• Title/Summary/Keyword: Design tensile strength

Search Result 1,000, Processing Time 0.028 seconds

Experimental study on shear, tensile, and compression behaviors of composite insulated concrete sandwich wall

  • Zhang, Xiaomeng;Zhang, Xueyong;Liu, Wenting;Li, Zheng;Zhang, Xiaowei;Zhou, Yilun
    • Advances in concrete construction
    • /
    • v.11 no.1
    • /
    • pp.33-43
    • /
    • 2021
  • A new type of composite insulated concrete sandwich wall (ICS-wall), which is composed of a triangle truss steel wire network, an insulating layer, and internal and external concrete layers, is proposed. To study the mechanical properties of this new ICS-wall, tensile, compression, and shearing tests were performed on 22 specimens and tensile strength and corrosion resistance tests on 6 triangle truss joints. The variables in these tests mainly include the insulating plate material, the thickness of the insulating plate, the vertical distance of the triangle truss framework, the triangle truss layout, and the connecting mode between the triangle truss and wall and the material of the triangle truss. Moreover, the failure mode, mechanical properties, and bearing capacity of the wall under tensile, shearing, and compression conditions were analyzed. Research results demonstrate that the concrete and insulating layer of the ICS-wall are pulling out, which is the main failure mode under tensile conditions. The ICS-wall, which uses a graphite polystyrene plate as the insulating layer, shows better tensile properties than the wall with an ordinary polystyrene plate. The tensile strength and bearing capacity of the wall can be improved effectively by strengthening the triangle truss connection and shortening the vertical distances of the triangle truss. The compression capacity of the wall is mainly determined by the compression capacity of concrete, and the bonding strength between the wall and the insulating plate is the main influencing factor of the shearing capacity of the wall. According to the tensile strength and corrosion resistance tests of Austenitic stainless steel, the bearing capacity of the triangle truss does not decrease after corrosion, indicating good corrosion resistance.

Calculation of Design parameter of Si3N4 for Engineering part through the Measurement of Tensile strength (인장강도 시험을 통한 질화규소 소재의 설계계수 계산)

  • Choi, Young-Min;Lee, Jae-Do;Ko, Jun
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.6
    • /
    • pp.709-717
    • /
    • 1996
  • Design parameter of Si3N4 for engineering part could be calculated through the measurement of tensile strength with cylindrical specimen($\Phi$=7.15, ι=110mm) Relative densities of Si3N4 test specimen prepared by pressure-less sintering (PLS) and sinter/HIP were 98.5 and 99.2% respectively. Tensile strength of Si3N4 was 378 MPa for PLS and 509 MPa for sinter/HIP. By the Weibull statistic Design parameter such as Weibull modulus m=8-12 could be calcuated. Fracture strength of Si3N4 related to volume could be effectively pridicted by using Weibull theory.

  • PDF

A Study on the Development of Grip Adapters for Developing Design Tensile Strength of Glass Fiber Reinforced Polymer Rebar (GFRP Rebar의 적정 인장강도 발현을 위한 정착구 개발에 관한 연구)

  • Park Ji-Sun;You Young-Chan;Park Young-Hwan;Kim Hyeong-Yeol;You Young-Jun;Kim Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.797-800
    • /
    • 2004
  • Some test results indicated that the current ASTM grip adapter of GFRP rebar was not successful in developing the design tensile strength of GFRP rebar with reasonable accuracy. It is because the current ASTM grip adapter of GFRP rebar does not take into account the various geometric characteristics of GFRP rebar such as surface treatment, shape of bar cross section, bar deformation as well as physical characteristics such as poisson effect, elastic modulus in the transverse direction and so on. The research reported in this paper is to provide how to proportion an adequate grip adapter to develop design tensile properties of GFRP rebar. The proposed grip adapter is derived from the equilibrium or compatibility equations. From the preliminary test results for rounded GFRP rebar, it was found that the grip adapter with specific size proportioned by proposed method shows the highest tensile strength among them.

  • PDF

Evaluation of High Temperature Tensile Properties in GTD-111DS (GTD-111DS 소재의 고온 인장 특성 평가)

  • Park H.S.;Kim H.I.;Lee Y.M.;Seok C.S.;Kim M.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1358-1362
    • /
    • 2005
  • The Ni-base superalloy GTD-111DS was designed in the 1970s and is widely used as the material of the first stage blade under a severe combination of temperature and pressure in gas turbines. But because GTD-111DS is distributed in the shape of blade and blade has a unique figure and many cooling channels, it is hard to manufacture the test specimen. In this reason, there are little data on the microstructure and mechanical properties of the alloy. Therefore through the microstructure analysis, present paper observed that the shape of $\gamma{'}$ did not change even if aging time was increased but the amount and volume of the deposition of secondary $\gamma{'}\;rose\;and\;secondary\;\gamma{'}\;grew\;among\;primary\;\gamma{'}$. Also, by tensile test for different temperature, there was difference between yield strength and tensile strength in room temperature on heat treatment and extracting region but the more increasing temperature, the more decreasing difference between yield strength and tensile strength.

  • PDF

Design of High Strength Concrete Filled Tubular Columns For Tall Buildings

  • Liew, J.Y. Richard;Xiong, M.X.;Xiong, D.X.
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.215-221
    • /
    • 2014
  • Ultra-high strength concrete and high tensile steel are becoming very attractive materials for high-rise buildings because of the need to reduce member size and structural self-weight. However, limited test data and design guidelines are available to support the applications of high strength materials for building constructions. This paper presents significant findings from comprehensive experimental investigations on the behaviour of tubular columns in-filled with ultra-high strength concrete at ambient and elevated temperatures. A series of tests was conducted to investigate the basic mechanical properties of the high strength materials, and structural behaviour of stub columns under concentric compression, beams under moment and slender beam-columns under concentric and eccentric compression. High tensile steel with yield strength up to 780 MPa and ultra-high strength concrete with compressive cylinder strength up to 180 MPa were used to construct the test specimens. The test results were compared with the predictions using a modified Eurocode 4 approach. In addition, more than 2000 test data samples collected from literature on concrete filled steel tubes with normal and high strength materials were also analysed to formulate the design guide for implementation in practice.

A Study on Engineering Characteristics of Geogrids and the Applicability in fields (지오그리드의 공학적 특성 및 설계인자 적용성 평가에 관한 연구)

  • 신은철;김두환;신동훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.105-112
    • /
    • 1999
  • In recent the superior economic benefits and the convenience of installation increased the use of geosynthetics, especially geogrids with the effects of high tensile strength. In this study, various tests were conducted to determine the physical and chemical properties of geogrids which contains durability under various critical conditions, creep behavior and the stability for installation damage in fields. With analysis of test results, the partial and total safety factors were determined and presented the long term design strength of flexible geogrids.

  • PDF

Ultimate Compressive Strength Analysis of TMCP High Tensile Steel Plates with HAZ Softening(2nd Report) (HAZ 연화부를 가진 TMCP형 고장력강판의 압축최종강도에 관한 연구 - 제 2 보)

  • 백점기;고재용
    • Journal of Welding and Joining
    • /
    • v.9 no.2
    • /
    • pp.44-50
    • /
    • 1991
  • The use of high tensile steel plates is increasing in the fabrication of ship and offshore structures. The softening region which has lower yield stress than base metal is located to prevent cracking in the conventional high tensile steel. Also, thermo mechanical control process(TMCP) steel with low carbon equivalent has the softening region which occurs in the heat affected zone when high heat input weld is carried out. The softening region in the high tensile steel gives rise to serious effect on structural strength such as tensile strength, fatigue strength and ultimate strength. In order to make a reliable structural design using high tensile steel plates, the influence of the softening on plate strength should be evaluated in advance. In the previous paper, the authors discussed the ultimate compressive strength of 50HT steel square plates with softening region. In this paper, the ultimate compressive strength with varying the yield stress of softening region and the aspect ratio of the plate is investigated by using the elasto-plastic large deformation finite element method.

  • PDF

Effect of Fiber Orientation on Failure Strength Properties of Natural Fiber Reinforced Composites including Adhesive Bonded Joint (접착제 접합된 자연섬유강화 복합재료의 파괴강도 특성에 미치는 섬유 방향의 영향)

  • Yoon, Ho-Chel
    • Journal of Welding and Joining
    • /
    • v.24 no.5
    • /
    • pp.43-48
    • /
    • 2006
  • This paper is concerned with a fracture strength study of composite adhesive lap joints. The tests were carried out on specimen joints manufactured hybrid stacked composites such as the polyester and bamboo natural fiber layer. The main objective of the work was to test the fracture strength using hybrid stacked composites with a polyester and bamboo natural fiber layer. Tensile and peel strength of hybrid stacked composites are tested before appling adhesive bonding. From results, Natural fiber reinforced composites have lower tensile strength than the original polyester. and The load directional orientation and small amount and low thickness of bamboo natural fiber layer have a good effect on the tensile and peel strength of natural fiber reinforced composites. The failure strength of these materials applied adhesive bonding is also affected by fiber orientation and thickness of bamboo natural fiber layer. There for, Fiber orientation of bamboo natural fiber layer have a great effect on the tensile-shear strength of natural fiber reinforced composites including adhesive bonded joints.

Experimental Study on the Tensile Behaviors of Stud Connection with Hanger (행거로 보강된 스터드 접합부의 인장거동에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.231-238
    • /
    • 2004
  • This paper presents the tensile behavior of the stud connection between reinforced concrete(RC) and steel members. Hanger reinforcements are placed around the studs to transfer the tensile and flexural loads to the opposite side of the concrete member. Eight specimens for the tensile tests are tested with variables, which are the arrangement details of hanger reinforcements, the reinforcing bars, and the embedment length of stud. The results of the tensile tests show that hanger reinforcements are effective to increase tensile strength for stud connections. Hangers and reinforcing bars near stud bolts contributed to the reduction of brittle failure. From the evaluation on the tensile strength by previous design guidelines, it was shown that CCD (Concrete Capacity Design) method was more suitable for estimation of test strength.

Laminate Tensile Failure Strength Prediction using Stress Failure Criteria

  • Lee, Myoung Keon;Kim, Jae Hoon
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.6
    • /
    • pp.19-25
    • /
    • 2021
  • This paper presents a method that uses the stress failure criteria to predict the tensile failure strength of open-hole laminates with stress concentrations. The composite material used in this study corresponds to a 177 ℃ cured, carbon/epoxy unidirectional tape prepreg. The results obtained by testing ten different laminates were compared and analyzed to verify the tensile strength of the open-hole laminates predicted using the proposed stress failure criteria. The findings of this study confirm that the tensile strength predictions performed using the proposed method are generally accurate, except in cases involving highly soft laminates (10% of 0° ply).