• Title/Summary/Keyword: Detection Pressure

Search Result 658, Processing Time 0.027 seconds

A study of noise source identification on plate excited structure borne sound by acoustic intensity method (음향인텐시티법에 의한 고체진동 가진판의 소음원 검출에 관한 연구)

  • 오재응;김상헌;홍동표;이찬홍
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.43-55
    • /
    • 1986
  • In the studies of noise reduction, it is important to know the generation mechanism of noise in order to identify the noise source. The relation between the structural vibration and the radiated sound is very complex and so this paper deals with a simplified radiation model that was originally developed as a verification tool for the acoustic intensity measurement procedure. As the first step for the identification of the noise source, this study deals with the noise evaluation by measuring sound pressure. On the next step, the acoustic radiational pattern is determined by the acoustic intensity method and this paper established that the acoustic intensity method is effective on the detection of noise. In the study, furthermore, the method could be used to predict the change in the sound radiational characteristics with the attachment of absorber and could be used in determining the attachment position.

  • PDF

Precision exploration of space resources using laser-induced breakdown spectroscopy (레이저 유도 플라즈마 분광분석법을 활용한 정밀 우주 자원 탐사)

  • Choi, Soo-Jin;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.5
    • /
    • pp.451-457
    • /
    • 2011
  • A short laser pulse irradiates a sample to create the highly energetic plasma that emits light of a specific wavelength peak according to the material. By identifying different peaks for the analyzed samples, its chemical composition can be rapidly determined. The LIBS (Laser-Induced Breakdown Spectroscopy) has great advantages as an elemental analyzer on board a space rover, namely real-time rapid analysis and stand-off detection. The LIBS signal intensity is remarkably increased by using double-pulse LIBS system for component analysis of lunar environments where the surrounding pressure is low. Also the angle of target is adjusted for replicating arbitrary shapes of the specimen.

Tocopherol Content and Composition in Peanut

  • Yun, Song-Joong;Park, Myoung-Ryoul;Baek, So-Hyeon;Cheong, Young-Keun;Lee, Myung-Chul;Park, Kyeong-Gu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.4
    • /
    • pp.279-283
    • /
    • 2001
  • The content and composition of tocopherol were analyzed in peanuts produced in Korea. The tocopherol assay was consisted of an extraction with n-hex-ane:isopropanol mixture followed by high pressure liquid chromatography with fluorescence detection. Tocopherol content was higher in leaves and seeds but lower in seed coats and shells. $\alpha$-/${\gamma}$- Tocopherol ratio was as low as 0.53 in seeds and as high as 22.5 in shells. Tocopherol content in seeds of nine varieties ranged from 142 to 220 ng/mg dry weight, and the $\alpha$-/${\gamma}$-tocopherol ratio from 0.40 to 0.75. Tocopherol content decreased by 18% but $\alpha$-/${\gamma}$-tocopherol ratio increased by 44% in roasted seeds. The results indicate that the level of tocopherol in Korean peanut varieties is moderate and the ratio of $\alpha$- to ${\gamma}$-tocopherol is low.

  • PDF

Elemental Analysis of Coal by Inductively Coupled Plasma Mass Spectrometry (誘導結合플라스마 質量分析法에 의한 石炭의 元素 分析)

  • 이용근;고인형;이동수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.155-161
    • /
    • 1992
  • A simple, fast yet sensitive method is described for the determination of fifty elements in coal by inductively coupled plasma mass spectrometry. The method involves complete dissolution of coal with mixed acid $(HNO_3, HF, HClO_4)$ in hish pressure Teflon bomb and subsequent inductively coupled plasma mass spectrometric(ICP-MS) measurement. The accuracy of the method, being evaluated by the analysis of NIST SRMs (1632a, 1632b) is better than 20% RSD for most elements. The limits of detection defined by two times $\sigma$ (standard deviation of operational blank) are in order of sub-ppm to ppm, which are low enough to quantitate most elements. However, the determiantions for few elements such as V, As, Se are severely interfered by molecular ions such that their accurate determiantions are not possible. Analytical results for twentyon coals from eight countries including six ones world major coal producing, Korea, Japan, China, I.C.S., U.S.A., Canada, Australia, and South Africa are presented. While the results for major elements agree well with the existing ones, those for a few trace elements disagree considerably. The existing values are considerably higher. It is not possible to judge which are more accurate. However, the exisisting values are more likely to be errorous inasmuch as they are obtained without using high purity reagents and clean laboratory techniques.

  • PDF

Stiffness Characteristics of Salt Cementation according to Depth (깊이에 따른 소금의 고결화 강성특성)

  • Eom, Yong-Hun;Byun, Yong-Hoon;Truong, Q. Hung;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.472-481
    • /
    • 2009
  • Cementation phenomenon has a huge influence on geotechnical stiffness and strength under low confining pressure. The goal of this study is to evaluate the characteristics of stiffness according to the depth. The piezo disk elements are installed at each layer of the cell for the detection of the compressional waves. The change of compressional wave velocity is classified by three stages. The compressional wave velocities are shown different according to the depth. The compressional wave velocity is especially influenced by cementation, effective stress, and coordinate number. Furthermore, the electrical conductivity and cone tip resistance are measured according to the depth. The electrical conductivity and the cone tip resistance show the similar trend with the compressional wave velocity. This study shows that the cementation by salt is affected by the depth on the granular materials.

  • PDF

Grouting Effects of Microfine Cement in the Rock-based Sites (시멘트계 주입재료의 암반그라우팅 효과)

  • Kong, Jinyoung;Kim, Chanki;Park, Jinhwan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.12
    • /
    • pp.37-45
    • /
    • 2010
  • The particle size of microfine cement(MC) is so small that it can be injected into silt layer. But the more particle size is miniaturized, the more the cohesion increases. This phenomenon results in the decrease of the perviousness of MC. In this study, the grouting effects of microfine cement with superplasticizer to maintain cohesion low and that of normal cement were investigated in rock. To estimate the grouting effects, TCR/RQD test for rock quality, lugeon test, borehole loading test for coefficients of elastic and deformative stress, borehole shear test for shear stress, detection p~q~t(pressure~flow~time) chart tests were carried out. The results using MC show a better permeability, modulus of elasticity, deformation, charge per unit, and recover efficiency of grouting material than those of ordinary portland cement except shear stress.

An Implementation of the embedded hardware system based Ultrasonic Spirometer and Improvement of Its Sensitivity (임베디드 하드웨어 시스템 기반의 초음파 폐활량계 구현 및 감도 향상 연구)

  • Lee, Cheul-Won;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.417-420
    • /
    • 2005
  • The spirometer is a medical device that measures the instantaneous velocity of the respiratory gas flow capacity. It is used for testing the condition of the lung and patient monitoring. It measures the absolute capacity difference that includes the flow capacity signal. In this paper, by using an ultrasound sensor that reduce the error caused by the inertia and pressure it has improved the transmission and receiving signal. This has enabled patients with weal respiratory to use the spirometer. Also, by using the embedded hardware system, a precise and prompt detection system was implemented.

  • PDF

The Electrical and Radiation Detection Properties of $Au/Cd_{1-x}Zn_x/Te(x=20%)/Au$ Structure ($Au/Cd_{1-x}Zn_x/Te(x=20%)/Au$ 구조의 전기적 특성 및 방사선 탐지 특성)

  • 최명진;왕진석
    • Electrical & Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.39-44
    • /
    • 1997
  • Bulk type radiation detector of Au/Cd$_{1-x}$ Zn$_{x}$Te(x=20%)/Au structure using Cd$_{1-x}$ Zn$_{x}$Te(x=20%) wafer(3x4xl mm$^{3}$) grown by high pressure Bridgman method has been developed. We etched wafer surfaces with 2% Br-methanol solution and coated gold thin film on the surfaces by electroless deposition method for 5 min. in 49/o HAuCI$_{3}$ 4H20 solution. Initial etch rates of Cd, Zn and Te were 46%, 12% and 42% respectively. After etched, the surface of wafer was slightly revealed to Te rich condition. The leakage current was increased with etch time, but it didn't exceed 3nA at 50volt. The thickness of Au film was about 100nm by Rutherford Backscattering Spectroscopy(RBS). The resolution were 6.7% for 22.1 keV photon from 109 $^{109}$ Cd and 8.2% for 59.5 keV photon from $^{241}$ Am. The radiation detector such as Au/Cd$_{1-x}$ Zn$_{x}$Te(x=20%)/Au structure was more effective to monitor the low energy gamma radiation.iation.

  • PDF

A Study of The $NO_2$ Gas Detect Properties of Tetra-3-hexadecyl-sulphamoylcopperphthalocyanine(HDSM-CuPc) Langmuir-Blodgett Film. (HDSM-CuPc LB막의 $NO_2$ 가스특성에 관한 연구)

  • Han, Y.J.;Kim, H.S.;Yoo, B.H.;Lee, C.H.;Kim, Y.K.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.237-239
    • /
    • 1994
  • The $NO_2$ gas-detection characteristics were investigated using the functional organic Langmuir-Blodgett(LB) film of Tetra-3-hexadecyl-sulphamoylcopperphthalocyanine(HDSM-CuPc). A surface pressure of 30mN/m was obtained as a proper one for a film deposition. A deposited film status was confirmed by electrical and optical methods such as UV/visible absorption spectra and current-voltage(I-V) characteristics. The $NO_2$ gas response experiments under 200ppm concentration show that there is not increment of electrical conductivity in room temperature and is identified by UV/visible absorption spectra. But There are some increments of electrical conductivity in $160^{\circ}C$.

  • PDF

One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System (휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩)

  • Park, Sin-Wook;Kang, Tae-Ho;Lee, Jun-Hwang;Yoon, Hyun-C.;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.