, activity increased according to the distance change 10, 20, 30, 40, 50 mm in the useful field of view. Results: Counting curve increased according to the activity from 1.85 MBq (0.05 mCi) to the 74 MBq (2 mCi), and it change flat shape over 74 MBq (2 mCi). The variation of the full width of half maximum (FWHM) to the distance is 4.05, 4.73, 5.77, 6.90, 8.00, 9.32 mm in 1.85 MBq (0.05 mCi), 4.30, 4.80, 5.90, 7.00, 8.10, 9.07 mm in 3.7 MBq (0.1 mCi), 4.90, 5.60, 6.20, 7.20, 8.20, 9.10 mm in 5.55 MBq (0.15 mCi), 5.30, 6.10, 6.60, 7.00, 7.90, 8.70 mm in 7.40 MBq (0.2 mCi). Conclusion: Distortions of image would be acquired because of the deadtime in BSGI. We found out the fact that specification of $^{99m}Tc$ reaction under 74 MBq (2 mCi) for BSGI. Second, FWHM distribution change from varied distance from the detector, clearly distinguished the location of the lesion.

  • PDF

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening (암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰)

  • Kim, Hyun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.214-227
    • /
    • 2013
  • Computed tomographic scan as a screening procedures in asymptomatic individuals has seen a steady increase with the introduction of multiple-raw detector CT scanners. This report provides a brief review of the current controversy surrounding CT cancer screening, with a focus on the radiation induced cancer risks and clinical efficacy. 1. A large study of patients at high risk of lung cancer(the National Lung Screening Trial[NLST]) showed that CT screening reduced cancer deaths by 20%(1.33% in those screened compared with 1.67% in those not screened). The rate of positive screening tests was 24.2% and 96.4% of the positive screening results in the low-dose CT group were false-positive. Radiation induced lung cancer risk was estimated the most important in screening population because ERR of radiation induced lung cancer does not show the decrease with increasing age and synergistic connection between smoking and radiation risk. Therefore, the radiation risk may be on the same order of magnitude as the benefit observed in the NLST. Optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation. 2. Computed tomographic colonography is as good as colonoscopy for detecting colon cancer and is almost as good as colonoscopy for detecting advanced adenomas, but significantly less sensitive and specific for smaller lesions and disadvantageous for subsequent therapeutic optical colonoscopy if polyps are detected. The average effective dose from CT colonography was estimated 8-10 $mS{\nu}$, which could be a significant dose if administered routinely within the population over many years. CT colonography should a) achieve at least 90% sensitivity and specificity in the size category from 6 and 10 mm, b) offer non-cathartic bowl preparation and c) be optimized and standardized CT parameters if it is to be used for mass screening. 3. There is little evidence that demonstrates, for whole-body scanning, the benefit outweighs the detriment. This test found large portion of patient(86~90.8%) had at least one abnormal finding, whereas only 2% were estimated to have clinically significant disease. Annual scans from ages 45 to 75 years would accrue an estimated lifetime cancer mortality risk of 1.9%. There is no group within the medical community that recommends whole-body CT. No good studies indicate the accuracy of screening CT, at this time. The benefit/risk balance for any of the commonly suggested CT screening techniques has yet to be established. These areas need further research. Therefore wild screening should be avoided.

Establishment of Analytical Method for Dichlorprop Residues, a Plant Growth Regulator in Agricultural Commodities Using GC/ECD (GC/ECD를 이용한 농산물 중 생장조정제 dichlorprop 잔류 분석법 확립)

  • Lee, Sang-Mok;Kim, Jae-Young;Kim, Tae-Hoon;Lee, Han-Jin;Chang, Moon-Ik;Kim, Hee-Jeong;Cho, Yoon-Jae;Choi, Si-Won;Kim, Myung-Ae;Kim, MeeKyung;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2013
  • BACKGROUND: This study focused on the development of an analytical method about dichlorprop (DCPP; 2-(2,4-dichlorophenoxy)propionic acid) which is a plant growth regulator, a synthetic auxin for agricultural commodities. DCPP prevents falling of fruits during their growth periods. However, the overdose of DCPP caused the unwanted maturing time and reduce the safe storage period. If we take fruits with exceeding maximum residue limits, it could be harmful. Therefore, this study presented the analytical method of DCPP in agricultural commodities for the nation-wide pesticide residues monitoring program of the Ministry of Food and Drug Safety. METHODS AND RESULTS: We adopted the analytical method for DCPP in agricultural commodities by gas chromatograph in cooperated with Electron Capture Detector(ECD). Sample extraction and purification by ion-associated partition method were applied, then quantitation was done by GC/ECD with DB-17, a moderate polarity column under the temperature-rising condition with nitrogen as a carrier gas and split-less mode. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.9998, analysed from 0.1 to 2.0 mg/L concentration. Limit of quantitation in agricultural commodities represents 0.05 mg/kg, and average recoveries ranged from 78.8 to 102.2%. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 9.5% in 0.05, 0.10, and 0.50 mg/kg. CONCLUSION(S): Our newly improved analytical method for DCPP residues in agricultural commodities was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.