• Title/Summary/Keyword: Design flowrate

Search Result 159, Processing Time 0.028 seconds

Derivation of the Risk-Safety Factor Relation for Optimal Storm Sewer Design in Urban Area (도시지역의 최적 배수관망 설계를 위한 Risk Safety Factor 관계의 설정)

  • Kim, Mun Mo;Lee, Won Hwan;Cho, Won Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.129-134
    • /
    • 1992
  • This paper presents the relation between risk and safety factor for optimal storm sewer design in urban area. For reliability analysis of the storm sewer, uncertainty of the various parameters of constituting equation determining the capacity and load of storm" sewer is considered and risk is determined. In this study, reliability analysis method is applied to Seongsan detention reservoir basin which area is $381,000m^2$ Darcy-Weisbach equation is used for determining capacity of the storm sewer and rational formula is used for determining load. Safety factor representing ratio of the sewer capacity and design flowrate is calculated, and relating with risk. Then risk and safety factor with return period is obtained and it is used for optimal design of storm sewer.

  • PDF

Optimal Design of Orifice typed Distribution Channel using Step Method Program (Step method 프로그램을 이용한 orifice 분배수로의 최적 설계에 관한 연구)

  • Park, No-Suk;Park, Sangcheol;Kim, Sung-soo;Lee, Seonjoo;Jeong, Nam-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.691-700
    • /
    • 2006
  • This study conducted to optimize the design and operation of orifice typed distribution channels which were generally constructed to link the rapid mixing process and flocculation/sedimentation basin. To accomplish the goal of this study, programming step method using FORTRAN 90, was applied it to simulate the performance of existing distribution channel in the selected S DWTP (Drinking Water Treatment Plant). The proposed step method program was validated in terms of the feasibility with comparison between the measurement and prediction value in each orifice. From the evaluation results of the current conditions with the design and operation, it was revealed that the existing gradient of the tapered channel is not appropriate. Also, we suggested that in the case of the inlet width being 3.5m, reducing the downstream width by about 0.5m would make more equitable distribution flow in the channel. Consequently, dealing with various conditions of the design and operation with distribution channel, we could conclude that for the parallel typed channel, as the width is wider and the diameter of orifice is smaller, the more equitable distribution occur. In addition, the inlet flowrate and the number of orifice can affect the flow velocity in the channel.

Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Curvature Radius of a Rear-Guider for a Room Air-Conditioner (리어가이더 곡률반경에 따른 룸에어콘용 관류홴의 공력성능에 대한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.36-44
    • /
    • 2013
  • The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. Also, these factors are given to the various diameter ratio between a basic circle and a impeller. The static pressure and the flowrate of a cross-flow fan were measured with a fan-tester. It could be found that the useful design factors with a good aerodynamic performance exist in the certain assembly conditions of an indoor RAC. Therefore, it could be known that a new published patent determining the easy design of an indoor RAC can be applied in a variety of goods.

Conceptual Design and Manufacturing Scheme of a Gas Generator for 7 tonf Class Rocket Engine (7톤급 로켓엔진 가스발생기 개념설계 및 제작계획)

  • Lim, Byoung-Jik;Kim, Moon-Ki;Kang, Dong-Hyuk;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.451-453
    • /
    • 2012
  • Conceptual design and manufacturing scheme of a gas generator for 7 tonf class rocket engine were described. The combustion chamber pressure, O/F ratio, and total flow rate were decided to be 6 MPa, 0.321, and 1 kg/s respectively in consequence of the engine system design. Based on the parameters conceptual design of the gas generator was carried out and its outer dimension was about ${\Phi}100{\times}250mm$. Most parts of the gas generator to be jointed together by brazing or TIG welding and, if possible, the strength and leakproof tests are to be conducted in every step for checking the welding section.

  • PDF

Prediction of Adiabatic Capillary Tube Length of Heat Pump Using Carbon Dioxide (CO2 히트펌프용 단열 모세관 길이 예측에 관한 연구)

  • Oh, Hoo-Kyu;Choi, Kwang-Hwan;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.576-581
    • /
    • 2011
  • In this paper, the prediction of adiabatic capillary tube of heat pump using carbon dioxide is investigated theoretically and experimentally to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include evaporation temperature, cooling pressure of gas cooler, mass flowrate, and the length and diameter of capillary tube. Based on study results of several researchers, the correlation predicting the length of capillary tube of $CO_2$ heat pump was proposed. And the experimental results of evaporation temperature, mass flowrate and cooling pressure in adiabatic capillary tube have an good agreement to those calculated from Eq. (3) within 0.63~10.9%. Therefore, the prediction calculating the length of adiabatic capillary tube of $CO_2$ heat pump was proposed at the given conditions such as cooling pressure, evaporation temperature and capillary tube diameter.

A Study on Prediction of Sedimentation Efficiency for Sedimentation Basin using Lagrangian Method (침전지의 유동 특성과 Lagrangian Method를 이용한 침전효율 예측에 관한 연구)

  • Choi, Jong-Woong;Hong, Sung-Taek;Kim, Seong-Su;Kim, Youn-Kwon;Park, No-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.229-236
    • /
    • 2017
  • Flow characteristics analysis and tracer test simulations for the rectangular typed sedimentation basins, which have been operated at D_water treatment plant in Korea, were carried out using CFD (Computational Fluid Dynamics) techniques for design ($15,864m^3/day$) and operation flowrate ($33,333m^3/day$). Also, each efficiency of the sedimentation basin was evaluated by application of the Lagrangin technique on the assumption of the particles flowing into the inlet of the sedimentation basin. From the results of simulation, the mean velocity values for making the flow in the settling basin as a plug flow region were derived as 0.00193 m/s and 0.00417 m/s, respectively. In addition, ${\beta}$ (effective contact factor) values were calculated to be 0.51 and 0.46, and the Morrill Index values were 6.05 and 3.21, respectively for both flowrate conditions.

Application of in-situ Flushing to the Soil Contaminated by Organic Compounds (유기물질에 의해 오염된 토양에 대한 in-situ세척기법의 적용성 연구)

  • 최상일;류두현;김형수
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.2
    • /
    • pp.61-72
    • /
    • 1996
  • A series of batch and lab-scale continuous tests were conducted to optimize the design parameters for the full-scale in-situ soil flushing experiments. The cleaning abilities of the surfactant solutions of Tween 80, Triton X-100 and SDS were compared for the soil artificially contaminated by hydrophobic organic contaminants: n-dodecane, naphthalene and anthracene. Tween 80 and Triton X-100 were shown to be efficient for n-dodecane. SDS and Tween 80 were shown to be efficient for naphthalene and anthracene. At the end of each column test, the sorbed amount of surfactant to soil was also measured. Tween 80 was found to be the least adsorbed surfactant to soil. The flushing ability at flowrate of 7 ml/min, was hampered comparing to flowrate of 3 and 5 ml/min. Initial pH of the soil did not significantly affect the flushing efficiencies. Tween 80 was determined as the most harmless surfactant for the Gram(+) and Gram(-) bacteria.

  • PDF

Numerical study of fluid behavior on protruding shapes within the inlet part of pressurized membrane module using computational fluid dynamics

  • Choi, Changkyoo;Lee, Chulmin;Park, No-Suk;Kim, In S.
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.498-505
    • /
    • 2020
  • This study analyzes the velocity and pressure incurred by protruding shapes installed within the inlet part of a pressurized membrane module during operation to determine the fluid flow distribution. In this paper, to find the flow distribution within a module, it investigates the velocity and pressure values at cross-sectional and outlet planes, and 9 sections classified on outlet plane using computational fluid dynamics. From the Reynolds number (Re), the fluid flow was estimated to be turbulent when the Re exceeded 4,000. In the vertical cross-sectional plane, shape 4 and 6 (round-type protrusion) showed the relatively high velocity of 0.535 m/s and 0.558 m/s, respectively, indicating a uniform flow distribution. From the velocity and pressure at the outlet, shape 4 also displayed a relatively uniform fluid velocity and pressure, indicating that fluid from the inlet rapidly and uniformly reached the outlet, however, from detailed data of velocity, pressure and flowrate obtained from 9 sections at the outlet, shape 6 revealed the low standard deviations for each section. Therefore, shape 6 was deemed to induce the ideal flow, since it maintained a uniform pressure, velocity and flowrate distribution.

Performance Analysis of Refrigeration Cycle of Hydrocarbon Refrigerant using Suction-Line Heat Exchanger (흡입관 열교환기를 이용한 탄화수소계 냉매용 냉동사이클의 성능 분석)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2195-2201
    • /
    • 2009
  • This paper considers the influence of suction-line heat exchangers on the efficiency of a refrigeration cycle using hydrocarbon refrigerants such as R290, R600a and R1270. These suction-line heat exchangers can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analyze the performance characteristics of refrigeration cycle with suction-line heat exchanger. The influence of operating conditions, such as the mass flowrate of hydrocarbon refrigerants, inner diameter tube and length of suction-line heat exchanger, to the performance of the cycle is also analyzed in the paper. Results showed that the mass flowrate of hydrocarbon refrigerants, inner diameter tube and length of suction-line heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle of hydrocarbon refrigerants using suction-line heat exchanger.

Characteristic Analysis of a Small ALIP for the Developing of the Liquid Sodium (액체 소듐 순환 구동용 소형 환단면 선형유도전자펌프의 특성 분석)

  • Kim, Hee-Reyoung;Kim, Jong-Man;Nam, Ho-Yun;Hwang, Jong-Sun;Seo, Jang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.1-3
    • /
    • 1999
  • EM (ElectroMagnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). (In the present study, pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.

  • PDF