• 제목/요약/키워드: Design formula

검색결과 1,321건 처리시간 0.03초

2관성 모터 시스템의 속도제어를 위한 I-PD제어기 설계 (I-PD Controller Design of Motor Speed Control in a Two-Mass Motor Drive system)

  • 심용훈;서병설
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.42-45
    • /
    • 2002
  • In the two-mass motor drive system driving a load through a flexible shaft or transmission system, a shaft torsional vibration is often generated. The overshoot of the motor drive system easily causes vibration. In this case I-PD controller has been generally used in speed control, because of the simplicity of structure. This paper using an analytical pole assignment design, proposes the overshoot formulas, and the settling time formula. The objective of this paper is to provide a design method of I-PD controller by using overshoot formulas, and settling time formula. The simulation results show that we can design the controller with desired overshoot and settling time.

  • PDF

소하천 설계홍수량 추정모형의 적용성 검토 (Study on Applicability of Design Flood Estimation Methods in Creeks)

  • 김양수;이병주;이준호
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.163-167
    • /
    • 2004
  • Creeks, defined by creek's improvement law, have strong localities in the flow characteristics and environmental condition. During the recent ten-years, lots of flood damages have occurred rather in the creeks. However, quantity and stream design information are poor while the national-class and local-class streams have sufficient. This causes a problem on improving the safety from flood. This study focuses on assessment of practical applicability for design flood estimation models. For this, Rational formula, Clark's model and Nakayath synthetic unit hydrograph method are estimated by data of the creek comprehensive improvement plan report, etc.

  • PDF

6 MV X-선 빔을 사용하는 치료실에 설치되는 직접 차폐식 도어의 차폐 두께 계산식 (Calculation Formula for Shielding Thickness of Direct Shielded Door installed in Treatment Room using a 6 MV X-ray Beam)

  • 박철서;김종언;강은보
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.545-552
    • /
    • 2020
  • 이 연구의 목적은 NCRP 보고서 151과 IAEA 안전 보고서 시리즈 47 기반으로 직접차폐식 도어의 납 두께 계산식을 유도하는 데 있다. 직접차폐식 도어에서 선량률 계산식을 유도한 후, 이 식을 납 차폐 두께 계산식에 대입하여 도어에서 차폐 두께 계산식을 유도하였다. 유도된 직접차폐식 도어의 차폐 두께 계산식으로부터 계산된 납 차폐 두께는 NCRP 및 IAEA 2차 방벽 차폐 두께 계산 방법으로 산출된 두께보다 약 6% 낮았다. 이 결과는 NCRP 및 IAEA 2차 방벽 차폐 두께 계산 방법으로부터 두께 계산이 더 보수적이고 2차 빔 차폐에 잘 맞는다는 의미로 해석된다. 결론적으로, 이 연구에서 유도된 직접차폐식 도어의 납 차폐 두께 계산식은 도어의 차폐 설계에 유용하게 사용될 수 있을 것으로 사료된다.

국내 매입 말뚝 관리를 위한 항타공식 활용 가능성 평가 및 제안에 관한 연구 (Feasibility Appraisal and Proposal of a Pile Driving Formula for Domestic Pre-bored Pile Management)

  • 김건웅;서승환;김주형;정문경
    • 한국지반공학회논문집
    • /
    • 제39권11호
    • /
    • pp.71-84
    • /
    • 2023
  • 국내 구조물 기초설계기준은 전체 말뚝 수량의 1~3%에 대해 동재하시험 또는 정재하시험을 수행하도록 규정하였다. 나머지 약 97%에서 99% 말뚝의 시공 품질은 통상적으로 항타 관입량으로 관리한다. 대다수 말뚝에 적용되는 기존 관입량 관리방식에서 항타 에너지도 함께 고려하는 항타공식으로 말뚝의 시공 품질을 관리한다면 신뢰성이 향상될 것으로 판단된다. 본 연구에서는 기존 항타공식의 국내 말뚝 관리 활용 가능성을 검토하였다. 하지만, 해외에서 만들어진 기존 항타공식들은 상대적으로 얕은 깊이에 풍화암이나 연암이 있으며 매입 말뚝을 주로 활용하는 국내 실정에 맞게 개선할 필요가 있다. 그러므로, Modified Gates 공식을 국내 데이터를 활용하여 개선하였고, 이를 활용한 말뚝 관리 가능성을 확인하였다. 개선된 공식은 적은 변수를 활용함에도, 동재하시험과 유사한 수준의 정확도로 매입 말뚝 지지력을 예측하였다. 제안된 항타공식은 향후 말뚝의 시공 품질관리에 실무적으로 잘 활용할 수 있을 것으로 기대된다.

플랜지형 벽체 효과를 고려한 철근 콘크리트 전단벽 구조물의 고유주기식 (Natural Period Formula of a Reinforced Concrete Shear Wall Structure Considering Flange Wall Effect)

  • 노지은;김중호;허무원;박태원;이상현
    • 한국지진공학회논문집
    • /
    • 제22권2호
    • /
    • pp.55-62
    • /
    • 2018
  • In this study, natural period formular is presented for a RC shear wall structure with H-, T-, and L-shaped wall sections. The natural period formular proposed by Goel and Chopra and adopted in ASCE 7-10 was modified by using the ratio of the flange and web wall area. The natural periods of structures with H-shaped wall were numerically obtained, the results indicated that the ASCE 7-10 could not consider the natural period variation according to the length of the flange wall, but the proposed formula could do. Especially, ASCE 7-10 estimated much longer periods than eigenvalue analysis, and this implies that conservative seismic design is difficult. The periods by eigenvalue analysis exist between the upper and lower bounds given by the proposed formula, and conservative design is possible by using the proposed lower bound value. In order to verity the effectiveness of the proposed method, actual residential buildings with various types of flange walls are considered. Ambient vibration tests, eigenvalue analyses, and nonlinear dynamic analyses were conducted and the periods were compared with the values by ASCE 7-10 and the proposed formula. The results showed that the proposed formula could estimate more accurately the periods than ASCE 7-10.

파임을 가진 국산 침엽수재의 휨성능 및 구조설계기준에 관한 연구 (Bending Properties and Recommened Design Criteria for Domestic Softwood with Notch)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권4호
    • /
    • pp.6-12
    • /
    • 1998
  • Test results of domestic softwood lumber were presented to examine the notch effect of beams and compare to present AIJ(Architecture Institute of Japan) formula in notched wood member especially positioned in bottom side (tension side) of a beam. Notched lumber was tested under following condition : each specimen supported simply, and subjected to third-point loading at points of 1/3 of the span length. Notch was located opposite side to loading direction and notch depth were 1/6, 1/4, 1/3 of beam depth. Deflection and load were measured by digital dial guage each in 25kgf increment. Bending test results were as follows; Mpro/Mmax range (proportional and maxium bending moment ratio in notched beam) was 0.5 - 0.65. It was considered that maxium bending moment was about 1.5 times to proportional bending moment in notched beam and showed same tendency in the test result of ordinary wood specimens. AU standard formula for the tension side notch, Mmat = 0.6 ${\times}$ (Zo $\sigma$), the constant 0.6 was suitble for notch ratio(notch depth to beam depth) 1/6, but this ratio for 1/4, and 1/3 was not. So it is preferable to accept smaller value than 0.6 for notch ratio more than 1/3. These experiment results showed critical effect in tension side notched wood beam especially in greater than notch ratio 1.3 of wood beam. From the above results, it is recommened to revise design formula adoptable to domestic wood constructon member with tension side notched member.

  • PDF

선박 선저외판의 좌굴특성에 관한 연구 - 보강재의 구속영향 검토 - (Buckling Characteristics of Ship Bottom Plate - On the Stiffener Restraint Effects -)

  • 함주혁;김을년
    • 대한조선학회논문집
    • /
    • 제31권4호
    • /
    • pp.130-138
    • /
    • 1994
  • 선저외판은 수압과 동시에 면내 압축력을 받는다. 특히 살물선이 Alternate은 하중상태에서 흘수가 큰 경우, 외판구조는 배길이 및 폭방향의 극심한 압축력과 횡수압을 받기 때문에 설계자가 기존의 선급규정 및 설계기준을 이용하여 선저외판의 치수를 결정하고자 할 때 상당한 어려움을 겪는다. 본 연구에서는 선저 부위의 격자(Grillage)구조물에서 판주의를 둘러싼 보강재의 비틀림 강성을 추가로 고려하여 선저외판의 경계부가 탄성구속이며 면내 및 면외의 복합하중이 작용하는 선저외판의 좌굴강도 평가를 통해 보다 실제적인 선저외판의 치수 결정에 대한 선박 구조설계 측면에서의 타당성을 실적선 자료를 근거로 하여 검토해 보고자 한다. 따라서 경계조건에 따른 판의 탄성좌굴강도의 영향을 특성치 문제로 취급하여 유도된 판의 탄성구속 좌굴계수를 기존의 평가식에 추가로 고려하는 좌굴평가 방법에 근거하여 실적선의 선저외판 치수를 계산하였다. 또한 극심한 면내 및 면외하중과 주변 보강재 효과를 고려하여 상기 계산에 따라 산출된 외판치수에 대한 평가와 다양한 선급 규정에 따른 결과 그리고 1차연구의 방법에 따른 결과를 서로 비교 분석하여 보았으며 이들 각종 평가 결과들을 토대로 실적선 선저외판의 좌굴평가에 대한 실용성을 타진해 보았다.

  • PDF

L-모멘트 및 LH-모멘트 기법에 의한 적정 설계홍수량의 유도(II)-LH-모멘트법을 중심으로 (Derivatio of Optimal Design Flood by L-Moments and LH-Moments(II) - On the method of LH-Moments -)

  • 이순혁
    • 한국농공학회지
    • /
    • 제41권3호
    • /
    • pp.41-50
    • /
    • 1999
  • Derivatio of reasonable design floods was attempted by comparative analysis of design floods derived by Generalized Extreme Value(GEV) distribution using methods of L-moments and LH-moments for the annual maximum series at ten watersheds along Han, Nagdong. Geum, Yeongsan and Seomjin river systems, LH-coefficient of variation, LH-skewness and Lh-kurtosis were calcualted by KH-moment ration respectively. Paramenters were estimated by the Method of LH-Moments, Design floods obtained by Method of LH-Moments using different methods for plotting positionsi n GEV distribution and design floods were compared with those obtained using the Method of L-Moments by the Relative Mean Errors(RME) and Relative Absolute Errors(RAE). The results was found that design floods derived by the method of L-Moments and LH-Moments using Cunnane plotting position formula in the GEV distribution are much closer to those of the observed data in comparison with those obtained by methods of L-moments and LH-moments using the other formula for plotting positions from the viewpoint of Relative Mean Errors and Relative Absolute Errors. In viewpoint of the fact that hydrqulic structures including dams and levees are genrally using design floods with the return period of two hundred years or so, design floods derived by LH-Moments are seemed to be more reasonable than those of L-Moments in the GEV distribution.

  • PDF

도시철도 및 광역철도 승강장 면적산정식의 개선방안 연구 (The Improvement of the Area Estimation of the Metropolitan Railway Station Platforms)

  • 김진호;신민정;유소영;김태완
    • 대한토목학회논문집
    • /
    • 제38권6호
    • /
    • pp.991-999
    • /
    • 2018
  • 광역 도시권의 대중교통 시스템에서 철도교통이 차지하는 비중이 증가함에 따라 정거장 및 환승시설에 철도 이용자가 집중되어 극심한 혼잡상황이 반복되고 있다. 이로 인해 안전성, 편의성 측면에서 이용객의 불편이 가중되고, 정거장의 적정면적 산정에 대한 중요성이 요구되고 있다. 현재, 광역 도시철도 정거장에서 사용하고 있는 면적산정식은 1970년대 일본의 면적산정식을 일부 변형한 것으로 우리나라의 사회 문화 환경과 시대 흐름에 따른 이용객의 패턴 변화 등을 반영하고 있지 못하며, 주요 결정변수에 대한 기술적 근거도 미흡한 상황이다. 따라서, 본 연구에서는 승강장 면적산정식 개선(안)을 제시하고자 광역 도시철도 정거장 설계지침의 면적산정식과 보행 환경의 만족도에 대한 이론적 근거를 분석하고, 광역철도 5개 정거장 및 도시철도 15개 정거장에 대한 현장조사를 통해 개선된 면적산정식을 검증하였다. 면적산정식 개선(안) 적용한 결과에 따르면, 기존 면적산정식은 주요 공간에 대하여 LOS E 등급으로 나타났으나 개선된 면적산정식을 적용시 D등급의 보행환경이 구현되는 것으로 나타났다. 도출된 결과로부터 설계지침의 승강장 면적 산정시 사용되는 설계요소에 대한 개선(안)을 제시하였다.

Sample size calculation for comparing time-averaged responses in K-group repeated binary outcomes

  • Wang, Jijia;Zhang, Song;Ahn, Chul
    • Communications for Statistical Applications and Methods
    • /
    • 제25권3호
    • /
    • pp.321-328
    • /
    • 2018
  • In clinical trials with repeated measurements, the time-averaged difference (TAD) may provide a more powerful evaluation of treatment efficacy than the rate of changes over time when the treatment effect has rapid onset and repeated measurements continue across an extended period after a maximum effect is achieved (Overall and Doyle, Controlled Clinical Trials, 15, 100-123, 1994). The sample size formula has been investigated by many researchers for the evaluation of TAD in two treatment groups. For the evaluation of TAD in multi-arm trials, Zhang and Ahn (Computational Statistics & Data Analysis, 58, 283-291, 2013) and Lou et al. (Communications in Statistics-Theory and Methods, 46, 11204-11213, 2017b) developed the sample size formulas for continuous outcomes and count outcomes, respectively. In this paper, we derive a sample size formula to evaluate the TAD of the repeated binary outcomes in multi-arm trials using the generalized estimating equation approach. This proposed sample size formula accounts for various correlation structures and missing patterns (including a mixture of independent missing and monotone missing patterns) that are frequently encountered by practitioners in clinical trials. We conduct simulation studies to assess the performance of the proposed sample size formula under a wide range of design parameters. The results show that the empirical powers and the empirical Type I errors are close to nominal levels. We illustrate our proposed method using a clinical trial example.