• 제목/요약/키워드: Design flowrate

검색결과 159건 처리시간 0.024초

가솔린 엔진에서의 냉각수로의 전열량에 대한 연구 (A Study on the Heat Rejection to Coolant in a Gasoline Engine)

  • 류택용;신승용;이은현;최재권
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.77-88
    • /
    • 1997
  • The heat rejection to coolant is a dominant factor for building vehicle cooling system such as radiator and cooling fan. Since the vehicle cooling system also has effects on fuel consumption and noise, the study of heat rejection to coolant has been emphasized. However, the study on heat rejection to coolant has been mainly focused on the field that related to the characteristics of combustion and localized heat loss. It is no much of use in design for the entire cooling system because it is focused on such a specific point. In this work, the heat rejection rate to coolant for four different engines are obtained to derive a simple heat transfer empirical formula that can be applied to the engine cooling system design, and it is compared with the other studies. Also, to observe effects of engine operation factors and heat transfer factors on coolant, we measured the metal temperature and the heat rejection rate. The heat rejection to coolant does not depend significantly upon the coolant flowrate, but mainly upon the amount of air fuel mixture and the air fuel ratio as long as the composition of coolant does not change. The reduction of heat rejection to coolant did not effectively improve the fuel consumption, but was mostly converted to raise the exhaust gas temperature and the oil temperature.

  • PDF

75톤급 로켓엔진용 산화제펌프의 수력성능시험 (Hydraulic Tests of Lox Pump for 75-ton class Liquid Rocket Engines)

  • 김대진;홍순삼;최창호;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.77-80
    • /
    • 2010
  • 산화제펌프에 대한 수력성능시험을 상온의 물을 매질로 하여 실시하였다. 시험 결과, 산화제펌프는 설계 조건을 만족하였으나, 양정과 효율 모두 상사 법칙을 완전히 만족하지는 않았다. 이 중 양정의 불일치는 고회전수 시험에서의 볼류트 손실 증가 때문으로 보인다. 또한 저유량 영역에서 펌프가 작동할 때에는 누설 유량이 증가하는 것으로 추정되었다.

  • PDF

다단계 반복기법을 이용한 관로시스템의 최적관경 결정 (determination of Optimum Pipe diameter Using Multi-Stage Iterative Method in Water Distribution system)

  • 한건연;박재홍
    • 한국수자원학회논문집
    • /
    • 제31권3호
    • /
    • pp.327-335
    • /
    • 1998
  • 상수관망은 상수공급시스템에서 핵심적인 부분이다. 주어진 상수공급시스템에서 배수관망에 대한 비용은 사업전체 비용에 대한 대부분을 차지하고 있다. 관망에 대한 설계과정 중에서 최적화기법을 사용하여 비용을 절감하기 위한 연구가 시도되었다. 주어진 상수관망 시스템의 설계시 고려되는 관경의 결정을 위해 유량해석과 최적화 기법이 연계되어 해석하는 반복기법이 적용되었다. 유량해석을 위해서 선형화기법이 되입되었고 관경의 최적화를 위해서 선형계획법에 기초한 개정 단체법을 이용하였다. 22개 관로와 35개 관로를 가진 실제관망에 본 모형을 적용한 결과 짧은 계산시간으로 최적화된 상용관을 결정할 수 있었다.

  • PDF

최적화기법을 이용한 축류형 송풍기개발에 관한 연구 (A Study of Development of an Axial-Type Fan with an Optimization Method)

  • 조봉수;조종현;정양범;조수용
    • 한국유체기계학회 논문집
    • /
    • 제10권6호
    • /
    • pp.7-16
    • /
    • 2007
  • An axial-type fan which operates at the relative total pressure of 671Pa and static pressure of 560Pa with the flow rate of $416.6m^3/min$ is developed with an optimization technique based on the gradient method. Prior to the optimization of fan blade, a three-dimensional axial-type fan blade is designed based on the free-vortex method along the radial direction. Twelve design variables are applied to the optimization of the rotor blade, and one design variable is selected for optimizing a stator which is located behind of the rotor and is used to support a fan driving motor. The total and static pressure are applied to the restriction condition with the operating flowrate on the design point, and the efficiency is chosen as the response variable to be maximized. Through these procedures, an initial axial-fan blade designed by the free vortex method is modified to increase the efficiency with the satisfaction of the operating condition. The optimized fan is tested to compare the aerodynamic performance with an imported same class fan. The test result shows that the optimized fan operates with the satisfaction of restriction conditions, but the imported fan cannot. From the experimental and numerical test, they show that this optimization method improves the fan efficiency and operating pressures of a fan designed by the classical fan design method.

液休용 이젝터 性能에 관한 CAD와 實驗結果와의 比較 (The Comparison of Experimental Results of Liquid Ejector Performance to Predictions by the Computer Aided Design Program)

  • 김경근;김명환;홍영표;고상철
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.520-527
    • /
    • 1988
  • 본 연구에서는 액체용 이젝터의 성능을 결정하는 여러가지 제약인자중 특히 레이놀즈수 변화에 따른 구동노즐의 면적비 및 목부길이가 액체용 이제터성능에 미치 는 영향을 체계적인 실험을 통하여 연구함으로써 기 개발된 CAD용 전산프로그램의 타 당성을 보다 세밀히 검토하고 이에 보완을 가하는데 연구의 목적이 있다.

도시유역의 저류지 설계를 위한 계획모형 비교분석 (A Comparison and Analysis of Planning Models for the Design of Detention Pond in Urban Area)

  • 이재준;곽창재;이상원
    • 한국방재학회 논문집
    • /
    • 제8권3호
    • /
    • pp.105-115
    • /
    • 2008
  • 도시화로 인한 유출량의 증가 및 도달시간의 단축은 도시재해의 한 원인이 되고 있다. 이를 막기 위하여 도시 배수유역내에 저류지를 설치하여 첨두도달시간을 지연시키고 방류량은 하수관거의 통수능 이하로 조절하는 방안을 활용하고 있다. 저류지를 설계 운영함에 있어서 사용되는 수문모형은 일반적으로 계획모형, 설계모형 및 운영모형으로 분류되고 있다. 본 연구에서는 재해영향평가서 22개소의 기 설계된 저류지를 분석대상으로 하여 여러 가지 저류지 계획모형의 적합성을 검토하였다. 저류지 계획모형으로는 삼각형, 사다리꼴 설계수문곡선과 경험적 공식을 이용한 11가지의 모형을 적용하였다. 저류지 계획모형의 분석에서 on-line 저류지의 경우는 사다리꼴 형태 설계수문곡선을 채택하고 있는 이종태 등 모형(1991)의 결과가 대상 저류지의 실저류량과 가장 유사함을 보였고, off-line 저류지의 경우는 삼각형 형태 설계수문곡선을 채택하고 있는 Abt and Grigg 모형(1978)의 결과가 비교적 양호한 결과를 보이는 것으로 나타났다.

하수처리수를 이용한 소수력발전소 설계 및 성능예측 (Design and Performance Prediction of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant)

  • 이철형;박완순;김원경;김정연;채규정
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.78-83
    • /
    • 2013
  • A methodology to predict the output performance of small hydro power plant using treated effluent in waste water treatment plant has been studied. Existing waste water treatment plant located in Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. .Based on the models developed in this study, the hydrologic performance characteristics for SHP sites have been analyzed. The results show that the flow duration characteristics of small hydropower plant for waste water treatment plant have quite differences compared with small hydropower plant for the river. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in waste water treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed. It was found that the models developed in this study can be used to decide the design performance of small hydropower plant for waste water treatment plant effectively.

수리실험을 이용한 지하유입시설 유입구 형상에 따른 수리학적 특성 분석 (Study of Hydraulic Characteristics with the Shape of the Intake of an Underground Inflow Facility using Hydraulic Experiments)

  • 성호제;박인환;이동섭
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.119-126
    • /
    • 2018
  • In recent years, as flood damage caused by heavy rains increased, the great-depth tunnel using urban underground space is emerging as a countermeasure of urban inundation. The great-depth tunnel is used to reduce urban inundation by using the underground space. The drainage efficiency of great-depth tunnel depends on the intake design, which leads to increase discharge into the underground space. The spiral intake and the tangential intake are commonly used for the inlet facility. The spiral intake creates a vortex flow along the drop shaft and reduces an energy of the flow by the wall friction. In the tangential intake, flow simply falls down into the drop shaft, and the design is simple to construct compared to the spiral intake. In the case of the spiral intake, the water level at the drop shaft entrance is risen due to the chocking induced by the flowrate increase. The drainage efficiency of the tangential intake decreases because the flow is not sufficiently accelerated under low flow conditions. Therefore, to compensate disadvantages of the previously suggested intake design, the multi-stage intake was developed which can stably withdraw water even under a low flow rate below the design flow rate. The hydraulic characteristics in the multi-stage intake were analyzed by changing the flow rate to compare the drainage performance according to the intake design. From the measurements, the drainage efficiency was improved in both the low and high flow rate conditions when the multi-stage inlet was employed.

해수냉난방용 판형 열교환기의 최적설계를 위한 수치적 연구 (Numerical Study for the Optimal Design of Plate Heat Exchanger Using at Seawater Air Conditioning)

  • 김현주;정영권;이호생;윤정인;손창효
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.29-35
    • /
    • 2014
  • Plate heat exchanger are being applied in the field of OTEC (ocean thermal energy conversion) and SWAC (seawater air conditioning) system. This study is to analyze numerically the heat transfer and pressure drop characteristics by using solid works flow simulation in order to offer optimum design data of plate heat exchanger. Plater heat exchanger proposed in this study is four types. The geometric design parameters of plate heat exchanger are a channel space, a flow orientation, a plate array, the flowrate of working fluid and so on. The main results for numerical analysis of plate heat exchangers are summarized as follows. Heat transfer performance for the channel space of 2.4 mm shows the highest value compared to other spaces. And, the Type 4 plate heat exchanger in Table 2 is the highest performance. From the pressure drop characteristics of plate heat exchanger, the channel space of 3.2 mm shows the lowest value. And Type 1 plate heat exchanger in Table 2 is the lowest pressure drop.

변압기 냉각 특성 해석 (Cooling Characteristic Analysis of Transformer's Radiator)

  • 김현재;양시원;김원석;권기영;이민제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1920-1925
    • /
    • 2007
  • A transformer is a device that changes the current and voltage by electricity induced between coil and core steel, and it is composed of metals and insulating materials. In the core of the transformer, the thermal load is generated by electric loss and the high temperature can make the break of insulating. So we must cool down the temperature of transformer by external radiators. According to cooling fan's usage, there are two cooling types, OA(Oil Natural Air Natural) and FA(Oil Natural Air Forced). For this study, we used Fluent 6.2 and analyzed the cooling characteristic of radiator. we calculated 1-fin of detail modeling that is similar to honeycomb structure and multi-fin(18-fin) calculation for OA and FA types. For the sensitivity study, we have different positions(side, under) of cooling fans for forced convection of FA type. The calculation results were compared with the measurement data which obtained from 135.45/69kV ultra transformer flowrate and temperature test. The aim of the study is to assess the Fluent code prediction on the radiator calculation and to use the data for optimizing transformer radiator design.

  • PDF