• 제목/요약/키워드: Design wind speed criteria

검색결과 32건 처리시간 0.022초

설계풍속 상향조정에 따른 레일클램프의 쐐기각에 대한 연구 (A Study on the Wedge Angle of the Rail Clamp according to the Change of the Design Wind Speed Criteria)

  • 이정명;한동섭;이성욱;심재준;한근조
    • 한국정밀공학회지
    • /
    • 제23권12호
    • /
    • pp.103-110
    • /
    • 2006
  • The rail clamp is very important device to prevent that a container crane slips along a rail due to the wind blast as well as to locate the crane in the set position during an operating mode. Recently, the design wind speed criteria were intensified from the wind speed of 16m/s to 35m/s during an operating mode, and from 50m/s to 75m/s during a stowed mode in Korea, according to the 'Inspection Criteria for Facilities and Equipments in Port' reformed after typhoon 'Maemi'. In order to design the wedge type rail clamp for the reinforced design wind speed criteria of 35m/s, we carried out the finite element analysis of the rail clamp with respect to the wedge angle, and analyzed the relationship between the wedge angle and the sliding distance of the rail clamp.

설계 풍속 상향 조정에 따른 Quay crane용 제용량 쐐기형 레일 클램프 설계 (Design of the Various Capacity Wedge-type Rail Clamp for a Quay crane According to the Design Wind Speed Criteria Change)

  • 이정명;한근조;심재준;한동섭;이성욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1626-1629
    • /
    • 2005
  • Recently many countries have concentrated their effort on the port automation, in order to be the Hub-port, that the Ultra Large Container Ship could come alongside the Quay, in their region. As the magnitude of the container ship increase, that of the Quay crane increases from 50ton-class to 61ton-class more and more. The wind speed criteria to design the structures used in the port was upgraded from 20m/s to 40m/s due to change of the weather condition. Our laboratory could have the ability to design the wedge type rail clamp for 50ton-class Quay crane in 30m/s wind speed. Accordingly we analyzed the load condition of the Quay crane about 40m/s wind speed upgraded from 20m/s and designed the wedge type rail clamp for 50ton and 61ton-class Quay crane.

  • PDF

Alternative robust estimation methods for parameters of Gumbel distribution: an application to wind speed data with outliers

  • Aydin, Demet
    • Wind and Structures
    • /
    • 제26권6호
    • /
    • pp.383-395
    • /
    • 2018
  • An accurate determination of wind speed distribution is the basis for an evaluation of the wind energy potential required to design a wind turbine, so it is important to estimate unknown parameters of wind speed distribution. In this paper, Gumbel distribution is used in modelling wind speed data, and alternative robust estimation methods to estimate its parameters are considered. The methodologies used to obtain the estimators of the parameters are least absolute deviation, weighted least absolute deviation, median/MAD and least median of squares. The performances of the estimators are compared with traditional estimation methods (i.e., maximum likelihood and least squares) according to bias, mean square deviation and total mean square deviation criteria using a Monte-Carlo simulation study for the data with and without outliers. The simulation results show that least median of squares and median/MAD estimators are more efficient than others for data with outliers in many cases. However, median/MAD estimator is not consistent for location parameter of Gumbel distribution in all cases. In real data application, it is firstly demonstrated that Gumbel distribution fits the daily mean wind speed data well and is also better one to model the data than Weibull distribution with respect to the root mean square error and coefficient of determination criteria. Next, the wind data modified by outliers is analysed to show the performance of the proposed estimators by using numerical and graphical methods.

Design criteria of wind barriers for traffic -Part 2: decision making process

  • Kim, Dong Hyawn;Kwon, Soon-Duck;Lee, Il Keun;Jo, Byung Wan
    • Wind and Structures
    • /
    • 제14권1호
    • /
    • pp.71-80
    • /
    • 2011
  • This study presents a decision making process for installation of wind barrier which is used to reduce the wind speed applied to running vehicles on expressway. To determine whether it is needed to install wind barrier or not, cost and benefit from wind barrier are calculated during lifetime. In obtaining car accidental risk, probabilistic distribution of wind speed, daily traffic volume, mixture ratio in the volume, and duration time for wind speed range are considered. It is recommended to install wind barrier if benefit from the barrier installation exceed construction cost. In the numerical examples, case studies were shown for risk and benefit calculation and main risky regions on Korean highway were all evaluated to identify the number of installation sites.

A Study on the Wedge Angle of the Rail Clamp according to the Design Wind Speed Criteria Change

  • Lee Jung-Myung;Han Dong-Seop;Han Geun-Jo;Jeon Young-Hwan
    • 한국항해항만학회지
    • /
    • 제29권7호
    • /
    • pp.641-646
    • /
    • 2005
  • In cargo-working, it unavoidably happens that the quay crane slip along the rail and the container move from side to side. Especially, they involve a lot of risk in bad weather. The rail clamp is a mooring device to prevent that the quay crane slips along the rail due to bad weather or the wind blast while the quay crane do the cargo-working And it will play a greater role in port container terminal integration and automation To design the wedge type rail clamp, it is very important to determine the wedge angle. In this study, we expect that the design wind speed of the quay crane will change over 16m/s. Assuming that the design wind speed is 40m/s, we determined the proper wedge angle of the wedge type rail clamp for the 50ton class quay crane.

200 km/h급 전차선로 구조강도 설계기준에 관한 기술적 검토 (A Technical Review on the Structure Design Criteria for a Catenary System with Maximum Design Speed of 200 km/h)

  • 조용현;이기원;권삼영;최강윤;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.273-280
    • /
    • 2001
  • In this study, a comparison between the structural design criteria for a catenary system with the maximum design speed of 100km/h and that of 300km/h was performed in order to establish that of 200km/h. According to the result, catenary design criteria for 300km/h operation is more conservative than that for 100km/h operation. This result shows that higher wind pressure and safety factor are adopted to catenary design for 300km/h operation. So, for the purpose of the economic structural design for catenary system, it is necessary to review the adoption possibility of catenary system for 100km/h operation first. In order to review the adoption possibility for catenary system for 100km/h operation, design criteria for 300km/h operation should be chosen for safer catenary structure.

  • PDF

Design criteria of wind barriers for traffic -Part 1: wind barrier performance

  • Kwon, Soon-Duck;Kim, Dong Hyawn;Lee, Seung Ho;Song, Ho Sung
    • Wind and Structures
    • /
    • 제14권1호
    • /
    • pp.55-70
    • /
    • 2011
  • This study investigates the design criteria required for wind barriers to protect vehicles running on an expressway under a high side wind. At the first stage of this study, the lateral deviations of vehicles in crosswinds were computed from the commercial software, CarSim and TruckSim, and the critical wind speeds for a car accident were then evaluated from a predefined car accident index. The critical wind speeds for driving stability were found to be 35 m/s for a small passenger car, yet 30 m/s for a truck and a bus. From the wind tunnel tests, the minimum height of a wind barrier required to reduce the wind speed by 50% was found to be 12.5% of the road width. In the case of parallel bridges, the placement of two edge wind barriers plus one wind barrier at center was recommended for a separation distance larger than 20 m (four lanes) and 10 m (six lanes) respectively, otherwise two wind barriers were recommended.

신뢰성에 기초한 송전철탑의 내풍설계기준 (Reliability-Based Wind-Resistant Design Criteria of Transmission Towers)

  • 조효남;신재철;이승재
    • 대한토목학회논문집
    • /
    • 제14권5호
    • /
    • pp.1043-1053
    • /
    • 1994
  • 본 논문에서는 태풍이나 착빙설 등 기상관련 하중을 받는 송전철탑의 실용적이고 합리적인 설계를 위하여 신뢰성에 기초한 하중저항계수설계기준(Load and Resistance Factor Design : LRFD)을 개발하였다. 이때, 설계풍하중 및 착빙하중은 송전철탑에 가해지는 풍속과 착빙설에 대한 우리나라의 가용한 통계자료를 바탕으로 MCS(Monte Carlo Simulation) 기법을 사용하여 추정하였다. 시설 송전철탑의 요소 및 체계신뢰성해석에는 AFOSM(Advanced First Order Second Moment)신뢰성방법과 IST(Importance Sampling Technique)를 사용하였다. LRFD 설계기준의 하중 및 저항계수는 합리적으로 선정된 목표 신뢰도를 기초로 AFOSM과 code 최적화기법을 사용하여 도출하였다.

  • PDF

Observational analysis of wind characteristics in the near-surface layer during the landfall of Typhoon Mujigae (2015)

  • Lin Xue;Ying Li;Lili Song
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.315-329
    • /
    • 2023
  • We investigated the wind characteristics in the near-surface layer during the landfall of Typhoon Mujigae (2015) based on observations from wind towers in the coastal areas of Guandong province. Typhoon Mujigae made landfall in this region from 01:00 UTC to 10:00 UTC on October 4, 2015. In the region influenced by the eyewall of the tropical cyclone, the horizontal wind speed was characterized by a double peak, the wind direction changed by >180°, the vertical wind speed increased by three to four times, and the angle of attack increased significantly to a maximum of 7°, exceeding the recommended values in current design criteria. The vertical wind profile may not conform to a power law distribution in the near-surface layer in the region impacted by the eyewall and spiral rainband. The gust factors were relatively dispersed when the horizontal wind speed was small and tended to a smaller value and became more stable with an increase in the horizontal wind speed. The variation in the gust factors was the combined result of the height, wind direction, and circulation systems of the tropical cyclone. The turbulence intensity and the downwind turbulence energy spectrum both increased notably in the eyewall and spiral rainband and no longer satisfied the assumption of isotropy in the inertial subrange and the -5/3 law. This result was more significant in the eyewall area than in the spiral rainband. These results provide a reference for forecasting tropical cyclones, wind-resistant design, and hazard prevention in coastal areas of China to reduce the damage caused by high winds induced by tropical cyclones.

A Study on the Sliding Distance and the Proper Position of Supporter with respect to the Wedge Angle in the Wedge Type Rail Clamp

  • Han, Dong-Seop;Han, Geun-Jo;Lee, Seong-Wook
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 Asia Navigation Conference
    • /
    • pp.115-120
    • /
    • 2006
  • The rail clamp is the device to prevent the crane slips along rails from the wind blast as well as to locate a container crane in the set position in operating mode. In this study we conduct the research for the sliding distance of rail clamp and the proper position of supporter with respect to the wedge angle in the wedge type rail clamp. The sliding distance to display the clamping force of the jaw pad corresponding to the design wind speed criteria is determined by the total displacement of the rail clamp at the roller center and the wedge angle. And the supporter is the device to prevent the overload which is applied on each part of the rail clamp by wind speed increment, because a clamping force is generated by the sliding of the wedge due to the wind. Accordingly the position of the supporter to prevent the overload is determined by analyzing the forces applied to the rail clamp. In order to analyze the sliding distance and the proper position of supporter with respect to the wedge angle as the wind speed is 40m/s, 5-kinds of wedge angles, such as 2, 4, 6, 8, $10^{\circ}$, were adopted as the design parameter.

  • PDF