A large number of the set-nets are set in Namhaedo coast of Korea. The floats of these set-nets are not only small even in case of large floats but also they scarcely have distinguishable marks such as light buoys or flags, so that they are very hard to be recognized by naked eyes and thus became probable obstacles to navigation for the passing ships and the fishing vessels. In order to research the capability of detecting such nets with Radar, the author investigated a maximum detectable range of the ordinarly large floatsand of a floating corner reflectors of various size and shape by Radar. The results obtained are as follows; 1. A maximum detectable range of large floats at a close range can be calculated by the Radar equation in sufficient accuracy. 2. Large floats of the large set-nets are also detectable by Radar even though it's detectable range boundary was within 0.2-0.65 miles. And the Radar picture of large floats was easier to be found with somewhat higher setting of the gain control on shorter range scale of the 1 mile. 3. Floating corner reflector rather suitable for set-net floats of "S" type reflector proposed in this paper, of which the dimension must be above 17cm in diameter to be detectable by Radar at 2 miles.t 2 miles.
The purpose of this study was to obtain reference data of parameters for hematological health diagnosis in cultured freshwater fish and also evaluate application of automatic dry-type chemistry analyzer (FUJI DRI-CHEM 3000) used to those blood tests. A blood profile of total 200 fish for rainbow trout (Onchorhynchus mykiss), israel carp (Cyprinus carpio), tilapia (Oreochromis niloticus) and eel (Anguilla japonica) cultured in Inland Fisheries Research Institute of NFRDI was determined by hemoglobin (Hb) and plasma chemistry tests: total protein (TP), albumin (ALB), alkaline phosphatase (ALP), blood urea nitrogen (BUN), lactate dehydrogenase (LDH), triglyceride (TG), total cholesterol (TCHO), creatinine (CRE), aspartate aminotransferase (AST), alanine aminotransferase (ALT), glucose (GLU). The values of ALT, TG, LDH, ALB, TCHO, AST and ALP were outside from the minimum and/or maximum of the established detectable range of the analyzer. ALT and TG were not detectable in the range of 67%~61.5%. LDH, ALB and TCHO were not detectable in the range of 36~17%. AST and ALP were not detectable in the range of 5.5~0.5%. However, the values of BUN, CRE, GLU, Hb and TP were below the detectable limits of the analyzer.
ABSTRACT-Agricultural products collected from the suburbs of Chuncheon in 1984 were analyzed for carbamate pesticides by GLC-NPD. O-tert-butyl phenyl methyl carbamate(BPMC) was detected in most samples and their residue levels in strawberry, tomato, cucumber, grape, apple and chinese cabbage were in the range of non-detectable to 0.2356 ppm(Av. 0.0539 ppm). 1- naphthyl methyl carbamate(N AC) were detected in cucumber, grape and chinese cabbage and their residue levels were in the range of non-detectable to 0.0265 ppm. O-cumeryl methyl carbamate(MIPC) was detected in only chinese cabbage and its residue levels were in the range of non-detectable to 0.0059 ppm. Detection frequencies of BPMC, MIPC and NAC in the chinese cabbage were higher than those the others.others.
Park, Jeong Jun;Shin, Eun Chul;Park, Kwang Seok;Shin, Hee Soo;Hong, Gigwon
Journal of the Society of Disaster Information
/
v.14
no.4
/
pp.430-439
/
2018
Purpose: The purpose of this study is to verify the effectiveness of maintenance method using GPR exploration by buried detective materials in the ground for efficient maintenance of recovered cavities. Method: EMI sheet, EMI paint, and ferronickel slag were used as the detection materials, and the experiment was conducted by varying the size and depth of the buried detectable material. Results: As a result of the exploration, Detectable influence range by GPR exploration was found depending on the size and depth of buried detectable material in all materials, and the possibility of using it as a detection material was confirmed.
A miniaturized laser beam transmitter, in which a visible laser module at ${\lambda}$=650 nm is precisely stacked upon an infrared (IR) module at ${\lambda}$=905 nm, has been proposed and constructed to provide an IR collimated beam in conjunction with a collinear monitoring visible beam. In particular, the IR beam is selectively dispersed through a perforated sheet diffuser, so as to create a rapidly diverging close-range beam in addition to a highly defined long-range beam simultaneously. The complementary close-range beam plays a role in mitigating the blind region in the vicinity of the transmitter, which is inevitably missed by the main long-range beam, thereby uniformly extending the transmitter's effective trajectory that is sensed by a receiver. The proposed transmitter was designed through numerical simulations and then fabricated by incorporating a diffuser sheet, perforated with an aperture of 2 mm. For the manufactured transmitter, the IR long-range beam was observed to have divergences of ~2.3 and 1.6 mrad in the fast and slow axes, respectively, while the short-range beam yielded a divergence of ~24 mrad. The angular alignment between the long-range IR and visible beams was as accurate as ~0.5 mrad. According to an outdoor feasibility test involving a receiver, the combination of the IR long- and short-range beams was proven to achieve a nearly uniform trajectory over a distance ranging up to ~600 m, with an average detectable cross-section of ${\sim}60{\times}80cm^2$.
The purpose of this study was to obtain reference data of parameters for hematological health diagnosis in marine fish and also evaluate application of veterinary chemistry analyzer used to those blood tests. A blood profile of total 522 fish for black rockfish (Sebastes schlegeli), red seabream (Pagrus major), rock bream (Oplegnathus fasciatu) and black seabream (Acanthopagrus schlegeli) cultured in mari-floating netcage of Gyeongnam province was determined by hematocrit (Ht), hemoglobin (Hb) and blood chemistry tests (total protein, albumin, alkaline phosphatase, blood urea nitrogen, lactate dehydrogenase, triglyceride, total cholesterol, creatinine, aspartate aminotransferase, alanine aminotransferase, glucose). Ht was measured by microhematocrit method. Hb and plasma chemistry were analysed by establishing baseline ranges for a dry chemical system of FUJI DRI-CHEM 3000. Actually recorded values of Hb and plasma chemistry by the analyzer were notably outside from the minimum and/or maximum of the established reference value. Albumin and alanine aminotransferase were not detectable in the range of 68~66%. Lactate dehydrogenase, total protein, alkaline phosphatase and glucose were not detectable in the range of 42~21%. Total cholesterol, aspartate aminotransferase, triglyceride, hemoglobin and creatinine were not detectable in the range of 18~3%. However, the values of blood urea nitrogen were below the detectable limits of the analyzer.
This test process on screening method for the detection of residual antibiotics in milk is simple, economic, sensitive to residual antibiotics and was given approval international organs. Thus, this study was carried out the comparison of Disk assay method and TTC-II method for sensitivity and minimum detectable range of antibiotics in raw milk. The results of this study was summarized as follows ; 1. The number of samples requested for treatment of mastitis was 198 samples. Comparison or analytical results among the methods of TTC-II, disk assay and Delve sp was that TTC-II 37 samples(18.6% ), Disk assay 125samples(63.1%), Delve SP 130 samples(65.7% ) reacted positively. Conformity rate of Delve SP and Disk assay was 70%. 2. Detectable limits of disk assay method in some antibiotics were more sensitive than those of official method(0.05-0.0025ppm in the $\beta$-lactams, 1ppm in two aminoglycoside, 0.2 ppm in one tetracycline, similar in one macrolide) 3. For sensitivity of residual sulfonamides TTC-II was much more sensitive than disk assay. Detectable limits of sulfamethazine and sulfadimethoxine were 30 to 50ppm levels. 4. The best medium preservation period is 1-2 days. 5. Concentration of brome cresol purple related to resistance for B stearothermophilus culture was 24ppm/ml. These results show that disk assay method for screening detection of antibiotics residuces in milk is worthy of use.
Journal of Institute of Control, Robotics and Systems
/
v.15
no.1
/
pp.82-88
/
2009
The output of the encoder is a digital pulse, which is also easy to be connected to a digital controller. There are various angular velocity detecting methods of M, T, and M/T. Each of them has its own properties. There is a common limitation that the angular velocity detection period is strongly dependent on the destination velocity magnitude in case of ultimate low range. They have ultimately long detection period or cannot even detect angular velocity at near zero velocity. This paper proposes a zero velocity detectable sensor algorithm with the dual encoder system. The sensor algorithm is able to keep detection period moderately at near zero velocity and even detect zero velocity within nominal period. It is useful for detecting velocity in case of changing rotational direction at which there occurs zero velocity. In this paper, various experimental results are shown for the algorithm validity.
A low power pulse Doppler radar should integrate a large number of data to provide a required maximum detectable distance. Doppler filter needs a window that has good out-of-bard rejection level to maintain high dynamic range. From these facts, we can apply decimation and presumming to increase the speed of Doppler processing. This Paper investigates the efficiencies of several decimation methods and the loss of presumming. And I propose a method to increase processing speed but to maintain the maximum detectable distance.
A procedure and method for the MDI(Minimum Detectable Irradiance) measurement of an infrared point source detection system is described in detail and its experimental result is analyzed. The proposed measurement method for MDI can be realized with a collimator in the laboratory environment. In addition, an estimation method of the maximum detection range of the infrared point source detection system is introduced and its performed result is shown.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.