• 제목/요약/키워드: Design flowrate

검색결과 159건 처리시간 0.026초

퍼지제어기를 이용한 하폐수처리공정의 최적화 (Fuzzy Control and Optimization for the Wastewater Treatment Process)

  • 천성표;김봉철;김성신
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2000년도 추계학술대회 학술발표 논문집
    • /
    • pp.452-455
    • /
    • 2000
  • There are increasingly important financial incentives and environmental consideration to improve the effluent quality of wastewater from domestic and industrial users. The activated sludge process is a widely used biological wastewater treatment process. The activated sludge process is complicated due to the many factors such as the variation of influent flowrate and concentration, the complexity of biological reactions and the various operation conditions. Nowadays, not only suspended solids and residual carbon, but also nitrogen and phosphorous concentration of the effluent water must be taken into account for the design and operation of wastewater treatment plants. Also, the effluent quality to be met are more stringent. Therefore, an intelligent control approach is required in order to successful biological nitrogen removal. In this paper, the strategies for dosage of extra carbon in the anoxic zone and DO concentration in the aerobic zone are presented and evaluated through the simulation using the denitrification layout of the IWA simulation benchmark implemented by Matlab$\^$/5.3/Simulink$\^$/3.0. The control strategy to achieve sufficient denitrification rates in an anoxic zone. Methanol is used as an external extra carbon source. The external extra carbon source is required for the nitrogen removal process because nitrogen and organic concentration are fluctuated in the influent flowrate. The dissolved oxygen is calculated by So concentration in the activated sludge model NO.1. The air flowrate of each aerobic reactor is intelligently controlled to achieve the predefined setpoints. Air flowrate is adjusted by the fuzzy logic controller that includes two inputs and one output. The objective function for the optimization procedure is designed to improve effluent quality and reduce the operating cost.

  • PDF

과산화수소/케로신 소형 이원추진제 추력기의 설계 및 성능특성에 관한 연구 (Study for Design and Performance Characteristics of Small Bipropellant Thruster using $H_2O_2$/Kerosene)

  • 김정훈;이재원;전영진;채병찬;전준수;김유;김선진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2009
  • 본 연구에서는 고농도 과산화수소와 케로신을 각각 산화제와 연료로 사용하는 소형 이원추진제 추력기의 설계/제작 및 인젝터 성능특성 파악을 위한 수류시험을 수행하였다. 본 개발모델에서는 점화기, 인젝터, 막냉각 시스템을 통합하여 운용이 가능한 구조의 믹싱헤드를 적용하였으며, 각 부분으로의 공급유량 변경이 가능하도록 하여 최적 설계의 실험적 검증 및 효율성을 극대화하고자 하였다. 마지막으로 수류시험을 통해 인젝터 유량 및 추진제 분사패턴을 확인하였으며, 믹싱헤드의 설계 타당성을 검증하였다.

  • PDF

소수력발전소의 성능예측 기법 (A Study on the Performance Prediction Technique for Small Hydro Power Plants)

  • 박완순;이철형
    • 한국수소및신에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.61-68
    • /
    • 2003
  • This paper presents the methodology to analyze flow duration characteristics and performance prediction technique for small hydro power(SHP) Plants and its application. The flow duration curve can be decided by using monthly rainfall data at the most of the SHP sites with no useful hydrological data. It was proved that the monthly rainfall data can be characterized by using the cumulative density function of Weibull distribution and Thiessen method were adopted to decide flow duration curve at SHP plants. And, the performance prediction technique has been studied and development. One SHP plant was selected and performance characteristics was analyzed by using the developed technique, Primary design specfications such as design flowrate, plant capacity, operational rate and annual electricity production for the SHP plant were estimated, It was found that the methodology developed in this study can be a useful tool to predict the performance of SHP plants and candidate sites in Korea.

PCV 밸브의 설계 프로그램 개발에 관한 연구 (A Study on Development of Design Program for PCV Valve)

  • 이종훈;;이연원;김영덕
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.228-232
    • /
    • 2005
  • Automobiles are very important as modern society is developed. Increase of the number of the automobiles cause environmental problem, that is, air pollution. So, many countries are adopting a environmental law. Automobile manufacturing companies have developing methods to prevent air pollution with increase of the efficiency of automotive engines. PCV(Positive Crankcase Ventilation) system which is one of them is made by the closed loop that consists of combustion chamber, crankcase, manifold suction tube and manifold. PCV valve is attached on manifold tube to control the flowrate of blowby gas. PCV valve is an important part in this system but it is difficult to design PCV valve which satisfies the required flowrate of blowby gas. In this study, our purpose is to help a PCV valve designer with the development of a design program. We used 4th order Runge-Kutta method and Bernoulli's equation to analyze the spool dynamic motion. By the comparison between our program and experiment, we think that a PCV designer can use our program in their work place.

  • PDF

친수지역 강변여과수 열원을 활용한 냉난방시스템 개발 (Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront)

  • 조용;김대근;문종필
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF

Development of the Pneumatic Servo Valve

  • Kim, Dong-Soo;Choi, Byung-Oh;Kim, Kwang-Young;Lee, Won-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1146-1151
    • /
    • 2003
  • Pneumatic servo valve is an electro-mechanical device which change electric signals to a proper pneumatic signals, that is, flowrate and pressure. In this study, a pneumatic servo valve was designed and each simulation was conducted on any variation in the flowrate depending upon the magnetic force of the linear force motor and the displacement of the spool. And permanent magnet was used as a material for the plunger of the servo valve. Thereby, a low electrical power consumption type coil was desinged. And a modeling for the coil design was conducted by using the magnetic circuit. also, the feasibility of the modeling was verified by using a commercial magnetic field analysis program. The designed and fabrication of the spool and sleeve, position sensor, servo controller and the dynamic characteristic verified by the experiment.

  • PDF

냉매분사식 팽창장치를 적용한 냉동기의 특성에 관한 연구 (A Study on the Characteristics of the Refrigerator Using a Refrigerant Injection Type Expansion Device)

  • 조병옥
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.925-931
    • /
    • 2000
  • Refrigerating ability of vapor compression refrigerator is decided by the harmonic work of it's components such as compressor, condenser, evaporator, expansion device, and so on. In this study, choosing refrigerant injectors as a new one of expansion device, temperature change of the cold room, ice freezing ability, and power consumption on flowrate of injector and refrigerant charging condition are evaluated experimentally. As the results of this study, it is verified that the spray injection type refrigeration system has some merits according to the flowrate and spray pattern of injector and charging quantum of refrigerant. And there are some design factors such as spray pattern and shape of spray chamber to utilize and fabricate this refrigerant injection type refrigerator.

  • PDF

내부 열교환기를 이용한 R-1270용 냉동시스템의 성능 분석 (Performance Analysis of R-1270(Propylene) Refrigeration System Using Internal Heat Exchanger)

  • 구학근
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.36-42
    • /
    • 2014
  • This paper considers the influence of internal heat exchangers on the efficiency of a refrigerating system using R-1270. These internal heat exchangers(liquid-gas or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed. The main results were summarized as follows : the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, and effectiveness have the influences on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. With a thorough grasp of it is possible to design the R-1270 compression refrigeration cycle using internal heat exchanger.

수계별 소수력자원의 특성 (Characteristics of Small Hydro Power Resources for River System)

  • 박완순;이철형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.193.1-193.1
    • /
    • 2010
  • Small hydropower resources for five major river systems have been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the variation of inflow caused from rainfall condition. And another model to predict hydrologic performance for small hydropower(SHP) plants is established. Monthly inflow data measured at Andong dam were analyzed. The predicted results from the developed models in this study showed that the data were in good agreement with measured results of long term inflow at Andong dam. It was found that the models developed in this study can be used to predict the available potential and technical potential of SHP sites effectively. Based on the models developed in this study, the hydrologic performance for small hydropower sites located in river systems have been analyzed. The results show that the hydrologic performance characteristics of SHP sites have some difference between the river systems. Especially, the specific design flowrate and specific output of SHP sites located on North Han river and Nakdong river systems have large difference compared with other river systems.

  • PDF

75톤급 로켓엔진용 연료펌프의 수력성능시험 (Hydraulic Tests of Fuel Pump for 75-ton class Liquid Rocket Engines)

  • 김대진;홍순삼;최창호;노준구;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.78-81
    • /
    • 2009
  • 연료펌프에 대한 수력성능시험을 상온의 물을 매질로 하여 실시하였다. 시험된 연료펌프는 개방형 가스발생기 방식의 75톤급 액체로켓엔진에 적용할 목적으로 개발 중에 있다. 시험 결과, 연료펌프는 설계요구조건을 만족하였으며, 설계 유량에서의 양정과 효율은 수치해석에서 추정된 값보다 높았다. 또한 후방 베어링의 출구 압력이 예상보다 높았는데 이는 바이패스 배관의 입구가 좁기 때문이었다. 그리고 바이패스 곡관부의 차압 측정으로 누설 유량을 유추할 수 있었다.