• Title/Summary/Keyword: Desorption gas

Search Result 255, Processing Time 0.02 seconds

The Analysis of Volatile Organic Compounds in Water by Using the Purge-and-Trap and the Gas Chromatography/Mass Selective Detector with Modified Indirect Coupling (퍼지-트랩장치와 변형된 간접 결합기를 부착한 기체크로마토그래피/질량 선택성 검출기를 이용한 물중의 휘발성 유기화합물의 분석)

  • 정영자
    • The Korean Journal of Food And Nutrition
    • /
    • v.12 no.2
    • /
    • pp.191-191
    • /
    • 1999
  • A Purge & Trap Concentrator was used to analyze various volatile organic compounds(VOCs) in wat-er. The object of this study was to observe the purge efficiency of 40 VOCs in water according to the change of parameters (purge time drypurge time sample temperature) and to determine the optimum condition for VOCs using the purge & Trap concentrator interfaced with a narrow capillary connected to a gas chromatography/mass spectrometry. The optimum condition of purge and trap is as follows: purge time at 11min drypurge time at 5min sample temperature at 6$0^{\circ}C$ at constant purge flow (40mol/min) constant desorption flow(20ml/min) desorption temperature(2$25^{\circ}C$) and desorption time (1min) At this analytical condition the detection limits of VOCs was in the range of 0.1~0.5$\mu$g/ml and the purge efficiency of each compound was over 70%.

A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector (열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가)

  • 박정근;유기호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

Determination of Methyl Bromide Used for the Preservation of Cultural Materials from Insects

  • Lee, Gil-Seung;Shin, Ueon-Sang;Shin, Ho-Sang
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.4
    • /
    • pp.27-30
    • /
    • 2002
  • A thermal desorption-gas chromatography/mass spectrometric method was developed for the determination of methyl bromide in fumes formed during preservation of cultural materials from insects. Methyl bromide in lunes was collected by drawing 10ι of air through the adsorbent tube filled with a solid adsorbent (Chromosorb). The air samples were analyzed by using a special thermal desorption device and GC/MS determination. The recovery of methyl bromide by air sampling was 88% and the detection limit of the assay was 0.1 pptv based upon assayed air of 10ι. The method was applied to the determination of fumed methyl bromide used for the preservation of papers in a library. The mean concentration of methyl bromide determined in a library was 280.2 $\pm$ 25.4 pptv.

Electrical Characteristic Change of Al/Pd Film by Hydrogen Gas (수소 기체에 의한 Al/Pd 박막의 전기 특성 변화)

  • Cho, Young-Sin
    • Journal of Hydrogen and New Energy
    • /
    • v.16 no.4
    • /
    • pp.386-390
    • /
    • 2005
  • Al film(135.5 nm thick) with Pd film(39.6 nm thick) on the top of it was made by thermal evaporation method. Electrical resistance change due to hydrogen absorption and desorption was measured by four point measurement method. The sample was activated by hydrogen absorption and desorption cycling at room temp. Hydrogen was introduced into the film by increasing hydrogen gas pressure step by step up to 640 torr at room temp. The resistance change ratio was decreased to 12 % with increasing hydrogen pressure in contrast to normal metal behavior. This strange tendency was not understood yet. Further study is needed to find out the mechanism of hydrogen absorption in Al in Al/Pd film.

Analysis of Organic Compounds in Ambient PM2.5 over Seoul using Thermal Desorption-comprehensive Two Dimensional Gas Chromatography-time of Flight Mass Spectrometry (TD-GCxGC-TOFMS) (Thermal Desorption-comprehensive Two Dimensional Gas Chromatography-time of Flight Mass Spectrometry (TD-GCxGC-TOFMS)을 이용한 서울 대기 중 PM2.5 유기성분 분석)

  • Lee, Ji-Yi;Lane, Douglas A.;Huh, Jong-Bae;Yi, Sung-Muk;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.420-431
    • /
    • 2009
  • Characteristics and advantages of the thermal desorption-comprehensive two dimensional gas chromatography-time of flight mass spectrometry (TD-GCxGC-TOFMS) were discussed and the organic compound's analysis result was shown for the ambient $PM_{2.5}$ sample collected in Seoul, Korea. Over 10,000 individual organic compounds were separated from about $70{\mu}g$ of aerosols in a single procedure with no sample pre-treatment. Among them, around 300 compounds were identified and classified based on the mass fragmentation patterns and GCxGC retention times. Several aliphatic compounds groups such as alkanes, alkenes, cycloalkanes, alkanoic acids, and alkan-2-ones were identified as well as 72 PAH compounds including alkyl substituted compounds and 8 hopanes. In Seoul aerosol, numerous oxidized aromatic compounds including major components of secondary organic aerosols were observed. The inventory of organic compounds in $PM_{2.5}$ of Seoul, Korea suggested that organic aerosol were constituted by the compounds of primary source emission as well as the formation of secondary organic aerosols.

A Study of Benzene Desorption Characteristics Using Steam on Activated Carbon (벤젠이 흡착된 활성탄의 수증기에 의한 탈착특성 연구)

  • Kwon, Jun Ho;Min, Byong Hoon;Suh, Sung-Sup
    • Clean Technology
    • /
    • v.12 no.4
    • /
    • pp.217-223
    • /
    • 2006
  • The operating variables of a desorption step were experimentally investigated tor the cycle of the process made up of benzene adsorption, steam desorption, and drying step. The effect of adsorbent regeneration depending on existence and nonexistence of drying step was studied by breakthrough curves obtained in the adsorption step of the second cycle. The duration of drying step was determined by the experimental results. In case that the amount of nitrogen gas was fixed, the regeneration efficiency increased with the amount of steam. However, the effect of steam decreased as the amount of nitrogen increased. Therefore, it would be possible to predict the optimum amount of steam comparing the amount of nitrogen gas with amount of steam in economic view.

  • PDF

A Study on Adsorption of Volatile Organic Compound by Activated Carbon Fiber Coated with Dielectric Heating Element and Desorption by Applying Microwave (유전가열물질을 코팅한 활성탄소섬유의 휘발성 유기화합물 흡착 및 마이크로파 인가에 의한 탈착 연구)

  • Kim, Sang-Guk;Chang, Ye-Rim
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.2
    • /
    • pp.122-132
    • /
    • 2009
  • Adsorption of toluene by activated carbon fiber (ACF) coated with dielectric heating element and desorption by applying microwave were investigated. In order to prepare adsorbent so that VOC can be desorbed by microwave heating, fine dielectric heating element with nano size was coated on the surface of the ACF using hybrid binder. Eight adsorbents (ACF-DHE, Activated Carbon Fiber coated with Dielectric Heating Element) were prepared with different amount of dielectric heating element, kinds of hybrid binder, and solvent. In order to investigate adsorption characteristics, BET surface area, pore volume, and average pore size were measured for each adsorbent including ACF. Breakthrough experiments with toluene concentration, flow rate, bed length using fixed bed reactor were performed to investigate adsorbality of adsorbent, and results were compared with that of the ACF. Desorption reactor was constructed with modified microwave oven to investigate heating effect on ACF-DHE by applying microwave power. Each adsorbent saturated with toluene were put into desorption reactor. Composition of desorbed gas generated by applying controlled microwave power to reactor was measured. Up to now, hot air desorption method has been used. Experimental results showed that desorption method with new adsorbent prepared by coating dielectric heating element on ACF can be used for industrial application.

Research on desorption and stability of benzene, toluene, acetone and n-hexane of activated carbon acquired from domestic market (국내 시판 중인 활성탄을 이용한 벤젠, 톨루엔, 아세톤 및 노말 헥산의 탈착 및 저장성 평가 연구)

  • Lee, Naroo;Yi, Gwangyong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.353-358
    • /
    • 2014
  • Purpose: This study was conducted to evaluate desorption efficiency and storage stability on activated carbon acquired form domestic market. Materials: Mixture of acetone, benzene, normal hexane and toluene was injected on four types of charcoal 100 mg. After overnight, charcoal was desorbed by carbon disulfide $1m{\ell}$ and analyzed by gas chromatography with flame ionization detector. Results: Desorption efficiency of benzene, normal hexane and toluene in charcoal tubes were 95% ~ 105%. But desorption efficiency of acetone in charcoal tubes was below 75% and different from types of charcoal. The more injected amount of acetone on charcoal showed higher desorption efficiency. Acetone injected on charcoal tubes migrated from front section into back section after 10 days storage at room temperature. Conclusions: Desorption efficiency and storage stability of activated carbon acquired from domestic market was good for benzene, normal hexane and toluene. The activated carbon acquired from domestic market has ability to be used as sampling media.

Effect of the Thermal Etching Temperature and SiO2/Al2O3 Ratio of Flexible Zeolite Fibers on the Adsorption/desorption Characteristics of Toluene

  • Ji, Sang Hyun;Yun, Ji Sun
    • Korean Journal of Materials Research
    • /
    • v.29 no.3
    • /
    • pp.143-149
    • /
    • 2019
  • To develop flexible adsorbents for compact volatile organic compound (VOC) air purifiers, flexible as-spun zeolite fibers are prepared by an electrospinning method, and then zeolite particles are exposed as active sites for VOC (toluene) adsorption on the surface of the fibers by a thermal surface partial etching process. The breakthrough curves for the adsorption and temperature programmed desorption (TPD) curves of toluene over the flexible zeolite fibers is investigated as a function of the thermal etching temperature by gas chromatography (GC), and the adsorption/desorption characteristics improves with an increase in the thermal surface etching temperature. The effect of acidity on the flexible zeolite fibers for the removal of toluene is investigated as a function of the $SiO_2/Al_2O_3$ ratios of zeolites. The acidity of the flexible zeolite fibers with different $SiO_2/Al_2O_3$ ratios is measured by ammonia-temperature-programmed desorption ($NH_3-TPD$), and the adsorption/desorption characteristics are investigated by GC. The results of the toluene adsorption/desorption experiments confirm that a higher $SiO_2/Al_2O_3$ ratio of the flexible zeolite fibers creates a better toluene adsorption/desorption performance.

Quantitative Analysis of SO2 and NO2 Adsorption and Desorption on Quartz Crystal Microbalance Coated with Cobalt Gallate Metal-Organic Framework

  • Junhyuck Ahn;Taewook Kim;Sunghwan Park;Young-Sei Lee;Changyong Yim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.147-153
    • /
    • 2023
  • Metal-organic frameworks (MOFs) of cobalt gallate were synthesized and deposited on gold electrodes using self-assembly monolayers (SAMs) and hydrothermal processing. These MOF films exhibit strong adsorption capabilities for gaseous particulates, and the use of SAMs allows the synthesis and deposition processes to be completed in a single step. When cobalt gallate is mixed with SAMs, a coordination bond is formed between the cobalt ion and the carboxylate or hydroxyl groups of the SAMs, particularly under hydrothermal conditions. Additionally, the quartz crystal microbalance (QCM) gas sensor accurately measures the number of particulates adsorbed on the MOF films in real-time. Thus, the QCM gas sensor is a valuable tool for quantitatively measuring gases, such as SO2, NO2, and CO2. Furthermore, the QCM MOF film gas sensor was more effective for gas adsorption than the MOF particles alone and allowed the accurate modeling of gas adsorption. Moreover, the QCM MOF films accurately detect the adsorption-desorption mechanisms of SO2 and NO2, which exist as gaseous particulate matter, at specific gas concentrations.