• 제목/요약/키워드: Detectable range

검색결과 171건 처리시간 0.027초

Portable Infrared Laser Transmitter Based on a Beam Shaper Enabling a Highly Uniform Detectable Beam Width

  • Yue, Wenjing;Kim, Haeng-Jung;Lee, Sang-Shin
    • Journal of the Optical Society of Korea
    • /
    • 제17권6호
    • /
    • pp.486-490
    • /
    • 2013
  • A portable infrared laser transmitter delivering a highly uniform detectable beam was demonstrated. It incorporates a flexible beam shaper, comprising a perforated diffuser sheet in conjunction with a pinhole. The beam shaper plays the prominent role of flexibly tailoring the incoming light via both scattering and diffraction, in order to equalize the effective beam width over a long distance. The intensity profile of a generated beam was practically observed, demonstrating that a substantially uniform beam of 70-cm width was achieved for a given threshold detection level, with an average deviation of 6% over a range of 600 m.

Development of a real-time mobile gamma-ray measurement system for shipboard use

  • Chang-Jong Kim;Mee Jang;Hyuncheol Kim;Jong-Myoung Lim;Wanno Lee;Gyu-Seong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4077-4082
    • /
    • 2023
  • Large areas must be rapidly screened to monitor radiation in marine environments. For this purpose, this study developed a mobile real-time gamma-ray measurement system for shipboard use and evaluated its performance. The system was developed to measure engine or generator cooling water by installing a canister inside the ship. The minimum detectable activity of the system is about 0.8 Bq/L for a 60 s measurement period, and real-time data transmission and remote control are possible. The system was tested in the field and is currently being installed and operated on ships in service. Such a ship-based real-time gamma-radiation measurement system is suitable for a wide range of marine radiation surveillance applications and is expected to be rapidly deployed.

연안목적용 저출력 어군탐지기 음향계의 개발에 관한 연구 (A Study on Development of the Low Electrical Power Echo Sounder System for Coastal Use)

  • 박주삼
    • 해양환경안전학회지
    • /
    • 제15권3호
    • /
    • pp.243-250
    • /
    • 2009
  • 연안에서 목적으로 하는 어업에 적합하도록 소형 어군탐지기를 효율적으로 설계하고 평가할 수 있는 방법에 대해 검토하기 위하여 일반적으로 사용되고 있는 어군탐지기의 특성과 탐지범위 등에 대해 조사하였다. 먼저 일반적인 어군탐지기의 빔폭은 주파수와 송신전력이 상승함에 따라 좁아지고 송수파기의 직경은 송신전력이 증가함에 커지는 경향을 보였다. 이 특성을 이용하여 상업적으로 사용되는 일반적인 어군탐지기의 신호대 잡음비를 유도하였다. 탐지거리와 탐지폭으로 구성되는 탐지범위는 이 신호대 잡음비(SN비)로부터 얻을 수 있다. 탐지거리는 주파수의 증가와 함께 증가하였지만 고주파에서는 흡수계수의 영향으로 원거리 탐지가 어려워진다. 즉 송수파기 직경, 송신전력의 증가에 따른 효과는 저주파에서는 크고, 고주파에서는 적은 경향을 보인다. 탐지범위 등을 종합적으로 응용하여 휴대용 어군탐지기의 설계 범용도를 작성하였다. 범용도에는 SN비를 송수파기의 직경, 빔폭, 탐지거리를 변수로하여 주파수에 대해 표시하였다. 범용도에서 SN비가 높고 실용성이 높은 적절한 설계영역을 표시하였다. 설계영역에서 설계점을 정하면 전체적으로 적절한 설계를 할 수 있다. 설계범용도는 어군탐지기의 성능평가에도 응용할 수 있다.

  • PDF

펄스길이에 따른 이중편파변수의 민감도 분석 (Sensitivity Analysis of Polarimetric Observations by Two Different Pulse Lengths of Dual-Polarization Weather Radar)

  • 이정은;정성화;김종성;장근일
    • 대기
    • /
    • 제29권2호
    • /
    • pp.197-211
    • /
    • 2019
  • The observational sensitivity of dual-polarization weather radar was quantitatively analyzed by using two different pulse widths. For this purpose, test radar scan strategy which consisted of consecutive radar scan using long (LP: $2{\mu}s$) and short (SP: $1{\mu}s$) pulses at the same elevation angle was employed. The test scan strategy was conducted at three operational S-band dual-polarization radars (KSN, JNI, and GSN) of Korea Meteorological Administration (KMA). First, the minimum detectable reflectivity (MDR) was analyzed as a function of range using large data set of reflectivity ($Z_H$) obtained from JNI and GSN radars. The MDR of LP was as much as 7~22 dB smaller than that of SP. The LP could measure $Z_H$ greater than 0 dBZ within the maximum observational range of 240 km. Secondly, polarimetric observations and the spatial extent of radar echo between two pulses were compared. The cross-polar correlation coefficient (${\rho}_{hv}$) from LP was greater than that from SP at weak reflectivity (0~20 dBZ). The ratio of $Z_H$ (> 0 dBZ) and ${\rho}_{hv}$(> 0.95) bin to total bin calculated from LP were greater than those from SP (maximum 7.1% and 13.2%). Thirdly, the frequency of $Z_H$ (FOR) during three precipitation events was analyzed. The FOR of LP was greater than that of SP, and the difference in FOR between them increased with increasing range. We conclude that the use of LP can enhance the sensitivity of polarimetric observations and is more suitable for detecting weak echoes.

A Study on the Enhancement of Detection Performance of Space Situational Awareness Radar System

  • Choi, Eun-Jung;Lee, Jonghyun;Cho, Sungki;Moon, Hyun-Wook;Yum, Jea-Myong;Yu, Jiwoong;Park, Jang-Hyun;Jo, Jung Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권4호
    • /
    • pp.279-286
    • /
    • 2018
  • Radar sensors are used for space situational awareness (SSA) to determine collision risk and detect re-entry of space objects. The capability of SSA radar system includes radar sensitivity such as the detectable radar cross-section as a function of range and tracking capability to indicate tracking time and measurement errors. The time duration of the target staying in a range cell is short; therefore, the signal-to-noise ratio cannot be improved through the pulse integration method used in pulse-Doppler signal processing. In this study, a method of improving the signal-to-noise ratio during range migration is presented. The improved detection performance from signal processing gains realized in this study can be used as a basis for comprehensively designing an SSA radar system.

A Transverse Load Sensor with Reconfigurable Measurement Accuracy Based on a Microwave Photonic Filter

  • Chen, Han;Li, Changqing;Min, Jing
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.519-524
    • /
    • 2018
  • We propose a transverse load sensor with reconfigurable measurement accuracy based on a microwave photonic filter in the $K_u$ band, incorporating a polarization-maintaining fiber Bragg grating. A prototype sensor with a reconfigurable measurement accuracy tuning range from 6.09 to 9.56 GHz/(N/mm), and corresponding minimal detectable load range from 0.0167 to 0.0263 N/mm, is experimentally demonstrated. The results illustrate that up to 40% manufacturing error in the grating length can be dynamically calibrated to the same corresponding measurement accuracy for the proposed transverse load sensor, by controlling the semiconductor optical amplifier's injection current in the range of 154 to 419 mA.

초음파 거리계의 성능 개선에 관한 연구 (A study on performance improvement of ultrasonic ranging system)

  • 박종건;임영철;조경영;박철수;김영민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1209-1213
    • /
    • 1991
  • This paper describes a new method for performance improvement ultrasonic ranging system using V40 controller. Detectable range of ultrasonic ranging system depends on transducer frequency and bandwidth of the receiver, and damping of the transducer, etc. Conventional ranging systems are somewhat inaccurate because they do not have capability of compensating changes in medium condition. The novel ranging system overcomes this disadvantage by placing in the same medium a dummy sensor functioning as a standard calibrating instrument and by providing data processing capability using V40 controller.

  • PDF

광섬유를 이용한 음파탐지기의 제작 (Fiber-Optic Sensor for Acoustic Waves)

  • 유회준;이경목;황준암
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1983년도 추계학술발표회논문집
    • /
    • pp.44-47
    • /
    • 1983
  • Through intensity modulation induced by micro bending of an optical fiber, a sensor detects the pressure and frequency of acoustic wave has been implemented. Axial slots on the cylinder suface with a period of 5.5 mm induce efficient microbending of the fiber, and a rubber sleeve covering the fiber enhances the fiber. Compared with a conventional hydrophone, it has a low minimum detectable pressure and can detect acoustic wave in 100Hz - 2KHz range.

  • PDF

Gas Chromatography법에 의한 Quercetin의 미량분석에 관한 연구 (Microquantitative Analysis of Quercetin by Gas Chromatography)

  • 이숙연;김성경
    • 약학회지
    • /
    • 제26권2호
    • /
    • pp.117-121
    • /
    • 1982
  • This investigation was intended to develope the quantitative gas liquid chromatographic method for quercetin. The method involves derivatization of the sample with trimethylsilylimidazole containing cholesterol as an internal standard and injection into a gas chromatograph with 3% OV-17 column. The calibration curve for the quercetin was linear over a sample in the range of 4-16.mu.g. The minimum detectable amount using FID in $1.6{\times}10^{-10}$ a.f.s. was determined to be $6.64{\times}10^{-10}mol$.

  • PDF

유도초음파를 이용한 장거리 배관 탐상기법 (Long Range Ultrasonic Guided Wave Techniques for Inspection of Pipes)

  • 박익근;김용권;김현묵;송원준;조용상;안연식
    • Journal of Welding and Joining
    • /
    • 제23권5호
    • /
    • pp.43-48
    • /
    • 2005
  • Conventional non-destructive techniques for inspection of the weld in pipelines require significant test time and high cost. Ultrasonic guided waves have been widely studied and successfully applied to various non-destructive tests with advantage of the long-range inspection. In this paper, a study on the application of ultrasonic guided waves to the long-range inspection of the pipeline is presented using a long-range guided wave inspection system, Wavemaker SE16, GUL. The characteristics and setup of the long-range guided wave inspection system and experimental results in pipes of with various diameter are introduced. The experimental results in mock-up pipes with cluster type detects show that the minimum detectable wall thickness reduction with this guided wave system is $2\~3\%$ in the pipe cross section area. And the wall thickness reduction of $5\%$ in cross section area can be detected when actual detection level is used. Therefore, the applicability of the guided wave systeme to long-range inspection of wall thickness reduction in pipes is verified.