• Title/Summary/Keyword: Detector

Search Result 6,141, Processing Time 0.031 seconds

A simple computational algorithm of ML optimum multiuser detector for synchronous code division multiple access channels (동기화된 부호 분할 다원 접속 채널을 위한 ML 최적 다중 사용자 검출기의 간단한 계산 알고리즘)

  • 권형욱;최태영;오성근
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.5
    • /
    • pp.1-9
    • /
    • 1996
  • In this paper, we propose an efficient computational algorithm that can reduce significantly the computational complexity of the ML optimum multiuser detector known as the most excellent detector in synchronous code division multiple access channels. The proposed detector uses the sequential detection algorithm based on the alternating maximization appraoch to obtain the ML estimates. As initial estimates for this sequential algorithm, we can use the estimated values obtained by the conventional single-user detector, the linear decorrelating multiuser detector, or the decorrelating decision-feedback muliuser detector, the linear decorrelating multiuser detector, or the decorrelating decision-feedback multiuser detector. We have performed computer simulations in order to see the convergence behaviors and the detection performance of the propsoed algorithm in terms of initial algorithms and the number of users, and then to compare the computational complexity with that of the ML optimum multiuser detector. From the results, we have seen that the proposed alternating maximization detector has nearly equal detction performance with that of the ML optimum multiuser detctor in only a few iteration.

  • PDF

Design of Robust Detector with Noise Variance Estimation Censoring Input Signals over AWGN

  • Lee, Hyeon-Cheol;Halverson, Don R.
    • ETRI Journal
    • /
    • v.29 no.1
    • /
    • pp.110-112
    • /
    • 2007
  • As an alternative to the classic linear detector which only assumes noise variance, a new robust detector with noise variance estimation censoring input signals over AWGN is proposed. The results demonstrate that analytic detection probability matches the simulation results for the linear detector and that the new robust detector shows better performance than the linear detector when the number of samples increases.

  • PDF

Design and Implementation of L/Ku-band Broadband Power Detector using Schottky Diode (Schottky 다이오드를 이용한 Six-port용 L/Ku-band 광대역 Power detector 설계 제작)

  • Kim Young-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.615-618
    • /
    • 2006
  • The broadband power detector for direct- onversion Six-port output circuit was designed and implementaed in this paper. The power detector should linearly operated to produce the linear amplitude and phase signal fer input RF signal in required broadband. So, the power detector should be designed under conditions of matching circuit with low VSWR. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with matching circuit and isolator, respectively, were evaluated in the performances.

  • PDF

A New Type of MR Sensor-Based Vehicle Detector with High Performance and Reliability

  • Kang, Moon-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1689-1693
    • /
    • 2004
  • This paper proposes a vehicle detector with a magnetoresistive (MR) sensor. The detector consists of a MR sensor and mechanical and electronic apparatuses. Composed of six magnetically variable resistors, the MR sensor senses disturbance of the earth's magnetic field caused by a moving vehicle over itself and then produces an output indicative of the moving vehicle. Experiments have been carried out with three stages. At the first stage, the outputs of the sensor have been analyzed to show the validity of the detector's circuit and the detecting method. At the second stage, the detector has been tested on a local highway in Korea. Through the field tests, the outputs of the detector in response to various kinds of moving vehicles have been collected and analyzed. At the final stage, to verify the performance of the detector, traffic volumes on the highway have been measured with the detector and compared with the exact traffic volumes in a highly congested traffic.

  • PDF

Novel Fast Peak Detector for Single- or Three-phase Unsymmetrical Voltage Sags

  • Lee, Sang-Hoey;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.658-665
    • /
    • 2011
  • In the present paper, a novel fast peak detector for single- or three-phase unsymmetrical voltage sags is proposed. The proposed detector is modified from a single-phase digital phase-locked loop based on a d-q transformation using an all-pass filter (APF). APF generates a virtual phase with $90^{\circ}$ phase delay. However, this virtual phase cannot reflect a sudden change of the grid voltage in the moment of voltage sag, which causes a peak value to be significantly distorted and to settle down slowly. Specifically, the settling time of the peak value is too long when voltage sag occurs around a zero crossing, such as phase $0^{\circ}$ and $180^{\circ}$. This paper describes the operating principle of the APF problem and proposes a modified all-pass filter (MAPF) to mitigate the inherent APF problem. In addition, a new fast peak detector using MAPF is proposed. The proposed detector is able to calculate a peak value within 0.5 ms, even when voltage sag occurs around zero crossing. The proposed fast peak detector is compared with the conventional detector using APF. Results show that the proposed detector has faster detection time in the whole phase range. Furthermore, the proposed fast peak detector can be effectively applied to unsymmetrical three-phase voltage sags. Simulation and experimental results verify the advantages of the proposed detector and MAPF.

Analysis of Temperature Rise and Operation Time of Differential Spot Type Detector in Case of Mattress Fire in Multi-family House (다가구 주택의 매트리스 화재 시 차동식 스포트형 감지기의 온도상승 및 동작시간 분석)

  • Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.3
    • /
    • pp.97-102
    • /
    • 2021
  • This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performance-centered design.

A Self-Supervised Detector Scheduler for Efficient Tracking-by-Detection Mechanism

  • Park, Dae-Hyeon;Lee, Seong-Ho;Bae, Seung-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.10
    • /
    • pp.19-28
    • /
    • 2022
  • In this paper, we propose the Detector Scheduler which determines the best tracking-by-detection (TBD) mechanism to perform real-time high-accurate multi-object tracking (MOT). The Detector Scheduler determines whether to run a detector by measuring the dissimilarity of features between different frames. Furthermore, we propose a self-supervision method to learn the Detector Scheduler with tracking results since it is difficult to generate ground truth (GT) for learning the Detector Scheduler. Our proposed self-supervision method generates pseudo labels on whether to run a detector when the dissimilarity of the object cardinality or appearance between frames increases. To this end, we propose the Detector Scheduling Loss to learn the Detector Scheduler. As a result, our proposed method achieves real-time high-accurate multi-object tracking by boosting the overall tracking speed while keeping the tracking accuracy at most.

A Study on the exposure dose for the computed tomography (컴퓨터 단층촬영시 환자피폭선량에 관한 연구)

  • Kim, Moon-Chan;Lim, Jong-Suck;Park, Hyung-Ro;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.21-27
    • /
    • 2004
  • This study was conducted to estimate absorbed radiation doses associated with CT examinations. We compared CT dose index between single detector CT and multi detector CT. To establish radiation dose criteria in CT examination in Korea, we measured radiation dose for CT examinations in Seoul and kyungki-do. The results obtained were as follows ; 1. Averaged CTDIW value per 100 mAs was $13.5{\pm}3.2\;mGy$, and ranged from 8.1 mGy to 19.1 mGy in head phantom, was $7.1{\pm}2.0\;mGy$, and ranged from 3.7 mGy to 10.9 mGy in body phantom. 2. CTDIW was 3.2 mGy(1.26 times) larger in multi detector CT than single detector CT in head phantom, and 2.1 mGy(1.34 times) larger in body phantom. 3. The dose was the highest in 4 channel multi detector CT, and followed 8 channel multi detector CT, 16 channel multi detector CT and single detector CT in head phantom. And the dose was the highest in 4 channel and 8 channel multi detector CT, and followed 16 channel multi detector CT and single detector CT in body phantom.

  • PDF

Positional correction of a 3D position-sensitive virtual Frisch-grid CZT detector for gamma spectroscopy and imaging based on a theoretical assumption

  • Younghak Kim ;Kichang Shin ;Aleksey Bolotnikov;Wonho Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1718-1733
    • /
    • 2023
  • The virtual Frisch-grid method for room-temperature radiation detectors has been widely used because of its simplicity and high performance. Recently, side electrodes were separately attached to each surface of the detectors instead of covering the entire detector surface with a single electrode. The side-electrode structure enables the measurement of the three-dimensional (3D) gamma-ray interaction in the detector. The positional information of the interaction can then be utilized to precisely calibrate the response of the detector for gamma-ray spectroscopy and imaging. In this study, we developed a 3D position-sensitive 5 × 5 × 12 mm3 cadmium-zinc-telluride (CZT) detector and applied a flattening method to correct detector responses. Collimated gamma-rays incident on the surface of the detector were scanned to evaluate the positional accuracy of the detection system. Positional distributions of the radiation interactions with the detector were imaged for quantitative and qualitative evaluation. The energy spectra of various radioisotopes were measured and improved by the detector response calibration according to the calculated positional information. The energy spectra ranged from 59.5 keV (emitted by 241Am) to 1332 keV (emitted by 60Co). The best energy resolution was 1.06% at 662 keV when the CZT detector was voxelized to 20 × 20 × 10.

The Optimum Noncoherent Detector for M-ray Nonorthogonal Signals (M진 비직교 신호를 위한 최적의 위상비동기 검출기)

  • Jin, Guang-Yun;Kwak, Kyung-Sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.4C
    • /
    • pp.392-396
    • /
    • 2003
  • This paper proposes an optimum noncoherent detector for M-ary nonorthogonal, unequal energies, unequal priori probabilities nonlinear modulation signals. Theretical derivations are given in detail. Under above conditions, there is not any previous papers to explore the corresponding optimum noncoherent detector. The detector proposed in this paper can be regarded as a generic optimum detector which can be applied to nonorthogonal nonlinear M-ary communication systems.