• Title/Summary/Keyword: Design for test

Search Result 17,974, Processing Time 0.045 seconds

Manufacture of High-temperature High-pressure Vessel for Mixed Gas Performance Test via Optimized Design (최적화 설계를 통한 혼합가스 성능시험용 고온 고압 용기의 제작)

  • Ku, Hyoun-Kon;Ryu, Hyung-Min;Ahn, Jae-Woong;Bae, Young-Gwan;Kim, Jin-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.11
    • /
    • pp.83-88
    • /
    • 2019
  • In this study, the high-temperature high-pressure vessel was successfully manufactured, which can be used to store pressurized air and to increase the temperature for the mix performance test of high-temperature high-pressure air with coolant (e.g., water). In this research, static structure analysis and transient thermal analysis were performed using the commercial software Midas NFX 2015 R1. Based on the results, the optimized pressure vessel design was carried out. As a result of the optimized design, the minimum stress and minimum weight were found at 120 mm of the vessel thickness, and the optimized pressure vessel was verified. Finally, through manufacture and performance test (e.g., the non-destructive inspection and hydraulic pressure test), the reliability and safety were validated for the designed pressure vessel.

Structural Safety of Universal Joint using FEM Simulation (FEM 시뮬레이션을 이용한 유니버설 조인트의 구조안전성)

  • Jung, Jong Yun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.213-219
    • /
    • 2018
  • Mechanical components are to be produced with accurate dimensions in order to function properly in assemblies of a machine. Once designs of mechanical components are created, designers examine the designs by adopting many known experimental methods. A primary test method includes stress and strain evaluation of structural parts. In addition, fatigue test and vibration analysis are an important test method for mechanical components. Real experiments at a laboratory are established when products are manufactured. Since design changes should be done before producing the designs in factories, rapid modifications for new designs are required in production industries. FEM simulation is a proper choice for a design evaluation with speed at a detail stage in design process. This research focuses modeling and mechanical simulation of a mechanical component in order to ensure structural safety. In this paper, a universal joint, being used in driving axels of vehicles, is studied as a target component. A design model is created and tested in some ways by using commercial software of FEM. The designed component is being twisted to transmit heavy power and thus, torsional stress should be under strengths of the component's material. The next is fatigue analysis to convince fatigue cycles to be within the endurance limit of the material. Another test is a vibration analysis for rotational components. This research draws final conclusions from these test analyses and recommends whether the designed model is under safety condition in terms of mechanical structure.

An Efficient Design Strategy of Core Test Wrapper For SOC Testing (SOC 테스트를 위한 효율적인 코어 테스트 Wrapper 설계 기법)

  • Kim, Moon-Joon;Chang, Hoon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.3_4
    • /
    • pp.160-169
    • /
    • 2004
  • With an emergence of SOC from developed IC technology, the VLSI design has required the core re-use technique and modular test development. To minimize the cost of testing SOC, an efficient method is required to optimize the test time and area overhead in conjunction for the core test wrapper, which is one of the important elements for SOC test architecture. In this paper, we propose an efficient design strategy of core test wrapper to achieve the minimum cost for SOC testing. The proposed strategy adopted advantages of traditional methods and more developed to be successfully used in practice.

Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT) (대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전)

  • Ahn, Jong-Woo;Kim, Gun-Do;Kim, Ki-Sup;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.6
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.

A Study on the Development of Doorstep Equipment for Both the Low and the High Level Platforms - Focus on Conceptual Design & Prototype's Vibration Test Result - (저상 고상 승강장 겸용 승강시스템 기술개발에 관한 연구 - 개념설계 및 시작품의 진동시험 결과를 중심으로 -)

  • Park, Min-Heung;Lee, Jeong-Hun;Choi, Deuck-Ho;Kim, Chul-Su
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2979-2986
    • /
    • 2011
  • In this study, we review all matters for system application based on the international and the domestic standards. Considering the minimization of bottom frame damage, ease of maintenance, withstanding-environmental performance (condensation or rain), maintenance of airtightness, customer convenience and safety issues in railway vehicle, the conceptual design for doorstep equipment for both the low and the high level platforms is carried out. On the basis of conceptual design, the prototype is manufactured. We perform the vibration test based on the international standard IEC-61373 for securement of the reliability and enhancement of design & production. Finally we would like to describe the test results.

  • PDF

Noise Prediction and Design of Soundproof Facilities for the High Speed Train (고속열차(TGV) 주행시 연변에서의 소음예측 및 방음시설설계)

  • ;J. P. Clairbois
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1106-1115
    • /
    • 1999
  • This paper sums up the study of the soundproof facilities (noise barriers) to be placed on the test track section within the Seoul-Pusan H.S.T. project. The objective of this study is to determine optimum design of soundproof including height, length, location, sound absorbing materials for test track(chonan-taejon). This paper shows the model to design the shape and materials of noise barrier for high speed trains(TGV, ICE, ect). The design of soundproof facilities is to be conducted by MITHRA for the prediction of noise impact of the TGV and for optimising noise barriers in order to reduce the noise generated by high speed trains. A number of computer simulations are carried out in order to determine the specification of noise barrier on test track.

  • PDF

Limited Ductile Capacity of Reinforced Concrete Bridge Pier with Longitudinal Steel Lap-splicing by Pseudo Dynamic Test (유사동적 실험에 의한 철근콘크리트 교각의 주철근 겹이음에 따른 한정연성능력)

  • 박창규;박진영;조대연;이대형;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.885-890
    • /
    • 2002
  • Pseudo dynamic test is an on-line computer control method to achieve the realism of shaking table test with the economy and versatility of the conventional quasi-static approach. Pseudo dynamic tests of four full-size RC bridge piers have been carried out to investigate their seismic performance. For the purpose of precise evaluation, the experimental investigation was conducted to study the seismic performance of the real size specimen, which is constructed for highway bridge piers in Korean peninsula. Since it is believed that Korea belongs to the moderate seismicity region, three test specimens were designed in accordance with limited ductility design concept. Another one test specimen was nonseismically designed according to a conventional code. Important test parameters were transverse reinforcement and lap splicing. Lap splicing was frequently used in the plastic hinge region of many bridge columns. Furthermore, the seismic design code is not present about lap splice in Korean Roadway Bridge Design Code. The results show that specimens designed according to the limited ductility design concept exhibit higher seismic resistance. Specimens with longitudinal steel lap splice in the plastic hinge region appeared to significantly fail at low ductility level.

  • PDF

The Estimation of Bearing Capacity of Auger-drilled Pile in Sand-Gravel by Dynamic Load Test (동재하시험에 의한 모래자갈층에 근입된 매입말뚝의 지지력 산정)

  • Choi, Ki-Chul;Moon, Yu-Ho;Oh, Won-Keun;Chun, Byung-Sik
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1819-1826
    • /
    • 2007
  • This study results of performed field load test in order to estimate the best pile length assessment and allowable bearing capacity of the pile foundation. End of initial driving(EOID) and restrike of pile dynamic loading tests were performed to calculate allowable bearing capacity of the experimental pile side and results were compared with the allowable bearing capacity estimated by theory. The results of allowable bearing capacity by EOID test is $1.08{\sim}1.21$ in the range of compared to the capacity calculated by the Structure Foundation Design Criterion. Allowable bearing Capacity by restrike of pile dynamic loading test is $1.32{\sim}1.48$ in the range of compared to the Structure Foundation Design Criterion. The Foundation Design Criterion underestimated the pile capacity. If the bearing capacity calculated by Structure Foundation Design Criterion is 100, EOID of pile dynamic loading test is 116, restrike of pile dynamic loading test is 138 for 20m pile used in this experimental.

  • PDF

A Study on Design of Dry Floor Tile Unit Method System (바닥타일 건식공법용 수지매트 개발에 관한 연구)

  • 김상미;조상영;김성식;임남기;정병훈;김무성
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.22-27
    • /
    • 2001
  • The purpose of this study is development of dry floor tile method that practically used for improving wet method's defect, with resin mat design. PE resin used mat which satisfied with bonding test, waterproof test, resistance to chemical attack test, resistance to impact test and freezing and thawing test is confirmed the basic property.

  • PDF