• Title/Summary/Keyword: Detector Type

Search Result 591, Processing Time 0.031 seconds

tans-Resveratrol Content of Varieties and Growth Period in Peanut (땅콩 품종 및 생육기별 trans-Resveratrol 함량)

  • Lee, Mi-Ja;Cheong, Young-Keun;Kim, Hyung-Soon;Park, Ki-Hun;Doo, Hong-Soo;Suh, Duck-Yong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.6
    • /
    • pp.429-433
    • /
    • 2003
  • trans-Resveratrol(3,5,4'-trihydroxystilbene) is phenolic compound present in grapes, wines, and peanuts, has been reported to have health benefits including anticarcinogenic effects, protection against cardiovascular diseases and reduced cancer risk. A simple method for the quantitative extraction of trans-resveratrol from peanut has been developed. Optimal conditions for extraction were investigated. Type of solvent, time, and temperature assayed influenced trans-resveratrol yield. Adequate extraction condition was decided to ethanol/water (80:20v/v) maintained at $25^{\circ}C$ for 45 min. After extraction, the protocol consists of sample preparation using a $\textrm{C}_{18}$ solid-phase extraction (SPE) cartridge after concentrate with rotary evaporator and quantified by reversed phase HPLC using a $\textrm{C}_{18}$ column at 308 nm. Analytical methods for measuring trans-resveratrol in peanut were adapted to isolate, identify, and quantify trans-resveratrol in 11 peanut varieties by HPLC (high-performance liquid chromatography) with UV detector, The 11 peanut varieties content ranged from 0.018 to 1.125 $\mu\textrm{g}/\textrm{g}$ with an average of 0.289 $\mu\textrm{g}/\textrm{g}$. The contents were higher in the seeds with than without testa, regardless of varieties. The trans-resveratrol content was Higher in 110, 130 days after sowing than that of other period.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Optimization of HPLC Method and Clean-up Process for Simultaneous and Systematic Analysis of Synthetic Color Additives in Foods (식품 중 타르색소의 동시분석 및 계통분석을 위한 HPLC 분석조건 및 정제과정 확립)

  • Park, Sung-Kwan;Hong, Yeun;Jung, Yong-Hyun;Lee, Chang-Hee;Yoon, Hae-Jung;Kim, So-Hee;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.33-39
    • /
    • 2001
  • To develop a method for separation process using Sep-pak $C_18$, simultaneous and systematic analysis of 8 permitted and 11 non-permitted synthetic food colors in Korea, optimization of analysis conditions for reverse phase ion-pair high performance liquid chromatography was carried out. For the best result of Sep-pak $C_18$ separation the pH of color standard mixture solution was $5{\sim}6$ and 0.1% HCl-methanol solution were set as eluent. The colors eluated from Sep-pak $C_18$ cartridge were determined and confirmed by high performance liquid chromatography with a photodiode array detector at 420 nm for yellow colors type, at 520 nm for red colors type, at 600 nm for blue and green colors type and at 254 nm for mixed colors. Conditions for HPLC analysis were as follows: column, Symmetry $C_18$ (5 m, 3.9 mm $i.d.{\times}150\;mm$); mobile phase, 0.025 M ammonium acetate (containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (65 : 25 : 10) and 0.025 M ammonium acetate(containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (40 : 50 : 10); flow rate, 1 mL/min. It takes 35 minutes for simultaneaus analysis and 18 minutes for systematic analysis. The detection limits range of each colors were $0.01{\sim}0.05\;{\mu}g/g$.

  • PDF

Development of a MTF Measurement System for an Infrared Optical System (적외선 광학계용 MTF 측정장치 개발)

  • Son, Byoung-Ho;Lee, Hoi-Yoon;Song, Jae-Bong;Yang, Ho-Soon;Lee, Yun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • In this paper, we developed a MTF (Modulation Transfer Function) measurement system using a knife-edge scanning method for infrared optics. It consists of an objective part to generate the target image, a collimator to make the beam parallel, and a detector to analyze the image. We used a tungsten filament as the light source and MCT (Mercury Cadmium Telluride) to detect the mid-infrared(wavelength $3-5{\mu}m$) image. We measured the MTF of a standard lens (f=5, material ZnSe) to test this instrument and compared the result to the theoretical value calculated using the ZEMAX commercial software. It was found that the difference was within ${\pm}0.035$ at the cut-off frequency (50 1/mm). Also, we calculated the A-type measurement uncertainty to check the reliability of the measurement. The result showed only 0.002 at 20 1/mm in spatial frequency, which means very little variation in the MTF measurement under the same conditions.

An Experimental Study on the Detection of Loosened Areas in a Ground cavity Using a Micro Penetration Test (초소형 관입시험기를 이용한 지반공동 주변지반의 이완영역탐지를 위한 실험적 연구)

  • Kim, Ho-Youn;Kim, Young-Ho;Park, Yoon-Suk;You, Seung-Kyong;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.299-306
    • /
    • 2019
  • In this study, a model experiment that simulates the behaviour of the ground composed of several compacted layer was intended to measure the loosened area in the event of a ground cavity through a LAD (Loosened area detector). It was confirmed that the size of the cone diameter was affected by the ground composed of fine grain + granulated soil layered through the model soil. In order to select the appropriate cone type, a scale effect experiment was conducted. From the test results, a micro-cone was chosen for the most suitable indoor model experiment. In the case of applying LAD in this study, the loosening condition of the ground was determined by the rapid change in penetration resistance caused by the difference in the boundary surface and relative density due to the compaction of the ground for indoor model testing. The range of loosened area occurring in the cavity was estimated through the penetration resistance characteristics on the ground, and the failure area was identified through the reduction rate of penetration resistance in the loosening area.

Bioequivalence of L-Cartin Tablet to Nicetile Tablet (Acetyl-L-Carnitine 500 mg) (니세털 정(아세틸-엘-카르니틴 500 mg)에 대한 엘카틴 정의 생물학적 동등성)

  • Cho, Hea-Young;Yun, Ji-Hun;Oh, Injoon;Moon, Jai-Dong;Lee, Yong-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.11 no.2
    • /
    • pp.49-56
    • /
    • 2001
  • Acetyl-L-carnitine (ALC), an endogenous component of the L-carnitine family, is a naturally existing molecule synthesized from L-carnitine (LC) by carnitine acetyl transferase. ALC has been shown to improve the cognitive performance of patients suffering from dementia of the Alzheimer's type and proposed for treating Alzheimer's disease in pharmacological doses. The purpose of the present study was to evaluate the bioefuivalence of two ALC tablets, $Nicetile^{TM} (Dong-A Pharmaceutical Co.) and $L-Cartin^{TM}$ (Kuhn Il Pharmaceutical Co.), according to the guidelines of Korea Food and Drug Administration (KFDA). The ALC release from the two ALC tablets in vitro was tested using KP VII Apparatus II method in various dissolution media (pH 1.2, 6.0 and 6.8). Twenty six normal male volunteers, $24.46\pm3.67$ years in age and $64.45\pm5.54$ kg in body weight, were divided into two groups and a randomized $2\times2$cross-over study was employed. After one tablet containing 500 mg of ALC was orally administered, blood was taken at predetermined time intervals and the concentrations of ALC in serum were determined using HPLC with fluorescence detector. Because of the presence of endogenous ALC, the calibration was performed using dialyzed serum. The dissolution profiles of the two ALC tablets were similar in all the dissolution media. The pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA was utilized for the statistical analysis of the parameters. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between two tablets were $0.35\%,\;0.93\%\;and\;2.34\%$ respectively, when calculated against the $Nicetile^{TM} tablet. The powers $(1-\beta)\;for\;AUC_t$ , and Cmax were $98.72\%\;and\;85.48\%$, respectively. Minimum detectable differences $(\Delta)\;at\;\alpha=0.05\;and\;1-\beta=0.8$ were less than $20\%,\;(e.g.,\;13.21\%\;and\;18.42\%\;for\;AUC_t,\;and\;C_{max}$ respectively). The $90\%$ confidence intervals were within $\pm20\%\;(e.g.,\;-7.38\sim8.09\;and\;-9.86\sim11.72\;for\;AUC_t,\;and\;C_{max}$, respectively). These two parameters met the criteria of KFDA for bioequivalence, indicating that $L-Cartin^{TM}$ tablet is bioequivalent to $Nicetile^{TM} tablet.

  • PDF

An Analysis of Near-infrared Light Curves of δ Scuti Variable BO Lyn (δ Scuti형 변광성 BO Lyn의 근적외선 광도곡선 분석)

  • Lim, Ji-Hye;Sohn, Jungjoo
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.389-397
    • /
    • 2016
  • In order to investigate the light curve difference in visual and infrared wavelength of ${\delta}$ Scuti variable Bo Lyn, observations were performed using BOAO 1.8m reflecting telescope and an infrared detector, KASINICS, with J, H, and Ks filters. Infrared light curves of total 7 nights were obtained between March and April in 2011, and those were compared to the V-filter light curve to examine the differences in period, time of maximum light, amplitude, and shape. From the periodic analysis of infrared light curve, a single frequency of $f_1=10.712cycle/day$, $P=0.09335{\pm}0.00002days$ was obtained, and there was no difference in the period along different wavelengths. In the infrared light curve, a frequency of $2f_1$ was detected. This frequency well explains the asymmetric shape of light curve, one of the characteristics of high-amplitude ${\delta}$ Scuti variables. We compared the locations of the measured infrared maxima and the predicted maxima of V-filter, finding that the times of maxima were delayed about 0.3 phase at infrared wavelengths. Amplitude ratios were adopted to be ${\Delta}J/{\Delta}V=0.328$, ${\Delta}H/{\Delta}V=0.216$, and ${\Delta}Ks/{\Delta}V=0.211$, with the range of variation being smaller at longer wavelengths. It seems that the differences in the times of maxima and amplitude occurred because the changes in brightness of a pulsating variable star are mainly caused by the change in temperature.

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

Compressed-sensing (CS)-based Image Deblurring Scheme with a Total Variation Regularization Penalty for Improving Image Characteristics in Digital Tomosynthesis (DTS) (디지털 단층합성 X-선 영상의 화질개선을 위한 TV-압축센싱 기반 영상복원기법 연구)

  • Je, Uikyu;Kim, Kyuseok;Cho, Hyosung;Kim, Guna;Park, Soyoung;Lim, Hyunwoo;Park, Chulkyu;Park, Yeonok
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In this work, we considered a compressed-sensing (CS)-based image deblurring scheme with a total-variation (TV) regularization penalty for improving image characteristics in digital tomosynthesis (DTS). We implemented the proposed image deblurring algorithm and performed a systematic simulation to demonstrate its viability. We also performed an experiment by using a table-top setup which consists of an x-ray tube operated at $90kV_p$, 6 mAs and a CMOS-type flat-panel detector having a $198-{\mu}m$ pixel resolution. In the both simulation and experiment, 51 projection images were taken with a tomographic angle range of ${\theta}=60^{\circ}$ and an angle step of ${\Delta}{\theta}=1.2^{\circ}$ and then deblurred by using the proposed deblurring algorithm before performing the common filtered-backprojection (FBP)-based DTS reconstruction. According to our results, the image sharpness of the recovered x-ray images and the reconstructed DTS images were significantly improved and the cross-plane spatial resolution in DTS was also improved by a factor of about 1.4. Thus the proposed deblurring scheme appears to be effective for the blurring problems in both conventional radiography and DTS and is applicable to improve the present image characteristics.