• 제목/요약/키워드: Desulfurization efficiency

검색결과 87건 처리시간 0.029초

Ferrate(VI)를 이용한 발전소 탈황폐수 처리에 관한 연구 (A study on the desulfurization wastewater treatment using Ferrate(VI))

  • 조은영;박찬규
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.297-301
    • /
    • 2017
  • Wastewater treatment using ferrate (VI) solution is becoming a promising technology for several years, because it is high efficient and harmless technology. In this study, the ferrate (VI) solution was tested to treatment of desulfurization wastewater. The effluent from desulfurization wastewater treatment process of power plant was used as raw water, and the COD and T-N removal efficiency of ferrate(VI) solution were investigated. In the test, as the injection rate increased from 0.1 to 1.0%, the removal efficiency of COD also slightly increased, about 80% of COD were removed in 1.0% of injection rate. In the case of T-N, about 50% of T-N was removed in the condition of 1.0% of injection rate. The removal efficiency of COD and T-N also affected by reaction time, maximum removal efficiency was shown in 30 min of treatment. From these results, the wastewater treatment with ferrate(VI) solution can be great solutions for treatment of non-biodegradable pollutants in wastewater, especially for the 3rd treatment of wastewater.

유동층연소로에서 유,무연탄 혼합연소시 탈황에 관한 연구 --- 폐제지슬러지를 이용한 황산화물 제어 --- (A study on desulfurization by anthracite - bituminous coal blend combustion in a fluidized bed combustor --- A desulfurization using waste paper sludge ---)

  • 조상원;오광중
    • 청정기술
    • /
    • 제3권1호
    • /
    • pp.96-105
    • /
    • 1997
  • 본 연구는 유,무연탄 혼합 유동층 석탄연소로에서 폐제지슬러지를 탈황제로 사용하였을 경우 석회석 입자크기, 주입공기 유속, Ca/S 몰비, 무연탄비, 층온도 등에 따른 $SO_2$ 제거 효율에 관해 연구하였으며, 실험결과는 다음과 같다. 폐제지슬러지의 입자크기는 탈황율에 매우 큰 영항을 주는 것으로 나타났으며, 입자크기 $1016{\mu}m$ 일 때 가장 높은 탈황율을 보였고, 주입되는 공기의 유속변화에 따른 탈황율에는 큰 차이가 없었다. Ca/S 몰비가 증가할수록 탈황율도 증가하였으며, Ca/S 몰비 3까지는 급격히 탈황율이 증가하였으나 3이상에서는 큰 차이가 없었으므로 Ca/S 몰비는 3이 적절한 것으로 나타났다. 또한, 층온도는 탈황율에 큰 영향을 주는 것으로 나타나 $800^{\circ}C$에서 가장 높은 탈황율을 보였으며, 무연탄비가 증가할수록 탈황율이 약간 증가하는 것으로 나타났다. 따라서, 유,무연탄 혼합연소시 폐제지슬러지는 매우 높은 탈황율을 보여 탈황제로서의 가능성을 확인할 수 있었다.

  • PDF

Design of gas suspension absorber to improve desulfurization efficiency

  • Hwang, Woohyeon;Lee, Kyung-Ok
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권2호
    • /
    • pp.189-195
    • /
    • 2020
  • 본 연구에서는 배기가스가 흡수탑으로 균일하게 유입될 수 있도록 가스 부유식 흡수탑의 입구덕트와 안내깃을 다시 설계하여 탈황효율을 높이고자 한다. 산업용 보일러에서 대기오염 물질의 주 발생원인 중에서 황산화물의 오염물질을 저감하기 위해 기존의 장치를 다시 설계하여 해결하고자 한다. 이를 위하여 가스 부유식 흡수탑 내부에서 배기가스 중에 SOx 성분의 제거효율을 높일 수 있도록 배기가스, 슬러리와 재순환 흡착제가 균일하게 접촉하도록 변경한다. 그리고 보일러 출구에서부터 가스 부유식 흡수탑 출구까지 압력손실에 대한 초기 설계값과 CFD 값을 비교하여 검증한다. 또한 배기가스의 속도분포, 재순환 흡착제 농도분포, 액상 슬러리 거동, 압력손실을 각각 비교하였다. 그 결과는 보일러 출구에서부터 흡수탑 출구까지 압력손실이 감소하고, 배기가스의 편향이 최소화되므로 인해 탈황 효율이 개선되었음을 확인하였다.

국내 탈황용 석회석의 분쇄성 지수 평가 및 응용 (Evaluation and application of grinding index of domestic desulfurization limestone)

  • 서준형;백철승;조진상;안영준;안지환;조계홍
    • 에너지공학
    • /
    • 제28권1호
    • /
    • pp.1-9
    • /
    • 2019
  • 석탄 화력발전소의 배연탈황공정에서 탈황용 흡수제로 사용하는 석회석을 대상으로 본드의 분쇄일지수(BWI) 및 하드그로브지수(HGI) 측정 후 분쇄효율을 비교하였다. 측정결과, 국내 탈황용 석회석의 분쇄성지수는 HGI가 증가함에 따라 BWI가 감소하는 선형적인 반비례 관계를 확인할 수 있었으며, 석회석의 화학조성 및 채광위치에 따른 결정구조에 따라 분쇄효율의 차이가 발생하였다. 이에 따라, 석회석의 분쇄성을 측정할 경우 측정방법이 까다롭고 시간이 오래 걸리는 BWI 보다 간편하게 측정할 수 있는 HGI를 활용하여도 시료의 분쇄성 차이를 확인할 수 있을 것으로 사료되며, 분쇄 특성에 따른 석회석의 선택적 활용 시 탈황효율 또한 향상시킬 수 있을 것으로 판단된다.

석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가 (Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles)

  • 이기혁;김문원;류태우;육세진
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.

전해처리법에 의한 탈황폐수 중의 COD 및 총 질소 제거 (Electrochemical Treatment of COD and T-N in Wastewater from Flue Gas Desulfurization Process)

  • 차고은;노다지;서정현;임준혁;이태윤;이제근
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1073-1078
    • /
    • 2013
  • This paper presents the results of the electrochemical treatment of chemical oxygen demand(COD) and total nitrogen(T-N) compounds in the wastewater generated from flue gas desulfurization process by using a lab-scale electrolyzer. With the increase in the applied current from 0.6 Ah/L to 1.2 Ah/L, the COD removal efficiency rapidly increases from 74.5% to 96%, and the T-N removal efficiency slightly increases from 37.2% to 44.9%. Therefore, it is expected that an electrochemical treatment technique will be able to decrease the amount of chemicals used for reducing the COD and T-N in wastewater of the desulfurization process compared to the conventional chemical treatment technique.

산화철을 이용한$H_2S$ 제거 ($H_2S$ Desulfurization Using Iron Oxide Sorbent)

  • B.K. Kho;Lee, W.R.;Kim, H.J.;Lee, W.M.
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2000년도 추계 학술발표회 논문집
    • /
    • pp.73-77
    • /
    • 2000
  • A great deal of research has been carried out in the last twenty some years to develop high temperature desulfurization. For example, the efficiency of advanced power generation processes based on the integrated gasification combined cycle (IGCC) can be increased significantly with high temperature desulfurization. Much of the recent high temperature desulfurization research has concentrated on zinc-based sorbents such as zinc ferrite(ZnFe$_2$O$_4$) and zinc titanate(ZnO.xTiO$_2$) due to its thermodynamic advantage in capturing H$_2$S molecules.(omitted)

  • PDF

유동층보일러형 화력발전소의 석회석 활용 탈황기술 연구동향 (A Review of Desulfurization Technology using Limestone in Circulating Fluidized Bed Boiler Type Power Plant)

  • 백철승;서준형;안지환;한춘;조계홍
    • 자원리싸이클링
    • /
    • 제24권5호
    • /
    • pp.3-14
    • /
    • 2015
  • 청정석탄발전기술 중 하나인 순환유동층보일러(CFBC) 기술의 고도화에 따라 국내외 로내탈황 기술개발 현황과 국내외 유동층보일러용 석회석의 탈황특성 연구현황을 조사하였다. 석회석계 탈황제는 고온탈황특성이 우수한 원소 중 하나로 $850-950^{\circ}C$ 내외에서 최적의 탈황특성을 가지고 있다. 그리고, 탈황시험방법에 따라 흡수제 표면의 격막의 확산반응, 입자의 크기, 기공의 수량, 크기 및 구조에 의한 탈황공정의 효율성을 결정할 수 있다. 2015년 이후 대형 순환유동층형발전소의 본격적인 가동에 따라 석회석의 광상학적, 결정학적 특성 및 소성특성과 연계된 추가적인 연구가 필요한 것으로 사료된다.

유기산 첨가제를 이용한 저품질 석회석 슬러리의 탈황 성능 개선 (Improvement of Desulfurization Performance of Low-grade Limestone Slurry Using Organic Acid Additives)

  • 정지은;조인아;이창용
    • 공업화학
    • /
    • 제32권2호
    • /
    • pp.190-196
    • /
    • 2021
  • 저품질 석회석의 탈황 성능 개선을 알아보기 위해 초산, 젖산, 개미산 등 3종의 유기산 첨가제를 사용하여 기포형 반응기에서 탈황 반응을 수행하였다. 유기산이 첨가되지 않은 석회석 슬러리는 pH 5.2 이하에서 초기 탈황 효율의 저하가 일어났다. 반면, 유기산이 첨가된 석회석 슬러리는 pH 4.2~4.5에서 안정된 초기 탈황 효율을 나타내었다. 슬러리 pH 4 이하에서 유기산이 첨가된 석회석 슬러리의 탈황 성능은 유기산의 해리에 의해 생성된 음이온의 양과 연관될 수 있다. 슬러리 중 유기산의 음이온 양이 많으면 슬러리 pH의 완충 기능 저하가 급격히 일어나지 않았다. 이와 같은 결과들은 유기산의 산성도 및 해리도에 기인하였다. 3종의 유기산 첨가에 따른 저품질 석회석 슬러리의 탈황 성능 증가율은 초산(2.6%) < 젖산 (6.4%) < 개미산 (16.7%) 순으로 나타났다.

순산소연소 조건에서 Drop tube furnace를 이용한 운전변수에 따른 석회석의 탈황특성 연구 (Study on the Desulfurization Characteristic of Limestone Depending on the Operating Parameters of In-Furnace Desulfurization for Oxy-Fuel Combustion Using Drop Tube Furnace)

  • 최욱;조항대;최원길;박영성;길상인;이형근
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.857-864
    • /
    • 2011
  • 순산소연소는 높은 연소 효율과 적은 배가스량, 낮은 질소산화물 농도를 장점으로 하고 있으며 연소온도 조절을 위한 배가스 재순환에 의해 배출되는 연소가스중의 $CO_2$ 농도를 95%까지 농축이 가능하므로 석탄 연소설비에 대한 유망한 CCS 기술로 부각되고 있다. 본 연구는 순산소연소 조건에서 배가스의 재순환을 통한 $CO_2$ 농도 증가에 기인하는 직접 황화반응이 탈황효율에 미치는 영향을 평가하고 반응온도, $CO_2$ 농도, $SO_2$ 농도상승이 $SO_2$ 제거효율에 미치는 영향과 배가스 중 수분 등이 $SO_2$ 제거효율에 미치는 영향을 실험적으로 고찰하였다. 반응온도 $1,200^{\circ}C$까지 온도 상승에 따라 $SO_2$의 제거효율은 증가하였고 Ca/S비, $CO_2$ 농도와 수분이 증가할수록 $SO_2$ 제거효율이 증가하였다. 이러한 운전변수는 영향인자 평가를 통하여 Ca/S 비>체류시간>$O_2$농도>반응온도>$SO_2$농도>$CO_2$농도>수분농도의 순으로 탈황반응에 영향을 미치는 것으로 나타났다. 또한 운전변수별 실험결과를 이용하여 로내 건식탈황에 있어서 각 운전변수별 성능 영향인자를 평가할 수 있는 반경험적 모델식을 도출하였다.