• Title/Summary/Keyword: Detectable range

Search Result 172, Processing Time 0.019 seconds

A Study on the Radar Maximum Detectable Range of the Floats of Set-nets and the Floating Corner Reflector (정치망뜸과 부표형 코우너 리프렉터의 레이다 최대심지거이에 대한 연구)

  • 신형일
    • Journal of the Korean Institute of Navigation
    • /
    • v.1 no.1
    • /
    • pp.17-26
    • /
    • 1977
  • A large number of the set-nets are set in Namhaedo coast of Korea. The floats of these set-nets are not only small even in case of large floats but also they scarcely have distinguishable marks such as light buoys or flags, so that they are very hard to be recognized by naked eyes and thus became probable obstacles to navigation for the passing ships and the fishing vessels. In order to research the capability of detecting such nets with Radar, the author investigated a maximum detectable range of the ordinarly large floatsand of a floating corner reflectors of various size and shape by Radar. The results obtained are as follows; 1. A maximum detectable range of large floats at a close range can be calculated by the Radar equation in sufficient accuracy. 2. Large floats of the large set-nets are also detectable by Radar even though it's detectable range boundary was within 0.2-0.65 miles. And the Radar picture of large floats was easier to be found with somewhat higher setting of the gain control on shorter range scale of the 1 mile. 3. Floating corner reflector rather suitable for set-net floats of "S" type reflector proposed in this paper, of which the dimension must be above 17cm in diameter to be detectable by Radar at 2 miles.t 2 miles.

  • PDF

Application of automatic dry chemistry analyzer (FUJI DRI-CHEM 3000) used to hematological analysis of cultured freshwater fish in low temperature season (담수산 양식어류의 혈액검사에 사용된 건식 자동생화학 분석기 (FUJI DRI-CHEM 3000) 의 활용 가능성)

  • Jung, Sung-Hee;Seo, Jung-Soo;Kim, Jin-Do;Choi, Hye-Sung;Park, Myoung-Ae
    • Journal of fish pathology
    • /
    • v.24 no.3
    • /
    • pp.247-254
    • /
    • 2011
  • The purpose of this study was to obtain reference data of parameters for hematological health diagnosis in cultured freshwater fish and also evaluate application of automatic dry-type chemistry analyzer (FUJI DRI-CHEM 3000) used to those blood tests. A blood profile of total 200 fish for rainbow trout (Onchorhynchus mykiss), israel carp (Cyprinus carpio), tilapia (Oreochromis niloticus) and eel (Anguilla japonica) cultured in Inland Fisheries Research Institute of NFRDI was determined by hemoglobin (Hb) and plasma chemistry tests: total protein (TP), albumin (ALB), alkaline phosphatase (ALP), blood urea nitrogen (BUN), lactate dehydrogenase (LDH), triglyceride (TG), total cholesterol (TCHO), creatinine (CRE), aspartate aminotransferase (AST), alanine aminotransferase (ALT), glucose (GLU). The values of ALT, TG, LDH, ALB, TCHO, AST and ALP were outside from the minimum and/or maximum of the established detectable range of the analyzer. ALT and TG were not detectable in the range of 67%~61.5%. LDH, ALB and TCHO were not detectable in the range of 36~17%. AST and ALP were not detectable in the range of 5.5~0.5%. However, the values of BUN, CRE, GLU, Hb and TP were below the detectable limits of the analyzer.

Studies on the Residues of Carbamate Pesticide in Fruits and Vegetables (과일 및 야채의 Carbamate계 농약의 잔류량)

  • 이해금;최용순;최규열
    • Journal of Food Hygiene and Safety
    • /
    • v.2 no.1
    • /
    • pp.3-8
    • /
    • 1987
  • ABSTRACT-Agricultural products collected from the suburbs of Chuncheon in 1984 were analyzed for carbamate pesticides by GLC-NPD. O-tert-butyl phenyl methyl carbamate(BPMC) was detected in most samples and their residue levels in strawberry, tomato, cucumber, grape, apple and chinese cabbage were in the range of non-detectable to 0.2356 ppm(Av. 0.0539 ppm). 1- naphthyl methyl carbamate(N AC) were detected in cucumber, grape and chinese cabbage and their residue levels were in the range of non-detectable to 0.0265 ppm. O-cumeryl methyl carbamate(MIPC) was detected in only chinese cabbage and its residue levels were in the range of non-detectable to 0.0059 ppm. Detection frequencies of BPMC, MIPC and NAC in the chinese cabbage were higher than those the others.others.

  • PDF

An Experimental Study on Detecting materials of GPR for Maintenance of Restored Cavities (복구된 공동의 유지관리를 위한 GPR 탐사용 탐지물질에 관한 실험적 연구)

  • Park, Jeong Jun;Shin, Eun Chul;Park, Kwang Seok;Shin, Hee Soo;Hong, Gigwon
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.430-439
    • /
    • 2018
  • Purpose: The purpose of this study is to verify the effectiveness of maintenance method using GPR exploration by buried detective materials in the ground for efficient maintenance of recovered cavities. Method: EMI sheet, EMI paint, and ferronickel slag were used as the detection materials, and the experiment was conducted by varying the size and depth of the buried detectable material. Results: As a result of the exploration, Detectable influence range by GPR exploration was found depending on the size and depth of buried detectable material in all materials, and the possibility of using it as a detection material was confirmed.

Compact Infrared/Visible Laser Transmitter Featuring an Extended Detectable Trajectory

  • Kim, Haeng-In;Lee, Hong-Shik;Lee, Sang-Shin
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.331-335
    • /
    • 2012
  • A miniaturized laser beam transmitter, in which a visible laser module at ${\lambda}$=650 nm is precisely stacked upon an infrared (IR) module at ${\lambda}$=905 nm, has been proposed and constructed to provide an IR collimated beam in conjunction with a collinear monitoring visible beam. In particular, the IR beam is selectively dispersed through a perforated sheet diffuser, so as to create a rapidly diverging close-range beam in addition to a highly defined long-range beam simultaneously. The complementary close-range beam plays a role in mitigating the blind region in the vicinity of the transmitter, which is inevitably missed by the main long-range beam, thereby uniformly extending the transmitter's effective trajectory that is sensed by a receiver. The proposed transmitter was designed through numerical simulations and then fabricated by incorporating a diffuser sheet, perforated with an aperture of 2 mm. For the manufactured transmitter, the IR long-range beam was observed to have divergences of ~2.3 and 1.6 mrad in the fast and slow axes, respectively, while the short-range beam yielded a divergence of ~24 mrad. The angular alignment between the long-range IR and visible beams was as accurate as ~0.5 mrad. According to an outdoor feasibility test involving a receiver, the combination of the IR long- and short-range beams was proven to achieve a nearly uniform trajectory over a distance ranging up to ~600 m, with an average detectable cross-section of ${\sim}60{\times}80cm^2$.

Application of Veterinary Chemistry Analyzer used to Hematological Analysis of Marine fish Cultured in Floating Netcage (해상가두리 양식장 어류의 혈액 검사에 사용된 동물용 생화학 분석장치의 활용 가능성)

  • Jung, Sung-Hee;Jee, Bo-Young;Byun, Soon-Gyu;Choi, Hye-Sung
    • Journal of fish pathology
    • /
    • v.19 no.3
    • /
    • pp.253-265
    • /
    • 2006
  • The purpose of this study was to obtain reference data of parameters for hematological health diagnosis in marine fish and also evaluate application of veterinary chemistry analyzer used to those blood tests. A blood profile of total 522 fish for black rockfish (Sebastes schlegeli), red seabream (Pagrus major), rock bream (Oplegnathus fasciatu) and black seabream (Acanthopagrus schlegeli) cultured in mari-floating netcage of Gyeongnam province was determined by hematocrit (Ht), hemoglobin (Hb) and blood chemistry tests (total protein, albumin, alkaline phosphatase, blood urea nitrogen, lactate dehydrogenase, triglyceride, total cholesterol, creatinine, aspartate aminotransferase, alanine aminotransferase, glucose). Ht was measured by microhematocrit method. Hb and plasma chemistry were analysed by establishing baseline ranges for a dry chemical system of FUJI DRI-CHEM 3000. Actually recorded values of Hb and plasma chemistry by the analyzer were notably outside from the minimum and/or maximum of the established reference value. Albumin and alanine aminotransferase were not detectable in the range of 68~66%. Lactate dehydrogenase, total protein, alkaline phosphatase and glucose were not detectable in the range of 42~21%. Total cholesterol, aspartate aminotransferase, triglyceride, hemoglobin and creatinine were not detectable in the range of 18~3%. However, the values of blood urea nitrogen were below the detectable limits of the analyzer.

Comparision of TTC-II and disk assay method for the detection of antibiotic residues in milk (우유내 잔류물질 검사방법인 TTC-II법 및 Disk assay법의 비교시험)

  • 이정아;이은미;이성해;도재철;박영구
    • Korean Journal of Veterinary Service
    • /
    • v.22 no.1
    • /
    • pp.93-101
    • /
    • 1999
  • This test process on screening method for the detection of residual antibiotics in milk is simple, economic, sensitive to residual antibiotics and was given approval international organs. Thus, this study was carried out the comparison of Disk assay method and TTC-II method for sensitivity and minimum detectable range of antibiotics in raw milk. The results of this study was summarized as follows ; 1. The number of samples requested for treatment of mastitis was 198 samples. Comparison or analytical results among the methods of TTC-II, disk assay and Delve sp was that TTC-II 37 samples(18.6% ), Disk assay 125samples(63.1%), Delve SP 130 samples(65.7% ) reacted positively. Conformity rate of Delve SP and Disk assay was 70%. 2. Detectable limits of disk assay method in some antibiotics were more sensitive than those of official method(0.05-0.0025ppm in the $\beta$-lactams, 1ppm in two aminoglycoside, 0.2 ppm in one tetracycline, similar in one macrolide) 3. For sensitivity of residual sulfonamides TTC-II was much more sensitive than disk assay. Detectable limits of sulfamethazine and sulfadimethoxine were 30 to 50ppm levels. 4. The best medium preservation period is 1-2 days. 5. Concentration of brome cresol purple related to resistance for B stearothermophilus culture was 24ppm/ml. These results show that disk assay method for screening detection of antibiotics residuces in milk is worthy of use.

  • PDF

Development of a Zero Velocity Detectable Sensor Algorithm with Dual Incremental Encoders (정지 속도 검출 가능한 이중 증분 엔코더 센서 알고리즘 개발)

  • Lee, Se-Han;Kim, Byoung-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.1
    • /
    • pp.82-88
    • /
    • 2009
  • The output of the encoder is a digital pulse, which is also easy to be connected to a digital controller. There are various angular velocity detecting methods of M, T, and M/T. Each of them has its own properties. There is a common limitation that the angular velocity detection period is strongly dependent on the destination velocity magnitude in case of ultimate low range. They have ultimately long detection period or cannot even detect angular velocity at near zero velocity. This paper proposes a zero velocity detectable sensor algorithm with the dual encoder system. The sensor algorithm is able to keep detection period moderately at near zero velocity and even detect zero velocity within nominal period. It is useful for detecting velocity in case of changing rotational direction at which there occurs zero velocity. In this paper, various experimental results are shown for the algorithm validity.

Improvement of Processing Speed of the Doppler Filter in a Low Power Radar (저 출력 레이더의 도플러필터의 처리속도 개선)

  • Park, Jeong-Ho;Jeong, Hong
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.167-170
    • /
    • 2001
  • A low power pulse Doppler radar should integrate a large number of data to provide a required maximum detectable distance. Doppler filter needs a window that has good out-of-bard rejection level to maintain high dynamic range. From these facts, we can apply decimation and presumming to increase the speed of Doppler processing. This Paper investigates the efficiencies of several decimation methods and the loss of presumming. And I propose a method to increase processing speed but to maintain the maximum detectable distance.

  • PDF

The Measurement and Application of the Minimum Detectable Irradiance for the Infrared Point Source Detection System (적외선 점광원 탐지장비의 최소탐지조도 측정 및 활용)

  • Kim, Hyun-Sook;Yang, Yu-Kyung;Park, Yong-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • A procedure and method for the MDI(Minimum Detectable Irradiance) measurement of an infrared point source detection system is described in detail and its experimental result is analyzed. The proposed measurement method for MDI can be realized with a collimator in the laboratory environment. In addition, an estimation method of the maximum detection range of the infrared point source detection system is introduced and its performed result is shown.