• 제목/요약/키워드: Detection Pressure

Search Result 658, Processing Time 0.025 seconds

Characterization to flammable gas $\alpha$-$Fa_{2}O_{3}/SnO_{2}$ system thin film fabricated by APCVD (APCVD법에 위해 제조된 $\alpha$-$Fa_{2}O_{3}/SnO_{2}$계 박막의 가연성 가스 감지 특성 평가)

  • 심성은;이세훈;최성철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.2
    • /
    • pp.105-110
    • /
    • 2000
  • The $\alpha$-$Fa_{2}O_{3}/SnO_{2}$ thin film gas sensor was fabricated by APCVD and heat treated. The gas sensitivity to flammable gases ($CH_4$, $H_2$, LPG) was measured. This device was to heat treatment at $400^{\circ}C$, $450^{\circ}C$, $500^{\circ}C$, $550^{\circ}C$, $600^{\circ}C$ for 2 h to enhance the gas sensitivity. The heat treated device at $500^{\circ}C$ for 2 h had the best properties and especially it shows high sensitivity to H2 gas. The sensitivity to gases was studied in the temperature range from lOoC to $300^{\circ}C$ in order to find the optimum detection temperature. In the range of detection from 500 ppm to 10,000 ppm at $175^{\circ}C$ the fabricated device showed that the gas sensitivity to $H_2$ was from 62%~76% and to $CH_4$ was from 16 %~58% and to LPG was from 8%~37 %. The sensitivity difference between heat treated device and as fabricated one was about 10 8 The long-term stability to LPG at 1,000 ppm was converged to sensitivity of 30 %.

  • PDF

Walking Intention Detection using Fusion of FSR and Tilt Sensor Signals (저항 센서와 기울기 센서의 융합에 의한 보행 의도 감지)

  • Jang, Eun-Hye;Chun, Byung-Tae;Lee, Jae-Yeon;Chi, Su-Young;Kang, Sang-Seung;Cho, Young-Jo
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.441-448
    • /
    • 2010
  • In the aging society, the walking assist robot is a necessary device for being able to help the older and the lower limb disabled people to walk. In order to produce a convenient robot for the older and the lower limb disabled, it is needed for the research to detect the implicit walking intention and to control robot by a user's intention. This study is a previous study to develop the detection model of the walking intention and analyze the user's walking intention while a person is walking with Lofstrand crutches, by the combination of FSR and tilt signals. The FSR sensors attached user's the palm and the soles of foot are sensing force/pressure signals from these areas and are used for detecting the walking intention and states. The tilt sensor acquires roll and pitch signal from area of vertebrae lumbales and reflects the pose of the upper limb. We can recognize the user's walking intention such as 'start walking', 'start of right or left foot forward', and 'stop walking' by the combination of FSR and tilt signals can recognize.

  • PDF

Investigation of Sound Pressure Detection of Fiber Optic Sensor in Transformer Oil According to TLS and CW Laser Source (TLS와 CW 광원에 따른 트랜스포머 오일 내에서 광섬유 센서의 음압 감지 특성 연구)

  • Lee, Jong-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • To substitute TLS in the hybrid system which is combined with Sagnac interferometer and fiber bragg grating (FBG) it is necessary to investigate how the laser source (TLS and CW) and sensor material variate the response of fiber optic sensor. Two different hollow cylinder type mandrel materials are proposed which are PTFE and PTFE+carbon and 18 m optical fiber is wounded at the mandrel surface. CW laser source experiments had been done in the oil tank which is filled with transformer oil in the 1 kHz~20 kHz frequency range. Also Sagnac interferometer fiber optic sensor is combined with FBG called hybrid system and TLS used as a light source. Based on the experimental results PTFE sensor showed more higher magnitude of detection signal rather than carbon sensor and this result is agreement with the McMahon's theoretical results. Phase variation is inversely proportional to the elastic modulus of the mandrel material. In PTFE fiber sensor, tunable laser source showed more higher performance rather than CW case. Therefore, TLS fiber optic sensor can be applied to the hybrid system which is combined with Sagnac and FBG.

A Study on Fault Detection Monitoring and Diagnosis System of CNG Stations based on Principal Component Analysis(PCA) (주성분분석(PCA) 기법에 기반한 CNG 충전소의 이상감지 모니터링 및 진단 시스템 연구)

  • Lee, Kijun;Lee, Bong Woo;Choi, Dong-Hwang;Kim, Tae-Ok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.53-59
    • /
    • 2014
  • In this study, we suggest a system to build the monitoring model for compressed natural gas (CNG) stations, operated in only non-stationary modes, and perform the real-time monitoring and the abnormality diagnosis using principal component analysis (PCA) that is suitable for processing large amounts of multi-dimensional data among multivariate statistical analysis methods. We build the model by the calculation of the new characteristic variables, called as the major components, finding the factors representing the trend of process operation, or a combination of variables among 7 pressure sensor data and 5 temperature sensor data collected from a CNG station at every second. The real-time monitoring is performed reflecting the data of process operation measured in real-time against the built model. As a result of conducting the test of monitoring in order to improve the accuracy of the system and verification, all data in the normal operation were distinguished as normal. The cause of abnormality could be refined, when abnormality was detected successfully, by tracking the variables out of the score plot.

Comparative Study of DNA Fragment According to Steps of Genetically Modified Soybean Processed Food (대두 가공식품의 공정단계별 유전자재조합체(GMO) 단편의 검출확인 및 비교 연구)

  • Hwang, Sun-Wook;Lee, Cheol-Su;Nam, Young-Suk;Kim, Su-Bok;Oh, Duk-Hwan;Kim, Young-Chan
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.4
    • /
    • pp.211-217
    • /
    • 2003
  • To discriminate between the genetically modified soybean processed foods which were Korean traditional foods as Beansprout, doenjang, Beancurd (Tofu) and the unmodified one. we had analyzed comparatively that the loss degree of inner DNA about denaturalization factors in process step as heat or pressure and decision of suitable PCR primer by size. As a result of having compared about ${\beta}$-actin was 160bp, 335 promotor was 130 bp and NOS terminator was 132 bp effective. As a result of having checked a loss degree of a gene, as for the bean curd, DNA was mostly preserved well, and the loss of DNA along the processing process was hardly observed by a processing process. Most DNA of beansprout have moved to trunk after germination stage, and the appropriate analysis part was judged as the trunk. And the doenjang showed a detection difference of DNA by an operation of an enzye among self-life periods. Besides, after 50days, insertion gene was destoryed entrely so that detection was not possible.

Dynamic Electromyography Analysis of Shoulder Muscles for One-handed Manual Material Handling

  • Mo, Seung-Min;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.313-326
    • /
    • 2015
  • Objective: The objective of this research is to quantitatively analyze muscle activities of arm and shoulder, according to direction in various types of one-handed manual material handling, based on surface electromyography. Background: Workers in industrial sites frequently carry out one-handed manual material handling using arm and shoulder muscles. Therefore, chronic load and accumulated fatigue occur to arm and shoulder muscles, which becomes a main cause of upper arm and shoulder musculoskeletal disorders. The shoulder muscles have widely range of motion, and complex interactions take place among various muscles including rotator cuff muscles. In this regard, research on interactions among should muscles, according to such various dynamic motions, is required. Method: Ten male subjects in their 20s participated in this research. This research considered upward, downward, leftward, rightward, forward and backward directions and fourteen muscles around arm and shoulder (biceps brachii and trapezius, etc.) as independent variables. The mean muscle activity was set as the dependent variable. This research extracted $4^{th}{\sim}7^{th}$ repetition signals according to ten times of repetitive muscle contraction, and analyzed the muscle activity concerned using the envelope detection technique. Results: The mean muscle activity of upward direction was analyzed highly statistically significant. The reason is that the effect of gravity works to arm and shoulder muscles. Also, it is conjectured that deformation of coracoacromial ligament was caused, and its contact pressure increased, due mainly to the shoulder flexion, and therefore load was analyzed high. Muscle activity was analyzed significantly low, according to concentric ballistic motion used in the concentric contraction phase by storing elastic energy in the eccentric contraction phase with a motion to bring the weight to the front of subject's body as to downward, leftward and backward directions. Because, elbow joint's flexion-extension motions mainly occurred, biceps brachii was analyzed high muscle activity as the prime mover. Conclusion: The information on the quantitative load of muscles can be applied to ergonomic work design for one-handed manual material handling to minimize muscle load. Application: This research has effectively identified muscle activity according to dynamic contraction by applying an envelope detection technique. The results can be used for ergonomic work design to minimize muscle load during the one-handed manual material handling, according to each direction. The research results are expected to be used for musculoskeletal disorder prevention and physiotherapy in the rehabilitation medical field, based on the muscle load of arm and shoulder in various directions.

Recurrent Neural Network Modeling of Etch Tool Data: a Preliminary for Fault Inference via Bayesian Networks

  • Nawaz, Javeria;Arshad, Muhammad Zeeshan;Park, Jin-Su;Shin, Sung-Won;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.239-240
    • /
    • 2012
  • With advancements in semiconductor device technologies, manufacturing processes are getting more complex and it became more difficult to maintain tighter process control. As the number of processing step increased for fabricating complex chip structure, potential fault inducing factors are prevail and their allowable margins are continuously reduced. Therefore, one of the key to success in semiconductor manufacturing is highly accurate and fast fault detection and classification at each stage to reduce any undesired variation and identify the cause of the fault. Sensors in the equipment are used to monitor the state of the process. The idea is that whenever there is a fault in the process, it appears as some variation in the output from any of the sensors monitoring the process. These sensors may refer to information about pressure, RF power or gas flow and etc. in the equipment. By relating the data from these sensors to the process condition, any abnormality in the process can be identified, but it still holds some degree of certainty. Our hypothesis in this research is to capture the features of equipment condition data from healthy process library. We can use the health data as a reference for upcoming processes and this is made possible by mathematically modeling of the acquired data. In this work we demonstrate the use of recurrent neural network (RNN) has been used. RNN is a dynamic neural network that makes the output as a function of previous inputs. In our case we have etch equipment tool set data, consisting of 22 parameters and 9 runs. This data was first synchronized using the Dynamic Time Warping (DTW) algorithm. The synchronized data from the sensors in the form of time series is then provided to RNN which trains and restructures itself according to the input and then predicts a value, one step ahead in time, which depends on the past values of data. Eight runs of process data were used to train the network, while in order to check the performance of the network, one run was used as a test input. Next, a mean squared error based probability generating function was used to assign probability of fault in each parameter by comparing the predicted and actual values of the data. In the future we will make use of the Bayesian Networks to classify the detected faults. Bayesian Networks use directed acyclic graphs that relate different parameters through their conditional dependencies in order to find inference among them. The relationships between parameters from the data will be used to generate the structure of Bayesian Network and then posterior probability of different faults will be calculated using inference algorithms.

  • PDF

Anaylsis of ${\gamma}$-aminobutyric Acid (GABA) Content in Germinated Pigmented Rice (발아 유색미의 GABA(${\gamma}$-aminobutyric acid) 함량 분석)

  • An, Mi-Kyoung;Ahn, Jun-Bae;Lee, Sang-Hwa;Lee, Kwang-Geun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.632-636
    • /
    • 2010
  • The level of ${\gamma}$-aminobutyric acid (GABA) in pigmented rice was quantitatively and qualitatively determined by high pressure liquid chromatography/fluorescence detection (HPLC/FLD). In this study, the recovery rate and limit of detection (LOD) of GABA were 122.4${\pm}$2.4% and 0.23 ${\mu}g/g$, respectively. The geminating pigmented rice samples, which were harvested in Paju, Korea, were soaked in water at $18^{\circ}C$ for 20 hr. After soaking, the samples were germinated at $30^{\circ}C$ for about 24 hr. GABA content was highest (293.0 ${\mu}g/g$) in the germinated red rice. Furthermore, GABA levels in the germinated rice increased significantly by up to 11.1 and 24.7-fold as compared to non-germinated rice and milled rice, respectively. The GABA concentrations of non-germinated rice, with the exception of red rice, were significantly higher than those of milled rice by 7.6-20.6-fold.

Estimation of Mass Size Distribution of Atmospheric Aerosols Using Real-Time Aerosol Measuring Instruments (실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정)

  • Ji, Jun-Ho;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.39-50
    • /
    • 2013
  • Real-time aerosol measuring instruments have been widely used for the measurement of atmospheric aerosol, diesel particulate matter, or material synthesis. A scanning mobility particle sizer (SMPS) measures the number size distribution of particles using electrical mobility detection technique. An aerodynamic particle sizer (APS) is used to determine the number concentration and the mean aerodynamic diameter of test particles. An electrical low-pressure impactor (ELPI) is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. In this study, the performance of these instruments were evaluated to assess their ability to obtain mass concentrations from particle number concentration measurements made as a function of particle size. The effect of determination of particle density on the measurement of mass concentration was investigated for the three instruments.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.