• Title/Summary/Keyword: Design and Operation Parameters

Search Result 805, Processing Time 0.025 seconds

A Study on the Biological Treatment of RO Concentrate Using Aerobic Granular Sludge (호기성 그래뉼 슬러지를 이용한 RO 농축수의 생물학적 처리에 관한 연구)

  • Kim, Hyun Gu;Ahn, Dae Hee;Cho, Eun Ha;Kim, Han Yong;Ye, Hyoung Young;Mun, Jung Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.2
    • /
    • pp.79-86
    • /
    • 2016
  • The purpose of this study is to efficiently improve biological sequencing batch reactor (SBR) system of high-concentrated nitrate nitrogen in reverse osmosis (RO) concentrates by total dissolved solids (TDS) regulation. Since a laboratory-scale SBR system had been operated, we had analyzed specific denitrification rate (SDNR) and specific oxygen uptake rate (SOUR) for microbial activity in according to various injection concentration of TDS. As a result, higher injection concentration of TDS decreased SDNR, and delayed denitrification within denitrification process. Moreover, the higher injection concentration of TDS was, the lower microbial activity was during operation of laboratory-scale SBR system. Therefore, the regulation of TDS injection concentration is necessary to improve efficiency of nitrate nitrogen in the biological SBR system, and treatment of calcium ion ($Ca^{2+}$) is also specifically focused to remove nitrate nitrogen. Moreover, analytical data of SDNR and SOUR can be the effective kinetic design parameters to application of biological treatment of RO concentrate by aerobic granular sludge (AGS).

Optimal Design of VCO Using Spiral Inductor (나선형 인덕터를 이용한 VCO 최적설계)

  • Kim, Yeong-Seok;Park, Jong-Uk;Kim, Chi-Won;Bae, Gi-Seong;Kim, Nam-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.8-15
    • /
    • 2002
  • We optimally designed the VCO(voltage-controlled oscillator) with spiral inductor using the MOSIS HP 0.5${\mu}{\textrm}{m}$ CMOS process. With the developed SPICE model of spiral inductor, the quality factor of spiral inductor was maximized at the operating frequency by varying the layout parameters, e.g., metal width, number of turns, radius, space of the metal lines. For the operation frequency of 2㎓, the inductance of about 3nH, and the MOSIS HP 0.5 CMOS process with the metal thickness of 0.8${\mu}{\textrm}{m}$, oxide thickness of 3${\mu}{\textrm}{m}$, the optimal width of metal lines is about 20${\mu}{\textrm}{m}$ for the maximum Quality factor. With the optimized spiral inductor, the VCO with LC tuning tank was designed, fabricated and measured. The measurements were peformed on-wafer using the HP8593E spectrum analyzer. The oscillation frequency was about 1.610Hz, the frequency variation of 250MHz(15%) with control voltage of 0V - 2V, and the phase noise of -108.4㏈c(@600KHz) from output spectrum.

A Numerical Study on Performance of a Heavy-Duty Diesel engine for Power Generation under Natural Gas-Diesel Dual Fuel Operation (발전용 대형 디젤 엔진의 천연가스-디젤혼소 운전 특성에 대한 수치해석 연구)

  • Cho, Jungkeun;Park, Sangjun;Song, Soonho;Hur, Kwang-Beom
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.2
    • /
    • pp.29-36
    • /
    • 2015
  • This study is an 1-D numerical study prior to modification of diesel engine for power plants to natural gas/diesel dual fuel engine using GT-Power with 1.5MW diesel engine for power generation. Natural gas injector was installed to intake manifold for dual fuel engine model. Effects on engine performance and characteristics were investigated when dual fuel is used in unmodified diesel engine. The analysis was done under 5 conditions from 0% to 40% of mixing rate on 720RPM engine speed. As a result of research, the engine performance was decreased as increasing ratio of natural gas. Engine brake power was decreased by 18.4% under 40% mixing rate condition. To clarify the reason, effects of injection timing and period were evaluated with DOE method. Considering this result, optimization was done for these parameters. Also, comparison between performances of dual fueled engine and diesel engine was made after optimizing the timing of injection by DOE method. As a result, engine brake power was decreased by 8.55% under mixing rate 40% condition showing 12.5% improvement.

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.

Effect of Sodium ion on the Anaerobic Degradation of Food Waste : Quantitative Evaluation, Inhibition Model (주방폐기물의 혐기성분해에 대한 나트륨이온의 영향: 저해 특성평가, 저해모델)

  • Shin, Hang-Sik;Song, Young-Chae;Paik, Byeong-Cheon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.2
    • /
    • pp.3-17
    • /
    • 1994
  • The inhibitory effect of sodium ion on the anaerobic degradation of food waste was studied by an anaerobic batch toxicity assay and inhibition model. The anaerobic degradation activity of food waste spiked with over $2g\;Na^+/L$ of sodium ion was severely inhibited at the initial stage of the exposure. The inhibition response of anaerobic microorganisms on the sodium ion estimated from the methane production was differed according to the concentration of sodium ion. The relative acclimation time(RAT) and methanation rate(RMR), defined as the ratios of initial lag time and maximum methane production rate of the sample spiked with sodium ion to the control. respectively, were used to evaluate the acclimation and inhibitory effects quantitatively on the anaerobic microorganisms. When sodium ion was increased from $2g\;Na^+/L$ to $20g\;Na^+/L$, the RAT was exponentially increased from 18.9 to 90. but the RMR was linearly decreased from 0.97 to 0.02. The effects of sodium ion for the maximum methanation rate, first order kinetic constant and ultimate methane production were well evaluated by a generalized nonlinear expression model. it could be described by the uncompetitive inhibition mode. The sodium ion concentration causing 50% inhibition of methanation activity was about $11g\;Na^+/L$, and the critical sodium ion beyond to compelete inhibition was 20 to $21g\;Na^+/L$. The presented results could be used to obtain the design or operation parameters of the anaerobic process treating food waste of high salt.

  • PDF